Вы находитесь на странице: 1из 4

Quantities for Works, 300 m3 Ground RC Circular Reservoir

BILL No.
ITE
UN QUANTIT UNIT
M DESCRIPTION AMOUNT
IT Y RATE
No.
1 EARTH WORK
Clearing the top soil and unwanted
1.1 m2 113.04
material to a depth of 200mm
Bulk excavation in ordinary soil to
1.2 m3 0.00
depth not greater than 1.5m
1.3 Extra for bulk excavation in soft rock m3 33.93
1.4 Extra for bulk excavation in hard rock. m3 22.62
Cart away all excavated material,
1.5 deposit to appropriate distance not m3 56.55
exceeding 1 km 10.00m
Provide, place and compact in layers
1.6 approved selected granular material for m3 0.00
base slab and column foundation
250 mm thick hard trachyte stone hard
1.7 m2 113.08
core
2 CONCRETE
70mm thick lean concrete class C-10
2.1 m3 7.27
under the reservoir base slab
Reinforced concrete type C-30 filled
into form work and vibrated around
reinforced bar
2.3 In 350mm thick base slab m3 33.26
2.4 In 300mm thick concrete wall m3 41.53
2.5 In 200mm top slab m3 19.00
2.6 In column of thickness 500mm dia. m3 0.88
2.7 In column cup m3 1.47
Provide and fix formwork
2.8 To base slab m2 12.31
2.9 To wall m2 289.76
2.10 To top slab m2 92.09
2.11 To column and column cup m2 10.99
Provide, cut, bend and fix in
position reinforced steel bar. All
3
according to structural drawing.
Price should include tying wires.
3.1 Diameter 8 mm deformed bar kg 4.39
3.2 Diameter 10 mm deformed bar kg 2,368.85
3.3 Diameter 12 mm deformed bar kg 3,074.93
3.4 Diameter 14 mm deformed bar kg 2,564.82
3.5 Diameter 20 mm deformed bar kg 1,087.88
Provide and construct 400 mm thick
pointed stone masonry valve chamber
4 No. 1
for inlet, outlet, overflow and drain
valves as per the drawing
4 ACCESSORIES & FINISHING
Provide and apply 50mm cement
4.1 screed to the reservoir floor and roof m2 172.71
slab and to valve chamber
Provide and apply 3 coats of plaster to
4.2 internal walls, columns and to embeded m2 148.41
part of external wall surface
4.3 Rendering external wall m2 148.41
4.4 Supply and install level gauge No 1.00
Provided and install access hatches
constructed out of 25 mm dia GS pipe
4.5 LS 1.00
and hooked to the wall as per the
drawing;
Supply andincluding safety cages
install aluminium ladder
4.6 inside the reservoir, including safety LS 1.00
cage asand
Supply per install
the drawing
steel ladder outside
the reservoir, including safety cage and
4.7 LS 1.00
extension to internal ladder as per the
Provide
drawing and install 3mm thick water
stops made of natural or synthetic
4.8 rubber or elastometric plastic m 96.59
compound with basic risen polyvinyl
chlorideand
Supply (PVC)
install aluminium manhole
4.9 No 1.00
cover for opening 800x800 mm
Hand railing complete with all
4.1 accessories and necessary works as per m 34.24
the drawing
Construction of stone pavement & drain
4.1 ditch around the building as per the m 36.12
standard drawing details.
Pipe & fitting Supply, Laying and
jointing Supply, Transport to Site
and Store, including jointing
5 materials, bolts gaskets, packing,
jointing glue etc., as
applicable.including laying and
joining.
Inlet pipesAll and
diameters
fittingsare nominal.
DN 150 DCI D/ flanged short piece pipe
5.1 pcs 2
L=0.5m
DN 150 DCI D/ flanged short piece pipe
5.2 pcs 2
L=1m
5.3 DN 150 DCI D/ flanged 900 bend pcs 4
5.4 DN 150 DCI flanged gate valve pcs 1
DN 150 DCI double flanged short pipe
5.5 pcs 2
L=3000mm
5.6 DN 150 Dismantling joint pcs 2
Overflow/drainage pipes and
fittings
DN 150 DCI D/ flanged short piece pipe
5.7 pcs 3
L=0.5m
DN 150 DCI D/ flanged short piece pipe
5.8 pcs 2
L=1m
5.9 DN 150 DCI D/ flanged 900 bend pcs 4
5.10 DN 150 DCI flanged gate valve pcs 1
DN 150 DCI double flanged short pipe
5.11 pcs 2
L=2000mm
5.12 DN 150 All flanged tee pcs 2
5.13 DN 150 Dismantling joint pcs 2
Outlet pipes and fittings
DN 250 DCI D/ flanged short piece pipe
5.14 pcs 2
L=0.5m
DN 250 DCI D/ flanged short piece pipe
5.15 pcs 2
L=1m
5.16 DN 250 DCI flanged gate valve pcs 1
5.17 DN 250 Dismantling joint pcs 2
5.18 DN 250 flanged water meter pcs 2
5.19 DN 250 strainer pcs 2
Supply and install DN 150 PVC
5.21 underground peripheral drain pipe as m 31
per the drawing
Supply and install GI pipe DN 100mm
5.22 m 6
vent pipe with cowl
6 Compound Work
Barbed wires fencing consists of 2.5
mm barbed wire horizontal and
diagonal member fixed to 2500 mm
6.1 m 170
long 50*50*4mm angle iron spaced
every 1500mm, including all necessary
material as per the drawing
Total of Bill No.Carried Summary
10.00m

10.50m
10.90m

0.20

4.50
0.25

0.30

10.90m

Вам также может понравиться