Вы находитесь на странице: 1из 6

Sl

Alarm Name Problem


No.

AntennaBranch_AntennaSystem VSWR Regarding Issue(Problem Between NODE-B To


1 ProblemInBranchA Anteena)

AntennaBranch_AntennaSystem VSWR Regarding Issue(Problem Between NODE-B To


2 ProblemInBranchB Anteena)
Power Related Issue( Power Is Not Reached At The RRU
3 AuxPlugInUnit_LossOfMains End.)
AuxPlugInUnit_PiuConnectionLo Plug In Unit RRU Is Physically Not Connected To The
4 st Node-B
5 AiDevice_GeneralHWError Alarm Indication devices are Faulty
6 DeviceGroup_GeneralSwError Configuration Issue (Software Version)

DeviceGroup_SfpModuleConfig
7 urationMismatch SFP module Relatd Issue(Physically & Configuration)
DeviceGroup_TemperatureExce
8 ptionallyHigh High Temperature Issue(Environmental)

9 DigitalCable_CableFailure Digital Cable Issue (Connected Between RRU & Node-B)


10 Disconnected External ALM Device is not connected (Alarms)
DownLinkBaseBandPool_DLHW LKF defined capacity is greater than the available
11 LessThanDLCapacity capacity for DCH.
Emergency Unlock of Software Software Licensing In Emergency State (HSDPA Services
12 Licensing Not Working )
13 EnclosureDoorOpen NODE-B Enclosure Issue.
NODE-B Enclosure Product Data Mismatch To Actual
14 EnclosureProductDataMismatch Configuration
May be HW Faulty Performance Degraded.(Shows The
15 GeneralHwError HW Details.)

Ethernet Link Connectivity Down Between RNC & NODE-


16 Heartbeat Failure B

17 License Key File Fault Licensing Issue


Loss of Synch Reference
18 Redundancy Synch Redundancy not available on NODE-B
NODE-B System Clock is not able to track any
19 Loss of Tracking Synchronization Reference
NbapCommon_LayerSetupFailu NBAP Common Signalling down between NODE-B &
20 re RNC
NodeBFunction_DlHwUsageExc
21 eedsDlLicenseLevel No. Of Users Exceeds For Downlink(LICENSE LIMIT)
NodeBFunction_UlHwUsageExc
22 eedsUlLicenseLevel No. Of Users Exceeds For Uplink(LICENSE LIMIT)
NTP Server (Synch Failure of NODE-B) Synch Fail
23 NTP Server Reachability Fault (Primary & Secondary)
Configuration Issue, HW Unit is not configured but
24 NumberOfHwEntitiesMismatch detected in the SYSTEM
OpticalInterfaceLink_OpticalInter
25 faceLinkFailure Optical Interface Link down between NODE-B & RRU
26 Password File Fault Password is not set at the NodeB end
In ATM Sites For TWO E1-Frame(IMA-LINK), Single E1-
27 PDH Loss of Frame PDH Signal goes down
28 PDH Loss of Signal Media down (E1- Break)
RbsLocalCell_CellReleaseFailur PCH ,HSDSCH ,Channels Failure Node-B
29 e Synchronization Issue

30 Remote IP Address Unreachable Remote IP Adress is Not Reachable.

RruDeviceGroup_SfpModuleHw Issue related to the SFP Module & RRU (Physically &
31 Error Configuration)

32 Synch Reference Not Reliable Synch Reference Performance Degraded.


Synch Reference is not defined, Synch Degraded,Low
33 System Clock in Holdover Mode Quality
TimDevice_RadioClockIsNotSta
34 ble Tu synch unstable, Synch fluctuate

35 TrDeviceSet_GeneralSwError Configuration Issue


TU Synch Reference Loss of
36 Signal TU Synch Fail
UpLinkBaseBandPool_ULHWLe
37 ssThanULCapacity License Capacity in LKF is more than HW Capacity
Possible Reasons/Solutions/Action Taken

Feeder Damaged,RF Connector Open, Damaged, Short,


Feeder Current High, Antenna Brnach Swap, Jumper Faulty,
Damaged, Interference,
Feeder Damaged,RF Connector Open, Damaged, Short,
Feeder Current High, Antenna Brnach Swap, Jumper Faulty,
Damaged, Interference,

MCB Trip, Voltage Degraded (Less Than -48V)


There Is No Power Supply In RRU Module, May Be Faulty
Digital Cable, SFP Module, RRU Port Faulty(Data 1 Port)

Software Package Is Not Upgraded.


Configuration Mismatch Means The SFP module Conneted to
Wrong Port may be at the RRU end or NodeB end. Configure
other Port in NodeB.
CBU Card(6601E) DUW Unit (6601W) getting the high
temperature from environment.
May be that it is not not conneted At The NODE-B & RRU End.
, May be Faulty , SFP Not Connected,
Alarm Board is not connected (Physically Not Wired)
Hardware Failure In TX Card decreases the avalable capacity
of DCH.

Commercial Licence is not loaded In NODE-B


Enclosure is not present, Door Open.
Export & delete of the site and Recreate the site

Check that the connecting cables may be loose, Defined the


HW but physically not present.
Cable Loose & Not Connected at The TNA Port of NODE-
B(Physically), Transmission Issue, CEN Router Issue(Check
out the Media Path)
Proper License is not properly loaded in NODE-B like may be
that three sectors in NODE-B but License is loaded for two
Sectors only

Only Single Synch present at the NODE-B (Tu Synch)

Timing Unit Faulty, Fault in HW, Synch reference not available

Hanging of the Node-B

Check the transmission media

Faulty RBS Configuration. Climate Units are not Configured..


May be Optical Cable faulty, SFP Module Faulty , RRU faulty
(With Port)
Check for Hanging of the Node-B, Configuration & HW Issue
Check for fault in Remote Node & IP Network configuration
related issues
Sector configured but physically not present, SFP Faulty, Not
Connected properly, Connected to the wrong Port at both ends
of NODE-B & RRU
Check for configuration, nodeB HW and transmission related
issues
Hardware fault at NODE-B End, Configuration Fault,
Transmission media related issues

Check for transmission media related issues


Export & delete of the site and Recreate the site

Check for Tu synch related transmission media

Check for correct capcity HW installation


Effect

Call Dropping, Bad Quality, KPI Degraded etc.

Call Dropping, Bad Quality, KPI Degraded etc.

Sector Down

Sector Down

Call Dropping, Bad Quality, KPI Degraded.


NODE-B & RRU both goes down or hangs when Temp.
exceeds

Sector goes Down


External ALM not received (Lock the ALM devices)

Traffic Degraded.
Data Services not working , after Emergency State
NODE-B Sector goes Down.
Dusting of NODE-B

Check the performance of HW if faulty is replaced and


also check the connecting cables

Node is not manageable and performance data


collection may be impacted

Site goes down after emergency state

After Tu Synch Fail the site goes down

Services may be impacted

If both the synchs NTP1 & NTP2 are down, the services
may be impacted
UE does not latch in 3G network

Sector goes Down

Services may be impacted

KPIs may be impacted