Академический Документы
Профессиональный Документы
Культура Документы
Product Name
The responsibilities specified shall apply as from
MSP if not otherwise stated.
The ambit of this ATP is to specify ATP for MW
Link & Network Performance, or as may be
amended or added to in accordance with Mutual
Agreement.
Site Details
Planned
Site A
Site ID MUL3570
Site Name Shastri Nagar
Site Address Kalewadi Phata, Gajanan Nagar
Site Type (Indoor/Outdoor/IBS) OUTDOOR
Locator ID
TOCO( Indus,Infratel.GTL, Bharti Owned) Indus
ToCo Site ID IN-1362794
Site Lat/Long 18.60397/73.78107
Azimuth to other site 7.05
Tower Height 30
Antenna Size (0.3, 0.6, 0.9, 1.2, 1.8 Mtrs) ML15 0.6m HP
Antenna Height (AGL- meters ) 29
Antenna Polarization (Horizontal / Vertical) (As per V
planning guidelines)
Planned
Site A
Type of Equipment (MLE/MLTN, HC, FHY, FHO,
Ceragon, NEC, Huawei, DragonWave Etc.) Ceragon
Planned
Site A
Installation Checklist
Site A
ODUs are mounted with all nuts & bolt in place and
securely tightened Yes Y No
Parameters
Signoff :
Mobile Number
Date:- 11/10/2019
V V V
NA NA NA
27K
EXITING
PACKET PACKET PACKET
1 1 1
Y Y Y Y
Y Y Y
Slot No
N N N
N N N
N
Yes
Sarjepura_AHM2956-RYASHWNT_4963
Sarjepura_AHM2956-RYASHWNT_4963
Sarjepura_AHM2956-RYASHWNT_4963
Y
FAN Faulty & Door Open
alarms of O/D Cabinet to
be extended through
MW IDU
If yes to be taken up
N N N
with planning
N N N If yes to be removed
As per Planning/OEM
N N N
suggestion
No Management/Traffic
VLAN of different Fiber
N N N POP to be configured in
one IDU
N N N
Y Y Y
Yes Y No
Yes Y No
Yes Y No
OK Not OK
Y
OK Y Not OK
OK O Not OK
K
OK Not OK
OK O Not OK
K
Yes No
Y
Yes Y No
OK Y Not OK
OK Not OK
OK Y Not OK
Yes Y No
Yes Y No
Yes Y No
Yes
Y No
Y
Yes Y No
OK Not OK
Y
Yes Y No
Yes Y No
Yes Y No
Yes No
Y
Yes No
Y
Y
Yes No
Yes Y No
Yes Y No
OK Y Not OK
Yes
Y No
Yes Y No
Yes Y No
Yes Y No
Yes Y No
Yes No
Yes No
Y Y
Mobile Number
SOFT/Physical
SOFT/Physical
SOFT/Physical
SOFT/Physical
SOFT/Physical
SOFT/Physical
SOFT/Physical
Physical
Physical
Physical
Physical
Physical
SOFT/Physical
Physical
Physical
SOFT/Physical
SOFT/Physical
SOFT/Physical
SOFT
SOFT
SOFT
SOFT
SOFT/Physical
SOFT/Physical
SOFT/Physical
Physical
Physical
Physical
SOFT/Physical
SOFT/Physical
SOFT/Physical
SOFT/Physical
Physical
Physical
Physical
Physical
Physical
Physical
Physical
SOFT/Physical
SOFT
SOFT
SOFT
SOFT
SOFT
SOFT
SOFT
SOFT
SOFT/Physical
SOFT
SOFT/Physical
SOFT/Physical
SOFT/Physical
SOFT/Physical
SOFT/Physical
SOFT
SOFT
SOFT
SOFT
SOFT
SOFT
SOFT
SOFT
SOFT
SOFT
SOFT
SOFT
SOFT
SOFT
SOFT
SOFT
SOFT
SOFT
SOFT
Physical
Physical
Physical
Physical
Physical
Physical
Physical
Physical
Physical
Physical
Physical
Physical
Physical
Physical
Physical
Physical
Physical
Physical
Physical
Physical
Physical
Physical
Physical
Physical
Physical
Physical
Physical
Physical
Physical
Physical
Physical
Physical
Physical
Physical
Physical
Physical
Physical
Physical
Physical
SOFT/Physical
SOFT/Physical
SOFT/Physical
SOFT/Physical
SOFT/Physical
SOFT/Physical
SOFT/Physical
SOFT/Physical
SR.NO
1
2
3
4
5
6
7
8
9
10
11
Snaps requried for Microwave Physical AT
ODU/Antenna is marked with far end Site ID
Labelling of IF cable at Both End, ODU, IDU, Power cable, Patch Cords ,Ethernet cables, PCM ( E1) cable, DDF, MCB e
Earthing of Magazine, ODU, IDU, Fan unit ,IF Cable/CAT6 connected to Rack/ EGB & any other TX equipment is presen
IF CONNECTOR WEATHERPROOF AND LABELLING
At ODU end the 1 Mtrs extra cable loop tightened with tower.
ODU IP SEAL IN CASE OF XPIC
IF MW >=1.2 ,SUPPORT ROD SNAP REQUIRED
In case of XPIC Huawei (CNT(cable) & OMT (Hardware )) snap required )
Protection Conduit for Patch Cords ,Interconnections, OD power cable and E1 cable routing between 2 shelters or 2 diff
IF cable/CAT6 routing is secured with IF clamps/Ties on cable tray.
Lightening arrestor Installed & Grounding of Lightening arrestor .
Installation Snap
1. OD MW SHOWING SITE ID-to B 2. OD MW SHOWING SITE ID- To A