Status:27.11.

2019
Nr. Pump for washing water

Water tank
+ 16.0 m

DN 65 DN 50

Pump-1 M/C - A side


DN 25

+ 12 m M/C - B side
DN 25

Note: All the liquids can contain bagacillo, rust, sand or scale particles

Basic design data unit


Medium: Water
Mass flow [t/h] 10.00
Density [t/m3] 0.0020 1.000
Temperature [°C] 0.00001 45.0
Dynamic viscosity [Pa s] 0.02 0.000890
Length of pipe [m] 100.0
Height of intake [mLC] 1.00
Pressure (inlet suction side) [bar] 1.00
Pressure (outlet pressure side) [bar] 1.20
Geodetic head [mLC] -4.0

Calculation of fluid velocity and pipe size Load factor 100% 100%

Volume flow rate [m3/h] 10.0 10.0


Velocity (set value) [m/s] 1.8 1.80
Pipe size (theoretical) [mm] 44 44
Chosen pipe size [mm] 50.0 50
Calculated velocity [m/s] 1.41 1.41

Calculation of delivery head Load factor 100% 100%

Pressure drop in the pipe [mLC] 7.36 7.36


Pressure drop of fittings, valves, etc. [Ceta ] 6.9 6.92
[mLC] 0.69 0.69
Pressure drop of china filter [bar] 0.00
[mLC] 0.00 0.00
Pressure drop of control valve [mLC] 0.00
Pressure (outlet pressure side - inlet suction side) [bar] 0.20 0.20
[mLC] 2.04 2.04
Geodetical head [mLC] -4.00 -4.00
Theoretical delivery head [mLC] 6.09 6.09
Safety addition [mLC] 0.00
Chosen delivery head [mLC] 6.09
[bar] 0.60
Remark: Without frequency convertor

Design data of the pump


Maximum volume flow rate [m³/h] 10
Delivery head [mLC] 6
NPSH (net positive suction head) of the plant [mLC] 10.55
mech. Leistung an der Welle (geschätzt) [KW] 0.3
Main Water washing pump, 28-11-2019, JS
Particular Unit Qty
Length of M/C (approx) mm 24000
Distance between each hole(approx) mm 25
No. of hole in one side(approx) no. 960
Total holes in A+B side no. 1920
Hole didmeter(approx.) mm 5

Flow velocity m/sec 1.8


Flow rate from one hole m3/sec 0.000035325
Total flow both side m3/sec 0.068
Time for washing sec 30
For hour flow m3/hr 8.139
% 25%
Extra margin
m3/hr 2.035

Total flow m3/h 10