a. Saleable area
b. Non-saleable area a. 70% (maximum) a. variable a. variable
b. 30% (minimum) b. see open space requirement b. see open space requirement
as per b1, b2 & b3 as per b1, b2 & b3
Note: for row houses there shall be a maximum of 20 units but in no case shall be more than 100 meters in
length
ROADS RIGHT-OF-WAY ROW CARRIAGE ROW CARRIAGE ROW CARRIAGE
Note: 1. Interior subdivision projects must secure right-of-way to the nearest public road.
2. Subdivision projects with direct access to a main public road must provide sufficient setback to accommodate loading and unloading
passenger.
3. Subdivision project shall provide provision for further expansion.
MAXIMUM SIZES OF PROJECT
PER HIERARCHY ROADS
Major Road (each side) 1.0 m 1.0 m 1.0 m 1.0 m 1.0 m 1.0 m
Minor Road 1.0 m 1.0 m .5 m .5 m .5 m .5 m
Note: refer to supplemental rules and regulations to implement PD963 (HLURB A.O. no 2 series of 1994 (12 April)
150 liters per capita per day for 150 LCPD for 43 LCPD
Minimum water supply household connection household Handpump Same as economic housing
requirements connection
Provision for fire protection shall comply with the requirements of the National Fire Protection Code
Fire Protection
DRAINAGE SYSTEM Underground Underground for major roads, Lined open canal (sides of open
lined open canal for other roads canal shall be lined with stone rip-
rap
The drainage system must conform with the natural drainage pattern of the subdivision site and shall drain
into appropriate water bodies, public drainage system or natural outfalls
PARAMETER PD 957 BP 200 BP 220
OPEN MARKET HOUSING ECONOMIC HOUSING SOCIALIZED HOUSING
SEWAGE DISPOSAL SYSTEM
Septic Tank
Individual septic tank conforming Individual or communal septic Same as economic housing
to standard design of the tank conforming to standard
Sanitation Code design of the Sanitation Code
Connection to community Whenever applicable, connections shall be made to an approved public or community sewer system subject
sewer system to the requirements and provisions of the Sanitation Code
POWER SUPPLY Developed areas Under developed areas
Mandatory individual household Mandatory individual household Optional, however, the developer
connections to primary and connection if service is available shall allocate sufficient land area
alternate sources of power if in the locality for easements for power supply
service is available in the locality facilities based on existing laws
and regulations
Shall be in accordance to the provisions of Electrical Code and the local utility company
GARBAGE DISPOSAL SYSTEM Provide sanitary and efficient refuse collection and disposal system whether independently or in conjunction
with the local government garbage collection and disposal services
SHELTER COMPONENT
Minimum floor area
a. single-detached Shall conform with the national 22 sqm 18 sqm
building code and local zoning
ordinance
b. Duplex 22 sqm 18 sqm
c. Rowhouse 22 sqm 18 sqm
Note: Minimum floor area shall be in one floor level exclusive of
Minimum level of completion mezzanine if any.
a. single-detached
b. Duplex Complete house Complete house Shell house
c. Rowhouse Complete house Complete house Shell house
Complete house Complete house Shell house
SETBACKS / EASEMENTS