PRIMERGY RX300

November 2003

System configurator and order-information guide

Contents

Instructions
Configuration diagram
Configurator
0 System software
I Basic unit
II Processor
III Memory
IV Graphics
V Accessible drives
VI Hard disk drives
VII SCSI controller
VIII Disk array
IX Communication/Network
X System Management Products (RemoteView)
XI Miscellaneous
XII Country specific power cord
Change report

PRIMERGY Server
System configurator and order-information guide
PRIMERGY RX300 Status 2003-10-31

Instructions
This document contains basic product and configuration information that will enable you to configure your system via
PC-/System-Architect.

Only these tools will ensure a fast and proper configuration of your PRIMERGY server or your complete
PRIMERGY Rack system.

You can configure your individual PRIMERGY server in order to adjust your specific requirements.

The System configurator is divided into several chapters that are identical to the current price list and PC-/SystemArchitect.

Please follow the lines. If there is a junction, you can choose which way or component you would like to take. Go through
the configurator by following the lines from the top to the bottom.

Section III Memory, example

There are X memory slots which can be equipped with XXX MB.
It is permissible to make up to X passes through the memory upgrade options

S26361-XXX-XXX S26361-XXX-XXX
Memory XXX MB Memory XXX MB
X times

max. X times per system max. X times per system

In one chapter you can only select as many components (here 4x) as the arrow indicates. 4x

Please note that there are information symbols which indicate necessary information.

Further information in the internet see:

http://www.primergy.com (internet)

http://extranet.fujitsu-siemens.com/primergy (extranet)

Prices and availability see price list and PC-/System-Architect


Subject to change and errors excepted

Fujitsu Siemens Computers


SHV Server 2 of 19
System configurator and order-information guide
PRIMERGY RX300 Status 2003-10-31
Configuration diagram PRIMERGY RX300

System unit ( I )

1. PSU 2. PSU Fan 1 - Fan 4 Bay for Local View (frontside)

Fan 5 - Fan 8 3.5"x 0,5" Floppy disk

Redundant system-
Redundant power supply option fans Option
5,25"x 0,5" IDE-CD / DVD-ROM

Bank I (2 Modules)
Xeon DP Accessible drives ( V )
Bank II (2 Modules)

Bank III (2 Modules) Needs space for 2


Xeon DP hard disk drives!
Memory ( III ) 3.5"x1,6"

Processor ( II ) Backup drive option

Hard disk drives ( VI )


Extension slots channel 1

SCSI Controller ( VII )


Disk Array ( VIII ) 3.5"x1" ID 14
PCI-Bus

Communication/Network ( IX )
Miscellaneous ( X )

3.5"x1" ID 13
0 Slot5: PCI 64-Bit / 33MHz, short with Riser, 5V

RISER option 3.5"x1" ID 12


1 Slot4: PCI-X 64-Bit / 133MHz, Low Profile
channel 2 (optional)
Covered, if PCI-riser card ordered

0-channel-RAID (ZCR)
2 Slot3: PCI-X 64-Bit / 100MHz, Low Profile 3.5"x1" ID 2

HOT PLUG
3 Slot2: PCI 64-Bit / 100MHz, Low Profile 3.5"x1" ID 1

HOT PLUG
3 Slot1: PCI 64-Bit / 100MHz, Low Profile 3.5"x1" ID 0

Fujitsu Siemens Computers


SHV Server 3 of 19
System configurator and order-information guide
Start "PRIMERGY RX300" PRIMERGY RX300 Status 2003-10-31

SW - Configurator

with OEM-Software without OEM-Software


for PRIMERGY Server for PRIMERGY Server

Later use of OEM operating system software is not


allowed, apart from OEM software by VMware and F5 .

For all SW products listed below please refer to the corresponding software configurator accessible
via the Extranet under "PC Configurations, Configurator for PRIMERGY SW", URL see below

MS - Software: W **) SCO - Software: **) Novell - Software: ***) PRIMECLUSTER *)


- NT 4.0 Server - SCO UnixWare 7 - NetWare 6 - Clustering
- NT 4.0 Server Enterprise Edition - NetWare 6.5 (planned) - Load Balancing
- NT 4.0 Server Terminal Server Edition - NetWare Cluster Services 1.6 and
- Windows 2000 Server - NetWare Cluster Services 1.7
- Windows 2000 Advanced Server (planned) with FibreCAT
- Windows Server 2003, CX200, CX400, CX600
Web Edition (only English)
Standard Edition
Enterprise Edition Linux - Software: **)
- SuSE Linux Enterprise Server: S
- SuSE Professional Linux
CITRIX-Software for NT: W1 - Red Hat Enterprise Linux
- Multiuser SW MetaFrame - Red Hat Professional Linux
LoadBalancing
Additional User Licences

MultiPath, Duplex Data


Manager for NT; W2K; Linux

FSC System Management *) Pay attention to release information on datasheet under


Software: V http://www.primecluster.com
- RemoteView Software
- RemoteView Service Board
- RemoteView Diagnosis **) Pay attention to release and order information in PRINCE -> Operating System
http://vil.mch.fsc.net/vil/pc/vil/primergy/overview/prince/index_en.htm

Backup-Software: U
- ARCserve for NT ***) Supply over distribution or procurement from FSC VP BC Software
- ARCserve for NetWare

You'll find single software configurators and release lists (OS-matrix/system management/security) under following addresses:

for internal users: http://vil.mch.fsc.net/vil/oec/special/primergy/index_en.htm


for partners: http://vilpart.fujitsu-siemens.de/vil/oec/special/primergy/index_en.htm

Continue with PRIMERGY


HW configurator

Fujitsu Siemens Computers


Enterprise Products - PRIMERGY Server 4 of 19
System configurator and order-information guide
Start PRIMERGY RX300 PRIMERGY RX300 Status 2003-10-31

Section I Basic unit

System unit consisting of:


* 2U Housing including one power supply module
- hot plug Power supply unit with 1 PSU module and power cord rack 4m lenght
(can be upgraded with one additional PSU module)
* hot plug fan unit with 4 system-fans and control logic for 8 fans
- Additional hot plug system-fan unit with 4 fans as a redundant fans option (option)
* SCSI Backplane for 1x6 HD
- Additional upgrade Kit for 2x3 HD (Option)
* Drives/Bays
- 6 bays 1" for hot plug SCSI HD
- 1 bay for 3.5" and 1.6" high backup device, consumes 2 bays 1" for hot plug SCSI HD
- 2 bays (for accessible drives) with
- 1 floppy disk 1.44MB 0,5" height
- 1 IDE-CD-/DVD-ROM 0,5" hight (option)
- bay for opt. Local View Display on frontside
* Integrated ServerView Diagnostics Technology for indication of internal failed components
* Mounting kit for PRIMERGY RX300
- 1 pair of telescopic rails
- 2 holders
- 1 bracket DC-PC-Rack
- 1 cable management DC-PC-racks
Mounting kit for mounting of servers in FSC 19" DataCenter- and PRIMECENTER- racks and
all server racks conforming to EIA standard EIA-310-D for 19" racks.
Therefore the mounting kit is variable in deepth from 710-815mm
Systemboard with:
* One XEON CPU according to the configurator
* 5 PCI slots: 2x 64Bit / PCI-X100 low profile (3,3V), hot plug PCI
with OptiSpeed Bus (-> 133MHz if only one Slot is populated)
1x 64Bit/PCIX133 low profile (3,3V)
1x 64Bit/PCIX100 low profile (3,3V) (Slot for 0-channel RAID Controller, ZCR)
1x 64Bit/33MHz, short full hight (5V)
- 4 PCI Slots (Standard full hight PCI System - Option)
1x PCI 64Bit/33MHz short full hight (5 V)
3x PCI-X 64Bit/100MHz long full hight with PCI Subchassis (risercard option)
* 6 memory slots for max. 12GB PC2100 DDR RAM. (as soon as 2GB modules are available)
2-way memory interleave technology => 3 banks with 2 slots each, max. 2GB modul per slot
Additional Chipkill and Hot Spare Memory support for memory modules
* 0-channel RAID support for one 100MHz PCI-X slot (ZCR)
* Fast-IDE (ATA) controller on-board (for 2x2 drives)
* 2-channel Ultra 320 SCSI controller (Adaptec 7902) on-board
* 2* Gbit Ethernet LAN on-board (in chipset: BroadCom 5704 compatible)
* Graphics controller ATI Rage XL (8 MB RAM) on-board
* BMC ( Baseboard Management Controller ) Servermanagement Chip on-board
External Interfaces:
* 1x optional Centronics (parallel, 25 pin, EPP/ECP compatible)
* 1x keyboard (PS/2)
* 1x mouse (PS/2)
* 1x VGA (15 pin)
* 3x USB 1.1 (OHCI) with 12MBit/s (2x external at the rear, 1x at the frontside, no USB wakeup)
* 2x LAN RJ45
Cables:
1. IDE cable for CD/DVD.
2. Wide LVD SCSI cable for connection of the HD backplane.
3. Power cable
Software:
- ServerStart packet incl. ServerBooks CD, ServerSupport CD and ServerView

Cables included in basic unit


Connections Cable PRIMERGY RX300

1. IDE CD/DVD ¡ ¡

2. Backplane for 1x6


SCSI hard disks ¥ ¥
incl. terminator Key:
¥ 68pins
3. Power cable ¥ 68 or 50pins
¡ IDE
terminator

Fujitsu Siemens Computers


SHV Server 5 of 19
System configurator and order-information guide
A PRIMERGY RX300 Status 2003-10-31

Rack version for 19'' racks with


1 hot plug power supply module
Basic unit with
- 1x XEON DP (512kB SLC) processor
with 533MHz Frontside Bus (max. 2)
512MB DDR RAM PC2100 encluded
2,4GHz / 512kB S26361-K888-V101
2,66GHz / 512kB S26361-K888-V102
2,8GHz / 512kB S26361-K888-V103
3,06GHz / 512kB S26361-K888-V104
3,06GHz / 1M S26361-K888-V134
1GB DDR RAM PC2100 encluded
2,4GHz / 512kB S26361-K888-V111
2,66GHz / 512kB S26361-K888-V112
2,8GHz / 512kB S26361-K888-V113
3,06GHz / 512kB S26361-K888-V114
3,06GHz / 1M S26361-K888-V144
2GB DDR RAM PC2100 encluded
2,4GHz / 512kB S26361-K888-V121
2,66GHz / 512kB S26361-K888-V122
2,8GHz / 512kB S26361-K888-V123
3,06GHz / 512kB S26361-K888-V124
3,06GHz / 1M S26361-K888-V154

S26113-F600-E6
2nd power supply module (PSU)
for redundancy (500W) For later conversion the following kit is available:
incl. power cord for rack 1.) 1 power supply module 500W hot plug S26113-F600-L6
4m lenght incl. power cord for rack 4 m lenght
max. 1x per system

S26361-F2621-E3
Redundant Fans option

4 system hot plug fans in cage

max. 1x per system

Fujitsu Siemens Computers


SHV Server 6 of 19
System configurator and order-information guide
B PRIMERGY RX300 Status 2003-10-31
PRIMERGY 19" Rack

PRIMERGY PRIMECENTER-Rack

"Rack-mounting ex factory"
SNP:SY-F1647E301-P This service is to be ordered once
Installation ex works for one per installable server/storage
server or subsystem. subsystem, in order to get the
Hereby the rack will be delivered server/storage subsystem
completely pre-mounted and mounted into the PRIMERGY racks.
all wired connections are tested In case of the 46 U PRIMERGY rack,
With racks 12U, 24U, 38U: this service has to be ordered,
Systems and components to get the mounting kits and the
will be delivered installed in the rack cables installed.
With racks 46U:
Systems and components
will be delivered separately
To be ordered only together with
a PRIMERGY-
PRIMECENTER rack
e.g.: Important notice !
S26361-K826-V10x The mounting kit for PRIMERGY RX300
refer configurator PC-rack is included the basic version and
max. 1x per system will be delivered with every RX300

S26361-F1331-L93
Additional mounting kit for PRIMERGY42/23U Classic racks
containing 1 pair of spacer needed to adapt mounting kit
coming with RX300 for use in PRIMERGY Classic racks.
Fully fitting with RX300 is not allowed, free U needed to arange
cables.

Fujitsu Siemens Computers


SHV Server 7 of 19
System configurator and order-information guide
C PRIMERGY RX300 Status 2003-10-31

Section II Processor

There are 2 processor FCPGA slots available.


It is also possible to upgrade a dual-processor system later on.
Two processors with different clock frequencies are not possible

A multi-processor operating system is required for a dual-processor system.

S26361-F2827-E240 S26361-F2827-E260 S26361-F2827-E280


XEON 2.4GHz/533MHz FSB XEON 2.66GHz/533MHz FSB XEON 2,8GHz/533MHz FSB
with 512kB SLC on Chip, with 512kB SLC on Chip, with 512kB SLC on Chip,
heat sink heat sink heat sink

occupies slot for one CPU occupies slot for one CPU occupies slot for one CPU
max. 1x per system max. 1x per system max. 1x per system

S26361-F2827-E300 S26361-F3016-E300
XEON 3,06GHz / 533MHz FSB XEON 3,06GHz/533MHz FSB
with 512kB SLC on Chip, with 1M TLC on Chip
heat sink (TLC = Third Level Cache)
heat sink
occupies slot for one CPU occupies slot for one CPU
max. 1x per system max. 1x per system

Section III Memory

There are 6 memory slots available (3 banks, each bank consists of two slots => 2 modules per bank are necessary)
They can optionally be equipped with 256 MB, 512 MB, 1GB or 2GB registered PC2100 DDR modules
One bank optionally can be configured as hot spare bank.
In each basic unit the first memory bank is already equipped with either 512MB or 2GB memory,
so the memory extensions can still be configured up to two times for the second and third memory bank.
Maximum configurable memory extension is 10GB.
(this is possible with a 2GB basic unit + 2 x 4GB memory extensions ! )
The maximum extension of 12GB is possible through the order of a 512MB basic unit with 2 x 4GB memory
extensions and another order of a lose 4GB extension !
No mix of modules within one memory bank allowed.

S26361-F2762-E523 S26361-F2762-E524 S26361-F2762-E525 S26361-F2762-E526


Main memory 512MB Main memory 1GB Main memory 2GB Main memory 4GB
PC2100 registered DDR RAM PC2100 registered DDR RAM PC2100 registered DDR RAM PC2100 registered DDR RAM
2x with chipkill support with chipkill support with chipkill support with chipkill support
consisting of 2 modules consisting of 2 modules consisting of 2 modules consisting of 2 modules
occupies one bank occupies one bank occupies one bank occupies one bank
max. 2x per system max. 2x per system max. 2x per system max. 2x per system

For the upgrade of servers with Memory 4GB S26361-F2762-L526,


which were delivered before September 2003,
the Upgrade kit "air hood memory" (S26361-F3020-L10) is necessary.

Section IV Graphics

Graphics Controller ATI 8MB is included in the basic unit.


Other graphic cards only possible on PCI bus
by Customizing.

Fujitsu Siemens Computers


SHV Server 8 of 19
System configurator and order-information guide
D PRIMERGY RX300 Status 2003-10-31

Section V Accessible drives

SNP:SY-F2313E1-P SNP:SY-F2312E1-P
CD-ROM 0,5" 24xATAPI DVD drive 0,5"
Connector: LD50 8/24x or faster
incl. description (Ger/US) anthracite bezel
0.5" * 5.25", anthracite bezel occupies one drive bay
max. 1x per system max. 1x per system

S26361-F2233-E6 An option "hot plug backup drive", occupying


Tape drive DAT DDS4 hot plug 2 x 1" hard disk bays can be configured.
20GB, 2.8MB/s, U2W SCSI The hot plug backup drive requires a
1.6 x 3.5", anthracite bezel Zero-channel RAID controller
within a hot replace cage or a 1- or 2- channel U320 RAID controller
SCA connector (80-pins) (Adaptec or LSI).
occupies 2 x 1" hard disk bays
RAID controller necessary
max. 1x per system

Section VI Hard disks drives

The 80-pin SCA hard disks are plugged in a 1- or 2-channel backplane which is connected to the on-board SCSI
controller with a 68pin cable, if no other PCI-controllers are ordered.
If the option "hot plug backup drive" is configured only 4 bays for hard disks are available
hot replace is only possible with DAC and RAID setup.

S26361-F2764-E136 S26361-F2764-E173 S26361-F2764-E114


Hard disk 36GB Hard disk 73GB Hard disk 146GB
10000rpm,<5,5ms, 8MB Cache 10000rpm,<5,5ms, 8MB Cache 10000rpm,<5,5ms, 8MB Cache
Ultra 320 SCSI (320MB/s) Ultra 320 SCSI (320MB/s) Ultra 320 SCSI (320MB/s)
Interface: Wide SCA (80-pins) Interface: Wide SCA (80-pins) Interface: Wide SCA (80-pins)
hot plug/hot replace tray hot plug/hot replace tray hot plug/hot replace tray
occupies 1" bay occupies 1" bay occupies 1" bay
SCSI/RAID controller necessary SCSI/RAID controller necessary SCSI/RAID controller necessary
max. 6x (or 4x) per system max. 6x (or 4x) per system max. 6x (or 4x) per system

max. 6x (or 4x)

S26361-F2764-E518 S26361-F2764-E536 S26361-F2764-E573


Hard disk 18GB Hard disk 36GB Hard disk 73GB
15.000rpm,<4ms, 8MB Cache 15.000rpm,<4ms, 8MB Cache 15.000rpm,<4ms, 8MB Cache
Ultra 320 SCSI (320MB/s) Ultra 320 SCSI (320MB/s) Ultra 320 SCSI (320MB/s)
Interface: Wide SCA (80-pins) Interface: Wide SCA (80-pins) Interface: Wide SCA (80-pins)
hot plug/hot replace tray hot plug/hot replace tray hot plug/hot replace tray
occupies 1" bay occupies 1" bay occupies 1" bay
SCSI/ RAID controller necessary SCSI/ RAID controller necessary SCSI/ RAID controller necessary
max. 6x (or 4x) per system max. 6x (or 4x) per system max. 6x (or 4x) per system

S26361-F2612-E3
Conversion kit 6 hard disks 2 channel internal 2x3 conversion kit
2 SCSI channels will be internally
connected to 3 HDs each (2x3). Connections Cable Primergy RX300
Encludes 2nd SCSI-backplane
and 2nd SCSI-cable
Minimal configuration: 2nd backplane for ¥ ¥
1.) 2x onboard SCSI 1x3 SCSI hard disks
2.) 0-channel RAID controller encludes
3.) 1x 2-channel RAID controller terminator for 2nd
4.) 2x 1-channel RAID controller SCSI channel
5.) 1x 4-channel RAID controller
(2 internal channels)
max. 1x per system

Fujitsu Siemens Computers


SHV Server 9 of 19
System configurator and order-information guide
E PRIMERGY RX300 Status 2003-10-31

Section VII SCSI-/ Fibre-Channel Controller

on-board SCSI-controller for accessible drives and SCSI-HDs

The system is equipped with a two channel Utra 320 SCSI on board controller and embedded "HostRAID".
HostRAID offers the RAID levels 0, 1, 10 (striping and mirroring) witout any additional costs.
Per SCSI channel max. 2 RAID1 arrays with each two disks and one hot spare drive can be configured.
Administration of Host RAID will be done with the Adaptec Storage Manager Browser Edition.
HostRAID supports Windows 2000. Windows 2003 and LINUX are planned.
The simultaneous operation of the "Host RAID" function and the DDS4 (no hot Plug DDS4) at onboard SCSI
controller is only under W2K with the host RAID driver v.: 1.01a (or higher) possible.
1-channel standard SCSI-cabling of a basic unit PRIMERGY RX300 with on-board controller
1. One channel of the Ultra 320 SCSI controller is connected to the 6 internal hard disks, if no additional HD controllers are
(Two backplanes with 3 HDs each cascaded to one SCSI channel with 6HD`s = standard cabling).
configured for internal HDs.
2. The second channel of the Ultra 320 SCSI controller is available for internal accessible SCSI drives.
2-channel SCSI cabling of a PRIMERGY RX300 basic unit with on-board controller and "Conversion kit 6 HD 2-channel"
For the order of a "Conversion kit 6 HD 2-channel (S26361-F2612-E3)",
both channels of the Ultra 320 SCSI controller are connected to one backplane for 3 HDs each.
All internal cables and adapters for the basic unit and for components are included.
1x per RX300

T26139-Y3882-E101 If the internal HD are connected to a configurable controller (e.g. Disk Array),
External on-board SCSI Interface the channel of the on-board controller can also be used externally.
Cable and external
connector interface (UHD) Only SX30 Backup is released for the external connection
max. 1x per system for ext. of the on-board SCSI controller

More then 1x PCI standard slot short usage Only 1x PCI standard slot short usage Only 1x PCI standard slot short usage,
other PCI cards are low profile usage

S26361-F2622-E2
Standard PCI System with (encluded in basic unit)
PCI-risercard option incl. PCI-cage Low Profile System
(for 3 PCI-standard cards, long) 2x 64Bit / PCIX100 low profile (3,3V), hot plug PCI
3 Slots PCI-X 100MHz / 64 bit, long 1x 64Bit / PCIX133 low profile (3,3V)
1x 64Bit / PCIX100 low profile (3,3V), with EMRL

SCSI- and Fibre Channel controller for external drives and peripheral devices
while stocks last
S26361-F2843-E1 S26361-F2624-E1 S26361-F2399-E1
2GBit/s FC controller 2GBit/s FC controller SCSI 160 controller
Emulex Emulex Adaptec SCSI Card 29160
LP9802 LP9002L 1 channel: LVD + Fast/ Ultra (decoupl.)
1 Cannel 2GBit/sec FC controller 1 Channel 2GBit/sec FC controller LVD connect. for HD, without cable
3x LC Interface for 50um Fiber LC Interface for 50um Fibre Fast/Ultra connect. for acc. drives
PCI 64Bit / 133MHz, 170mm PCI 64Bit / 66MHz, 170mm 64/66 PCI, min 180 mm
3.3V and 5V tolerant signaling 3.3V and 5V tolerant signaling int: Fast 50 pol oder Ultra HD68
max. 3x per system max. 3x per system + LVD HD68; ext: HD68(LVD)
SW:
max. 2x per system

All controllers for the connection of external storage system are delivered without cables. Attention
For the configuration of external cabling see the configurator for external storage system. 2GBit/s FC controller
require other interface
3x, to be There are other components such as switches, GBICs or cables which can be ordered for connectors for the
continued fibre channel SAN attachments (see price list) optical cables than
on next page 1GBit/s fibre channel

Fujitsu Siemens Computers


SHV Server 10 of 19
System configurator and order-information guide
F PRIMERGY RX300 Status 2003-10-31

Section VIII Disk Array

3x, to be The fitting connection cables can be found in the The cables for the connection of the
continued configurator "external storage systems." RAID controller to HD backplanes in the
on previous system are included within the basic unit.
page Adaptec or Mylex / LSI controllers

1-channel U160 ( Mylex ) SCSI controller for Disk Array


Mixing Adaptec and Mylex / LSI controllers
is not supported S26361-F2406-E16
1-channel RAID controller U160
Mylex / LSI
AcceleRAID 160 (Bobcat)
16MB EDO Cache
without BBU
The cables for the connection from the connector: intern. HD68;
subsystems (SX30) to the RAID controllers extern: VHDCI
see configurator SX30. without cable
No SX30-release for 1-channel controllers! incl. SW and description (G/US)
32/33 PCI controller
3.3V and 5V tolerant signaling
max. 2x per system

1-channel U320 SCSI Controller for Disk Array

S26361-F3005-E64
1-channel RAID Controller U320
LSI
320-1
64MB SDRAM ECC Cache
BBU optional
plug: internal 1x HD68;
external: 1x VHDCI
without cable
incl. SW and description (Ger/US)
64/66 PCI controller, 180mm
3.3V and 5V tolerant signaling
max. 2x per system

S26361-F3005-E10
Cache Battery Backup Unit
max. 1x per controller

2-channel U160 ( Mylex ) SCSI controller for Disk Array

S26361-F2569-E64
2-channel RAID Controller U160
Mylex / LSI
AcceleRAID 352 (Leopard)
64MB SDRAM ECC Cache
The cables for the connection from the BBU optional
subsystems (SX30) to the RAID controllers Connector: internal 2x HD68;
see configurator SX30. external: 2x VHDCI
No S30-release for 1-channel controllers! without cable
incl. SW and description (Ger/US)
64/33 PCI Controller, 330mm
3.3V and 5V tolerant signaling
max. 2x per system

S26361-F2569-E10
RAID Ctrl, Battery Backup Unit
3x, to be max. 1x per controller
continued
on next page

G1 G2

Fujitsu Siemens Computers


SHV Server 11 of 19
System configurator and order-information guide
PRIMERGY RX300 Status 2003-10-31

G1 G2

3x, to be 2-channel Ultra 160 (Adaptec / U320 (LSI) SCSI controller for Disk Array
continued
on previous S26361-F2385-E32
page 2-channel RAID Controller U160
Adaptec
3200 S
32MB SDRAM ECC Cache
BBU optional
connector: internal 2x HD68;
external: 2x VHDCI
without cable
2x incl. SW and description (Ger/US)
64/33 PCI Controller, 330mm
3.3V and 5V tolerant signaling
max. 2x per system

S26361-F2386-E32
RAID Ctrl, Cache Upgrade 32MB
32 MB SDRAM ECC Cache
max. 1x per Controller

S26361-F2386-E10
RAID Ctrl, Battery Backup Unit
max. 1x per Controller

4-channel Ultra 160 SCSI controller for Disk Array

S26361-F2190-E128
4-channel RAID controller U160
Mylex / IBM
eXtremeRAID 2000 (Big Apple)
128MB SDRAM ECC Cache
BBU
connector: internal: 2x HD 68;
external: 4x VHDCI
incl. SW and description (G/USA)
64/33 PCI controller, 330 mm
3.3V and 5V tolerant signaling
max. 2x per system

Fujitsu Siemens Computers


SHV Server 12 of 19
System configurator and order-information guide
P PRIMERGY RX300 Status 2003-10-31

SCSI-/ Fibre-Channel Controller Low Profile

SCSI controller for external SCSI-HDs

S26361-F2737-E201
SCSI 160 controller, lp
Adaptec SCSI Card 29160LP
1 channel U160 LVD
only external connection
64/66(32/33) PCI Low Profile
ext: VHDCI, 68 pol., U160
SW:
max. 2x per system

Fibre Channel Controller for subsystems and SAN


while stocks last
S26361-F2624-E201 S26361-F2843-E201
2GBit/s FC controller 2GBit/s FC Controller
Emulex Emulex
LP9002L, PCI Low Profile LP9802, PCI Low Profile LP9802 only for Novell Netware.
1 Channel 2GBit/sec FC controller 1 Channel 2GBit/sec FC controller Microsoft and Linux Support
LC Interface for 50um Fibre LC Interface for 50um Fibre are in process.
PCI 64Bit/66MHz, 170mm PCI 64Bit / 133MHz, 170mm
3.3V and 5V tolerant signaling 3.3V and 5V tolerant signaling
max. 3x per system max. 3x per system

Attention There are other components


2GBit/s FC controller require such as switches, GBICs
other interface connectors or cables which can be
for the optical cables than ordered for fibre channel SAN
1GBit/s fibre channel. attachments (see price list)

All controllers for the connection of external storage system are delivered without cables.
4x, to be For the configuration of external cabling see the configurator for external storage system.
continued
on next page

Fujitsu Siemens Computers


SHV Server 13 of 19
System configurator and order-information guide
L PRIMERGY RX300 Status 2003-10-31

Disk Array Low Profile

Mixing Adaptec and Mylex / LSI controllers


Adaptec or Mylex / LSI controllers is not supported
4x, to be zero-channel U320 RAID controller for Disk Array
continued
on previous S26361-F2728-E248
page 0-channel RAID controller
Adaptec zero-channel RAID controller
2010S PCI Low Profile Adaptec 2010S is always to be
48MB SDRAM ECC Cache installed in slot 3 and is only available
for low profile configuration.
in combination with on-board
U320 SCSI controller
without cable
incl. SW and description (Ger/US)
64/66 PCI controller The cable for the connection of the
3.3V signaling RAID controller to HD backplane in the
max. 1x per system system is included within the basic unit.

1-channel U320 ( Adaptec ) / U160 ( Mylex ) SCSI Controller for Disk Array

S26361-F2751-E264 S26361-F2406-E216
1-channel RAID Controller U320 1-channel RAID Controller U160
Adaptec Mylex / LSI
2120S PCI Low Profile The cables for the connection from the Bobcat PCI Low Profile
64MB SDRAM ECC Cache subsystems (SX30) to the RAID Controllers 16MB EDO Cache
BBU optional see configurator SX30. without BBU
plug: internal 1x HD68; connector: intern. HD68;
external: 1x VHDCI extern: VHDCI
without cable without cable
incl. SW and description (Ger/US) incl. SW and description (G/US)
64/66 PCI controller, 180mm lp 1-channel RAID controller Adaptec 2120S 32/33 PCI Controller 180 mm
3.3V and 5V tolerant signaling may only be installed into slot 1 or 2 . max. 2x per system
max. 2x per system

1-channel U320 (LSI) SCSI controller for Disk Array


S26361-F2752-E10
Cache Battery Backup Unit S26361-F3005-E264
max. 1x per controller 1-channel RAID Controller U320
LSI
320-1 Low Profile
64MB SDRAM ECC Cache
BBU optional
2x plug: internal 1x HD68;
external: 1x VHDCI
without cable
incl. SW and description (Ger/US)
64/66 PCI Controller, 180mm lp
3.3V and 5V tolerant signaling
max. 2x per system
2-channel Ultra 320 ( Adaptec ) SCSI controller for Disk Array

S26361-F2752-E228 S26361-F3005-E10
2-channel RAID Controller U320 Cache Battery Backup Unit
Adaptec max. 1x per controller
2200S PCI Low Profile
128MB SDRAM ECC Cache
BBU optional
plug: internal 2x HD68; 2-channel RAID controller Adaptec 2120S
external: 2x VHDCI may only be installed into slot 1 or 2 .
without cable
incl. SW and description (Ger/US)
64/66 PCI controller, 180mm lp
3.3V and 5V tolerant signaling
max. 2x per system

S26361-F2752-E10
Cache Battery Backup Unit
max. 1x per controller

M Fujitsu Siemens Computers


SHV Server 14 of 19
System configurator and order-information guide
H PRIMERGY RX300 Status 2003-10-31

Section IX Communication / Network

On-board LAN Controller

Gigabit Ethernet Controller on-board Teaming: Failover, Load Balancing


2x 1GBit BMC5704 compatible The Intel LAN Controllers 10/100TX. 1000SX , 1000TX
Server Adapter, BroadCom can be used with the on-board controller in Teaming Mode
ext: for RJ 45-connector betrieben werden. Restriction with -F2839.
SW: AFT, VLAN, Fast Channel With Broadcom on-board adapters for Gigabit Ethernet must be used
for the teaming the Broadcom driver.
Two onboard LAN ports can likewise educate a team.
A) Adapters with Teaming capability 10-1000TX /SX

S26361-F2643-E1
Fast Ethernet Contr. 10/100TX
Intel Pro 100 Server Adapter
AFT under NT und NW also
with on-board LAN, WOL, load bal.
32/33 PCI, min. 120 mm, hp
ext: for RJ45-plug Note: Intel Pro/1000 MT
SW: VLAN, Fast Etherchannel Adapter may not be
max. 3x per system installed into slot 5.

S26361-F2732-E1 S26361-F2730-E1 S26361-F2839-E1


Gigabit Ethernet Contr. 1000SX Gigabit Ethernet Contr. 1000TX Gigabit Ethernet Contr. 1000TX
Intel Pro/1000 XF Server Adapter Intel Pro/1000 XT Server Adapter Intel Pro/1000 MT Adapter
Adapter Teaming Support Adapter Teaming Support PCI 32 (33/66MHz), min 122 mm
3x PCI-X (PCI64/66), min 163 mm PCI-X (PCI64/66), min 163 mm ext: for RJ45-plug, Cat 5
ext: for Duplex SC-connector ext: for RJ45-connector, Cat 5 connection with Cat 5 cabling
connection with Cat 5 cabling SW: VLAN, Fast Etherchannel
SW: VLAN, Fast Etherchannel SW: VLAN, Fast Etherchannel max. 3x per system
max. 3x per system max. 3x per system

B) Dual Port Adapter 100TX IPsec with 3DES (156 bit key) has export
restriction for several countries.
S26361-F2606-E1 No restriction to countries of the EU and:
Fast Ethernet dual 10/100TX IPsec - Australia,
Intel Pro 100S Dual Port Server - Japan,
Adapter, with IPsec 3DES - Canada,
AFT under NT, W2k, NW also - New Zealand,
with on-board LAN, WOL, load bal. - Norway,
64/66 bit PCI, min 120 mm, hp - Poland,
ext: for 2 x RJ45-connector - Switzerland,
SW: VLAN, Fast Etherchannel - Czechoslovakia,
max. 2x per system - Hungary
- United States

Fujitsu Siemens Computers


SHV Server 15 of 19
System configurator and order-information guide
I PRIMERGY RX300 Status 2003-10-31

C) Token Ring
while stocks last
S26361-F2117-E502
Token Ring Controller
Smart Ringnode MK4
100/16/4 Mbit, Madge
AFT (NT4, W2K) with 2 contr.,
2 redundant rings with 4 contr.
32/33 PCI, min. 164 mm
ext: for RJ45 or SUB-D9-plug
SW:
max. 2x per system

S26361-F1809-E1
ISDN S0 Controller PCI
Eicon Diva Server BRI-2M
Inkl. S0-connector
occupies short PCI slot
S0-Interface
max. 2x per system

S26361-F2571-E8
Parallel Port Option
Centronics
Cable with 25-pin plug
for a Centronics Parallel Port
Interface
max. 1x per system

Fujitsu Siemens Computers


SHV Server 16 of 19
System configurator and order-information guide
M PRIMERGY RX300 Status 2003-10-31

Communication / Network Low Profile

On-board LAN Controller

Fast Ethernet Controller on-board Teaming: Failover, Load Balancing


2x 1GBit BMC5704 compatible The Intel LAN Controllers 10/100TX. 1000SX , 1000TX
Server Adapter, BroadCom can be used with the on-board controller in Teaming Mode
ext: for RJ 45-connector betrieben werden. Restriction with -F2839.
SW: AFT, VLAN, Fast Channel With Broadcom on-board adapters for Gigabit Ethernet must be used
for the teaming the Broadcom driver.
Two onboard LAN ports can likewise educate a team.

S26361-F2732-E201 S26361-F2730-E201 S26361-F2839-E201


Gigabit Ethernet Contr. 1000SX Gigabit Ethernet Contr. 1000TX Gigabit Ethernet Contr. 1000TX
Intel Pro/1000 XF Server Adapter Intel Pro/1000 XT Server Adapter Intel Pro/1000 MT Adapter
Adapter Teaming Support Adapter Teaming Support PCI 32 (33/66MHz), min 122 mm
4x PCI-X (PCI64/66), min 163 mm PCI-X (PCI64/66), min 163 mm only for low prof. PCI
only for low prof. PCI only for low prof. PCI ext: for RJ45-connector, Cat 5
ext: for Duplex SC-connector ext: for RJ45-connector, Cat 5 connection with Cat 5 cabling
connection with Cat 5 cabling SW: VLAN, Fast Etherchannel
SW: VLAN, Fast Etherchannel SW: VLAN, Fast Etherchannel max. 4x per system
max. 4x per system max. 4x per system

In total may be configured to 4 pieces


of Ethernet Controller
(standard height + Low profile)

Fujitsu Siemens Computers


SHV Server 17 of 19
System configurator and order-information guide
J/N PRIMERGY RX300 Status 2003-10-31

Section X System Management Products (RemoteView)

S26361-F1790-E219
RemoteView Software V3.10
remote maintenance software, manual

S26361-F2425-E100
RemoteView Service Board
occupies 1* PCI slot
max. 1x pro System

S26361-F2425-E121 RemoteView external Power Supply


RemoteView Cables S26361-F2425-L300
Manual inclusive power cable G and power cable rack

S26361-F2116-E14
RemoteView Diagnosis
IDE Chipdisk
at the on-board IDE-Controller
occupies 1* IDE slot
max. 1x pro System

S26361-F2557-E102
LocalView Option Kit The LocalView Display is only released for
- LCD Display with mountingkit Microsoft operating systems and
- 2 x 20 char. ServerView Agents from version 2.57.06 on !"
max. 1x per system

Section XI Miscellaneous

S26361-F1652-L4 In connection with rack configurations


Modem external 56kbps (V.90) the install variant of the modem
MultiTech (S26361-F1652-E4) has to be ordered
MT5643ZBA-Global (see rack configurator)
international approval
incl. 2m Telephon cord RJ11/RJ11
Adapter Plug RJ11/TAE
Serial Interface cable DB25m / DB9f
AC-Adapter w. German Power Cord
occupies one COM port
max. 1x per system

Section XII Country specific power cord

Options and other peripherals


For other options, refer to separate "Product specific options"
These options are supplied lose with the shipment
For suitable peripherals for this product, please refer to the section "Peripherals/communication"

Country specific power cords are not required for rack versions, except for USA&Canada.
Power cords are shipped in a rack version with inlet connector for non-heating apparatus.
Description in englisch. Both included in basic unit.
(1x with Standard PSU, 2x with hot plug upgrade)

T26139-Y1742-E10 USA, Canada


For shipments to USA&Canada, you have to order
one power cord (1,8m, grey) per power supply.

End PRIMERGY RX300

Fujitsu Siemens Computers


SHV Server 18 of 19
System configurator and order-information guide
PRIMERGY RX300 Status 2003-10-31

Change Report
Date Order number Changes

2003-10-31 SNP:SY-F2244E2-A 1GBit/s FC controller Qlogic QLA 2200F - no longer available


2003-10-31 SNP:SY-F2244E1-A 1GBit/s FC controller Qlogic QLA 2200 - no longer available
2003-10-21 S26361-F3006-E127 Main memory 4GB PC2100 registered DDR RAM - now available
2003-10-20 S26361-F3006-E128 2-channel RAID controller U320 LSI - not available
26.09.2003 S26361-F2843-E201 2GBit/s FC Controller Emulex LP9802 Low Profile - now max. 3x per system possible
26.09.2003 S26361-F2624-E201 2GBit/s FC Controller Emulex LP9002 Low Profile - now max. 3x per system possible
26.09.2003 S26361-F2843-E1 2GBit/s FC Controller Emulex LP9802 - now max. 3x per system possible
26.09.2003 S26361-F2624-E1 2GBit/s FC Controller Emulex LP9002 - now max. 3x per system possible
2003-09-18 S26361-F2839-E201 Gigabit Ethernet Contr. 1000TX lp - now available
2003-09-18 S26361-F2839-E1 Gigabit Ethernet Contr. 1000TX - now available
2003-08-13 S26361-F3005-E264 1-channel RAID controller U320 LSI lp - now available
2003-08-13 S26361-F3006-E128 2-channel RAID controller U320 LSI - now available
2003-08-13 S26361-F3005-E10 Cache Battery Backup Unit - now available
2003-08-13 S26361-F3005-E64 1-channel RAID controller U320 LSI - now available
2003-08-07 S26361-F2752-E228 2-channel RAID controller U320 Adaptec 2200S lp - now available
2003-08-07 S26361-F2751-E264 1-channel RAID controller U320 Adaptec 2120S lp - now available
2003-08-07 S26361-F2752-E128 2-channel RAID controller U320 Adaptec 2200S - will not be available
2003-08-07 S26361-F2751-E64 1-channel RAID controller U320 Adaptec 2120S - will not be available
2003-08-07 S26361-F3016-E300 XEON DP processor 3,06GHz 1M/533FSB - now available
2003-08-07 S26361-K888-V154 Rack-version PY RX300f X/3.06/1M 2G - now available
2003-08-07 S26361-K888-V144 Rack-version PY RX300r X/3.06/1M 1G - now available
2003-08-07 S26361-K888-V134 Rack-version PY RX300f X/3.06/1M 512M - now available
2003-06-24 S26361-F2843-E201 2GBit/s FC Controller Emulex LP9802 PCI Low Profile - now available
2003-06-24 S26361-F2843-E1 2GBit/s FC Controller Emulex LP9802 - now available
2003-05-15 S26361-F2752-E228 2-channel RAID controller U320 Adaptec 2200S lp - as soon as available
2003-05-15 S26361-F2751-E264 1-channel RAID controller U320 Adaptec 2120S lp - as soon as available
2003-05-15 S26361-F2406-E216 1-channel RAID controller U160 Mylex / LSI Bobcat lp - now available
2003-05-15 S26361-F2816-E228 0-channel RAID controller Adaptec 2020 S lp - will not be available
2003-05-15 S26361-F2752-E10 Cache Battery Backup Unit - now available
2003-05-15 S26361-F2752-E128 2-channel RAID controller U320 Adaptec 2200S - as soon as available
2003-05-15 S26361-F2751-E64 1-channel RAID controller U320 Adaptec 2120S - as soon as available
2003-04-25 S26361-K881-V114 Rack-version with 1GB PC2100 DDR RAM 3.06GHz / 512kB - now available
2003-04-25 S26361-K881-V113 Rack-version with 1GB PC2100 DDR RAM 2.8GHz / 512kB - now available
2003-04-25 S26361-K881-V112 Rack-version with 1GB PC2100 DDR RAM 2.66GHz / 512kB - now available
2003-04-25 S26361-K881-V111 Rack-version with 1GB PC2100 DDR RAM 2.4GHz / 512kB - now available
2002-10-18 First draft

Fujitsu Siemens Computers


SHV Server 19 of 19