Вы находитесь на странице: 1из 6

Parameter Description Default Actual Units Minimum Maximum

Number Anti Stat Pipeline Injection-Insertion Turbine Meter & Self ARM Value Value
1 TOTPR1 Product 1 Totalizer Internal Units of Volume (Main Product) 0 9999999999
2 TOTPR2 Product 2 Totalizer Internal Units of Volume (Main Product) 0 9999999999
3 TOTPR3 Product 3 Totalizer Internal Units of Volume (Main Product) 0 9999999999
4 TOTPR4 Product 4 Totalizer Internal Units of Volume (Main Product) 0 9999999999
5 TOTPR5 Product 5 Totalizer Internal Units of Volume (Main Product) 0 9999999999
6 TOTPR6 Product 6 Totalizer Internal Units of Volume (Main Product) 0 9999999999
7 TOTPR7 Product 7 Totalizer Internal Units of Volume (Main Product) 0 9999999999
8 TOTPR8 Product 8 Totalizer Internal Units of Volume (Main Product) 0 9999999999
21 TOTPRR Product Remotely Authorized By Rate and Interval Internal Units of Volume (Main Product) 0 9999999999
22 TOTPRU Unknown Product Totalizer Internal Units of Volume (Main Product) 0 9999999999
31 TOTMPR Main Product Flow Totalizer Internal Units of Volume (Main Product) 0 9999999999
32 TOTMUN Unknown Main Product Flow Totalizer Internal Units of Volume (Main Product) 0 9999999999
37 TOTCLR Clear Product Totalizer Internal Units of Volume (Main Product) 0 9999999999
40 TOTADA Additive A Totalizer Internal Units of Volume (Additive) 0 9999999999
41 TOTADB Additive B Totalizer Internal Units of Volume (Additive) 0 9999999999
52 Totalizer Additive
60 TOTUNA Unknown Meter A (Additive) Totalizer Internal Units of Volume (Additive) 0 9999999999
61 TOTUNB Unknown Meter B (Additive) Totalizer Internal Units of Volume (Additive) 0 9999999999
70 TOTLDS Total Number of Loads Counter 0 9999999999
101 QPMPR Main Product Flow Meter Prescale Factor (K Factor) Insertion Turbine 1000 9492 Kfactor X 1000 1 65000
102 QPMCF Main Product Flow Meter Calibration Factor 10000 10000 Calibration Factor X 10,000 1 65000
108 QPART Ratio of Main Product to Additive Product Volumes 3785 3785 0 3
109 Ratio of Additive to Main Product Multiplication Factor 1 1
110 QPAPR Additive Flow Meter A Prescale (K Factor) Factor - Model 7718 Miniblock 680 600 Kfactor X 1000 1 65000
111 QPBPR Additive Flow Meter B Prescale (K Factor) Factor 680 1000 Kfactor X 1000 1 65000
114 QPCSP Calibration Mode Speed of Injection 1000 1000 Gain 1 65000
116 QPACL Maximum Volume of Additive Product for Calibration 1000 250 Internal Units of Volume (Additive) 1 65000
121 QPACF Additive A Calibration Factor 10000 3697 Calibration Factor X 10,000
122 QPBCF Additive B Calibration Factor 10000 10000 Calibration Factor X 10,000
140 QPCMD Method of Calibration 1 3 Bit Parameter
141 QPUMM Display Units for Main Product Volume - Main Product = Gallons 0 0 0=GAL 1=LIT 2=BBL 3=M3 4=LBS
143 QPUMA Display Units for Additive Volume 0 0 0=CC 1=ML 2=OZ 3=LT 4=GRAM 0 3
201 QPRD1 Definition of Product 1 1 1 Bit Parameter 0 256
202 QPRD2 Definition of Product 2 8 1 Bit Parameter 0 256
203 QPRD3 Definition of Product 3 0 1 Bit Parameter 0 256
204 QPRD4 Definition of Product 4 1 1 Bit Parameter 0 256
205 QPRD5 Definition of Product 5 1 1 Bit Parameter 0 256
206 QPRD6 Definition of Product 6 1 1 Bit Parameter 0 256
207 QPRD7 Definition of Product 7 1 1 Bit Parameter 0 256
208 QPRD8 Definition of Product 8 1 1 Bit Parameter 0 256
300 QPURI Units and Rate Interpretation (ppm) 0 0 Bit Parameter
301 QPVLA Additive A Volume Per Injection (Addtive A Set) 7cc treat rate 18 7 Internal Units of Volume (Additive) 0 65000
302 QPPRA Additive A Main Product Interval 1 (Product Set)2000 gallon inject cycle 40 2000 Internal Units of Volume (Main Product) 0 65000
303 QPSRA Additive A Main Product Interval 2 (Product Set) 40 40 Internal Units of Volume (Main Product) 0 65000
304 QPTRA Additive A Main Product Interval 3 (Product Set) 40 40 Internal Units of Volume (Main Product) 0 65000
305 QPDVA Additive A Dribble Volume 3 10 Internal Units of Volume (Additive) 0 65000
306 QPVLB Additive B Volume Per Injection (Addtive A Set) 36 36 Internal Units of Volume (Additive) 0 65000
307 QPPRB Additive B Main Product Interval 1 (Product Set) 50 50 Internal Units of Volume (Main Product) 0 65000
308 QPSRB Additive B Main Product Interval 2 (Product Set) 50 50 Internal Units of Volume (Main Product) 0 65000
309 QPTRB Additive B Main Product Interval 3 (Product Set) 50 50 Internal Units of Volume (Main Product) 0 65000
310 QPDVB Additive B Dribble Volume 3 3 Internal Units of Volume (Additive) 0 65000
396 QPFLT Flow Rate Filter Value (0,1,2 or 3) 0 0 Number of Samples 0 3
400 QPSER System Serial Number 1000 1000 Number 0 65000
403 QPFTR System Features - ProPAC 5 Injector 0 24 Bit Parameter 0 65000
407 QPCUS Customer Features - ProPAC 5 Injector 0 0 Bit Parameter 0 65000
410 QPFST Main Product Volume for 1st Injection 1 50 Internal Units of Volume (Main Product) 0 65000
412 QPSFV Main Product Volume During Slow Flow 0 0 Internal Units of Volume (Main Product) 0 65000
414 QPVCP Main Product Volume to Clear Pipes (Flush Volume) 50 50 Internal Units of Volume (Main Product) 0 65000
415 QPOVN Number of Injection Which Have Overtreat 5 5 Number of Injections 256
416 QPSLP Main Product Volume Required to Exit Sleep/Freeze State 5 5 Internal Units of Volume (Main Product) 0 65000
417 QPMXL Maximum Load Volume in Internal Units (Value X 100 = Max Volume) 65000 65000 Internal Units of Volume (Main Product) 0 65000
421 QPMIV Minimum Inject Volume in Internal Units when Rate Authorized 5 5 Internal Units of Volume (Additive) 0 65000
422 QPMXI Maximum Main Product Interval in Internal Units when Rate Authorized 250 250 Internal Units of Volume (Main Product) 0 65000
425 QPFCT Main Product Flow Meter Timeout Value 1000 150 0.1 seconds 0 65000
429 QPTSP Temporary Stop State Timeout Value 600 600 0.1 seconds 0 65000
430 QPDET Data Entry Timeout Value 300 300 0.1 seconds 0 65000
431 QPCMT Communications Timeout Value 50 50 0.1 seconds 0 65000
432 QPCTR Communications Line Turn-around delay 50 50 mS 1 256
433 QPAUT Request Authorization Timeout 600 600 0.1 seconds 0 65000
434 QPELD End of Load Volume Display Delay 150 150 0.1 seconds 0 65000
439 QPDVM Initial Dribble Volume for Main Product 0 0 Internal Units of Volume (Main Product) 0 65000
440 QPDVX Maximum Dribble Volume Allowed for Main Product 0 10 Internal Units of Volume (Main Product) 0 65000
441 QPAPD Additive Pump Turn Off Delay 100 50 0.1 seconds 0 65000
442 QPDRB Additive t Dribble Volume at End of Load 10 10 Internal Units of Volume (Additive) 0 65000
443 QPBVD Additive Block Valve Delay After Pump Start 10 10 0.1 seconds 0 65000
446 QPFRZ Maximum Time Allowed in Sleep/Freeze State 1200 1200 0.1 seconds 0 65000
453 QPFBD Inject Confirmation Pulse Length 10 10 0.1 seconds 0 65000
456 QPSHV End Product Volume to Go From Slow Flow to High Flow (Ramp Up) 100 0 Internal Units of Volume (Additive) 0 65000
457 QPHSV End Product Volume to Go From High Flow to Slow Flow (Ramp Down) 200 0 Internal Units of Volume (Additive) 0 65000
460 QPERC Maximum Number of Errors Before System Lock-up 5 20 Number of Errors 0
461 QPUMV Maximum Main Product Volume Before Unauthorized Flow Error 10 10 Internal Units of Volume (Main Product) 0 65000
463 QPUAV Maximum Additive Volume Before Unauthorized Flow Error 10 20 Internal Units of Volume (Additive) 0 65000
472 QPEDC Error Disregard Counter Over Entire Batch 3 5 Number of Injections 0 256
480 QPERK Error Checking Disable 0 0 Bit Parameter 0 16383
483 QPEDA Error Checking Disable Additive A 0 16 Bit Parameter 0 16383
484 QPEDB Error Checking Disable Additive B 0 0 Bit Parameter 0 16383
490 QPHRL Blend Ratio High Ratio Error Limit 100 100 % X 100 0
491 QPLRL Blend Ratio Low Ratio Error Limit 100 100 % X 100 0
501 QPSGN System I/O Signal Definition 0 256 Bit Parameter 0 16383
505 QPGEN Enable Signal Generation 1 2 Bit Par - Enables Product Pulse Gen on ARM 0 16383
507 QPGHF High Flow Signal Generation 1 1 Bit Par - Enables High Flow Signal on ARM 0 16383
509 QPGPR Permissive Signal Generation 1 3 Bit Parameter 0 16383
570 QPUPI Flow Rate Timer Update interval 10 10 0.1 seconds 0 65000
591 QPCBR Serial Communications Baud Rate 1 1 Bit Parameter 0 4
592 QPCED Serial Communications Error Disable 15 15 Bit Parameter 0 16383
593 QPCV1 Serial Communications Unit Address 100 100 Number (Three Digit) 0 999
594 QPTAT Serial Communications Turn Around Timer 8 8 mS 0 256
601 QPDSP Display Features (24=Idle Screen GAL & GAL 8=Idle Screen GAL & CC) 24 24 Bit Parameter 0 16383
610 Display Decimal Point & Scaling 1 1
751 Alternate Rate 1 in PPM 100 100
752 Alternate Rate 2 in PPM 200 200
753 Alternate Rate 3 in PPM 300 300
754 Alternate Rate 4 in PPM 400 400
755 Alternate Rate 5 in PPM 500 500
756 Alternate Rate 6 in PPM 600 600
757 Alternate Rate 7 in PPM 700 700
758 Alternate Rate 8 in PPM 800 800
896 QPSIM Flow Simulation Enable Bit 0 0 Bit Parameter 0 3
897 QPSMN Main Product Flow Speed of Simulation 50 50 Gain 0 65000
899 QPSAS Additive Flow Speed of Simulation 1000 1000 Gain 0 65000
901 QPVRN Firmware Version Number Read Only
902 QPREV Firmware Revision Number Read Only
Parameter 403 - System Features

BIT Sum Of: Function


BIT0 1 Disregard All Errors
BIT1 2 Disable SMART Volume Correction for Secondary Volume
BIT2 4 Disable SMART Volume Correction for Dribble Volume
BIT3 8 Start and End of Load Based on Main Product Flow and Not Enable Signal
BIT4 16 Start and Stop of Pumps Based on Main Product Flow and Not Enable Signal
BIT5 32 Flushing Initiated By Loss of HIFL Signal
BIT6 64 Reset on False Level On The Enable Signal
BIT7 128 Continuous Calibration for Additive and not Slugs
BIT8 256 Simulate Main Product Flow to Pace Additive Flow
BIT9 512 Do Not Reset Error Fail Counter on Power Up
BIT10 1024 Halt Operation and Show Error if Loss of Communications
BIT11 2048 Enable Sleep Mode
BIT12 4096 Generate PRMS in Calibration Mode

Parameter 407 - Customer Features

BIT Sum Of: Function


BIT0 1 Require PIN or Driver Number
BIT1 2 Check Validity of PIN or Driver Number
BIT2 4 Require Destination Number
BIT3 8 Require Repeat of Destination Number
BIT4 16 Require Input of Prodcut Select Code
BIT5 32 Require Input of Product Volume
BIT6 64 Require Remote Computer Authorization
BIT7 128 Require Product Select Code for Each Compartment
BIT8 256 Do Not Allow Additive A to be left in Pipes
BIT9 512 Do Not Allow Additive B to be left in Pipes
BIT10 1024 Do Not Allow Unauthorized Flow to be Shown on Display
BIT11 2048 Allow Volumes of Current Load to Change After the End of the Load
BIT12 4096 In preset mode prompt for treatment rate and not product code

Parameter 501 -System I/O Signal Definition

BIT Sum Of: Function


BIT0 1 Error Output Normally Closed - Open On Error
BIT1 2 Premissive Signal Normally Closed - Open on Enable
BIT2 4 Use Push Buttons (Preset) and Not High Flow and Product Select Inputs
BIT3 8 Use CALX (External Calibrate Signal) as PRD3 High Order Product Select
BIT4 16 Use DC Feed Back Pulse for Additive A and not PRMS
BIT5 32 Use DC Feed Back Pulse for Additive B and not ERROR
BIT6 64 Feedback Singnals are Normally Closed
BIT7 128 Output 3 is PRMS signal and not Additive A Pump Start
BIT8 256 Output 4 is ERROR signal and not Additive B Pump Start
BIT9 512 Output 3 and 4 are Additive A and Additive B Feedback and not PRMS/ERROR
BIT10 1024 Not Currently Used
Parameter 505 - Enable Signal Gerneration

Value Of: Function


1 Use External Enable Signal To Generate Armed Condition
2 Use Main Product Flow to Generate Armed Condition
3 Use Non Zero Product Selection to Generate Armed Condition
4 Not Currently Used

Parameter 507 - High Flow Signal Generation

Value Of: Function


1 Do not use External HIFL Signal - Make Same as Logical Enable Signal
2 Use External HIFL Signal
3 Use Internally Generated Computed from End of Load Volume HIFL Signal
4 Not Currently Used

Parameter 508 - Secondary Product Pump Control

Value Of: Function


1 Turn On Pumps when unit becomes armed - turn off when not armed
2 Turn On Pumps when a permissive is generated - after block valve delay
3 Turn On Pumps when main product flow has been detected
4 Not Currently Used

Parameter 509 - Permissive Signal Generation

Value Of: Function


1 Permissive Signal Made True whenever unit is Armed (Enabled)
2 Permissive Signal Made After Block Valve and Pump Start Delay
3 Permissive Signal to be True Unless Error Detected
4 Permissive Signal to be True when Under Remote Computer Control
5 Not Currently Used

Parameter 601 - Display Features

BIT Sum Of: Function


BIT0 1 Use Secondary Language
BIT1 2 Test and Display Status of End of Load
BIT2 4 Switch to Date and Time Display 15 Seconds After End of Load
BIT3 8 Show Main Product and Additive Totals at End of Load and not ppm
BIT4 16 Not Currently Used
BIT5 32 Not Currently Used
ADDR1 ADDR2 ADDR2 CMD1 CMD2 SPACE CH1 CH2 CH3 SPACE DATA
1 2 3 4 5 6 7 8 9 10 11

ADDR1 ADDR2 ADDR2 CMD1 CMD2 SPACE DATA


1 2 3 4 5 6 7

Вам также может понравиться