una carga de enfriamiento de 400Kw. B) repita el inciso a) si elcompresor tiene una eficiencia
T1 = 4 C
Calculos
Punto 1
T1 = 4 C fase: vapor saturado
P1= Ps = 339.52
Con T1 deter H1,vap sat = 400.728
S1,vap,sat = 1.72436
Punto 2
P2= 1000 kpa S liq, sat = 1.1878
S1 = s2, ideal =1.72436 S vap, sat = 1.7125
Det fase: S2> S vap,sat : vapor recalentado
H2,ideal = 423.2865
Punto 3
Fase: liq saturad xq todo el ciclo es ideal
P3= 1000 kpa T3 = 39.343
H3, liq sat = 255.527
Punto 4
H4 = H3 = 255.527
Balance en compresor
B.M: 𝑚1 =𝑚2 =m
𝑆2 =𝑆1
Condensador.
−𝑄𝑐𝑜𝑛𝑑
𝑚=
𝐻2, 𝑖𝑑𝑒𝑎𝑙 − 𝐻3
−400
𝑚= = 2.3843 𝑘𝑔/𝑠
423.2865 − 255.527
Evaporador
𝐻4 *𝑚4 - 𝐻1 *𝑚1 +𝑄𝑒𝑣𝑎𝑝 = 0
a) determinar C.O.P
𝑄𝑒𝑣𝑎𝑝𝑜𝑟𝑎𝑑𝑜𝑟
C.O.P. = = 346.2027/53.7862 = 6.4366
𝑊𝑖𝑑𝑒𝑎𝑙
𝑤 𝑖𝑑𝑒𝑎𝑙
𝑊𝑟𝑒𝑎𝑙 =
𝑛
Wreal = -107.5724
Wreal = m (𝐻1 - 𝐻𝑟𝑒𝑎𝑙 )
H 2,real = 𝐻1 - 𝑊𝑟𝑒𝑎𝑙 /n
H 2,real = 615.8728
Punto 2:
P2= 1000 kpa S real =2.2117 kj/kg k
H2,real =615.8728
Punto 3:
P3= 1000 kpa T3 = 39.343
H3, liq comp = 255.527
Condensador.
C) GRAFICA:
2.un recipiente de almacenamiento adiabatico de 0.2 m3 que inicialmente esta vacio, se
conecta con una linea de suministro que lleva nitrogeno a 225k y 10Mpa . se abre la valvula y
el nitrogeno fluye hacia el interior del recipiente. La valvula se cierra cuando la presion en el
Tent = 225k
P = 10 Mpa
Adiabatico Q = 0
v = 0.2 m3
vacio: ni= 0
Pf =10 M pa Tf =
Balance:
Sistema toda: tanque + valvula
B.M.
n ent = nf -ni
n ent = nf
B.E.
1 v 2 zg
1v2
zg 1v zg2 d (U + 2 g + g ) nsist
c c
𝑛ent (H + + ) − nsal (H + + ) + Q̇ − Ẇ =
2 g c g c ent 2 g c g c sal dt
nent *Hent = Uf *nf –U i* ni
nf *Hent = Uf *nf
Tent
nf*Cv ∗ ∫Tf cv ∗ dt + nf ∗ Pent Ṿent = 0
Tf = ((8.3144*225)/(0.745*28.013)) + 225
Tf= 314.639
Balance de entropia Q= 0
Sent n f + Sgen = Sf nf
acoplada que tambien esta impulsando un generador . el vapor de agua entra a la turbina a
12.5 Mpa y 500 C . a razon de 25 kg/s, y sale a 10kpa y una calidad de 0.92. El aire entra al
m= 10kg/s
agua en la turbina
m= 25kg/s
balance en el compresor:
naire*∆Hsal—ent = W
naire*Cp* (Tent-Tsal) = W
0.35625*Kmol/s *(28.18228*(295-620) )= W
Sgen = naire*(cp*In(Tsal/Tent)-R*In(Psal/Pent))
Sgen = 0.35625*(28.18228*In(620/295)-8.3144*In(1000/98))
Sgen = 0.57553 kj / k
Balance en la turbina
ment*Hent – msal*Hsal +Q –w =0
25Kg/s*(331.08-2393.2044) = W turbina
Wnet = 23696.89-2968.00625
W net = 20428.88375
B.S.
Sgen = 25*(7.5500-6.47035)
designed to operate in a location where the ocean water temperature is 25 C near the
surface and 5 C at some greater depth. The mass flow rate of the working fluid is 1000 kg/s.
a. determine the turbine power output and the pump power input for the cycle.
b. determine the mass flow rate of ocean water through cach heat exchanger
Punto 1
P1 = 857.5 kpa
Punto 4
Hliq = 274.30
Punto 3
P3 = 615.2 Kpa
S3 = 0.8779 kj/kg k
Punto 2
Punto 5
T5 = 5 C
H5 = 203.58 kj/ kg
Punto 6
T6 = 7 C
H6 = 212.936 KJ/kg
Balance en el condensador:
balance en turbina:
m1*H1 – m2*H3 + Q – W = 0
Wturbina = m ( H1 – H2)
W turbina = 1000*(1460.2-1418.72445)
Balance en el compresor
m* H4 – m H1 + m H20 *( H8 – H7 ) = 0
H4 = 239.91268
Balance en la turbina:
M3*H3 – m4*H4 + Q – w = 0
W bomb = m*( H3 – H4 )
W bomba = 1000*(226.97-239.91268)
W bomba = -12942.68 kj / s