Вы находитесь на странице: 1из 1

LOAD CALCULATIONS

Job No. : Rev. No. : R0


Project : Date : 21/11/2019
Clint : Designed by :
Description : LOADS APPLIED ON THE MAIN FRAME-1 Checked by :
Building Type =
Length (o/o) = 30.00 m
Width (o/o) = 8.00 m
Width module =
Bay spacing = 4.00 m
Clear eave height = 4.00 m
Max. eave height = 6.00 m
Roof slope (θ) = 11.00 ˚
DEAD LOAD (DL)
Wt. of sheet & purline = 20.00 Kg/m²
Dead Load (DL) = 0.30 KN/m
Live load/unit area, roof = 75.00 Kg/m²
Live Load (LL) = 1.13 KN/m

WIND LOAD (WL)


Basic wind speed (Vb) = 50 m/s
Design wind speed (Vz) = Vbxk1xk2xk3
where,
k1 = probability factor (risk coefficient)
= 1 Terrain Category Class
k2 = terrain, height and structure size factor 2 A
= 1
k3 = topography factor
= 1
Vz = 50 m/s

Design wind pressure (pz) = 0.6xVz²


pz = 1.500 KN/m²

PRESURE COEFFICIENTS:~
Encloser condition of the building = Enclosed
Internal pressure coeff.(Cpi) = 0.20

h/w = 0.75
= 1/2<h/w<=3/2
l/w = 3.75
= 3/2<=l/w<4
External pressure coeff.(Cpe) : Table 4 Table 5
Wind Angle Coeff. For Wall Coeff. For Roof
(ө)
Left Right Left Right
0 degree 0.70 -0.25 -0.9350 -0.40
90 degree -0.50 -0.50 -0.80 -0.80

WIND LOAD DIAGRAMS:~

Wind Across the Ridge (With -Ve Cpi) Wind Across the Ridge (With +Ve Cpi)
KN/m
-0.74 -4.41 KN/m -0.20 -1.20KN/m -1.14 -6.810 KN/m -0.60 -3.60

KN/m KN/m KN/m KN/m


5.40 -0.30 3.00 -2.70
0.90 -0.05 0.50 -0.45

Wind Parallel to Ridge(With +Ve Cpi)


-1.00 -6.00 KN/m -1.00 -6.00 KN/m

KN/m KN/m
-4.20 -4.20
-0.70 -0.70

Wind Parallel to Ridge(With -Ve Cpi)


-0.60 -3.60 KN/m -0.60 -3.60 KN/m

KN/m KN/m
-1.80 #REF!
-0.30 -0.30
Note:
1) Values within the circles are the UDL
2) -Ve value means, load applied
away from structure.