Академический Документы
Профессиональный Документы
Культура Документы
ABSTRACT OF COST
(b) Providing & fixing of door / windows grill. (PWD 502) 11654.213 KG 57.00 664290.11
Dark shade pigment using ordinary cement (DSR-11.19.1) 104.788 SQM 902.020 94520.87
46 Providing and fixing ISI marked flush door shutters
conforming to IS : 2202 (Part I) decorative type,
core of block board construction with frame of 1st
class hard wood and well matched teak 3 ply
veneering with vertical grains or cross bands and
face veneers on both faces of shutters. (a)25 mm
thick (for cupboard) including ISI marked nickel
plated bright finished M.S. Piano hinges IS : 3818
marked with necessary screws.DEDUCT VAT 4%
=2129.10-85.16
(DSR-9.20.3) 243.760 SQM 2043.940 498230.81
TOTAL 35615333.83
ADD 2% CONTINGIENCES 712306.68
COST OF ENGINEERING APPRECIATION 956193.11
G.TOTAL 37283833.61
DETAILS OF MEASUREMENT
2c Bitumen Painting
(SAME AS ITEM NO. 2b) TOTAL 2974.00 SQM
b First Floor
ROOM 26 6.030 0.230 3.350 120.799
15 4.880 0.230 3.350 56.401
ROOM WARDROBE 26 0.600 0.230 3.350 12.020
DINING 2 8.430 0.230 3.350 12.991
2 12.490 0.230 3.350 19.247
COMMON AREA 1 4.230 0.230 3.350 3.259
1 4.880 0.230 3.350 3.760
CORRIDOR 2 2.730 0.230 3.350 4.207
1 4.230 0.230 3.350 3.259
1 10.540 0.230 3.350 8.121
2 3.330 0.230 3.350 5.132
STAIR CASE 2 5.330 0.230 3.350 8.214
1 4.660 0.230 3.350 3.591
SPACE FOR BRUSHING 1 2.400 0.230 3.350 1.849
1 4.880 0.230 3.350 3.760
TOILET 2 8.430 0.230 3.350 12.991
1 4.880 0.230 3.350 3.760
RAMP 2 25.230 0.230 3.350 38.879
1 23.000 0.230 3.350 17.722
1 4.660 0.230 3.350 3.591
1 2.330 0.230 3.350 1.795
OFFSET 19 0.600 0.230 3.350 8.784
TOTAL 354.130 CUM
DEDUCTION (-)
D 1 1.80 0.230 2.55 1.056
D2 14 1.20 0.230 2.55 9.853
W 1 2.50 0.230 1.65 0.949
W1 3 2.00 0.230 1.65 2.277
W2 18 1.80 0.230 1.50 11.178
W3 1 1.50 0.230 1.65 0.569
W4 28 1.29 0.230 1.65 13.708
V 2 0.90 0.230 0.45 0.186
V2 5 0.60 0.230 0.60 0.414
TOTAL 40.190 CUM
c Second Floor
ROOM 14 6.030 0.230 3.350 65.046
9 4.880 0.230 3.350 33.840
ROOM WARDROBE 14 0.600 0.230 3.350 6.472
COMMON AREA 1 4.230 0.230 3.350 3.259
2 4.880 0.230 3.350 7.520
CORRIDOR 2 2.730 0.230 3.350 4.207
1 4.230 0.230 3.350 3.259
1 10.540 0.230 3.350 8.121
1 3.330 0.230 3.350 2.566
1 8.440 0.230 3.350 6.503
STAIR CASE 2 5.330 0.230 3.350 8.214
1 4.660 0.230 3.350 3.591
SPACE FOR BRUSHING 1 2.400 0.230 3.350 1.849
1 4.880 0.230 3.350 3.760
TOILET 2 8.430 0.230 3.350 12.991
1 4.880 0.230 3.350 3.760
RAMP 2 25.230 0.230 3.350 38.879
1 23.000 0.230 3.350 17.722
1 4.660 0.230 3.350 3.591
1 2.330 0.230 3.350 1.795
OFFSET 12 0.600 0.230 3.350 5.548
MUMTY 2 6.330 0.230 3.350 9.755
2 4.660 0.230 3.350 7.181
TOTAL 259.427 CUM
DEDUCTION (-)
D2 8 1.20 0.230 2.55 5.630
D3 2 1.05 0.230 2.55 1.232
W 1 2.50 0.230 1.65 0.949
W1 1 2.00 0.230 1.65 0.759
W2 5 1.80 0.230 1.50 3.105
W3 1 1.50 0.230 1.65 0.569
W4 16 1.29 0.230 1.65 7.833
V 2 0.90 0.230 0.45 0.186
V2 5 0.60 0.230 0.60 0.414
TOTAL 20.677 CUM
14 M. S. work in R.C.C.
qty same as item no (6)*0.9*0.785 (Lintel) 8.536
qty same as item no (7)*1.00*0.785 (Slab) 283.591
qty same as item no (8)*2.00*0.785 (Beam) 258.077
qty same as item no (9)*1.00*0.785 (Footing 88.043
qty same as item no (10)*3*0.785 (Column) 235.509
TOTAL 873.755 QTL
15 12mm cement plaster (Interior surface)
G.F
ROOM 5 20.900 3.350 350.08
ROOM WARDROBE 5 6.740 3.350 112.90
WARDEN ROOM 1 20.900 3.350 70.02
WARDEN ROOM WARDROBE 1 6.740 3.350 22.58
VISITOR ROOM 1 17.680 3.350 59.23
VISITOR ROOM WARDROBE 1 6.540 3.350 21.91
COMPOUNDER ROOM 1 20.900 3.350 70.02
COMPOUNDER ROOM WARDROBE 1 6.540 3.350 21.91
SICK ROOM 1 20.900 3.350 70.02
SICK ROOM WARDROBE 1 6.740 3.350 22.58
CYBER ROOM 1 20.900 3.350 70.02
CYBER ROOM WARDROBE 1 6.740 3.350 22.58
MESS WORKER ROOM 1 12.110 3.350 40.57
KITCHEN 1 25.300 3.350 84.76
PASSAGE 1 9.660 3.350 32.36
WASH 1 11.980 3.350 40.13
PANTRY 1 11.980 3.350 40.13
DINING 1 40.920 3.350 137.08
ENT. LOBBY 1 17.760 3.350 59.50
ENTRANCE VER 1 13.120 3.350 43.95
CORRIDOR 1 102.760 3.350 344.25
1 35.140 3.350 117.72
STAIR CASE 1 19.060 3.350 63.85
SPACE FOR BRUSHING 1 11.480 3.350 38.46
1 5.540 3.350 18.56
TOILET 4 7.540 3.350 101.04
TOILET 1 25.700 3.350 86.10
BATH 4 5.900 3.350 79.06
WC 5 4.500 3.350 75.38
BATH 1 5.100 3.350 17.09
WC 1 4.500 3.350 15.08
STORE 1 11.700 3.350 39.20
RAMP 1 58.860 3.350 197.18
F.F
ROOM 13 20.900 3.350 910.20
ROOM WARDROBE 13 6.740 3.350 293.53
DINING 1 40.920 3.350 137.08
COMMON AREA 1 17.760 3.350 59.50
CORRIDOR 1 102.760 3.350 344.25
1 35.140 3.350 117.72
STAIR CASE 1 15.460 3.350 51.79
SPACE FOR BRUSHING 1 11.480 3.350 38.46
1 5.540 3.350 18.56
TOILET 1 25.700 3.350 86.10
BATH 4 5.900 3.350 79.06
WC 5 4.500 3.350 75.38
RAMP 1 58.860 3.350 197.18
S.F
ROOM 7 20.900 3.350 490.11
ROOM WARDROBE 7 6.740 3.350 158.05
COMMON AREA 1 17.760 3.350 59.50
CORRIDOR 1 58.580 3.350 196.24
1 35.140 3.350 117.72
STAIR CASE 1 15.460 3.350 51.79
SPACE FOR BRUSHING 1 11.480 3.350 38.46
1 5.540 3.350 18.56
TOILET 1 25.700 3.350 86.10
BATH 4 5.900 3.350 79.06
WC 5 4.500 3.350 75.38
RAMP 1 58.860 3.350 197.18
MUMTY 1 21.060 2.400 50.54
TOTAL 6612.692 SQM
DEDUCTION (-)
G.F
D 1 1.80 2.55 4.59
D1 1 1.50 2.55 3.83
D2 12 1.20 2.55 36.72
D3 3 1.05 2.55 8.03
D4 2 0.90 2.10 3.78
D5 15 0.75 2.10 23.63
W1 3 2.00 1.65 9.90
W2 18 1.80 1.50 48.60
W3 2 1.50 1.65 4.95
W4 18 1.29 1.65 38.31
W5 2 1.00 1.65 3.30
V 2 0.90 0.45 0.81
V1 4 0.75 0.75 2.25
V2 5 0.60 0.60 1.80
CH 1 2.50 2.55 6.38
F.F
D 1 1.80 2.55 4.59
D2 14 1.20 2.55 42.84
D5 9 0.75 2.10 14.18
W 1 2.50 1.65 4.13
W1 3 2.00 1.65 9.90
W2 18 1.80 1.50 48.60
W3 1 1.50 1.65 2.48
W4 28 1.29 1.65 59.60
V 2 0.90 0.45 0.81
V2 5 0.60 0.60 1.80
S.F
D2 8 1.20 2.55 24.48
D3 2 1.05 2.55 5.36
D5 9 0.75 2.10 14.18
W 1 2.50 1.65 4.13
W1 1 2.00 1.65 3.30
W2 5 1.80 1.50 13.50
W3 1 1.50 1.65 2.48
W4 16 1.29 1.65 34.06
V 2 0.90 0.45 0.81
V2 5 0.60 0.60 1.80
TOTAL 489.860 SQM
(B) INTERNAL
ROOM 5 20.900 0.150 15.675
ROOM WARDROBE 5 6.740 0.150 5.055
WARDEN ROOM 1 20.900 0.150 3.135
WARDEN ROOM WARDROBE 1 6.740 0.150 1.011
VISITOR ROOM 1 17.680 0.150 2.652
VISITOR ROOM WARDROBE 1 6.540 0.150 0.981
COMPOUNDER ROOM 1 20.900 0.150 3.135
COMPOUNDER ROOM WARDROBE 1 6.540 0.150 0.981
SICK ROOM 1 20.900 0.150 3.135
SICK ROOM WARDROBE 1 6.740 0.150 1.011
CYBER ROOM 1 20.900 0.150 3.135
CYBER ROOM WARDROBE 1 6.740 0.150 1.011
MESS WORKER ROOM 1 12.110 0.150 1.817
KITCHEN 1 25.300 0.150 3.795
PASSAGE 1 9.660 0.150 1.449
WASH 1 11.980 0.150 1.797
PANTRY 1 11.980 0.150 1.797
DINING 1 40.920 0.150 6.138
ENT. LOBBY 1 17.760 0.150 2.664
ENTRANCE VER 1 13.120 0.150 1.968
CORRIDOR 1 102.760 0.150 15.414
1 35.140 0.150 5.271
STAIR CASE 1 19.060 0.150 2.859
SPACE FOR BRUSHING 1 11.480 0.150 1.722
1 5.540 0.150 0.831
TOILET 4 7.540 0.150 4.524
TOILET 1 25.700 0.150 3.855
BATH 4 5.900 0.150 3.540
WC 5 4.500 0.150 3.375
BATH 1 5.100 0.150 0.765
WC 1 4.500 0.150 0.675
STORE 1 11.700 0.150 1.755
RAMP 1 58.860 0.150 8.829
TOTAL 152.750 SQM
18 Making grooves.
G.F
5 20.900 3.350 350.075
5 6.740 3.350 112.895
1 20.900 3.350 70.015
1 6.740 3.350 22.579
1 17.680 3.350 59.228
1 6.540 3.350 21.909
1 20.900 3.350 70.015
1 6.540 3.350 21.909
1 20.900 3.350 70.015
1 6.740 3.350 22.579
1 20.900 3.350 70.015
1 6.740 3.350 22.579
1 12.110 3.350 40.569
1 25.300 3.350 84.755
1 9.660 3.350 32.361
1 11.980 3.350 40.133
1 11.980 3.350 40.133
1 40.920 3.350 137.082
1 17.760 3.350 59.496
1 13.120 3.350 43.952
1 102.760 3.350 344.246
1 35.140 3.350 117.719
1 19.060 3.350 63.851
1 11.480 3.350 38.458
1 5.540 3.350 18.559
4 7.540 3.350 101.036
1 25.700 3.350 86.095
4 5.900 3.350 79.060
5 4.500 3.350 75.375
1 5.100 3.350 17.085
1 4.500 3.350 15.075
1 11.700 3.350 39.195
1 58.860 3.350 197.181
F.F 0.000
13 20.900 3.350 910.195
13 6.740 3.350 293.527
1 40.920 3.350 137.082
1 17.760 3.350 59.496
1 102.760 3.350 344.246
1 35.140 3.350 117.719
1 15.460 3.350 51.791
1 11.480 3.350 38.458
1 5.540 3.350 18.559
1 25.700 3.350 86.095
4 5.900 3.350 79.060
5 4.500 3.350 75.375
1 58.860 3.350 197.181
S.F 0.000
7 20.900 3.350 490.105
7 6.740 3.350 158.053
1 17.760 3.350 59.496
1 58.580 3.350 196.243
1 35.140 3.350 117.719
1 15.460 3.350 51.791
1 11.480 3.350 38.458
1 5.540 3.350 18.559
1 25.700 3.350 86.095
4 5.900 3.350 79.060
5 4.500 3.350 75.375
1 58.860 3.350 197.181
1 21.060 3.350 70.551
TOTAL 6632.70 SQM
19 40 mm thick C. C. Flooring
STORE 1 2.630 3.220 8.47
TOTAL 8.469 SQM
20 C. C. Skirting.
STORE 1 11.70 0.150 1.76
TOTAL 1.755 SQM
21 25 mm thick C.C. Flooring
OUTER APRON 2 59.570 0.900 107.226
2 24.710 0.900 44.478
TOTAL 151.704 SQM
22 Vertified tiles flooring size (600x600)
G.F
ROOM 5 5.80 4.65 134.85
ROOM WARDROBE 5 2.77 0.60 8.31
WARDEN ROOM 1 5.80 4.65 26.97
WARDEN ROOM WARDROBE 1 2.77 0.60 1.66
VISITOR ROOM 1 4.19 4.65 19.48
VISITOR ROOM WARDROBE 1 2.67 0.60 1.60
COMPOUNDER ROOM 1 5.80 4.65 26.97
COMPOUNDER ROOM WARDROBE 1 2.67 0.60 1.60
SICK ROOM 1 5.80 4.65 26.97
SICK ROOM WARDROBE 1 2.77 0.60 1.66
CYBER ROOM 1 5.80 4.65 26.97
CYBER ROOM WARDROBE 1 2.77 0.60 1.66
F.F
ROOM 13 5.80 4.65 350.61
ROOM WARDROBE 13 2.77 0.60 21.61
S.F
ROOM 7 5.80 4.65 188.79
ROOM WARDROBE 7 2.77 0.60 11.63
TOTAL 851.354 SQM
24 Kota Flooring.
G.F
MESS WORKER ROOM 1 3.06 3.00 9.17
KITCHEN 1 8.00 4.65 37.20
PASSAGE 1 3.29 1.54 5.07
PANTRY 1 3.72 2.27 8.44
DINING 1 8.20 12.26 100.53
CORRIDOR 1 48.88 2.50 122.20
1 12.87 4.70 60.49
STAIR CASE 1 5.10 4.43 22.59
SPACE FOR BRUSHING 1 2.17 3.57 7.75
1 1.57 1.20 1.88
RAMP 1 25.00 4.43 110.75
F.F
DINING 1 8.20 12.26 100.53
COMMON AREA 1 4.00 4.88 19.52
CORRIDOR 1 48.88 2.50 122.20
1 12.87 4.70 60.49
STAIR CASE 1 3.30 4.43 14.62
SPACE FOR BRUSHING 1 2.17 3.57 7.75
S.F
COMMON AREA 1 4.00 4.88 19.52
CORRIDOR 1 26.79 2.50 66.98
1 12.87 4.70 60.49
STAIR CASE 1 3.30 4.43 14.62
SPACE FOR BRUSHING 1 2.17 3.57 7.75
1 1.57 1.20 1.88
TOTAL 982.412 SQM
25 Kota Skirting.
G.F
MESS WORKER ROOM 1 12.11 0.150 1.82
KITCHEN 1 25.30 0.150 3.80
PASSAGE 1 9.66 0.150 1.45
PANTRY 1 11.98 0.150 1.80
DINING 1 40.92 0.150 6.14
ENT. LOBBY 1 17.76 0.150 2.66
ENTRANCE VER 1 13.12 0.150 1.97
CORRIDOR 1 102.76 0.150 15.41
1 35.14 0.150 5.27
STAIR CASE 1 19.06 0.150 2.86
SPACE FOR BRUSHING 1 11.48 0.150 1.72
1 5.54 0.150 0.83
RAMP 1 58.86 0.150 8.83
STAIR LANDING 1 4.89 2.030 9.93
STEPS 22 1.80 0.300 11.88
23 1.80 0.150 6.21
STEPS 5 2.96 0.300 4.44
6 2.96 0.150 2.66
STEPS 5 4.03 0.300 6.05
6 4.03 0.150 3.63
STEPS 5 1.43 0.300 2.15
6 1.43 0.150 1.29
F.F
DINING 1 40.92 0.150 6.14
COMMON AREA 1 17.76 0.150 2.66
CORRIDOR 1 102.76 0.150 15.41
1 35.14 0.150 5.27
STAIR CASE 1 15.46 0.150 2.32
SPACE FOR BRUSHING 1 11.48 0.150 1.72
STAIR LANDING 1 4.89 2.030 9.93
STEPS 22 1.80 0.300 11.88
23 1.80 0.150 6.21
S.F
COMMON AREA 1 17.76 0.150 2.66
CORRIDOR 1 58.58 0.150 8.79
1 35.14 0.150 5.27
STAIR CASE 1 15.46 0.150 2.32
SPACE FOR BRUSHING 1 11.48 0.150 1.72
1 5.54 0.150 0.83
STAIR LANDING 1 4.89 2.030 9.93
STEPS 22 1.80 0.300 11.88
23 1.80 0.150 6.21
TOTAL 213.93 SQM
26 Grainite Flooring
ENT. LOBBY 1 4.00 4.88 19.52
ENTRANCE VER 1 4.46 2.10 9.37
Skirting
ENT. LOBBY 1 17.760 0.150 2.66
ENTRANCE VER 1 13.120 0.150 1.97
ENTRANCE STEPS 5 4.460 0.300 6.69
6 4.460 0.150 4.01
TOTAL 44.22 SQM
(b) M.S.Grill
G.F
D 1 1.80 0.450 25.00 20.250
D1 1 1.50 0.450 25.00 16.875
D2 12 1.20 0.450 25.00 162.000
D3 3 1.05 0.450 25.00 35.438
W1 3 2.00 1.650 25.00 247.500
W2 18 1.80 1.500 25.00 1215.000
W3 2 1.50 1.650 25.00 123.750
W4 18 1.29 1.650 25.00 957.825
W5 2 1.00 1.650 25.00 82.500
V 2 0.90 0.450 25.00 20.250
V1 4 0.75 0.750 25.00 56.250
V2 5 0.60 0.600 25.00 45.000
STAIR RAILING 2 4.17 0.900 25.00 187.650
RAMP RAILING 2 22.84 0.900 25.00 1027.800
F.F
D 1 1.80 0.45 25.00 20.250
D2 14 1.20 0.45 25.00 189.000
W 1 2.50 1.65 25.00 103.125
W1 3 2.00 1.65 25.00 247.500
W2 18 1.80 1.50 25.00 1215.000
W3 1 1.50 1.65 25.00 61.875
W4 28 1.29 1.65 25.00 1489.950
V 2 0.90 0.45 25.00 20.250
V2 5 0.60 0.60 25.00 45.000
STAIR RAILING 2 4.17 0.900 25.00 187.650
RAMP RAILING 2 22.84 0.900 25.00 1027.800
S.F
D2 8 1.20 0.45 25.00 108.000
D3 2 1.05 0.45 25.00 23.625
W 1 2.50 1.65 25.00 103.125
W1 1 2.00 1.65 25.00 82.500
W2 5 1.80 1.50 25.00 337.500
W3 1 1.50 1.65 25.00 61.875
W4 16 1.29 1.65 25.00 851.400
V 2 0.90 0.45 25.00 20.250
V2 5 0.60 0.60 25.00 45.000
STAIR RAILING 2 4.17 0.900 25.00 187.650
RAMP RAILING 2 22.84 0.900 25.00 1027.800
TOTAL 11654.21 KG.
(c) Z-Section Windows
G.F
D 1 1.80 0.450 30.000 24.300
D1 1 1.50 0.450 30.000 20.250
D2 12 1.20 0.450 30.000 194.400
D3 3 1.05 0.450 30.000 42.525
W1 3 2.00 1.650 30.000 297.000
W2 18 1.80 1.500 30.000 1458.000
W3 2 1.50 1.650 30.000 148.500
W4 18 1.29 1.650 30.000 1149.390
W5 2 1.00 1.650 30.000 99.000
V 2 0.90 0.450 30.000 24.300
V1 4 0.75 0.750 30.000 67.500
V2 5 0.60 0.600 30.000 54.000
F.F
D 1 1.80 0.45 30.000 24.300
D2 14 1.20 0.45 30.000 226.800
W 1 2.50 1.65 30.000 123.750
W1 3 2.00 1.65 30.000 297.000
W2 18 1.80 1.50 30.000 1458.000
W3 1 1.50 1.65 30.000 74.250
W4 28 1.29 1.65 30.000 1787.940
V 2 0.90 0.45 30.000 24.300
V2 5 0.60 0.60 30.000 54.000
S.F
D2 8 1.20 0.45 30.000 129.600
D3 2 1.05 0.45 30.000 28.350
W 1 2.50 1.65 30.000 123.750
W1 1 2.00 1.65 30.000 99.000
W2 5 1.80 1.50 30.000 405.000
W3 1 1.50 1.65 30.000 74.250
W4 16 1.29 1.65 30.000 1021.680
V 2 0.90 0.45 30.000 24.300
V2 5 0.60 0.60 30.000 54.000
TOTAL 9609.435 KG.
(d) Mosquito proof jali on Windows / Ventilators
G.F
D 1 1.80 0.450 0.810
D1 1 1.50 0.450 0.675
D2 12 1.20 0.450 6.480
D3 3 1.05 0.450 1.418
W1 3 2.00 1.650 9.900
W2 18 1.80 1.500 48.600
W3 2 1.50 1.650 4.950
W4 18 1.29 1.650 38.313
W5 2 1.00 1.650 3.300
V 2 0.90 0.450 0.810
V1 4 0.75 0.750 2.250
V2 5 0.60 0.600 1.800
F.F
D 1 1.80 0.45 0.810
D2 14 1.20 0.45 7.560
W 1 2.50 1.65 4.125
W1 3 2.00 1.65 9.900
W2 18 1.80 1.50 48.600
W3 1 1.50 1.65 2.475
W4 28 1.29 1.65 59.598
V 2 0.90 0.45 0.810
V2 5 0.60 0.60 1.800
S.F
D2 8 1.20 0.45 4.320
D3 2 1.05 0.45 0.945
W 1 2.50 1.65 4.125
W1 1 2.00 1.65 3.300
W2 5 1.80 1.50 13.500
W3 1 1.50 1.65 2.475
W4 16 1.29 1.65 34.056
V 2 0.90 0.45 0.810
V2 5 0.60 0.60 1.800
TOTAL 320.315 SQM.
31 Angle iron chaukhats (40x40x5mm)
G.F
D 1 6.00 3.000 18.000
D1 1 5.70 3.000 17.100
D2 12 5.40 3.000 194.400
D3 3 5.25 3.000 47.250
D4 2 5.10 3.000 30.600
D5 15 4.95 3.000 222.750
F.F
D 1 6.00 3.000 18.000
D2 14 5.40 3.000 226.800
D5 9 4.95 3.000 133.650
S.F
D2 8 5.40 3.000 129.600
D3 2 5.25 3.000 31.500
D5 9 4.95 3.000 133.650
TOTAL 1203.300 KG.
32 Fixing D/W/V Chaukhats.
Door chaukhats 77.000 NOS
Window chaukhats 118.000 NOS
Ventilator chaukhats 25.000 NOS
34 Acrylic Painting
QTY. SAME AS OUTER PLASTER TOTAL 3431.904 SQM
36 Sliding bolt.
300 x 16mm TOTAL 77.000 NOS
37 Tower bolt
300 x 10mm TOTAL 77.000 NOS
38 Handle (125mm)
(a) 125mm TOTAL 154.000 NOS
41 Painting on wood.
G.F
D 1 1.80 2.10 2.000 7.560
D1 1 1.50 2.10 2.000 6.300
D2 12 1.20 2.10 2.000 60.480
D3 3 1.05 2.10 2.000 13.230
D4 2 0.90 2.10 2.000 7.560
D5 15 0.75 2.10 2.000 47.250
F.F
D 1 1.80 2.10 2.000 7.560
D2 14 1.20 2.10 2.000 70.560
D5 9 0.75 2.10 2.000 28.350
S.F
D2 8 1.20 2.10 2.000 40.320
D3 2 1.05 2.10 2.000 8.820
D5 9 0.75 2.10 2.000 28.350
TOTAL 326.340 SQM
42 Glass panes
G.F
D 1 1.80 0.450 0.810
D1 1 1.50 0.450 0.675
D2 12 1.20 0.450 6.480
D3 3 1.05 0.450 1.418
W1 3 2.00 1.650 9.900
W2 18 1.80 1.500 48.600
W3 2 1.50 1.650 4.950
W4 18 1.29 1.650 38.313
W5 2 1.00 1.650 3.300
V 2 0.90 0.450 0.810
V1 4 0.75 0.750 2.250
V2 5 0.60 0.600 1.800
F.F
D 1 1.80 0.45 0.810
D2 14 1.20 0.45 7.560
W 1 2.50 1.65 4.125
W1 3 2.00 1.65 9.900
W2 18 1.80 1.50 48.600
W3 1 1.50 1.65 2.475
W4 28 1.29 1.65 59.598
V 2 0.90 0.45 0.810
V2 5 0.60 0.60 1.800
S.F
D2 8 1.20 0.45 4.320
D3 2 1.05 0.45 0.945
W 1 2.50 1.65 4.125
W1 1 2.00 1.65 3.300
W2 5 1.80 1.50 13.500
W3 1 1.50 1.65 2.475
W4 16 1.29 1.65 34.056
V 2 0.90 0.45 0.810
V2 5 0.60 0.60 1.800
TOTAL 320.315 SQM
43 Making of Apron Drain
OUTER APRON 1 37.560 37.560
1 76.970 76.970
1 81.460 81.460
1 53.630 53.630
TOTAL 249.620 RM
44 Collapsible shutter
CH 1 2.50 2.55 6.375
TOTAL 6.375 SQM.
45 Chequered terrazo tiles on Ramp
RAMP LANDING 1 2.000 4.430 8.860
RAMP FLIGHT 2 22.84 2.100 95.928
TOTAL 104.788 SQM.
46 Cup board Shutter.
G.F.
10 2.770 2.200 60.940
10 2.770 2.200 60.940
F.F.
13 2.770 2.200 79.222
S.F.
7 2.770 2.200 42.658
TOTAL 243.760 SQM
47 Cinder filling
G.F
WASH 1 3.72 2.27 0.450 3.80
TOILET 4 1.50 2.27 0.450 6.13
TOILET 1 8.20 4.65 0.450 17.16
BATH 4 1.45 1.50 0.450 3.92
WC 5 1.05 1.20 0.450 2.84
BATH 1 1.35 1.20 0.450 0.73
WC 1 1.05 1.20 0.450 0.57
F.F
TOILET 1 8.20 4.65 0.450 17.16
BATH 4 1.45 1.50 0.450 3.92
WC 5 1.05 1.20 0.450 2.84
S.F
TOILET 1 8.20 4.65 0.450 17.16
BATH 4 1.45 1.50 0.450 3.92
WC 5 1.05 1.20 0.450 2.84
TOTAL 82.95 CUM
48 Water proofing treatment in sunken portion
G.F
WASH 1 11.98 0.450 5.39
TOILET 4 7.54 0.450 13.57
TOILET 1 25.70 0.450 11.57
BATH 4 5.90 0.450 10.62
WC 5 4.50 0.450 10.13
BATH 1 5.10 0.450 2.30
WC 1 4.50 0.450 2.03
F.F
TOILET 1 25.70 0.450 11.57
BATH 4 5.90 0.450 10.62
WC 5 4.50 0.450 10.13
S.F
TOILET 1 25.70 0.450 11.57
BATH 4 5.90 0.450 10.62
WC 5 4.50 0.450 10.13
TOTAL 120.213 SQM
49 S/Fixing of Glass Strip
Qty same as C.C. flooring x 6 910.224
TOTAL 910.224 RM
Flat back Wash Basin size 550X400 mm with single 15mm C. P. brass pillar tap 17.7.4 11 Nos 1817.35 19,990.85
4 Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including
PVC waste fittings complete. -
32 mm dia (for wash basin) 17.28.2.1 11 Nos 68.89 757.79
40 mm dia (for sink and urinal) 17.28.2.2 6 Nos 73.57 441.42
5 Providing & Fixing 600 X 450 mm bevelled edge mirror of superior glass (of
approved quality) complete with 6mm thick hard board ground fixed to wooden
cleats with C.P. brass screws and washers complete. 17.31 11 Nos 735.51 8,090.61
6 Providing & fixing viterous china toilet paper holder. 17.34.2 4 Nos 295.45 1,181.80
7 Providing & fixing stainless steel AISI 304 (18/8) kitchen sink with drain board
as per IS :13983 with C.I. brackets and stainless steel plug 40 mm including
painting of fittings and brackets cutting and making good the walls wherever
required.
510 x 1040 bowl depth 250 mm 17.10.1.1 2 Nos 4120.80 8,241.60
8 Providing & fixing salem stainless steel AISI 304(18/8) kitchen sink without
drain board as per IS : 13983 with C. I. brackets and stainless steel plug 40
mm including painting of fitting and brackets cutting and making good the walls
wherever required.
610 x 510 bowl depth 200 mm 17.10.2.1 2 Nos 2,476.60 4,953.20
9 Providing & fixing pipes.
100mm dia sand cast iron S & S Pipe 17.35.1.1 250 Rm 862.80 215,700.00
75mm dia sand cast iron S & S pipe 17.35.2.1 140 Rm 712.20 99,708.00
10 Providing lead Caulked joints to sand cast iron/centrifugally cast (spun) iron pipes
& fittings of diameters.
100 mm 17.58.1 200 Nos 309.95 61,990.00
75 mm 17.58.2 110 Nos 263.60 28,996.00
11 Providing & fixing M. S. holder - bat clamps of approved design to sand Cast
iron/cast iron (spun) pipe embedded in & including cement concrete blocks
10*10*10cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20
mm nominal size). Including cost of cutting holes&making good the walls etc.
up to 1.50 m depth
Pipes 80 mm to 300 mm diameter 2.10.1.2 80 Rm 225.45 18,036.00
35 Providing, laying and jointing glazed stone ware pipes grade `A' with stiff
mixture of cement mortar in the proportion of 1:1 (1cement :1 fine sand)
including testing of joints etc complete.
150 mm diameter 19.1.2 80 Rm 294.30 23,544.00
36 Providing and laying cement concrete 1 : 5 : 10 (1 cement : 5 coarse sand : 10
gradded stone aggregate 40 mm nominal size) alround S.W. Pipes including bed
concrete as per standard design.
150 mm diameter S.W.Pipe 19.2.2 80 Rm 600.02 48,001.60
37 Constructing brick masonry manhole with F.P.S. bricks in cement mortar 1 : 4 (1
cement : 4 coarse sand) RCC top slab with 1 : 2 : 4 mix (1 cement : 2 coarse sand : 4
grade stone aggregate 20mm nominal size); foundation concrete 1:4:8 mix (1
cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) inside
plastering 12 mm thick with cement mortar 1:3 (1cement 3 coarse sand ) finished
with a floating coat of neat cement and making channels in cement concrete 1:2:4
(1cement : 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) finishd
with a floating coat of neat cement complete as per standard design
Inside size 90 x 80 cm & 45 cm deep including CI cover with frame (light duty)
455 x 610mm internal dimension total wt. of cover & frame to be not less than 38
kg (wt. of cover 23 kg and wt. of frame 15 kg) 19.7.1.1 8 Nos 7475.80 59,806.40
38 Extra for depth for manhole with F.P.S. bricks
size 90 X 80 cm 19.8.1.1 1 Rm 5282.92 5,282.92
39 Providing and fixing square mouth S. W. Gully trap grade `A' complete with C.I.
grating brick masonry chamber with F.P.S bricks and water tight CI cover with
frame of 300 x 300 mm size (inside) the weight of cover to be not less than 4.50 kg
and frame to be not less than 2.70 kg as per standard design
180 x 150 mm. size P type 19.4.3.1 9 Nos 1,706.55 15,358.95
40 Making soak-pit 2.5 m. diameter and 3 m. deep with 45 x 45cm dry brick honey
comb shaft with F.P.S bricks and SW drain pipe complete as per standard
design. 19.32.1 4 Nos 20,681.55 82,726.20
TOTAL ( SCHEDULED ITEM AS PER DSR - 2016 ) 1,224,994.13
435,069.64
TOTAL ( NON-SCHEDULED ITEM ) 1,115,769.64
22.47
DETAILED MEASURMENT OF PLUMBING WORKS
DETAILED ESTIMATE OF PROPOSED 100 SEATED HOSTEL FOR PRAYAS GOVT. BOYS HIGH
SCHOOL FOR DIFFERENTLY ABLED, AT - DISTT:-PRATAPGARH (U.P.)
PART A (SCHEDULED ITEMS AS PER D.S.R. - 2016)
SNo DESCRIPTION QTY UNIT
1 Providing and fixing white vitreous china pedestal type water closet (European
type W.C. pan) with ISI marked white solid plastic seat and lid, 10 litre low level
white P.V.C. flushing cistern with manually controlled device (handle lever),
conforming to IS : 7231, with all fittings and fixtures complete including cutting and
making good the walls and floors wherever required. 4 Nos
2 Providing and fixing water closet squatting pan (Indian type W.C. pan) with
100mm sand cast iron P or S trap, 10 litre low level white P.V.C. flushing cistern
with manually controlled device (handle lever) conforming to IS : 7231, with all
fitting and fixtures completed including cutting and making good the walls and
floors wherever required.
White Vitreous china Orissa pattern W.C. pan of size 580x440mm with integral
type foot rests 16 Nos
3 Providing & fixing white viterous china wash basin with C.I. brackets, 15 mm C.P.
brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of
fitting and brackets, cutting & making good the walls wherever required .
Flat back Wash Basin size 550X400 mm with single 15mm C. P. brass pillar tap 11 Nos
4 Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including
PVC waste fittings complete.
32 mm dia (for wash basin) 11 Nos
40 mm dia (for sink and urinal) 6 Nos
5 Providing & Fixing 600 X 450 mm bevelled edge mirror of superior glass (of
approved quality) complete with 6mm thick hard board ground fixed to wooden
cleats with C.P. brass screws and washers complete. 11 Nos
6 Providing & fixing viterous china toilet paper holder. 4 Nos
7 Providing & fixing stainless steel AISI 304 (18/8) kitchen sink with drain board
as per IS :13983 with C.I. brackets and stainless steel plug 40 mm including
painting of fittings and brackets cutting and making good the walls wherever
required.
510 x 1040 bowl depth 250 mm 2 Nos
8 Providing & fixing salem stainless steel AISI 304(18/8) kitchen sink without
drain board as per IS : 13983 with C. I. brackets and stainless steel plug 40
mm including painting of fitting and brackets cutting and making good the walls
wherever required.
610 x 510 bowl depth 200 mm 2 Nos
9 Providing & fixing pipes.
100mm dia sand cast iron S & S Pipe 250 Rm
75mm dia sand cast iron S & S pipe 140 Rm
10 Providing lead Caulked joints to sand cast iron/centrifugally cast (spun) iron pipes
& fittings of diameters.
100 mm 200 Nos
75 mm 110 Nos
11 Providing & fixing M. S. holder - bat clamps of approved design to sand Cast
iron/cast iron (spun) pipe embedded in & including cement concrete blocks
10*10*10cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20
mm nominal size). Including cost of cutting holes&making good the walls etc.
Concealed work including cutting chase and making good the wall etc.
15mm nominal outer dia pipes 175 Rm
20mm nominal outer dia pipes 150 Rm
25mm nominal outer dia pipes 90 Rm
32mm nominal outer dia pipes 45 Rm
22 Providing, fixing G. I. pipes complete with G. I. fittings and clamps including
cutting and making good the walls etc. (internal work) - (Exposed on wall)
15mm dia nominal bore 25 Rm
20mm dia nominal bore 95 Rm
25mm dia nominal bore 75 Rm
40mm dia nominal bore 45 Rm
23 Painting G. I. pipes and fittings with synthetic enamel white paint over a ready
mixed priming coat, both of approved quality for new work.
15mm dia nominal bore 25 Rm
20mm dia nominal bore 95 Rm
25mm dia nominal bore 75 Rm
40mm dia nominal bore 45 Rm
24 Providing & fixing gun metal gate valve with C.I. wheel of approved quality
(screwed end)
25 mm nominal bore 8 Nos
40 mm nominal bore 4 Nos
25 Providing and fixing ball valve (brass) of approved quality complete. (High or low
pressure with plastic floats).
20 mm nominal bore 3 Nos
25 mm nominal bore 2 Nos
26 Providing & fixing 15 mm nominal bore 45 cm long unplasticised PVC
connection pipe with brass unions. 26 Nos
27 Providing & fixing 15 mm nominal bore CP brass bib cock of approved quality
conforming to IS 8931. 13 Nos.
28 Providing and fixing 15 mm nominal bore C.P brass long nose bib cock of
approved quality conforming to IS standards and weighing not less than 810 gms.
17 Nos.
29 Providing & fixing 15 mm nominal bore C.P. brass stop cock (concealed) of
standard design and of approved make conforming to IS : 8931. 12 Nos.
30 Providing & fixing 15 mm nominal bore C.P brass angle valve for basin mixer and
geyser points of approved quality conforming to IS 8931. 31 Nos.
31 Providing & fixing 100 mm dia C.P brass shower rose with 15 mm inlet. 12 Nos.
32 Providing and placing on terrace (at all floor levels) polyethylene water storage
tank ISI : 12701 marked with cover and suitable locking arrangement and making
necessary holes for inlet, outlet and overflow pipes but without fitting and base
support for tank.
1500 litres capacity 1 Nos.
2500 litres capacity 2 Nos.
33 Constructing brick masonry chamber 300 x 300 x 500 mm, inside with F.P.S.
brick work in cement mortar 1: 4 (1 cement : 4 coarse sand) for Stop Cock, with
C. I. surface box 100 x 100 x 75 mm (inside) with hinged cover fixed in cement
concrete slab 1:2:4mix (1cement : 2 coarse sand:4 grade stone aggregate 20mm
nominal size); necessary excavation, foundation concrete 1:5:10 (1 cement :5 fine
sand: 10 graded stone aggregate 40mm nominal size) and inside plastering with
cement mortar 1 : 3 (1 cement : 3 coarse sand ) 12 mm thick finished with a
floating coat of neat cement complete as per standard design
3 Nos
34 Excavating trenches in all kind of soil of required width for pipes. including
excavation for sockets and dressing of sides, ramming of bottoms, including getting
out the excavated soil & then returning the soil as required, in layers not exceeding
20 cm in depth including consolidating each deposited layer by ramming, watering,
etc & disposing of surplus excavated soil as directed within a lead of 50m.
up to 1.50 m depth
Pipes 80 mm to 300 mm diameter 80 Rm
35 Providing, laying and jointing glazed stone ware pipes grade `A' with stiff
mixture of cement mortar in the proportion of 1:1 (1cement :1 fine sand)
including testing of joints etc complete.
150 mm diameter 80 Rm
36 Providing and laying cement concrete 1 : 5 : 10 (1 cement : 5 coarse sand : 10
gradded stone aggregate 40 mm nominal size) alround S.W. Pipes including bed
concrete as per standard design.
150 mm diameter S.W.Pipe 80 Rm
37 Constructing brick masonry manhole with F.P.S. bricks in cement mortar 1 : 4 (1
cement : 4 coarse sand) RCC top slab with 1 : 2 : 4 mix (1 cement : 2 coarse sand : 4
grade stone aggregate 20mm nominal size); foundation concrete 1:4:8 mix (1
cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) inside
plastering 12 mm thick with cement mortar 1:3 (1cement 3 coarse sand ) finished
with a floating coat of neat cement and making channels in cement concrete 1:2:4
(1cement : 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) finishd
with a floating coat of neat cement complete as per standard design
Inside size 90 x 80 cm & 45 cm deep including CI cover with frame (light duty)
455 x 610mm internal dimension total wt. of cover & frame to be not less than 38
kg (wt. of cover 23 kg and wt. of frame 15 kg) 8 Nos
38 Extra for depth for manhole with F.P.S. bricks
size 90 X 80 cm 1 Rm
39 Providing and fixing square mouth S. W. Gully trap grade `A' complete with C.I.
grating brick masonry chamber with F.P.S bricks and water tight CI cover with
frame of 300 x 300 mm size (inside) the weight of cover to be not less than 4.50 kg
and frame to be not less than 2.70 kg as per standard design
180 x 150 mm. size P type 9 Nos
40 Making soak-pit 2.5 m. diameter and 3 m. deep with 45 x 45cm dry brick honey
comb shaft with F.P.S bricks and SW drain pipe complete as per standard
design. 4 Nos
1.00 Job.
SCHEDULE OF QUANTITIES FOR ELECTRICAL INSTALLATIONS
DETAILED ESTIMATE OF PROPOSED 100 SEATED HOSTEL FOR PRAYAS GOVT. BOYS HIGH
SCHOOL FOR DIFFERENTLY ABLED, AT - DISTT:-PRATAPGARH (U.P.)
PART (A) - SCHEDULED ITEMS ( AS PER P.W.D. - 2018 )
S.No DESCRIPTION S.I. No QTY UNIT RATE AMOUNT
Category A
16 S/F of water tight oblong 10 Watt LED bulkhead luminaire with driver
set confirming to IP 65 and above Protection.complete in all respect.
CAT -AAA
ADD INDEX -
The MCCB's shall be Ics = 100% Icu, with rotary handle & pad
locking arrangement, with trip setting as per load requirement. TP
MCCB shall be with solid isolable neutral link. The breaking
capacity specified is Ics value. All incoming MCCB's shall be
microprocessor based. All outgoing MCCB's shall be
thermomagnetic type. All outgoing MCB's shall be C type with 10
KA breaking capacity.
2 x 11 watt CFL (Philips FCS 518/211 - Lotus) 135 Nos 1,150.00 155,250.00
DETAILED ESTIMATE OF PROPOSED 100 SEATED HOSTEL FOR PRAYAS GOVT. BOYS HIGH
1 VER.,ENT.LOBBY 4 - - 1 - - 2 2
2 2 NOS STAIR 2 - 2 - - 2
3 DINNING HALL 4 - 4 2 - - 4
4 KITCH / STORE/VER./TOI. 7 - - 5 1 1 1 6 1
5 VISITOR MEDICAL ,TOI. 3 1 2 2 1
6 RECEPTION 4 - 2 1 - - 2 2
7 OFFICE 2 - 1 1 1 - 1 1
8 BED ROOM & TOI. KIT. 3 - 1 3 2 - 3
9 GUARD ROOM - 2NOS 4 - 2 2 - 4
10 ROOM - 13NOS 39 - 26 26 - 13 26
11 TOILET - 2NOS 10 4 2 10
12 H. TOILET 1 1 1
13 CORRIDOR 12 9 12 1
FIRST FLOOR
TOILET - 2NOS 10 4 2 10
STAIR 1 - 1 - - 1
ROOM - 12NOS 36 - 24 24 - 12 24
READING ROOM - 1NOS 2 2 4
CORRIDOR 9 7 9
TOTAL 151 0 63 97 4 5 3 89 65 0 0 0
ABSTRACT AND TOTAL LOAD
PROVISION OF CIRCUITS
4 WAY TPN 4 2 3
6 WAY TPN 6 2 3
TOTAL CIRCUITS
TOTAL LOAD
6040.00
3780.00
5820.00
4000.00
300.00
0.00
19940.00
15
13
32
24
36
60
DETAILED MEASURMENT OF ELECTRICAL INSTALLATIONS
DETAILED ESTIMATE OF PROPOSED 100 SEATED HOSTEL FOR PRAYAS GOVT. BOYS HIGH
SCHOOL FOR DIFFERENTLY ABLED, AT - DISTT:-PRATAPGARH (U.P.)
PART (A) - SCHEDULED ITEMS ( AS PER P.W.D. - 2016 )
S.No DESCRIPTION QTY UNIT
245 NOS
2 Same as in item no. 1 but for two way light. 3 NOS
3 Same as in item no. 1 but for fan. and light duty exhaust fan
117 NOS
4 Same as in item no. 1 but for 5 amp plug point with piano type
switch & socket etc.
125 NOS
5 Supply & fixing of power plug with 15 amp 250 volts flush type
switch & 3 pin 15 amp 250 volts flush type socket in suitable M.S.
box of 175 mm * 100mm * 50 mm size with bakelite sheet cover
3 mm thick fixed with brass machine screws & washers complete
in all respect.
100 NOS
6 Supply & wiring of sub main with FR P.V.C. insulated 1100
volts grade single core copper conductor cable in heavy gauge
rigid steel coduit partly concealed in wall and partly laid in slab
along with the reinforcement before concreting complete with
one no. 14 SWG copper earth continuity wire complete in all
respects.
12 WAYS 25 NOS
9 S/F of surface/flush mounting TPN distribution board without
MCB complete in all respect as directed at site by Engineer-in-
charge..
6 WAYS 2 NOS
10 Supply & fixing of 6/10/16/20/25/32 amp. SP MCB (10 KA)
110 NOS
11 Supply Fixing and making commection of 30 MA E.L.C.B. (Earth
leakage circuit breaker) of din/R.C.C.B. rail mounting complete in
all respects as per direction and satisfaction of engineer-in-charge.
Category A 5 NOS
16 S/F of water tight oblong 10 Watt LED bulkhead luminaire with driver
set confirming to IP 65 and above Protection.complete in all respect.
CAT -AAA
Category AA 10 NOS
17 Erection and testing of ceiling fan and regulator etc excluding
supply of down rod, complete in all respect.
82 NOS
18 Erection and testing of exhaust fan on the existing hole with
suitable size of rag bolts nuts and washers etc complete in all
respects.
35 NOS
19 Supply and fixing of 16 gauge MS drum duly painted including
making hole in the wall for exhaust fan and finishing properly
complete in all respect.
10 NOS
20 S/F of hexagonal fan box with hexagonal side of approx. 80 mm.in
length fabricated from 16 SWG M.S. sheet incorporating with 10
mm. dia. M.S. round bar duly bent for supporting fan hanger duly
painted with red oxide and screwing arrangement with wiring
conduit laid in the R.C.C. roof before concreting along with
supply of all materials, labour, T&P etc. for proper completion of
work.
82 NOS
21 S/F of danger board fabricated from 10 gauge M.S. sheet as per
E/I rules. 1 NOS
22 S/F of shock treatment chart ( prescribed under I.E.rules ) duly
framed with glass and supported from back with hard board or soft
board with supply of all material labour T & P etc for proper
completion of work.
1 NOS
23 Supply and laying of 1800 mm x 900 mm x 20 mm thick
chequered rubber matting of tested quality.
1 NOS
T O T A L (SCHEDULED ITEMS -
RG - 6 F 125 M
3 Design, manufacture, supply, installation, testing and
commissioning of Main Distribution Board fabricated out of
16 SWG CRCA sheet steel, wall / floor mounting type. The sheet
steel shall undergo minimum seven tank treatment followed by
finishing powder coating of min 60 micron thickness. the board
includes 415 V electrolitic Aluminium Bus Bar, removable gland
plates, cable glands, including connection with outgoing feeders
complete in all respect.
The MCCB's shall be Ics = 100% Icu, with rotary handle & pad
locking arrangement, with trip setting as per load requirement. TP
MCCB shall be with solid isolable neutral link. The breaking
capacity specified is Ics value. All incoming MCCB's shall be
microprocessor based. All outgoing MCCB's shall be
thermomagnetic type. All outgoing MCB's shall be C type with 10
KA breaking capacity.
S.No. DESCRIPTION OF ITEM NO. L(M) B (M) H(M) QTY UNIT RATE AMOUNT
TOTAL-A+B1+C 217534.82
COST FOR 2 NOS. SEPTIC TANK & SOAK PIT 2 NOS. 217534.82 435069.64
DETAILED ESTIMATE OF SOAK PIT
ABSTRACT OF COST
S.N. DESCRIPTION OF ITEM NO. L(m) B (M) H(M) QTY UNIT RATE AMOUNT
SOAK PIT
TOTAL 50222.634
BILL OF QUANTITY OF PROPOSED BOUNDARY WALL (4.06 M., 1.80 HT. )
1. Earth work in exacavation in trenches
for foundations and for pipes cables etc.
in ordinary soil ( loan clay orsand)
including lift upto 1.5 m and leadup to
30m.&including filling watering& ramming
of excavated earth in to trenches or in
to the space between the building & the
sides of foundation trenches or in to
the plinth and removal & disposal of
surplus excavated earth as directed by
the Engineer i/c upto a distance of 30 m
from the foundation trenches. (PWD251)
2.28 CUM #REF! #REF!
2. Providing and laying in cement concrete 0.00
1:4:8 (1 cement :4 fine sand :8 graded 0.00
stone ballast 40 mm nominal size) and 0.00
curing complete,including cost of form 0.00
work,in foundation and floors.(PWD281) 0.00
0.46 CUM 4750.00 2169.56
3 R.c.c. work with cement approved coarse 0.00
sand and 2 cm. (3/4") guage approved 0.00
stone ballast in the proportion 1:6,(1 0.00
cement :6 aggregate) in lintels of doors 0.00
and windows excluding supply of 0.00
reinforcement and its fixing and binding 0.00
the same with 24 B WG binding wire and 0.00
including necessary centering and 0.00
shuttering etc.and also including supply 0.00
of all materials, labour and tools and 0.00
plants etc, required for proper 0.00
completion of the works. strength of the 0.00
concrete shall not beless than M200. 0.00
(PWD283(A) 0.21 CUM 8100.00 1701.85
4. Class 150 brick work in 1:6 cement and 0.00
coarse sand of mortar in foundation 0.00
and plinth including supply of all 0.00
materials,labour and tools and plants 0.00
etc.required for proper completion of the 0.00
work. (PWD303)
1.36 CUM 5500.00 7463.80
5. Same as in item no. 4 above but in 0.00
superstructure above plinth level up 0.00
to floor two level ( up to two storeys ) 0.00
including necessary cutting and 0.00
moulding of brick work as required 0.00
and also including honey combed brick 0.00
work in thickness of wall more than 12cms. 0.00
(PWD303+ 309+310) 0.00
0.15 CUM 6010.00 890.20
6. Same as in item no.5 but in 1:3 cement 0.00
and coarse sand mortar in superstructure 0.00
for wall thickness 12 cms & below. 0.00
(PWD 307+ 309+310A) 0.58 CUM 6224.00 3607.43
7. Mild steel or iron in plain work such as 0.00
reinforced concrete or reinforced, brick 0.00
work (when not included in anover all 0.00
rates ) wrought to required shape 0.00
as necessary including bending for proper 0.00
completion of the work and including 0.00
supply of steel its wastage bend hooks 0.00
and authorised over lapping shall be 0.00
measured upto floor two level. (PWD504) 0.00
0.25 QTL. 5800.00 1434.91
8 15 mm cement plaster in single coat on 0.00
fair side of single or half brick 0.00
wall for interior plastering up to
floor two level including brick wall
for interior plastering upto floor two
level including internal rounded angles
chamfers, and / or rounded angles not
exceeding 80 mm in girth and finished
even and smooth No. extra for mixing any
additive.(PWD586+596)
(1)1 cement : 6 fine sand
17.02 SQM 147.97 2518.68
9 Finishing walls with waterproofing on 0.00
cement paint of approved make such as 0.00
super snowcem,durrocem,robiacem,guttucem 0.00
supercem quality and of required shade 0.00
on undecorated wall surfaces (two coat) 0.00
overone and including one coat white 0.00
cement primer to give an even shade 0.00
after thoroughly brushing the surface to 0.00
powdered materials including curing and 0.00
cost of all materials.(PWD660+661) 0.00
17.02 SQM 59.00 1004.29
10 Fabrication of grill / stair case 0.000
railing. (PWD 502,c) 60.900 KG 57.00 3471.300
11 Painting Ist coat over priming coat (but
excluding cost of priming coat) on steel
and other metal surfaces up to 10 cm.
width or girth or small articles not
exceeding 0.10sqm in area white superior
synthetic enamel such as LUXOL3,Higloss
apcolite superlac, DULUX specified
brushing to give an even shade and
including cleaning the surface of all
dirt, dust and other foreign matter sand
papering and stopping including cost of
all materials, labour tools and plants
etc. required for proper completion of
the work.(PWD2014,Page22,S.No.1+2+4,iii+5) 4.87 SQM 95.50 465.28
TOTAL #REF!
3. R.C. C. band
Plinth 1 4.06 0.230 0.125 0.12
Top Band 1 4.06 0.230 0.100 0.09
TOTAL 0.21 CUM
4. B/W In foundation.
1 4.06 0.230 0.325 0.30
1 4.06 0.345 0.300 0.42
1 4.06 0.465 0.150 0.28
1 4.06 0.575 0.150 0.35
TOTAL 1.36 CUM
5. B/W in super-structure
2 0.230 0.230 1.40 0.15
TOTAL 0.15 CUM
6. B/W in super-structure (115 thick)
2 1.800 0.115 1.40 0.58
TOTAL 0.58 CUM
7. M. S. work in R.C.C. up to floor level.
qty same as item no (3)*1.5*0.785 0.25
TOTAL 0.25 QTL
8. 12 mm cement plaster
2 4.060 1.800 14.62
4 0.115 1.400 0.64
4 1.800 0.115 0.83
1 4.060 0.230 0.93
TOTAL 17.02 SQM
9. Snowcem.
2 4.060 1.800 14.62
4 0.115 1.400 0.64
4 1.800 0.115 0.83
1 4.060 0.230 0.93
TOTAL 17.02 SQM
1 Fabrication of grill / stair case 0.000
railing. (PWD 502,c) 60.900 KG 57.00 3471.300
2 Painting Ist coat over priming coat (but
excluding cost of priming coat) on steel
and other metal surfaces up to 10 cm.
width or girth or small articles not
exceeding 0.10sqm in area white superior
synthetic enamel such as LUXOL3,Higloss
apcolite superlac, DULUX specified
brushing to give an even shade and
including cleaning the surface of all
dirt, dust and other foreign matter sand
papering and stopping including cost of
all materials, labour tools and plants
etc. required for proper completion of
the work.(PWD2014,Page22,S.No.1+2+4,iii+5) 4.87 SQM 95.50 465.28
TOTAL 3936.58
2 Painting on grill
DETAILED ESTIMATE OF PROPOSED PRAYAS GOVT. BOYS HIGH SCHOOL FOR DIFFERENTLY ABLED
(SCHEDULED ITEMS AS PER D.S.R. 2016)
S.N. Description D.S.R. -2016 Qty. Unit Rate (Rs.) Amount (Rs.)
PART A
1 Earth work in excavation by mechanical means
(Hydraulic excavatior)/manual means over
areas(exceeding 30cm in depth. 1.5m in width as
well as 10sqm on plan) including disposal of
excavated earth, lead upto 50m and lift upto
1.5m, disposed earth to be levelled and neatly
dressed.
In all kind of soil upto 1.5m depth 2.6.1 16.033 Cum 125.95 2019.36
In all kind of soil upto 1.5m to 3.0m. depth 2.6.1&2.26.1 16.033 Cum 177.70 2849.06
In all kind of soil upto 3.0m to 4.5m. depth 2.6.1&2.26.2 12.792 Cum 218.75 2798.25
PART B
TOTAL 27398.40
6. Shuttering work
3.14*1.845*1.845 2 2.880 10.689 SQM.
PART B
4 NOS.
DETAILED ESTIMATE OF PROPOSED PRAYAS GOVT. BOYS HIGH SCHOOL FOR DIFFERENTLY
ABLED
for hostel
A) SCHEDULE ITEMS :
sand) for fire hydrants, with C.I. surface box 350x350mm top and
165mm deep (inside) with chained lid and RCC top slab 1:2:4 mix
(1 cement : 2 coarse sand : 4 graded stone aggregate 20mm
nominal size) necessary excavation foundation concrete 1:5:10 (1
cement :5 fine sand : 10 graded stone aggregate 40mm nominal
size) and inside plastering with cement mortar 1:3 (1 cement :
3 coarse sand ) 12mm thick finished with a floating coat of neat
cement complete as per standard design. 2 Each 6529.70 13059.40
TOTAL ( A ) Rs 59454.65
B) (NON-SCHEDULE ITEMS)
1 S/I/T/C stand post type fire hydrant with 63mm. outlet complete
with bolts, nuts and rubber insertions etc. as per the standard
design conforming to 15-908-'75.
2 Each 6000.00 12000.00
1 Supply, erection and testing of ISI marked M.S pipes (Class B) and
specials etc. (as per IS : 1239) for above ground laying for
hydrants and sprinkler system including transportation of materials
upto the worksite, cutting the pipes to required length, edge
preperation, welding, fixing/erection of pipes with suitable flat/angle
iron including specials i.e. bends tees, reducers, flanges etc. in
proper position including all supports as per layout, including
hangers for sprinkler piping, jointing by welding, aligning the pipe
line, painting with a primer coat and two coats of synthetic enamel
fire red colour, providing tapping for pressure gauges and for other
instruments etc. Hydrostatic testing of system as specified, flushing
& cleaning by water etc. complete as per drawings & direction of
the Engineer-in-charge. The quoted rats shall also include for
making holes in masonry/RCC slab, wall, chases in wall etc. &
making good the same to original conditions.
MAKE : Jindal(Hissar)/ Bharat/Indian Tube/ Prakash)
a) 100mm 35 M 1000.00 35000.00
2 Supply & fixing in position ISI marked cast iron double flanged
butterfly valves as per IS :13095, suitable for pressure 15 KG/cm2
including transporting to worksite, supply & fixing nuts, bolts,
gaskets, flanges & washers etc including testing, complete as per
drawing & directions of the Engineer-in-charge. (MAKE : Kirloskar/
Venus/IVC/Zaloto/Kalpna)
100 MM NB 1.00 Nos 5500.00 5500.00
3 Supply & fixing in position ISI marked cast iron double flanged Non
Return Valves as per IS 5312, part -I including transportation to
worksite, supply & fixing nuts, bolts gaskets and washers etc,
complete with testing as per direction of the Engineer-in-charge.
(MAKE : Kirloskar/ Venus/IVC/Zaloto/Kalpna)
100 MM NB 1.00 Nos 4250.00 4250.00
long and 63 mm dia with ISI marked (IS : 903) gun metal male and
female coupling complete as required. (Make : Jayshree/Newage) 2.00 Nos 5500.00 11000.00
7 Providing & fixing standard firemans axe with heavy rubber handle.
1.00 Nos 1000.00 1000.00
9 S/I/T/C air vessel of suitable capacity made out of 6mm. thick MS.
sheet with legs for bolting wall drain cock etc. complete in all
respects. 1.00 Each 7500.00 7500.00
SUB HEAD-II
1 Supply and fixing in position of the following type fire extinguishers.
A) SCHEDULE ITEMS :
TOTAL ( A )
B) (NON-SCHEDULE ITEMS)
1 S/I/T/C stand post type fire hydrant with 63mm. outlet complete
with bolts, nuts and rubber insertions etc. as per the standard
design conforming to 15-908-'75. 2 Each
SUB HEAD-I
1 Supply, erection and testing of ISI marked M.S pipes (Class B) and
specials etc. (as per IS : 1239) for above ground laying for
hydrants and sprinkler system including transportation of materials
upto the worksite, cutting the pipes to required length, edge
preperation, welding, fixing/erection of pipes with suitable flat/angle
iron including specials i.e. bends tees, reducers, flanges etc. in
proper position including all supports as per layout, including
hangers for sprinkler piping, jointing by welding, aligning the pipe
line, painting with a primer coat and two coats of synthetic enamel
fire red colour, providing tapping for pressure gauges and for other
instruments etc. Hydrostatic testing of system as specified, flushing
& cleaning by water etc. complete as per drawings & direction of
the Engineer-in-charge. The quoted rats shall also include for
making holes in masonry/RCC slab, wall, chases in wall etc. &
making good the same to original conditions.
MAKE : Jindal(Hissar)/ Bharat/Indian Tube/ Prakash)
a) 100mm 35 M
2 Supply & fixing in position ISI marked cast iron double flanged
butterfly valves as per IS :13095, suitable for pressure 15 KG/cm2
including transporting to worksite, supply & fixing nuts, bolts,
gaskets, flanges & washers etc including testing, complete as per
drawing & directions of the Engineer-in-charge. (MAKE : Kirloskar/
Venus/IVC/Zaloto/Kalpna)
100 MM NB 1.00 Nos
3 Supply & fixing in position ISI marked cast iron double flanged Non
Return Valves as per IS 5312, part -I including transportation to
worksite, supply & fixing nuts, bolts gaskets and washers etc,
complete with testing as per direction of the Engineer-in-charge.
(MAKE : Kirloskar/ Venus/IVC/Zaloto/Kalpna)
100 MM NB 1.00 Nos
6 Providing ISI marked RRL (IS: 636 type-II) fire hose pipe 15 meter
long and 63 mm dia with ISI marked (IS : 903) gun metal male and
female coupling complete as required. (Make : Jayshree/Newage) 2.00 Nos
7 Providing & fixing standard firemans axe with heavy rubber handle.
1.00 Nos
7 S/I/T/C of fire brigade inlet connection as per standard practice. 1.00 Each
SUB HEAD-II
1 Supply and fixing in position of the following type fire extinguishers.
complete with bracket, Bolts and initial charge as per IS 940.-- 4 Each
A.R.-II
Analysis of rate for contruction of apron drain ( 150*150 mm size, For 1.00m. Length )
5. Plaster 12 mm thick.
1:4(cement / fine sand)584+(583-582)
1*1*(2*0.115+2*0.15) D.S.R-13.4.1 0.530 sqm. 138.00 73.14
TOTAL 454.64
Say 454.64 / RM