MAINTENANCE MANUAL -

TOILET SMOKE DETECTION SYSTEM - DESCRIPTION AND OPERATION

1. General ( f i g u r e I)

A. The airplane i s equipped w i t h a t o i l e t smoke detection system providing an


advisory function t o t h e crew about t h e presence o f t h e smoke in the
t o i 1e t .

B. The system consists b a s i c a l l y o f a smoke detector and a smoke d e t e c t i o n


panel f o r t h e f l i g h t attendant.

C. The system i s supplied from t h e 28 V DC BUS No. 2.

2. ~omponentD e t a i l s

A. Smoke Detector ( f i g u r e 2)

The smoke detector i s i n s t a l l e d i n t h e t o i l e t c e i l i n g .

The smoke detector operation i s based on t h e i o n i z a t i o n p r i n c i p l e .

There i s a small amount o f r a d i o a c t i v e source t h a t i o n i z e s i t s


surrounding a i r . The X - r a y s produced by t h e r a d i o a c t i v e source
ionizes t h e air i n s i d e an e l e c t r i c f i e l d between the electrodes P 1
and P2.

When a DC voltage i s a p p l i e d t o t h e electrodes, p o s i t i v e i o n s and


e l e c t r o n s move toward t h e negative and p o s i t i v e poles. It i s t h e
i o n i z a t i o n current.

When small p a r t i c l e s o f smoke enter t h e smoke detector, the ionized


a i r molecules adhere t o these p a r t i c l e s . causing the mass o f ionized
p a r t i c l e s t o increase.

I EFFECTIVITY: AIRPLANES EQUIPPED WITH


TOILET SMOKE DETECTION SYSTEM
ACFT GROUP : B
I01
Page 1
Jan 31/98
f EMBRaER
EMBIX>Brasilia
MAINTENANCE MANUAL

CAPACITOR

RESISTOR

Toi 1e t Smoke Detection System Component Location


Figure 1
Sheet 1

EFFECTIVITY: AIRPLANES EQUIPPED WITH


TOILET SMOKE DETECTION SYSTEM Page 2
I01 Jan 31/98
f EMBRAER
- EM~12oErasiln
MAINTENANCE MANUAL -

Il. II '

DET. 6

Toilet Smoke Detection System Component Location


Figure 1
Sheet 2

EFFECTIVITY: AIRPLANES EQUIPPED WITH


TOILET SMOKE DETECTION SYSTEM Page 3
1 ACFT GROUP : B I 101 Jan 31/98
E M B Brasilia
~ ~
MAINTENANCE MANUAL

DET. A

*- RAY

FiADIOACTIVE SOURCE

r---
SMOKE 1
1---- 1 SIGNAL
OUT

c-
(a) PRINCIPLE CIRCUIT
(b) EQUIVALENT ELECTRICAL CIRCUIT

120MI26159.CIT

Smoke Detector
Figure 2

I EFFECTIVITY: AIRPLANES EQUIPPED WITH


TOILET SMOKE DETECTION SYSTEM
ACFT GROUP : B
Page 4
Jan 31/98
EMBRAER

-* F\,,.%P~'
~ ~ 0 1 Brasilia
2 0
MAINTENANCE MANUAL -
(6) This increased mass of ionized p a r t i c l e s causes a decrease i n
velocity, thereby imposing a decrease t o the ionization current.

(7) The decreased ionization current, while the DC i s constant, causes


the electrical resistance between the two poles to increase too.

(8) The small variation o f electrical resistance in the ionization


chamber caused by the smoke i s so amplified t h a t a suitable output
signal i s obtained.

B. Smoke Detection Panel (figure 3)

(1) Smake detection panel location

( a ) Airplanes equipped with a f t t o i l e t

1 The smoke detection panel i s located next t o the flight


attendant's station.

(b) A i rpl anes equipped with forward toi I e t

-1 Thesmoke detection panel i s located i n the closet next to


the toilet.

(2) When the smoke detector output signal reaches an alarm level, an
aural alarm will sound and a 1i g h t will flash on the smoke detection
panel.

( 3 ) When the system i s operating properly, a green light will illurninate


on the panel. This 1 ight extinguishes when the smoke detector
produces an o u t p u t voltage at or above the alarm level.

(4) A test switch on the smoke detection panel allows a smoke condition
to be simulated and activates a1 1 associated a1 arms: aural a1 arm and
red flashing 1 i g h t . The green light remains off.

EFFECTIVITY: AIRPLANES EQUIPPED WITH


TO1 LET SMOKE DETECTION SYSTEM
26-13-00. Page 5
ACFT GROUP : B 101 Jan 31/98
f EMHRnW
EMB 120 Brasilia
MAINTENANCE MANUAL
-------a
- n**18-''1'q

OPERATION UGHT
(GREEN)

ALARM LIGHT
(RED) "4-

TEST
(INSIDE

HORN RESET SWtTCH

Smoke Detecti on Panel


Figure 3

1 EFFECTIVITY: AIRPLANES EQUIPPED WITH


TOILET SMOKE DETECTION SYSTEM
ACFT GROUP : B I01
Page 6
Jan 31/98
EMBRAER
~ ~ ~Brasilia
1 2 0
MAINTENANCE MANUAL -

(5) A reset switch i s provided t o c u t out t h e aural alarm ( i n case o f


smoke detection). Once the reset switch has been operated, the smoke
d e t e c t i o n system w i l l be ready a g a i n f o r any f u r t h e r smoke
detection.

(6) Smoke detection panel operation ( f i g u r e 4) :

(a) Power supply c i r c u i t (Block- 1)

-1 This c i r c u i t smooths input power o f 27.5 V DC t o 20 V DC and


supplies t h e smoothed power t o each c i r c u i t .

(b) F i r e detection c i r c u i t (Block-2)

-1 This c i r c u i t operates when the output o f the smoke detector


has exceeded the predetermi ned val ue.

(c) B u i l t - i n t e s t c i r c u i t (Block-3)

-1 This c i r c u i t always checks i f the output o f the smoke


detector i s w i t h i n the normal range. I f i t i s out o f the
normal range, the operation lamp i s extinguished and i n h i b i t s
the t e s t function described i n step (j).

( d l F l ashing c i r c u i t (Block-4)

-1 This c i r c u i t operates w i t h t h e alarm signal from the f i r e


detection c i r c u i t and causes the alarm l i g h t t o flash.

( e l O s c i l l a t i o n c i r c u i t (Block-5)

( f ) Aural signal control c i r c u i t (Block-6)

-1 This c i r c u i t operates w i t h t h e alarm signal from the f i r e


detection c i r c u i t and actuates t h e aural signal device
(speaker).

I EFFECTIVITY: AIRPLANES EQUIPPED WITH


TOILET SMOKE DETECTION SYSTEM
ACFT GROUP : B
Page 7
Jan 31/98
EJMBIX) Brasilia
MAINTENANCE MANUAL
(g) Indication signal transmission c i r c u i t (Block-7)

-1 This c i r c u i t operates w i t h t h e alarm signals from the f i r e


detection c i r c u i t and f l a s h i n g c i r c u i t , and gives o f f the
signal t o cause the cockpit alarm t o sound (MAP).

(h) Chime signal transmission c i r c u i t (Block-8). if appl i c a b l e

-1 This c i r c u i t operates w i t h the alarm signal from the aural


signal control c i r c u i t and gives o f f t h e signal t o cause the
a1arm t o sound on t h e fl ight attendant's panel.

(i)Horn r e s e t c i r c u i t (Block-9)

-1 This c i r c u i t operates by means o f the reset switch. This


c i r c u i t stops the operation o f the aural signal control
c i r c u i t ( a t t h e same time t h i s c i r c u i t resets t h e aural
signal transmi ssion c i r c u i t).

(j Test c i r c u i t (81ock- l o )

-1 The t e s t switch allows the operating condition o f t h e smoke


detector t o be simulated and i t s output t o be increased up t o
the l e v e l reached i n case o f f i r e ( t h e t e s t switch a1lows the
function o f the system t o be checked).

3. Operation

A. Functional Description (figures 4 and 5)

(1) I n case smoke reaches the smoke detector, t h e l a t t e r i s activated.


produci ng :

(a) Aural alarm and flashing red l i g h t on the smoke detection


panel.

EFFECTIVITY: AIRPLANES EQUIPPED WITH


Page 8
TOILET SMOKE DETECTION SYSTEM
ACFT GROUP : B I01 Jan 31/98
EM~IJK)
Emsilia
MAINTENANCE MANUAL -

Smoke Detection Panel Block Diagram


Figure 4

EFFECTIVITY : AIRPLANES EQUIPPED WITH


Page 9
TO1 LET SMOKE DETECTION SYSTEM
ACFT GROUP : B Jan 31/98
MAINTENANCE MANUAL

SMOKE DETECTOR
CEIUNG BETWEEN REF. 31-51-00
FRAMES 39 AND 40 MULT. ALARM PANEL

I
L4
0
0
n
Z
> =
(U
Q)

+ + oa Z + i
cl cn. 4
S
ii-

A0636 b DMDER B!TWEEN FRAMES 39 AND 40


SMOKE DETECTOR PANEL r;\
Smoke Detection System Schematic Diagram
Figure 5

1 EFFECTIVITY : AIRPLANES EQUIPPED WITH


26-13-00 - Page 10
TOILET SMOKE DETECTION SYSTEM
ACFT GROUP : B I01 Jan 31/98
EMBRAER
~ ~ 8 1 Brasilia
2 0
MAINTENANCE MANUAL -
(b) "Smoke" red l i g h t on the master alarm panel and "Smoke" aural
warning, both i n the cockpit.

(2) Items (a) and (b) may be reset as follows:

(a) Pressing the "HORN RESET" pushbutton on the smoke detection


panel.

(b) Pressing the "ALARM CANCEL" switch on the g l a r e s h i e l d panel (by


the p i l o t s ) .

EFFECTIVITY: AIRPLANES EQUIPPED WITH


Page 11
TOILET SMOKE DETECTION SYSTEM
ACFT GROUP : B I01 Jan 31/98