Вы находитесь на странице: 1из 3

I describe this problem.

Phone

PABX

1,5 Km and 200 m FXS

FXO

Server

The server has a FXO and FXS cards. Fxs connected to a telephone and an FXO connected to the PABX. 
The cable used 2 types of 1.5 km and 200m. 

Step 1, When the phone is OFFHOOK, FXO also OFFHOOK. In these conditions, the end FXO was 
measured and obtained 25 mA. It was good for the state Normal cable with a distance of 1.5 km and 200 

OFFHOOK
Phone

PABX

1,5 Km FXS

FXO
End FXO = 25 mA
Server
OFFHOOK
m  

 
OFFHOOK
Phone

PABX

200 m FXS

FXO
End FXO = 25 mA
Server

OFFHOOK
 

Step 2, the phone is closed (ONHOOK) and FXO was ONHOOK. Then end FXO measured for a distance of 
1.5 km obtained was 25 mA. For cable is 200m, the results of measuring 0 mA 

ONHOOK
Phone

PABX

1,5 Km FXS

FXO
End FXO = 25 mA
Server
ONHOOK

 
ONHOOK
Phone

PABX

200 m FXS

FXO
End FXO = 0 mA
Server
ONHOOK

conclusion : 
From testing :: 
OFFHOOK : 
Cable 1.5 km = 25 mA ( end FXO ) 
Cable 200m = 25 mA ( end FXO ) 
ONHOOK : 
Cable 1.5 km = 25 mA ( end FXO ) 
Cable 200m = 0 mA ( end FXO ) 
 
Because size is 25 mA current when ONHOOK , so the position will PABX still busy when called back , it 
did not return to 0 . 
 
So I ask , How can the condition of the cables can be just 1.5 miles from the conditions in the 200m cable 
is 0 mA when ONHOOK so PABX closed? 
What to do ? Anything there is a way to solve it ? 

Вам также может понравиться