Вы находитесь на странице: 1из 4

3.5.1.

Connection
The connection is designed using bolt and plywood plate. The diameter of
bolt used is 2 mm with Fyb = 320 MPa. The thickness of the plywood plate is 3
mm. The following is shown the number of bolt needed.

Figure 3.14 The Joint Label of Argajati Bridge

Table 3.3 The Number of Bolt Needed


Zu/(Z*x
No
Z* (N) Zu faktor baut
Batang
koreksi)
1 97,77 270,35 3,19 3
2 97,77 270,35 3,19 3
3 97,77 438,75 5,17 5
4 97,77 270,35 3,19 3
5 97,77 270,35 3,19 3
6 86,91 382,39 5,07 5
7 94,11 445,37 5,46 5
8 97,77 425,37 5,02 5
9 94,11 445,37 5,46 5
10 86,91 382,39 5,07 5
11 78,22 0,44 0,01 1
12 86,91 228,72 3,03 3
13 78,22 18,65 0,27 1
14 85,64 10,72 0,14 1
15 85,64 10,72 0,14 1
16 78,22 18,65 0,27 1
17 86,91 228,72 3,03 3
18 78,22 0,44 0,01 1
Connection Calculation
a) Data:
Zu = 270,35 N
D (Diameter of bolt) = 2 mm
l (Length of bolt) = 30 mm
tm = 10 mm
ts = 10 mm
Fyb (Yield strength ) = 320 Mpa

b) Applicabilityof Adjustment Factors:


CM (Wet service factor) =1 (AWC-NDS2015)
Ct (Temperature factor) =1 (AWC-NDS2015)
CG (Group action factor) =1 (AWC-NDS2015)
Cd (Penetration depth factor) =1 (AWC-NDS2015)
Ceg (End grain factor) = 0,67 (AWC-NDS2015)
Ctn (Toe-nail factor) =1 (AWC-NDS2015)
Kf (Format conversion factor) = 3.32 (AWC-NDS2015 Table 2.3.5)
Φz (Resistance factor) = 0.65 (AWC-NDS2015)
λ (Time effect factor) = 0.8 (AWC-NDS2015 App N.3.3)

c) Steps of Calculation
1. Side bearing strength (Fes)
FeII = 70 x G
= 70 x 0.28
= 19.6 MPa

2. Main bearing strength (Fem)


185 𝑥 𝐺 1.45
Fes﬩ =
√𝐷
185 𝑥 0.281.45
=
√2
= 20,656 MPa
3. Re
𝐹𝑒𝐼𝐼 19.6
Re = = = 0.949
𝐹𝑒𝑠﬩ 20,656

4. Rt
𝑙𝑚 5
Rt = = =1
𝑙𝑠 5
5. Reduction term (Rd)
a. Rd ( Im, Is) = 4Kø
= 4*(1+0,25(ø/90))
=4
b. Rd ( IIIm, IIIs, IV)
= 3,2Kø
= 3,2*(1+0,25(ø/90))
= 3,2

6. Lateral design values (Z)

𝐷 𝑥 𝑙𝑚 𝑥 𝐹𝑒𝐼𝐼
Zlm =
𝑅𝑑
2 𝑥 10 𝑥 19.6
Zlm =
4
Zlm = 98.00 N
2𝐷 𝑥 𝑙𝑠 𝑥 𝐹𝑒𝑠﬩
Zls =
𝑅𝑑
2 𝑥 2 𝑥 10 𝑥 20.656
Zls =
3.2
Zls = 206.56 N

2(1+𝑅𝑒) 𝐹𝑦𝑏(2+𝑅𝑒)𝐷 2
K3 = (−1) + √ +
𝑅𝑒 3 𝑥 𝐹𝑒𝐼𝐼 𝑥 𝑙𝑠2

2(1+0.949) 320(2+0.949)22
K3 = (-1) + √ +
0.949 3 𝑥 19.6 𝑋 102
K3 = 1.177
2𝑘3 𝑥 𝐷 𝑥 𝑙𝑠 𝑥 𝐹𝑒𝐼𝐼
ZIII3 = (2+𝑅𝑒)𝑅𝑑
2 𝑥 1.177 𝑥 2 𝑥 10 𝑥 19.6
ZIII3 =
(2+0.949)3.2
ZIII3 = 97.77

2 𝑥 𝐷2 2𝐹𝑒𝐼𝐼 𝑥 𝐹𝑦𝑏
Zlv = ( )√
𝑅𝑑 3(1+𝑅𝑒)

2 𝑥 22 2 𝑥 19.6 𝑥 320
Zlv = ( )√
2.2 3(1+0.949)
Zlv = 115.80 N

From the calculation of lateral design values, so we use Z = 97.77 N


7. Adjusted lateral design values (Z’)
Z’ = Z x Cm x Ct x Cg x C∆x Ceg x Фz x Kf x λ
Z’ = 97.77 x 1 x 1 x 1 x 1 x 1 x 1 x 1 x 0.65 x 0.8 x 3.32
Z’ = 168.79 N
8. Number of bolt
Zu ≤ n x Z’
270.35 N ≤ n x 168.79
3.19 ≤ n
So, Number of bolt is 3

d) Bolted Connection Geometry (AWC-NDS2015 Table 12.5.1D and Table


12.5.1E)
Diameter of bolt (D) = 2 mm
Length of fastener in wood member (l) = 5 mm

Table 3.4 Edge Distance and Spacing Requirement of Connection


Direction of Loading Minimum Edge Distance/ Value
Spacing
Parallel to grain 1.5D 3 mm
Perpendicular to grain (5l + 10D)/8 5 mm
Spacing 4D 8 mm

Вам также может понравиться