Add 2G Neighbor Cell(ADD G2GNCELL)

Function

Use this command to add a 2G neighboring internal cell.

Note

When Current HO Control Algorithm in SET GCELLHOBASIC is set to


HOALGORITHM1(Handover algorithm I), Inter-cell HO Hysteresis should be set within the
range of 64-127. When Current HO Control Algorithm in SET GCELLHOBASIC is set to
HOALGORITHM2(Handover algorithm II), Inter-cell HO Hysteresis should be set within the
range of 0-127.

Parameters

Parameter ID Paramet Parameter Description


er Name
IDTYPE Index Meaning: Index type
Type

GUI Value Range: BYNAME(By name),


BYID(By index), BYCGI(By CGI)

Unit: None

Actual Value Range: BYNAME, BYID, BYCGI

MML Default Value: None

Recommended Value: None


Parameter ID Paramet Parameter Description
er Name

Parameter Relationship: None

Service Interrupted After Modification: No (And


no impact on the UE in idle mode)

Impact on Network Performance: None


SRC2GNCELLID Source Meaning: A cell Index must be unique in one BSC
Cell
Index . It is used to uniquely identify a cell.

GUI Value Range: 0~2047

Unit: None

Actual Value Range: 0~2047

MML Default Value: None

Recommended Value: None

Parameter Relationship: None

Service Interrupted After Modification: No (And


Parameter ID Paramet Parameter Description
er Name

no impact on the UE in idle mode)

Impact on Network Performance: None


SRC2GNCELLNAME Source Meaning: Name of a cell.
Cell
Name Cell names cannot contain the following invalid
characters:

,;="'

In addition, cell names cannot contain two or more


consecutive %, two or more consecutive spaces, or
more than three consecutive +.

GUI Value Range: None

Unit: None

Actual Value Range: 1~64 characters

MML Default Value: None

Recommended Value: None

Parameter Relationship: None


Parameter ID Paramet Parameter Description
er Name

Service Interrupted After Modification: No (And


no impact on the UE in idle mode)

Impact on Network Performance: None


NBR2GNCELLID Neighbor Meaning: Uniform number of a cell index within a
2G Cell BSC
Index
, which uniquely identifies a cell.

GUI Value Range: 0~12287

Unit: None

Actual Value Range: 0~12287

MML Default Value: None

Recommended Value: None

Parameter Relationship: None

Service Interrupted After Modification: No (And


no impact on the UE in idle mode)

Impact on Network Performance: None


Parameter ID Paramet Parameter Description
er Name
NBR2GNCELLNAME Neighbor Meaning: Name of a cell.
2G Cell
Name Cell names cannot contain the following invalid
characters:

,;="'

In addition, cell names cannot contain two or more


consecutive %, two or more consecutive spaces, or
more than three consecutive +.

GUI Value Range: None

Unit: None

Actual Value Range: 1~64 characters

MML Default Value: None

Recommended Value: None

Parameter Relationship: None

Service Interrupted After Modification: No (And


no impact on the UE in idle mode)

Impact on Network Performance: None


Parameter ID Paramet Parameter Description
er Name
SRCMCC Source Meaning: Mobile country code (MCC) of the
Cell source cell
MCC

GUI Value Range: None

Unit: None

Actual Value Range: 1~3 characters

MML Default Value: None

Recommended Value: None

Parameter Relationship: None

Service Interrupted After Modification: No (And


no impact on the UE in idle mode)

Impact on Network Performance: None


SRCMNC Source Meaning: Mobile network code (MNC) of the
Cell source cell
MNC

GUI Value Range: None


Parameter ID Paramet Parameter Description
er Name

Unit: None

Actual Value Range: 1~3 characters

MML Default Value: None

Recommended Value: None

Parameter Relationship: None

Service Interrupted After Modification: No (And


no impact on the UE in idle mode)

Impact on Network Performance: None


SRCLAC Source Meaning: Local area code (LAC) of the source cell
Cell LAC

GUI Value Range: 1~65533, 65535

Unit: None

Actual Value Range: 1~65533, 65535


Parameter ID Paramet Parameter Description
er Name

MML Default Value: None

Recommended Value: None

Parameter Relationship: None

Service Interrupted After Modification: No (And


no impact on the UE in idle mode)

Impact on Network Performance: None


SRCCI Source Meaning: Source cell ID
Cell CI

GUI Value Range: 0~65535

Unit: None

Actual Value Range: 0~65535

MML Default Value: None

Recommended Value: None


Parameter ID Paramet Parameter Description
er Name

Parameter Relationship: None

Service Interrupted After Modification: No (And


no impact on the UE in idle mode)

Impact on Network Performance: None


NBRMCC Neighbo Meaning: Mobile Country Code (MCC) of a
ur Cell neighboring cell
MCC

GUI Value Range: None

Unit: None

Actual Value Range: 1~3 characters

MML Default Value: None

Recommended Value: None

Parameter Relationship: None

Service Interrupted After Modification: No (And


no impact on the UE in idle mode)
Parameter ID Paramet Parameter Description
er Name

Impact on Network Performance: None


NBRMNC Neighbo Meaning: Mobile Network Code (MNC) of a
ur Cell neighboring cell
MNC

GUI Value Range: None

Unit: None

Actual Value Range: 1~3 characters

MML Default Value: None

Recommended Value: None

Parameter Relationship: None

Service Interrupted After Modification: No (And


no impact on the UE in idle mode)

Impact on Network Performance: None


NBRLAC Neighbo Meaning: Local Area Code (LAC) of a
ur Cell neighboring cell
LAC
Parameter ID Paramet Parameter Description
er Name

GUI Value Range: 1~65533, 65535

Unit: None

Actual Value Range: 1~65533, 65535

MML Default Value: None

Recommended Value: None

Parameter Relationship: None

Service Interrupted After Modification: No (And


no impact on the UE in idle mode)

Impact on Network Performance: None


NBRCI Neighbo Meaning: Cell ID of a neighboring cell
ur Cell
CI

GUI Value Range: 0~65535

Unit: None
Parameter ID Paramet Parameter Description
er Name

Actual Value Range: 0~65535

MML Default Value: None

Recommended Value: None

Parameter Relationship: None

Service Interrupted After Modification: No (And


no impact on the UE in idle mode)

Impact on Network Performance: None


NCELLTYPE Neighbor Meaning: The parameter indicates whether the
ing Cell neighboring cell is a handover neighboring cell, an
Type IBCA neighboring cell, or a handover and IBCA
neighboring cell of the serving cell. If the
parameter is set to
HANDOVERNCELL(Handover Neighboring
Cell), the neighboring cell is the handover
neighboring cell but not the IBCA neighboring cell
of the serving cell. If the parameter is set to
IBCANCELL(IBCA Neighboring Cell), the
neighboring cell is the IBCA neighboring cell but
not the handover neighboring cell of the serving
cell. If the parameter is set to
HANDOVERANDIBCANCELL(Handover and
IBCA Neighboring Cell), the neighboring cell is
the handover neighboring cell and IBCA
neighboring cell of the serving cell. IBCA
neighboring cells are some neighboring cells of a
serving cell with its IBCA algorithm enabled.
There is co-channel or adjacent-channel
Parameter ID Paramet Parameter Description
er Name
interference between the IBCA neighboring cells
and the serving cell. Handover neighboring cells
are candidate target cells of the serving cell during
a handover.

GUI Value Range:


HANDOVERNCELL(Handover Neighboring
Cell), IBCANCELL(IBCA Neighboring Cell),
HANDOVERANDIBCANCELL(Handover and
IBCA Neighboring Cell)

Unit: None

Actual Value Range: HANDOVERNCELL,


IBCANCELL, HANDOVERANDIBCANCELL

MML Default Value:


HANDOVERNCELL(Handover Neighboring
Cell)

Recommended Value:
HANDOVERNCELL(Handover Neighboring
Cell)

Parameter Relationship: This parameter can be set


to IBCANCELL(IBCA Neighboring Cell) or
HANDOVERANDIBCANCELL(Handover and
IBCA Neighboring Cell) only if
IBCAALLOWED is set to YES(Yes) for a cell.
Parameter ID Paramet Parameter Description
er Name

Service Interrupted After Modification: No (And


no impact on the UE in idle mode)

Impact on Network Performance: None


SRCHOCTRLSWITCH Current Meaning: Whether the currently used handover
HO algorithm in the source cell is HO Algorithm I or
CTRL HO Algorithm II
Algorith
m in
Source
Cell GUI Value Range: HOALGORITHM1(Handover
algorithm I), HOALGORITHM2(Handover
algorithm II)

Unit: None

Actual Value Range: HOALGORITHM1,


HOALGORITHM2

MML Default Value:


HOALGORITHM1(Handover algorithm I)

Recommended Value:
HOALGORITHM1(Handover algorithm I)

Parameter Relationship: The value of this


parameter must be the same as that of
HOCTRLSWITCH in SET GCELLHOBASIC.
Parameter ID Paramet Parameter Description
er Name

Service Interrupted After Modification: No (And


no impact on the UE in idle mode)

Impact on Network Performance: None


INTERCELLHYST Inter-cell Meaning: Hysteresis value during the handovers
HO between cells, This value is used to suppress ping-
Hysteresi pong handovers between cells. The actual value of
s this parameter is equal to the GUI value minus 64.

GUI Value Range: 0~127

Unit: dB

Actual Value Range: -64~63

MML Default Value: 68

Recommended Value: In densely populated urban


areas, the recommended value is 68; in the
suburbs, the recommended value is 72.

Parameter Relationship: When Current HO


Control Algorithm in SET GCELLHOBASIC is
set to HOALGORITHM1(Handover algorithm I),
Inter-cell HO Hysteresis should be set within the
range of 64-127.When Current HO Control
Algorithm in SET GCELLHOBASIC is set to
HOALGORITHM2(Handover algorithm II),
Parameter ID Paramet Parameter Description
er Name

Inter-cell HO Hysteresis should be set within the


range of 0-127.

Service Interrupted After Modification: No (And


no impact on the UE in idle mode)

Impact on Network Performance: None


MINOFFSET Min Meaning: Minimum receive level offset. MSs can
Access be handed over to a neighboring cell when both of
Level the following conditions are met:
Offset
Downlink receive level of the neighboring cell is
greater than or equal to the sum of
HOCDCMINDWPWR and the value of this
parameter.

Uplink receive level of the neighboring cell is


greater than or equal to the sum of
HOCDCMINUPPWR and the value of this
parameter.

GUI Value Range: 0~63

Unit: dB

Actual Value Range: 0~63

MML Default Value: 0


Parameter ID Paramet Parameter Description
er Name

Recommended Value: 0

Parameter Relationship: This parameter is based


on HOCDCMINDWPWR and
HOCDCMINUPPWR. Different offset can be set
for different neighboring cells. The following
condition must be met for a neighboring cell to be
added into the candidate cell queue: Neighboring
cell uplink level >= (HOCDCMINUPPWR +
MINOFFSET); Neighboring cell downlink level
>= (HOCDCMINDWPWR + MINOFFSET).

Service Interrupted After Modification: No (And


no impact on the UE in idle mode)

Impact on Network Performance: None


PBGTMARGIN PBGT Meaning: Threshold for triggering PBGT
HO handovers. PBGT handovers to a neighboring cell
Threshol can be triggered when the following condition is
d met:Path loss in the serving cell - Path loss in the
neighboring cell > Actual value of this
parameter.If this parameter is set to a value less
than 64, calls can be handed over back to a
neighboring cell whose path loss is greater than
that in the serving cell. The actual value of this
parameter is equal to the GUI value minus 64.

GUI Value Range: 0~127

Unit: dB
Parameter ID Paramet Parameter Description
er Name

Actual Value Range: -64~63

MML Default Value: 68

Recommended Value: In densely populated urban


areas, the recommended value is 68; in the
suburbs, the recommended value is 72.

Parameter Relationship: This parameter is valid


only if HOCTRLSWITCH in the SET
GCELLHOBASIC command is set to
HOALGORITHM1(Handover algorithm I) and
PBGTHOEN in the SET GCELLHOBASIC
command is set to YES(Yes).

Service Interrupted After Modification: No (And


no impact on the UE in idle mode)

Impact on Network Performance: None


BQMARGIN BQ HO Meaning: Difference between the downlink
Margin receive level of the serving cell and that of a
neighboring cell during bad quality handovers.
This parameter is used to calculate the bad quality
handover hysteresis based on the following
formula:

Bad quality handover hysteresis = Value of


INTERCELLHYST -Value of this parameter

Bad quality handovers to a neighboring cell can be


triggered when the following condition is met:
Parameter ID Paramet Parameter Description
er Name

(Downlink receive level of the neighboring cell


after filtering - Downlink receive level of the
serving cell after power control compensation) >
(Value of INTERCELLHYST - 64) - (Value of
this parameter - 64). The actual value of this
parameter is equal to the GUI value minus 64.

GUI Value Range: 0~127

Unit: dB

Actual Value Range: -64~63

MML Default Value: 69

Recommended Value: 69

Parameter Relationship: This parameter is used


with INTERCELLHYST to calculate the bad
quality handover hysteresis.

Service Interrupted After Modification: No (And


no impact on the UE in idle mode)

Impact on Network Performance: None


ISCHAINNCELL Chain Meaning: Whether the cell is a chain neighboring
Parameter ID Paramet Parameter Description
er Name
Neighbor cell. The parameter is used in the quick handover
Cell algorithm. Quick handover aims to increase the
handover success rate of an MS moving at a high
speed and to ensure the call continuity and low call
drop rate. Quick handover applies to the scenario
where an MS moves fast along an urban backbone
road, a selected route, or a high-speed railroad.
The target cell must be a chain neighboring cell.

GUI Value Range: NO(No), YES(Yes)

Unit: None

Actual Value Range: NO, YES

MML Default Value: NO(No)

Recommended Value: NO(No)

Parameter Relationship: None

Service Interrupted After Modification: No (And


no impact on the UE in idle mode)

Impact on Network Performance: None


INTELEVHOHYST Adjacent Meaning: Hysteresis value during the handovers
Cell between cells on different layers or of different
Parameter ID Paramet Parameter Description
er Name
Inter- priorities. This value is used to suppress inter-layer
layer HO ping-pong handovers. The actual value of this
Hysteresi parameter is equal to the GUI value minus 64.
s

GUI Value Range: 0~127

Unit: dB

Actual Value Range: -64~63

MML Default Value: 67

Recommended Value: 67

Parameter Relationship: Inter-layer HO threshold


of the serving cell = Inter-layer HO threshold -
Inter-layer HO Hysteresis. Inter-layer HO
threshold of the neighboring cell = Inter-layer
HO threshold + Adjacent Cell Inter-layer HO
Hysteresis - 64. The value of Inter-layer HO
threshold can be set through SET
GCELLHOBASIC.

Service Interrupted After Modification: No (And


no impact on the UE in idle mode)

Impact on Network Performance: None


Parameter ID Paramet Parameter Description
er Name
DRHOLEVRANGE Directed Meaning: Difference between the downlink
Retry receive level of the serving cell and that of a
Handove neighboring cell during handovers due to directed
r Level retry. In the case of Huawei handover algorithm II,
Range this parameter is used to calculate the hysteresis of
handovers due to directed retry based on the
following formula:

Hysteresis of handovers due to directed retry =


Value of INTERCELLHYST - Value of this
parameter

Handovers due to directed retry to a neighboring


cell can be triggered when the following condition
is met:

(Downlink receive level of the neighboring cell


after filtering - Downlink receive level of the
serving cell after power control compensation) >
(Value of INTERCELLHYST - 64) - (Value of
this parameter - 64).If EDGEHOHYSTEN in the
SET GCELLHOBASICcommand is set to YES,
INTERCELLHYST is replaced by
EDGEHOHYST.

GUI Value Range: 0~128

Unit: dB

Actual Value Range: 0~128

MML Default Value: 72


Parameter ID Paramet Parameter Description
er Name

Recommended Value: 72

Parameter Relationship: 1. This parameter is valid


only if HOCTRLSWITCH in the SET
GCELLHOBASIC command is set to
HOALGORITHM2 and DIRECTRYEN in the
SET GCELLBASICPARA command is set to
YES. 2. INTERCELLHYST and
EDGEHOHYST together determine the direct
retry handover hysteresis.

Service Interrupted After Modification: No (And


no impact on the UE in idle mode)

Impact on Network Performance: None


CHAINNCELLTYPE Chain Meaning: This parameter indicates the
Neighbo geographical relationship between the neighboring
ur Cell cell and the serving cell. In the BSC, if direction A
Type is selected, then the reverse direction is B.

GUI Value Range:


QUICK_HO_NCELL_TYPE_A(QUICK_HO_NC
ELL_TYPE_A),
QUICK_HO_NCELL_TYPE_B(QUICK_HO_NC
ELL_TYPE_B)

Unit: None

Actual Value Range:


QUICK_HO_NCELL_TYPE_A,
Parameter ID Paramet Parameter Description
er Name

QUICK_HO_NCELL_TYPE_B

MML Default Value:


QUICK_HO_NCELL_TYPE_A(QUICK_HO_NC
ELL_TYPE_A)

Recommended Value:
QUICK_HO_NCELL_TYPE_A(QUICK_HO_NC
ELL_TYPE_A)

Parameter Relationship: None

Service Interrupted After Modification: No (And


no impact on the UE in idle mode)

Impact on Network Performance: The setting of


this parameter depends on the actual physical
location of the chain neighboring cell. Otherwise,
fast PBGT handover fails.
EDGEADJSTATTIME Edge HO Meaning: According to the P/N rule, if a neighbor
AdjCell cell meets the conditions for selecting the neighbor
Watch cell for edge handover in P of N measurement
Time reports, the edge handover to the neighbor cell is
triggered.

This parameter specifies the number N.

GUI Value Range: 1~32


Parameter ID Paramet Parameter Description
er Name

Unit: 0.5s

Actual Value Range: 0.5~16

MML Default Value: 6

Recommended Value: 6

Parameter Relationship: This parameter is valid


only if FRINGEHOEN in the SET
GCELLHOBASIC command is set to
YES(Yes).The parameter value must meet the
following requirement:EDGEADJSTATTIME
>= EDGEADJLASTTIME.

Service Interrupted After Modification: No (And


no impact on the UE in idle mode)

Impact on Network Performance: None


EDGEADJLASTTIME Edge HO Meaning: According to the P/N rule, if a neighbor
AdjCell cell meets the conditions for selecting the neighbor
Valid cell for edge handover in P of N measurement
Time reports, the edge handover to the neighbor cell is
triggered.

This parameter specifies the number P.


Parameter ID Paramet Parameter Description
er Name

GUI Value Range: 1~32

Unit: 0.5s

Actual Value Range: 0.5~16

MML Default Value: 4

Recommended Value: 4

Parameter Relationship: This parameter is valid


only if FRINGEHOEN in the SET
GCELLHOBASIC command is set to YES(Yes).
The parameter value must meet the following
requirement: EDGEADJSTATTIME >=
EDGEADJLASTTIME.

Service Interrupted After Modification: No (And


no impact on the UE in idle mode)

Impact on Network Performance: 1. If this


parameter is set to a large value, an MS needs to
wait a long time before performing a handover. As
a result, voice quality deteriorates or the call drop
rate increases. 2. If this parameter is set to a small
value, an MS performs handovers frequently,
leading to unnecessary handovers.
LEVSTAT Layer Meaning: The triggering of inter-layer handovers
Parameter ID Paramet Parameter Description
er Name
HO must meet the P/N criteria. An inter-layer
Watch handover is triggered when P of N measurement
Time reports meet the condition for inter-layer
handovers. This parameter corresponds to the N in
the P/N criteria.

GUI Value Range: 1~32

Unit: 0.5s

Actual Value Range: 0.5~16

MML Default Value: 6

Recommended Value: 6

Parameter Relationship: This parameter is valid


only when HOCTRLSWITCH is set to
HOALGORITHM1 and LEVHOEN is set to
YES. The following condition must be met:
LEVSTAT >= LEVLAST.

Service Interrupted After Modification: No (And


no impact on the UE in idle mode)

Impact on Network Performance: If this parameter


is set to a large value, unnecessary handovers are
performed, deteriorating the speech quality and
Parameter ID Paramet Parameter Description
er Name
causing ping-pong handovers. If this parameter is
set to a small value, congestion occurs in the
macro cell.
LEVLAST Layer Meaning: The triggering of inter-layer handovers
HO Valid must meet the P/N criteria. An inter-layer
Time handover is triggered when P of N measurement
reports meet the condition for inter-layer
handovers. This parameter corresponds to the P in
the P/N criteria.

GUI Value Range: 1~32

Unit: 0.5s

Actual Value Range: 0.5~16

MML Default Value: 4

Recommended Value: 4

Parameter Relationship: This parameter is valid


only when HOCTRLSWITCH is set to
HOALGORITHM1 and LEVHOEN is set to
YES. The following condition must be met:
LEVSTAT >= LEVLAST.

Service Interrupted After Modification: No (And


Parameter ID Paramet Parameter Description
er Name

no impact on the UE in idle mode)

Impact on Network Performance: If this parameter


is set to a large value, congestion occurs in macro
cells. If this parameter is set to a small value,
unnecessary handovers are performed,
deteriorating the speech quality and causing ping-
pong handovers.
PBGTSTAT PBGT Meaning: The triggering of PBGT handovers must
Watch meet the P/N criteria. A PBGT handover is
Time triggered when P of N measurement reports meet
the condition for PBGT handovers. This parameter
corresponds to the N in the P/N criteria.

GUI Value Range: 1~32

Unit: 0.5s

Actual Value Range: 0.5~16

MML Default Value: 6

Recommended Value: 6

Parameter Relationship: This parameter is valid


only when HOCTRLSWITCH is set to
HOALGORITHM1 and PBGTHOEN is set to
YES. The following condition must be met:
Parameter ID Paramet Parameter Description
er Name

PBGTSTAT >= PBGTLAST.

Service Interrupted After Modification: No (And


no impact on the UE in idle mode)

Impact on Network Performance: If this parameter


is set to a large value, unnecessary handovers are
likely to perform. If this parameter is set to a small
value, handovers are unlikely to perform in a
timely manner, causing call drops.
PBGTLAST PBGT Meaning: The triggering of PBGT handovers must
Valid meet the P/N criteria. A PBGT handover is
Time triggered when P of N measurement reports meet
the condition for PBGT handovers. This parameter
corresponds to the P in the P/N criteria.

GUI Value Range: 1~32

Unit: 0.5s

Actual Value Range: 0.5~16

MML Default Value: 4

Recommended Value: 4
Parameter ID Paramet Parameter Description
er Name

Parameter Relationship: This parameter is valid


only when HOCTRLSWITCH is set to
HOALGORITHM1 and PBGTHOEN is set to
YES. The following condition must be met:
PBGTSTAT >= PBGTLAST.

Service Interrupted After Modification: No (And


no impact on the UE in idle mode)

Impact on Network Performance: If this parameter


is set to a large value, handovers cannot be
performed in a timely manner, causing call drops.
If this parameter is set to a small value,
unnecessary handovers are performed.
BETTERCELLSTATTIME Better Meaning: Period during which handovers to a
Cell HO better cell are measured. According to the P/N
Watch rule, handovers to a better cell can be triggered
Time when the conditions for handovers to a better cell
are met for P seconds within N seconds. This
parameter specifies N in the P/N rule.

GUI Value Range: 1~32

Unit: 0.5s

Actual Value Range: 0.5~16

MML Default Value: 6


Parameter ID Paramet Parameter Description
er Name

Recommended Value: 6

Parameter Relationship: This parameter is valid


only when BETTERCELLHOEN is set to YES
and HOCTRLSWITCH is set to
HOALGORITHM2. The following condition must
be met: BETTERCELLSTATTIME >=
BETTERCELLLASTTIME.

Service Interrupted After Modification: No (And


no impact on the UE in idle mode)

Impact on Network Performance: If this parameter


is set to a large value, unnecessary handovers are
triggered. If this parameter is set to a small value,
handovers cannot be performed in a timely
manner, affecting voice quality or causing call
drops.
BETTERCELLLASTTIME Better Meaning: Period during which the conditions for
Cell HO handovers to a better cell are met. According to the
Valid P/N rule, handovers to a better cell can be
Time triggered when the conditions for handovers to a
better cell are met for P seconds within N seconds.
This parameter specifies P in the P/N rule.

GUI Value Range: 1~32

Unit: 0.5s
Parameter ID Paramet Parameter Description
er Name

Actual Value Range: 0.5~16

MML Default Value: 4

Recommended Value: 4

Parameter Relationship: This parameter is valid


only when BETTERCELLHOEN is set to YES
and HOCTRLSWITCH is set to
HOALGORITHM2. The following condition must
be met: BETTERCELLSTATTIME >=
BETTERCELLLASTTIME.

Service Interrupted After Modification: No (And


no impact on the UE in idle mode)

Impact on Network Performance: If this parameter


is set to a large value, handovers cannot be
performed in a timely manner, affecting voice
quality or causing call drops. If this parameter is
set to a small value, unnecessary handovers are
triggered.
HOSTATICTIME Quick Meaning: According to the P/N rule, if the
Handove conditions for fast handover are met in P of N
r Static measurement reports, the handover is triggered.
Time
This parameter specifies the number N.

GUI Value Range: 1~32


Parameter ID Paramet Parameter Description
er Name

Unit: 0.5s

Actual Value Range: 0.5~16

MML Default Value: 4

Recommended Value: 4

Parameter Relationship: This parameter is valid


only when QUICKHOEN in SET
GCELLHOBASIC is set to YES. The following
condition must be met: HOSTATICTIME >=
HOLASTTIME.

Service Interrupted After Modification: No (And


no impact on the UE in idle mode)

Impact on Network Performance: If this parameter


is set to a large value, handovers cannot be
performed in a timely manner, causing call drops.
If this parameter is set to a small value,
unnecessary handovers are triggered.
HOLASTTIME Quick Meaning: According to the P/N rule, if the
Handove conditions for fast handover are met in P of N
r Last measurement reports, the handover is triggered.
Time
This parameter specifies the number P.
Parameter ID Paramet Parameter Description
er Name

GUI Value Range: 1~32

Unit: 0.5s

Actual Value Range: 0.5~16

MML Default Value: 3

Recommended Value: 3

Parameter Relationship: This parameter is valid


only when QUICKHOEN in SET
GCELLHOBASIC is set to YES. The following
condition must be met: HOSTATICTIME >=
HOLASTTIME.

Service Interrupted After Modification: No (And


no impact on the UE in idle mode)

Impact on Network Performance: If this parameter


is set to a large value, handovers cannot be
performed in a timely manner, causing call drops.
If this parameter is set to a small value,
unnecessary handovers are triggered.
HCSSTATTIME HCS HO Meaning: According to the P/N rule, if the
Watch conditions for the handover to a different micro
Time cell due to fast movement are met in P of N
Parameter ID Paramet Parameter Description
er Name
measurement reports, the handover is triggered.

This parameter specifies the number N.

GUI Value Range: 1~16

Unit: 0.5s

Actual Value Range: 0.5~8

MML Default Value: 3

Recommended Value: 3

Parameter Relationship: This parameter is valid


only if HOCTRLSWITCH in the SET
GCELLHOBASIC command is set to
HOALGORITHM2(Handover algorithm II) and
QCKMVHOEN in the SET GCELLHOBASIC
command is set to YES(Yes).The parameter value
must meet the following
requirement:HCSSTATTIME >=
HCSLASTTIME.

Service Interrupted After Modification: No (And


no impact on the UE in idle mode)

Impact on Network Performance: If this parameter


Parameter ID Paramet Parameter Description
er Name
is set to a large value, congestion occurs in macro
cells. If this parameter is set to a small value,
handovers cannot be performed in a timely
manner, causing call drops or more handovers.
HCSLASTTIME HCS HO Meaning: According to the P/N rule, if the
Valid conditions for the handover to a different micro
Time cell due to fast movement are met in P of N
measurement reports, the handover is triggered.

This parameter specifies the number P.

GUI Value Range: 1~16

Unit: 0.5s

Actual Value Range: 0.5~8

MML Default Value: 2

Recommended Value: 2

Parameter Relationship: This parameter is valid


only if HOCTRLSWITCH in the SET
GCELLHOBASIC command is set to
HOALGORITHM2(Handover algorithm II) and
QCKMVHOEN in the SET GCELLHOBASIC
command is set to YES(Yes).The parameter value
must meet the following
requirement:HCSSTATTIM >=
Parameter ID Paramet Parameter Description
er Name

HCSLASTTIME.

Service Interrupted After Modification: No (And


no impact on the UE in idle mode)

Impact on Network Performance: If this parameter


is set to a large value, handovers cannot be
performed in a timely manner, causing call drops
or more handovers. If this parameter is set to a
small value, congestion occurs in macro cells.
BQSTATTIME BQ HO Meaning: According to the P/N rule, if the
Watch conditions for emergency BQ handover are met in
Time P of N measurement reports, the handover is
triggered.

This parameter specifies the number N.

GUI Value Range: 1~16

Unit: 0.5s

Actual Value Range: 0.5~8

MML Default Value: 1

Recommended Value: 1
Parameter ID Paramet Parameter Description
er Name

Parameter Relationship: This parameter is valid


only when BQHOEN is set to YES and
HOCTRLSWITCH is set to HOALGORITHM2.
The following condition must be met:
BQSTATTIME >= BQLASTTIME.

Service Interrupted After Modification: No (And


no impact on the UE in idle mode)

Impact on Network Performance: If this parameter


is set to a large value, unnecessary handovers are
triggered. If this parameter is set to a small value,
handovers cannot be performed in a timely
manner, affecting voice quality or causing call
drops.
BQLASTTIME BQ HO Meaning: According to the P/N rule, if the
Valid conditions for emergency BQ handover are met in
Time P of N measurement reports, the handover is
triggered.

This parameter specifies the number P.

GUI Value Range: 1~16

Unit: 0.5s

Actual Value Range: 0.5~8

MML Default Value: 1


Parameter ID Paramet Parameter Description
er Name

Recommended Value: 1

Parameter Relationship: This parameter is valid


only when BQHOEN is set to YES and
HOCTRLSWITCH is set to HOALGORITHM2.
The following condition must be met:
BQSTATTIME >= BQLASTTIME.

Service Interrupted After Modification: No (And


no impact on the UE in idle mode)

Impact on Network Performance: If this parameter


is set to a large value, handovers cannot be
performed in a timely manner, affecting voice
quality or causing call drops. If this parameter is
set to a small value, unnecessary handovers are
triggered.
TASTATTIME TA HO Meaning: The P/N criterion must be met for
Watch triggering a TA handover. That is, the TA handover
Time can be triggered only if P measurement reports
among N measurement reports meet the triggering
conditions. This parameter corresponds to N in the
P/N criterion.

GUI Value Range: 1~16

Unit: 0.5s
Parameter ID Paramet Parameter Description
er Name

Actual Value Range: 0.5~0.8

MML Default Value: 1

Recommended Value: 1

Parameter Relationship: This parameter is valid


only when TAHOEN is set to YES and
HOCTRLSWITCH is set to HOALGORITHM2.
The following condition must be met:
TASTATTIME >= TALASTTIME.

Service Interrupted After Modification: No (And


no impact on the UE in idle mode)

Impact on Network Performance: If this parameter


is set to a large value, an MS performs handovers
frequently, leading to unnecessary handovers. If
this parameter is set to a small value, an MS needs
to wait a long time before performing a handover.
As a result, voice quality deteriorates or the call
drop rate increases.
TALASTTIME TA HO Meaning: The P/N criterion must be met for
Valid triggering a TA handover. That is, the TA handover
Time can be triggered only if P measurement reports
among N measurement reports meet the triggering
conditions. This parameter corresponds to P in the
P/N criterion.
Parameter ID Paramet Parameter Description
er Name

GUI Value Range: 1~16

Unit: 0.5s

Actual Value Range: 0.5~8

MML Default Value: 1

Recommended Value: 1

Parameter Relationship: This parameter is valid


only when HOCTRLSWITCH is set to
HOALGORITHM2 and TAHOEN is set to YES.
The following condition must be met:
TASTATTIME >= TALASTTIME.

Service Interrupted After Modification: No (And


no impact on the UE in idle mode)

Impact on Network Performance: If this parameter


is set to a large value, handovers cannot be
performed in a timely manner, causing call drops.
If this parameter is set to a small value,
unnecessary handovers are triggered.
ULBQSTATTIME UL BQ Meaning: Period during which handovers without
HO a downlink measurement report are measured.
Static According to the P/N rule, handovers without a
Time downlink measurement report can be triggered
Parameter ID Paramet Parameter Description
er Name
when the conditions for handovers without a
downlink measurement report are met for P
seconds within N seconds. This parameter
specifies N in the P/N rule.

GUI Value Range: 1~8

Unit: 0.5s

Actual Value Range: 0.5~4

MML Default Value: 1

Recommended Value: 1

Parameter Relationship: This parameter is valid


only if HOCTRLSWITCH in the SET
GCELLHOBASIC command is set to
HOALGORITHM2(Handover algorithm II) and
NODLMRHOEN in the SET GCELLHOEMG
command is set to YES(Yes).The parameter value
must meet the following
requirement:ULBQSTATTIME >=
ULBQLASTTIME.

Service Interrupted After Modification: No (And


no impact on the UE in idle mode)
Parameter ID Paramet Parameter Description
er Name
Impact on Network Performance: If this parameter
is set to a large value, unnecessary handovers are
triggered. If this parameter is set to a small value,
handovers cannot be performed in a timely
manner, causing call drops.
ULBQLASTTIME UL BQ Meaning: Period during which the conditions for
HO Last handovers without a downlink measurement
Time report. According to the P/N rule, handovers
without a downlink measurement report can be
triggered when the conditions for handovers
without a downlink measurement report are met
for P seconds within N seconds. This parameter
specifies P in the P/N rule.

GUI Value Range: 1~8

Unit: 0.5s

Actual Value Range: 0.5~4

MML Default Value: 1

Recommended Value: 1

Parameter Relationship: This parameter is valid


only if HOCTRLSWITCH in the SET
GCELLHOBASIC command is set to
HOALGORITHM2(Handover algorithm II) and
NODLMRHOEN in the SET GCELLHOEMG
command is set to YES(Yes).The parameter value
Parameter ID Paramet Parameter Description
er Name

must meet the following


requirement:ULBQSTATTIME >=
ULBQLASTTIME.

Service Interrupted After Modification: No (And


no impact on the UE in idle mode)

Impact on Network Performance: If this parameter


is set to a large value, handovers cannot be
performed in a timely manner, causing call drops.
If this parameter is set to a small value,
unnecessary handovers are triggered.
IBCADYNCMEASURENCELL IBCA Meaning: Flag that indicates whether an IBCA
ALLOWED Dyn neighboring cell is to be measured dynamically.
Measure This parameter is set to Yes if the information
Neighbo about a neighboring cell cannot be reported
ur Cell through measurement reports but the interference
Flag of the neighboring cell cannot be ignored.
Otherwise, this parameter is set to No. This
parameter is set to Yes for the neighboring cell
with co-channel interference and the neighboring
cells that cause interference, while this parameter
is set to No for other neighboring cells.

GUI Value Range: NO(No), YES(Yes)

Unit: None

Actual Value Range: NO, YES


Parameter ID Paramet Parameter Description
er Name

MML Default Value: NO(No)

Recommended Value: Set this parameter to YES


for the neighboring cell with co-channel
interference and the neighboring cell that cause
interference; set this parameter to NO for other
neighboring cells.

Parameter Relationship: This parameter is valid


only if NCELLTYPE is set to
IBCANCELL(IBCA Neighboring Cell) or
HANDOVERANDIBCANCELL(Handover and
IBCA Neighboring Cell).

Service Interrupted After Modification: No (And


no impact on the UE in idle mode)

Impact on Network Performance: None


IBCARXLEVOFFSET IBCA Meaning: Unmeasured receive level of IBCA
RxLev neighboring cells. If the number of neighboring
Offset cells reported in consecutive N measurement
reports (N is specified by
IBCANONMEANCELLSTATNUM) is smaller
than that of the actually configured neighboring
cells, this parameter is used to estimate the
unmeasured receive level of IBCA neighboring
cells. The estimated value is equal to the value of
IBCANCELLPATHLOSSESTIMATE or the
signal level of the unmeasured IBCA neighboring
cells is the measured signal level of the
neighboring cells (including non-IBCA
neighboring cells) minus the value of
IBCARXLEVOFFSET.
Parameter ID Paramet Parameter Description
er Name

GUI Value Range: 0~63

Unit: dB

Actual Value Range: 0~63

MML Default Value: 4

Recommended Value: 4

Parameter Relationship: This parameter is valid


only if NCELLTYPE is set to
IBCANCELL(IBCA Neighboring Cell) or
HANDOVERANDIBCANCELL(Handover and
IBCA Neighboring Cell).

Service Interrupted After Modification: No (And


no impact on the UE in idle mode)

Impact on Network Performance: None


LOADHOPBGTMARGIN Load HO Meaning: Threshold for triggering load-based
PBGT PBGT handovers. Load-based PBGT handovers to
Threshol a candidate cell can be triggered when the path
d loss in the serving cell minus that in a candidate
cell is greater than the value of this parameter. This
parameter loosens the requirement of the load-
based PBGT handover threshold when the load of
Parameter ID Paramet Parameter Description
er Name
the serving cell reaches a specified level. Certain
traffic that could not be handed over back to a
neighboring cell during PBGT handovers can be
handed over now. If this parameter is set to 0,
enhanced load-based handovers to the neighboring
cell cannot be triggered.

GUI Value Range: 0~127

Unit: dB

Actual Value Range: -64~63

MML Default Value: 0

Recommended Value: 0

Parameter Relationship: The parameter value


cannot be larger than the value of PBGT HO
Threshold. The parameter takes effect only when
Enhanced Load HO Allowed is enabled.

Service Interrupted After Modification: No (And


no impact on the UE in idle mode)

Impact on Network Performance: If this parameter


is set to a small value, unnecessary handovers are
performed. If this parameter is set to a large value,
Parameter ID Paramet Parameter Description
er Name
handovers are delayed, increasing the congestion
rate in the serving cell.
NCELLPRI Neighbor Meaning: Common priority of the neighboring 2G
ing Cell cell. Value 0 indicates the lowest priority, and
Priority value 7 indicates the highest priority. Value 255 is
invalid.

GUI Value Range: 0~7, 255

Unit: None

Actual Value Range: 0~7, 255

MML Default Value: 255

Recommended Value: None

Parameter Relationship: If this parameter is set to


a value except 255, the value of this parameter
must be different from the values of NCELLPRI
of all neighboring UTRAN and EUTRAN cells,
and UTRANPRI and EUTRANPRI of the
serving cell.

Service Interrupted After Modification: No (And


no impact on the UE in idle mode)
Parameter ID Paramet Parameter Description
er Name
Impact on Network Performance: None
EDOUTHOOFFSET Enhance Meaning: Level offset for the serving cell when
d handovers to the edge of a neighboring cell are
Outgoing triggered.
Cell
Handove When both Enhanced Outgoing Cell Handover
r Offset Offset and EDGE HO Allowed are set to
YES(Yes) for a cell, the BSC takes the value of
this parameter into account when deciding to
trigger an edge handover. That is, handovers to the
edge of a neighboring cell can be triggered when
either of the following condition is met:

Uplink receive level of the serving cell after power


control compensation < Value of
ULEDGETHRES + Value of this parameter - 64

Downlink receive level of the serving cell after


power control compensation < Value
ofDLEDGETHRES + Value of this parameter -
64

In the case of Huawei handover algorithm II,


handovers to a better neighboring cell can be
triggered when both of the following conditions
are met:

Enhanced Outgoing Cell Handover Offset is set


to YES(Yes).

Receive level of the serving cell after power


control compensation < Value of HOTHRES -
(Value of LEVHOHYST + Value of this
parameter - 64). The actual value of this parameter
is equal to the GUI value minus 64.

GUI Value Range: 0~127


Parameter ID Paramet Parameter Description
er Name

Unit: None

Actual Value Range: -64~63

MML Default Value: 64

Recommended Value: 64

Parameter Relationship: 1. This parameter is used


with DLEDGETHRES or ULEDGETHRES to
determine handovers to the edge of a neighboring
cell only if both Enhanced Outgoing Cell
Handover Offset and EDGE HO Allowed are set
to YES(Yes). 2. This parameter is used with
LEVHOHYST and HOTHRES to determine
handovers to a better neighboring cell only if
Enhanced Outgoing Cell Handover Offset is set
to YES(Yes) and HOCTRLSWITCH is set to
HOALGORITHM2(Handover algorithm II).

Service Interrupted After Modification: No (And


no impact on the UE in idle mode)

Impact on Network Performance: None


NCELLPUNEN Neighbor Meaning: Whether to apply penalty on a
ing Cell neighboring cell when the PBGT handover,
Penalty concentric cell handover, or hierarchical handover
Switch in handover algorithm I is triggered, or when the
better cell handover in handover algorithm II is
triggered. This prevents a call from experiencing
Parameter ID Paramet Parameter Description
er Name
ping-pong handovers.

GUI Value Range: NO(No), YES(Yes)

Unit: None

Actual Value Range: NO, YES

MML Default Value: NO(No)

Recommended Value: NO(No)

Parameter Relationship: 1. If HOCTRLSWITCH


in the SET GCELLHOBASIC command is set to
HOALGORITHM1, and PBGTHOEN,
LEVHOEN, CONHOEN are set to YES, this
parameter is valid. 2. If HOCTRLSWITCH in
the SET GCELLHOBASIC command is set to
HOALGORITHM2, and BETTERCELLHOEN
is set to YES, this parameter is valid.

Service Interrupted After Modification: No (And


no impact on the UE in idle mode)

Impact on Network Performance: None


NCELLPUNSTPTH Penalty Meaning: Level threshold used to stop the timer
Stop for performing penalties in a neighboring cell
Parameter ID Paramet Parameter Description
er Name
Level during the PBGT handover, concentric cell
Threshol handover, or hierarchical handover in the case of
d Huawei handover algorithm I or during better cell
handovers in the case of Huawei handover
algorithm II.

If the BCCH receive level of the neighboring cell


is lower than this threshold, the penalties will be
stopped.

GUI Value Range: 0~63

Unit: dB

Actual Value Range: 0~63

MML Default Value: 20

Recommended Value: 20

Parameter Relationship: This parameter is valid


only if NCELLPUNEN is set to YES(Yes).

Service Interrupted After Modification: No (And


no impact on the UE in idle mode)

Impact on Network Performance: None


Parameter ID Paramet Parameter Description
er Name
NCELLPUNTM Penalty Meaning: Length of the timer for performing
Timer penalties in a neighboring cell during PBGT,
Length concentric cell handover, or hierarchical handovers
in the case of Huawei handover algorithm I or
during better cell handovers in the case of Huawei
handover algorithm II.

GUI Value Range: 0~255

Unit: s

Actual Value Range: 0~255

MML Default Value: 10

Recommended Value: 10

Parameter Relationship: This parameter is valid


only if NCELLPUNEN is set to YES(Yes).

Service Interrupted After Modification: No (And


no impact on the UE in idle mode)

Impact on Network Performance: None


NCELLPUNLEV Level Meaning: Level for penalties in a neighboring cell
Penalty during PBGT handover, concentric cell handover,
Value on or hierarchical handover in the case of Huawei
Parameter ID Paramet Parameter Description
er Name
Neighbor handover algorithm I or during better cell
ing Cell handovers in the case of Huawei handover
algorithm II.

GUI Value Range: 0~63

Unit: dB

Actual Value Range: 0~63

MML Default Value: 10

Recommended Value: 10

Parameter Relationship: This parameter is valid


only if NCELLPUNEN is set to YES(Yes).

Service Interrupted After Modification: No (And


no impact on the UE in idle mode)

Impact on Network Performance: None


ADJHOOFFSET Quick Meaning: This parameter is used as the offset for
Handove HOOFFSET (for SET GCELLHOFAST in the
r Offset case of internal neighboring cells or for MOD
for GEXT2GCELL in the case of external
Neighbor neighboring cells)during handover decision. Quick
Cell handover can be triggered only when the path loss
Parameter ID Paramet Parameter Description
er Name
difference between the serving cell and a chain
neighboring cell is larger than the quick handover
trigger threshold. The quick handover trigger
threshold is the sum of HOOFFSET(for SET
GCELLHOFAST in the case of internal
neighboring cells or for MOD GEXT2GCELL in
the case of external neighboring cells) and
ADJHOOFFSET configured by the neighboring
cell.

GUI Value Range: 0~127

Unit: dB

Actual Value Range: 0~127

MML Default Value: 0

Recommended Value: 0

Parameter Relationship: The sum of


ADJHOOFFSET and HOOFFSET (for SET
GCELLHOFAST in the case of internal
neighboring cells or for MOD GEXT2GCELL in
the case of external neighboring cells) should be
less than or equal to 127. If the sum is greater than
127, it is processed as 127.

Service Interrupted After Modification: No (And


Parameter ID Paramet Parameter Description
er Name

no impact on the UE in idle mode)

Impact on Network Performance: If this parameter


is set to a large value, call drops occur because the
handover is not performed in a timely manner.
EDGEHOHYST Edge HO Meaning: Hysteresis used for an inter-cell
Hysteresi handover decision when handover algorithm II is
s used. For an MS with low receive level, the
receive level of the neighboring cell must be
higher than the receive level of the serving cell
plus the value of this parameter.

GUI Value Range: 0~127

Unit: dB

Actual Value Range: 0~127

MML Default Value: 68

Recommended Value: 67

Parameter Relationship: This parameter is valid


only if EDGEHOHYSTEN in SET
GCELLHOBASIC is set to YES(Yes). The value
of this parameter must be less than or equal to
INTERCELLHYST.
Parameter ID Paramet Parameter Description
er Name

Service Interrupted After Modification: No (And


no impact on the UE in idle mode)

Impact on Network Performance: If this parameter


is set to a large value, the number of handover
requests sent by the MS with low receive level
decreases. If this parameter is set to a small value,
the number of handover requests sent by the MS
with low receive level increases.

Example

To add a neighboring cell (IDTYPE = Index Type , Source Cell Name = Cell000,
Neighbor 2G Cell Name = cell002;
Inter-cell HO Hysteresis = 50; Min Access Level Offset = 60;
Adjacent Cell Inter-layer HO Hysteresis = 68), run the following command:
ADD G2GNCELL: IDTYPE=BYNAME, SRC2GNCELLNAME="Cell000",
NBR2GNCELLNAME="cell002", NCELLTYPE=HANDOVERNCELL, INTERCELLHYST=50,
MINOFFSET=60, INTELEVHOHYST=68;