Академический Документы
Профессиональный Документы
Культура Документы
Ref: [1] EN1992-1-1, [2]Tall Building Structure by Smith & Coull The author will not be reponsible for any uses of this software!
[3] Second Order Effects on Building Structure & Structrural Analysis Multi-storey by Kollar v1.05
1.Inputs:
Job: Frame4 code= EC2 ACI or EC2
cracked factor fG= 0.7 for beam D0= 9E+06 MN.m2 =sum(Ecd*Ac*si^2), Ac=a*b
cracked factor fC= 0.7 for column N0= 22955 MN =7.837*ns/(ns+1.588)*D0 / L^2 - [Ref.3]
Note: fG: factor for cracked beam=2*0.35 or 0.5 (ACI), 0.5 (EC2) [Lb=beam length, Lc=column height=hs]
fC: factor for cracked column=0.35, uncracked column=0.70 (ACI), (0.4; 0.8) (EC2)
2. Result
b
Critical load of bracing system: Global stability ratio (λ) : Remark:
Wall: Ncr,w= 17 MN λw= 0.2 sway Kb= 1287 MPa =12*Eb*G/hs
Frame: Nc,f= 1024 MN λf= 13.8 non-sway Kc= 5000 MPa =fct*Ec*C/hs >> PDF
a
Wall+Frame: Ncr,w+f= 1040 MN (Southwell summation ) λm,f= 14.0 non-sway Kb/Kc= 0.257
a b
conservative result - [Ref.3] if λ>=10, global sectond order effect (PΔ effect - sway effect) can be ignored!