Technical Specification

Flygt 3171, 60Hz


Table of Contents

Table of Contents
F-pump, Standard Motor............................................................................................................... 2
Product description.....................................................................................................................2
Motor rating and performance curves......................................................................................4

F-pump, Premium Efficiency Motor (IE3).....................................................................................8


Product description.....................................................................................................................8
Motor rating and performance curves................................................................................... 10

N-pump, Standard Motor............................................................................................................ 14


Product description.................................................................................................................. 14
Motor rating and performance curves 3171.181/.091/.185/.095.......................................17
Motor rating and performance curves 3171.660/.670.........................................................20

N-pump, Premium Efficiency Motor (IE3)................................................................................. 22


Product description.................................................................................................................. 22
Motor rating and performance curves 3171.800/.810/.820/.830.......................................25
Motor rating and performance curves 3171.860/.870.........................................................28

Dimensions and Weight, Standard Motor................................................................................ 30


Drawings.................................................................................................................................... 30

Dimensions and Weight, Premium Efficiency Motor (IE3)......................................................37


Drawings.................................................................................................................................... 37

Flygt 3171, 60Hz Technical Specification 1


F-pump, Standard Motor

F-pump, Standard Motor


Product description

Usage
A submersible chopper pump for liquid manure, fish waste, or heavily contaminated
sewage and sludge. The N-hydraulic is fitted with a cutting insert ring. Both impeller and
insert ring are manufactured in Hard-Iron™.
Denomination
Type Non-explosion proof Explosion proof Pressure class Installation
version version types
Hard-Iron™ 3171.350 3171.390 MT — Medium head P, S, T, Z
Chopper HT — High head
SH — Super head

The pump can be used in the following installations:


P Semi permanent, wet well arrangement with pump installed on two guide bars with
automatic connection to discharge.
S Portable semi permanent, wet well arrangement with hose coupling or flange for
connection to discharge pipeline.
T Vertical permanent, dry well arrangement with flange connection to suction and
discharge piping.
Z Horizontal permanent, dry well arrangement with flange connection to suction and
discharge piping.
Application limits
Feature Description
Liquid temperature Maximum 40°C (104°F)
Liquid temperature, warm water version Maximum 70°C (158°F)
Depth of immersion Maximum 20 m (65 ft)
pH of the pumped liquid 5.5 – 14
Liquid density Maximum 1100 kg/m3

2 Flygt 3171, 60Hz Technical Specification


F-pump, Standard Motor

Motor data
Feature Description
Motor type Squirrel-cage induction motor
Frequency 60 Hz
Power supply 3-phase
Starting method • Direct on-line
• Star-delta
• Variable Frequency Drive (VFD)
Number of starts per hour Maximum 30
Code compliance IEC 60034-1
Voltage variation • Continuously running: Maximum ±5%
• Intermittent running: Maximum ±10%
Voltage imbalance between Maximum 2%
phases
Stator insulation class H (180°C, 356°F)

Cables
Application Type
Direct-on-line start or Y/D start with two cables Flygt SUBCAB® - a heavy duty 4 cores motor power cable
with two twisted pair screened control cores. Conductor
insulation rating of 90°C, which allows for increased
current. Superior mechanical strength and high abrasion
and tear resistant. Chemical resistant within pH 3-10 and
ozone, oil, and flame resistant. Used up to 70°C water
temperature. Cables < 10 mm2 with unscreened control
cores.
Y/D start Flygt SUBCAB® - a heavy duty 7 cores motor power cable
with two twisted pair screened control cores. Conductor
insulation rating of 90°C, which allows for increased
current. Superior mechanical strength and high abrasion
and tear resistant. Chemical resistant within pH 3-10 and
ozone, oil, and flame resistant. Used up to 70°C water
temperature. Cables < 7G6 mm2 with unscreened
control cores.
Variable Frequency drive Screened Flygt SUBCAB® - a heavy duty 4 screened cores
motor power cable with four twisted pair screened control
cores. Conductor insulation rating of 90°C, which allows
for increased current. Superior mechanical strength and
high abrasion and tear resistant. Chemical resistant
within pH 3-10 and ozone, oil, and flame resistant. Used
up to 70°C water temperature.

Monitoring equipment
• Thermal contacts opening temperature 140° C (284° F)
• Leakage sensor in the inspection chamber (FLS 10)
Materials

Table 1: Major parts except mechanical seals

Denomination Material ASTM EN


Major castings Cast iron, gray 35B GJL-250
Pump housing Cast iron, gray 35B GJL-250
Impeller Cast iron, Hard-Iron ™
A 532 IIIA GJN-HB555(XCR23)

Flygt 3171, 60Hz Technical Specification 3


F-pump, Standard Motor

Denomination Material ASTM EN


Insert ring Cast iron, Hard-Iron™ A 532 IIIA GJN-HB555(XCR23)
Cooling jacket, inner Aluminum AA 1050A AW-1050A
Cooling jacket, outer, alternative Steel GR65 S235JRG2
1
Cooling jacket, outer, alternative Stainless steel AISI 316L 1.4404,1.4432, …
2
Lifting handle Stainless steel AISI 316L 1.4404,1.4432, …
Shaft Stainless steel AISI 431 1.4057+QT800
Screws and nuts Stainless steel, A4 AISI 316L, 316, 316Ti 1.4401,1.4404, …
O-rings, alternative 1 Nitrile rubber (NBR) 70° - -
IRH
O-rings, alternative 2 Fluorinated rubber - -
(FPM) 70° IRH
Glycol Heat transfer fluid based - -
on monopropylene
glycol.

Table 2: Mechanical seals

Alternative Inner seal Outer seal


1 Corrosion resistant cemented Corrosion resistant cemented
carbide/ Corrosion resistant carbide/ Corrosion resistant
cemented carbide cemented carbide
2 Corrosion resistant cemented Silicon carbide/ Silicon carbide
carbide/ Corrosion resistant
cemented carbide

Surface treatment
Priming Finish
Painted with a primer, see internal standard Navy gray color NCS 5804-B07G. Two-component high-
M0700.00.0002 solid top coating, see internal standard M0700.00.0004
for standard painting and M0700.00.0008 for special
painting.

Options
• Warm liquid version (non-explosion proof versions)
• Sensors: Thermistor, FLS, PT 100, VIS 10
• Surface treatment (Epoxy)
• Zinc anodes
• Other cables
Accessories
Discharge connections, adapters, hose connections, and other mechanical accessories.
Electrical accessories such as pump controller, control panels, starters, monitoring relays,
cables.

Motor rating and performance curves


These are examples of motor rating and curves. For more information, please contact
your local sales and service representative.
Star-delta starting current is 1/3 of Direct on-line starting current.

4 Flygt 3171, 60Hz Technical Specification


F-pump, Standard Motor

MT
P[hp]
2
/ [kW]
40

35 433
25
30 434

20
25 435

436
20 15
437
15

H [ft] / [m]

MT
100 30

80 25

20 433
60
15
40
10

20 434
5 435
436
437

0 0
0 20 40 60 80 100 120 140
0 500 1000 1500 2000 2500
Q [l/s] / [usgpm]
WS005118B

Table 3: 460 V, 60 Hz, 3–phase

Rated power, Rated power, Curve/ Revolutions per Rated Starting Power Installation
kW hp Impeller No minute, rpm current, A current, A factor, cos
φ
18.6 25 436 1755 30 183 0.89 P,S,T,Z
18.6 25 437 1755 30 183 0.89 P,S,T,Z
22 30 435 1755 36 231 0.87 P,S,T,Z
22 30 436 1755 36 231 0.87 P,S,T,Z
22 30 437 1755 36 231 0.87 P,S,T,Z
25 34 433 1755 40 256 0.9 P,S,T,Z
25 34 434 1755 40 256 0.9 P,S,T,Z
25 34 435 1755 40 256 0.9 P,S,T,Z
25 34 436 1755 40 256 0.9 P,S,T,Z
25 34 437 1755 40 256 0.9 P,S,T,Z

Flygt 3171, 60Hz Technical Specification 5


F-pump, Standard Motor

HT
P[hp]
2
/ [kW]

40 30
453
25 454
30
20 455

20 15
10
10

H [ft] / [m]

180 HT
160 50

140
40
120

100 30
453
80
20
60
454
455
40
10
20

0 0
0 10 20 30 40 50 60 70 80
0 200 400 600 800 1000 1200 1400
Q [l/s] / [usgpm]

WS005119B

Table 4: 460 V, 60 Hz, 3–phase

Rated power, Rated power, Curve/ Revolutions per Rated Starting Power Installation
kW hp Impeller No minute, rpm current, A current, A factor, cos
φ
18.6 25 455 1755 30 183 0.89 P,S,T,Z
22 30 454 1755 36 231 0.87 P,S,T,Z
22 30 455 1755 36 231 0.87 P,S,T,Z
25 34 453 1755 40 256 0.9 P,S,T,Z
25 34 454 1755 40 256 0.9 P,S,T,Z
25 34 455 1755 40 256 0.9 P,S,T,Z

6 Flygt 3171, 60Hz Technical Specification


F-pump, Standard Motor

SH
P[hp]
2
/ [kW]

40
28
35 275
24
30
20
25 277

16 278
20

H [ft] / [m]
250 SH
70

200 60

50
150
40

100 30

20
275
50
277
10 278

0 0
0 10 20 30 40 50
0 100 200 300 400 500 600 700 800 900
Q [l/s] / [usgpm]
WS005120B

Table 5: 460 V, 60 Hz, 3–phase

Rated Rated Curve/ Revolutions Rated Starting current, A Power Installation


power, kW power, hp Impeller No per minute, current, A factor, cos
rpm φ
26 35 275 3520 39 273 0.92 P,S,T,Z
26 35 277 3520 39 273 0.92 P,S,T,Z
26 35 278 3520 39 273 0.92 P,S,T,Z

Flygt 3171, 60Hz Technical Specification 7


F-pump, Premium Efficiency Motor (IE3)

F-pump, Premium Efficiency Motor


(IE3)
Product description

Usage
A submersible chopper pump for liquid manure, fish waste, or heavily contaminated
sewage and sludge. The N-hydraulic is fitted with a cutting insert ring. Both impeller and
insert ring are manufactured in Hard-Iron™.
Denomination
Type Non-explosion proof Explosion proof Pressure class Installation
version version types
Hard-Iron™ 3171.840 3171.850 MT — Medium head P, S, T, Z
Chopper HT — High head
SH — Super head

The pump can be used in the following installations:


P Semi permanent, wet well arrangement with pump installed on two guide bars with
automatic connection to discharge.
S Portable semi permanent, wet well arrangement with hose coupling or flange for
connection to discharge pipeline.
T Vertical permanent, dry well arrangement with flange connection to suction and
discharge piping.
Z Horizontal permanent, dry well arrangement with flange connection to suction and
discharge piping.
Application limits
Feature Description
Liquid temperature Maximum 40°C (104°F)
Depth of immersion Maximum 20 m (65 ft)
pH of the pumped liquid 5.5 – 14
Liquid density Maximum 1100 kg/m3

8 Flygt 3171, 60Hz Technical Specification


F-pump, Premium Efficiency Motor (IE3)

Motor data
Feature Description
Motor type Squirrel-cage induction motor
Frequency 60 Hz
Power supply 3-phase
Starting method • Direct on-line
• Star-delta
• Variable Frequency Drive (VFD)
Number of starts per hour Maximum 30
Code compliance IEC 60034-1
Voltage variation • Continuously running: Maximum ±5%
• Intermittent running: Maximum ±10%
Voltage imbalance between Maximum 2%
phases
Stator insulation class H (180°C, 356°F)

Cables
Application Type
Direct-on-line start or Y/D start with two cables Flygt SUBCAB® - a heavy duty 4 cores motor power cable
with two twisted pair screened control cores. Conductor
insulation rating of 90°C, which allows for increased
current. Superior mechanical strength and high abrasion
and tear resistant. Chemical resistant within pH 3-10 and
ozone, oil, and flame resistant. Used up to 70°C water
temperature. Cables < 10 mm2 with unscreened control
cores.
Y/D start Flygt SUBCAB® - a heavy duty 7 cores motor power cable
with two twisted pair screened control cores. Conductor
insulation rating of 90°C, which allows for increased
current. Superior mechanical strength and high abrasion
and tear resistant. Chemical resistant within pH 3-10 and
ozone, oil, and flame resistant. Used up to 70°C water
temperature. Cables < 7G6 mm2 with unscreened
control cores.
Variable Frequency drive Screened Flygt SUBCAB® - a heavy duty 4 screened cores
motor power cable with four twisted pair screened control
cores. Conductor insulation rating of 90°C, which allows
for increased current. Superior mechanical strength and
high abrasion and tear resistant. Chemical resistant
within pH 3-10 and ozone, oil, and flame resistant. Used
up to 70°C water temperature.

Monitoring equipment
• Thermal contacts opening temperature 140° C (284° F)
• Leakage sensor in the inspection chamber (FLS 10)
Materials

Table 6: Major parts except mechanical seals

Denomination Material ASTM EN


Major castings Cast iron, gray 35B GJL-250
Pump housing Cast iron, gray 35B GJL-250
Impeller Cast iron, Hard-Iron ™
A 532 IIIA GJN-HB555(XCR23)

Flygt 3171, 60Hz Technical Specification 9


F-pump, Premium Efficiency Motor (IE3)

Denomination Material ASTM EN


Insert ring Cast iron, Hard-Iron™ A 532 IIIA GJN-HB555(XCR23)
Cooling jacket, inner Aluminum AA 1050A AW-1050A
Cooling jacket, outer Stainless steel AISI 316L 1.4404,1.4432, …
Lifting handle Stainless steel AISI 316L 1.4404,1.4432, …
Shaft Stainless steel AISI 431 1.4057+QT800
Screws and nuts Stainless steel, A4 AISI 316L, 316, 316Ti 1.4401,1.4404, …
O-rings, alternative 1 Nitrile rubber (NBR) 70° - -
IRH
O-rings, alternative 2 Fluorinated rubber - -
(FPM) 70° IRH
Glycol Heat transfer fluid based - -
on monopropylene
glycol.

Table 7: Mechanical seals

Alternative Inner seal Outer seal


1 Corrosion resistant cemented Corrosion resistant cemented
carbide/ Corrosion resistant carbide/ Corrosion resistant
cemented carbide cemented carbide
2 Corrosion resistant cemented Silicon carbide/ Silicon carbide
carbide/ Corrosion resistant
cemented carbide

Surface treatment
Priming Finish
Painted with a primer, see internal standard Navy gray color NCS 5804-B07G. Two-component high-
M0700.00.0002 solid top coating, see internal standard M0700.00.0004
for standard painting and M0700.00.0008 for special
painting.

Options
• Sensors: Thermistor, FLS, PT 100, VIS 10
• Surface treatment (Epoxy)
• Zinc anodes
• Other cables
Accessories
Discharge connections, adapters, hose connections, and other mechanical accessories.
Electrical accessories such as pump controller, control panels, starters, monitoring relays,
cables.

Motor rating and performance curves


These are examples of motor rating and curves. For more information, please contact
your local sales and service representative.
Star-delta starting current is 1/3 of Direct on-line starting current.

10 Flygt 3171, 60Hz Technical Specification


F-pump, Premium Efficiency Motor (IE3)

MT
P[hp]
2
/ [kW]
40

35 433
25
434
30
20
25 435

20 15 436
437

15

H [ft] / [m]

MT
100 30

80 25
433
20
60
15
40
10

20 435
434
5 437
436

0 0
0 20 40 60 80 100 120 140
0 500 1000 1500 2000 2500
Q [l/s] / [usgpm]

WS004594A

Table 8: 460 V, 60 Hz, 3–phase

Rated power, Rated power, Curve/ Revolutions Rated Starting Power factor, Installation
kW hp Impeller No per minute, current, A current, A cos φ
rpm
18.6 25 436 1775 28 218 0.9 P,S,T,Z
18.6 25 437 1775 28 218 0.9 P,S,T,Z
22 30 435 1775 33 251 0.91 P,S,T,Z
22 30 436 1775 33 251 0.91 P,S,T,Z
22 30 437 1775 33 251 0.91 P,S,T,Z
25 34 433 1775 38 300 0.89 P,S,T,Z
25 34 434 1775 38 300 0.89 P,S,T,Z
25 34 435 1775 38 300 0.89 P,S,T,Z
25 34 436 1775 38 300 0.89 P,S,T,Z
25 34 437 1775 38 300 0.89 P,S,T,Z

Flygt 3171, 60Hz Technical Specification 11


F-pump, Premium Efficiency Motor (IE3)

HT
P[hp]
2
/ [kW]
40
453
25 454
30
20 455

20 15

10
10

H [ft] / [m]
160
HT
45
140
40
120
35
100 30
453

80 25

20
60
454
15 455
40
10
20 5

0 0
0 10 20 30 40 50 60 70 80
0 200 400 600 800 1000 1200 1400
Q [l/s] / [usgpm]

WS004595A

Table 9: 460 V, 60 Hz, 3–phase

Rated power, Rated power, Curve/ Revolutions Rated Starting Power factor, Installation
kW hp Impeller No per minute, current, A current, A cos φ
rpm
18.6 25 454 1775 28 218 0.9 P,S,T,Z
18.6 25 455 1775 28 218 0.9 P,S,T,Z
22 30 454 1775 33 251 0.91 P,S,T,Z
22 30 455 1775 33 251 0.91 P,S,T,Z
25 34 453 1775 38 300 0.89 P,S,T,Z
25 34 454 1775 38 300 0.89 P,S,T,Z
25 34 455 1775 38 300 0.89 P,S,T,Z

12 Flygt 3171, 60Hz Technical Specification


F-pump, Premium Efficiency Motor (IE3)

SH
P[hp]
2
/ [kW]

40
28
35 275

24
30
20
25 277

16 278
20

H [ft] / [m]
250 SH
70

200 60

50
150
40 275

100 30

20
50
277
10 278

0 0
0 10 20 30 40 50
0 100 200 300 400 500 600 700 800 900
Q [l/s] / [usgpm]

WS004596A

Table 10: 460 V, 60 Hz, 3–phase

Rated power, Rated power, Curve/ Revolutions Rated Starting Power factor, Installation
kW hp Impeller No per minute, current, A current, A cos φ
rpm
26 35 275 3530 38 284 0.93 P,S,T,Z
26 35 277 3530 38 284 0.93 P,S,T,Z
26 35 278 3530 38 284 0.93 P,S,T,Z

Flygt 3171, 60Hz Technical Specification 13


N-pump, Standard Motor

N-pump, Standard Motor


Product description

Usage
A submersible pump for efficient pumping of clean water, surface water, and wastewater
containing solids or long-fibered material. The pump is designed for sustained high
efficiency. For abrasive media, Hard-Iron™ is required. Stainless steel N-impeller is
available as an option.
Denomination
Type Non-explosion proof Explosion proof Pressure class Installation
version version types
Cast iron 3171.181 3171.091 LT — Low head P, S, T, Z
MT — Medium head
HT — High head
SH — Super head
Hard-Iron™ 3171.185 3171.095 LT — Low head P, S, T, Z
MT — Medium head
HT — High head
SH — Super head
Stainless steel 3171.660 3171.670 MT — Medium head P, S

The pump can be used in the following installations:


P Semi permanent, wet well arrangement with pump installed on two guide bars with
automatic connection to discharge.
S Portable semi permanent, wet well arrangement with hose coupling or flange for
connection to discharge pipeline.
T Vertical permanent, dry well arrangement with flange connection to suction and
discharge piping.
Z Horizontal permanent, dry well arrangement with flange connection to suction and
discharge piping.
Application limits
Feature Description
Liquid temperature Maximum 40°C (104°F)

14 Flygt 3171, 60Hz Technical Specification


N-pump, Standard Motor

Feature Description
Liquid temperature, warm water version Maximum 70°C (158°F)
Depth of immersion Maximum 20 m (65 ft)
pH of the pumped liquid 5.5 – 14
Liquid density Maximum 1100 kg/m3

Motor data
Feature Description
Motor type Squirrel-cage induction motor
Frequency 60 Hz
Power supply 3-phase
Starting method • Direct on-line
• Star-delta
• Variable Frequency Drive (VFD)
Number of starts per hour Maximum 30
Code compliance IEC 60034-1
Voltage variation • Continuously running: Maximum ±5%
• Intermittent running: Maximum ±10%
Voltage imbalance between Maximum 2%
phases
Stator insulation class H (180°C, 356°F)

Cables
Application Type
Direct-on-line start or Y/D start with two cables Flygt SUBCAB® - a heavy duty 4 cores motor power cable
with two twisted pair screened control cores. Conductor
insulation rating of 90°C, which allows for increased
current. Superior mechanical strength and high abrasion
and tear resistant. Chemical resistant within pH 3-10 and
ozone, oil, and flame resistant. Used up to 70°C water
temperature. Cables < 10 mm2 with unscreened control
cores.
Y/D start Flygt SUBCAB® - a heavy duty 7 cores motor power cable
with two twisted pair screened control cores. Conductor
insulation rating of 90°C, which allows for increased
current. Superior mechanical strength and high abrasion
and tear resistant. Chemical resistant within pH 3-10 and
ozone, oil, and flame resistant. Used up to 70°C water
temperature. Cables < 7G6 mm2 with unscreened
control cores.
Variable Frequency drive Screened Flygt SUBCAB® - a heavy duty 4 screened cores
motor power cable with four twisted pair screened control
cores. Conductor insulation rating of 90°C, which allows
for increased current. Superior mechanical strength and
high abrasion and tear resistant. Chemical resistant
within pH 3-10 and ozone, oil, and flame resistant. Used
up to 70°C water temperature.

Monitoring equipment
• Thermal contacts opening temperature 140° C (284° F)
• Leakage sensor in the inspection chamber (FLS 10)

Flygt 3171, 60Hz Technical Specification 15


N-pump, Standard Motor

Materials

Table 11: Major parts except mechanical seals

Denomination Material ASTM EN


Major castings Cast iron, gray 35B GJL-250
Pump housing Cast iron, gray 35B GJL-250
Impeller, alternative 1 Cast iron, gray 35B GJL-250
Impeller, alternative 2 Cast iron, Hard-Iron ™
A 532 IIIA GJN-HB555(XCR23)
Impeller, alternative 3 Stainless steel, Duplex CD-4MCuN 10283:2010 -1.4474
Insert ring, alternative 1 Cast iron, gray 35B GJL-250
Insert ring, alternative 2 Cast iron, Hard-Iron ™
A 532 IIIA GJN-HB555(XCR23)
Cooling jacket, inner Aluminum AA 1050A AW-1050A
Cooling jacket, outer, alternative Steel GR65 S235JRG2
1
Cooling jacket, outer, alternative Stainless steel AISI 316L 1.4404,1.4432, …
2
Lifting handle Stainless steel AISI 316L 1.4404,1.4432, …
Shaft Stainless steel AISI 431 1.4057+QT800
Screws and nuts Stainless steel, A4 AISI 316L, 316, 316Ti 1.4401,1.4404, …
O-rings, alternative 1 Nitrile rubber (NBR) 70° - -
IRH
O-rings, alternative 2 Fluorinated rubber - -
(FPM) 70° IRH
Glycol Heat transfer fluid based - -
on monopropylene
glycol.

Table 12: Mechanical seals

Alternative Inner seal Outer seal


1 Corrosion resistant cemented Corrosion resistant cemented
carbide/ Corrosion resistant carbide/ Corrosion resistant
cemented carbide cemented carbide
2 Corrosion resistant cemented Silicon carbide/ Silicon carbide
carbide/ Corrosion resistant
cemented carbide

Surface treatment
Priming Finish
Painted with a primer, see internal standard Navy gray color NCS 5804-B07G. Two-component high-
M0700.00.0002 solid top coating, see internal standard M0700.00.0004
for standard painting and M0700.00.0008 for special
painting.

Options
• Warm liquid version (non-explosion proof versions)
• Sensors: Thermistor, FLS, PT 100, VIS 10
• Surface treatment (Epoxy)
• Zinc anodes
• Other cables

16 Flygt 3171, 60Hz Technical Specification


N-pump, Standard Motor

Accessories
Discharge connections, adapters, hose connections, and other mechanical accessories.
Electrical accessories such as pump controller, control panels, starters, monitoring relays,
cables.

Motor rating and performance curves 3171.181/.091/.185/.095


These are examples of motor rating and curves. For more information, please contact
your local sales and service representative.
Star-delta starting current is 1/3 of Direct on-line starting current.
LT
P2 [hp] / [kW]

20
25
18
16
20 613
14
614
12
15 615

H [ft] / [m]
50 LT
14

40 12

10
30
8

20 6

4
10
2
615 614 613

0 0
0 50 100 150 200 250 300
0 1000 2000 3000 4000 5000
Q [l/s] / [usgpm]
WS005111B

Table 13: 460 V, 60 Hz, 3–phase

Rated power, Rated power, Curve/ Revolutions Rated Starting Power factor, Installation
kW hp Impeller No per minute, current, A current, A cos φ
rpm
18.6 25 613 1160 31 174 0.86 P,S,T,Z
18.6 25 614 1160 31 174 0.86 P,S,T,Z
18.6 25 615 1160 31 174 0.86 P,S,T,Z

Flygt 3171, 60Hz Technical Specification 17


N-pump, Standard Motor

MT
P2 [hp] / [kW]
40
433
25
434
30
20 435
436
20 15 437

10
10

H [ft] / [m]

120 MT
35

100 30

80 25

20
60 433

15
40
10 434
434
435
20 436
5 437

0 0
0 20 40 60 80 100 120 140 160
0 500 1000 1500 2000 2500
Q [l/s] / [usgpm]
WS005112B

Table 14: 460 V, 60 Hz, 3–phase

Rated power, Rated power, Curve/ Revolutions Rated Starting Power factor, Installation
kW hp Impeller No per minute, current, A current, A cos φ
rpm
18.6 25 435 1755 30 183 0.89 P,S,T,Z
18.6 25 436 1755 30 183 0.89 P,S,T,Z
18.6 25 437 1755 30 183 0.89 P,S,T,Z
22 30 433 1755 36 231 0.87 P,S,T,Z
22 30 434 1755 36 231 0.87 P,S,T,Z
22 30 435 1755 36 231 0.87 P,S,T,Z
22 30 436 1755 36 231 0.87 P,S,T,Z
22 30 437 1755 36 231 0.87 P,S,T,Z
25 34 433 1755 40 256 0.9 P,S,T,Z
25 34 434 1755 40 256 0.9 P,S,T,Z
25 34 435 1755 40 256 0.9 P,S,T,Z
25 34 436 1755 40 256 0.9 P,S,T,Z
25 34 437 1755 40 256 0.9 P,S,T,Z

18 Flygt 3171, 60Hz Technical Specification


N-pump, Standard Motor

HT
P2 [hp] / [kW]

40 30
25
452 453 454
30
20 455

20 15
10
10

H [ft] / [m]

180 HT
160 50

140 452
40
120

100 30 453

80
20
60
454

40 455
10
20

0 0
0 10 20 30 40 50 60 70 80 90
0 200 400 600 800 1000 1200 1400
Q [l/s] / [usgpm]
WS005113B

Table 15: 460 V, 60 Hz, 3–phase

Rated power, Rated power, Curve/ Revolutions Rated Starting Power factor, Installation
kW hp Impeller No per minute, current, A current, A cos φ
rpm
18.6 25 453 1755 30 183 0.89 P,S,T,Z
18.6 25 454 1755 30 183 0.89 P,S,T,Z
18.6 25 455 1755 30 183 0.89 P,S,T,Z
22 30 452 1755 36 231 0.87 P,S,T,Z
22 30 453 1755 36 231 0.87 P,S,T,Z
22 30 454 1755 36 231 0.87 P,S,T,Z
22 30 455 1755 36 231 0.87 P,S,T,Z
25 34 452 1755 40 256 0.9 P,S,T,Z
25 34 453 1755 40 256 0.9 P,S,T,Z
25 34 454 1755 40 256 0.9 P,S,T,Z
25 34 455 1755 40 256 0.9 P,S,T,Z

Flygt 3171, 60Hz Technical Specification 19


N-pump, Standard Motor

SH
P2 [hp] / [kW]

40 30
274
25 275

30
20 277

278
20 15

H [ft] / [m]

300
SH
90
274
80
250
70
200 60

50
150
40
100 30
275
20
277
50 278
10

0 0
0 10 20 30 40 50
0 100 200 300 400 500 600 700 800 900
Q [l/s] / [usgpm]
WS005114B

Table 16: 460 V, 60 Hz, 3–phase

Rated power, Rated power, Curve/ Revolutions Rated Starting Power factor, Installation
kW hp Impeller No per minute, current, A current, A cos φ
rpm
26 35 274 3520 39 273 0.92 P,S,T,Z
26 35 275 3520 39 273 0.92 P,S,T,Z
26 35 277 3520 39 273 0.92 P,S,T,Z
26 35 278 3520 39 273 0.92 P,S,T,Z

Motor rating and performance curves 3171.660/.670


These are examples of motor rating and curves. For more information, please contact
your local sales and service representative.
Star-delta starting current is 1/3 of Direct on-line starting current.

20 Flygt 3171, 60Hz Technical Specification


N-pump, Standard Motor

MT
P2[kW] / [hp]
40
433
25
30 434

20 435
436
20 15 437

10
10

H [m] / [ft]

120 MT
35

100 30

80 25

20
60 433

15
40
10 434
435
436
20 437
5

0 0
0 20 40 60 80 100 120 140 160
0 500 1000 1500 2000 2500
Q [l/s] / [usgpm]
WS007660A

Table 17: 460 V, 60 Hz, 3–phase

Rated power, Rated power, Curve/ Revolutions Rated Start current, Power Factor, Installation
kW hp Impeller No per minute, Current, A A cos φ
rpm
18.6 25 435 1755 30 183 0.89 P,S
18.6 25 436 1755 30 183 0.89 P,S
18.6 25 437 1755 30 183 0.89 P,S
22 30 435 1755 36 230 0.88 P,S
22 30 436 1755 36 230 0.88 P,S
22 30 437 1755 36 230 0.88 P,S
25 34 433 1755 40 259 0.89 P,S
25 34 434 1755 40 259 0.89 P,S
25 34 435 1755 40 259 0.89 P,S
25 34 436 1755 40 259 0.89 P,S
25 34 437 1755 40 259 0.89 P,S

Flygt 3171, 60Hz Technical Specification 21


N-pump, Premium Efficiency Motor (IE3)

N-pump, Premium Efficiency Motor


(IE3)
Product description

Usage
A submersible pump for efficient pumping of clean water, surface water, and wastewater
containing solids or long-fibered material. The pump is designed for sustained high
efficiency. For abrasive media, Hard-Iron™ is required. Stainless steel N-impeller is
available as an option.
Denomination
Type Non-explosion proof Explosion proof Pressure class Installation
version version types
Cast iron 3171.800 3171.810 LT — Low head P, S, T, Z
MT — Medium head
HT — High head
SH — Super head
Hard-Iron™ 3171.820 3171.830 LT — Low head P, S, T, Z
MT — Medium head
HT — High head
SH — Super head
Stainless steel 3171.860 3171.870 MT — Medium head P, S

The pump can be used in the following installations:


P Semi permanent, wet well arrangement with pump installed on two guide bars with
automatic connection to discharge.
S Portable semi permanent, wet well arrangement with hose coupling or flange for
connection to discharge pipeline.
T Vertical permanent, dry well arrangement with flange connection to suction and
discharge piping.
Z Horizontal permanent, dry well arrangement with flange connection to suction and
discharge piping.

22 Flygt 3171, 60Hz Technical Specification


N-pump, Premium Efficiency Motor (IE3)

Application limits
Feature Description
Liquid temperature Maximum 40°C (104°F)
Depth of immersion Maximum 20 m (65 ft)
pH of the pumped liquid 5.5 – 14
Liquid density Maximum 1100 kg/m3

Motor data
Feature Description
Motor type Squirrel-cage induction motor
Frequency 60 Hz
Power supply 3-phase
Starting method • Direct on-line
• Star-delta
• Variable Frequency Drive (VFD)
Number of starts per hour Maximum 30
Code compliance IEC 60034-1
Voltage variation • Continuously running: Maximum ±5%
• Intermittent running: Maximum ±10%
Voltage imbalance between Maximum 2%
phases
Stator insulation class H (180°C, 356°F)

Cables
Application Type
Direct-on-line start or Y/D start with two cables Flygt SUBCAB® - a heavy duty 4 cores motor power cable
with two twisted pair screened control cores. Conductor
insulation rating of 90°C, which allows for increased
current. Superior mechanical strength and high abrasion
and tear resistant. Chemical resistant within pH 3-10 and
ozone, oil, and flame resistant. Used up to 70°C water
temperature. Cables < 10 mm2 with unscreened control
cores.
Y/D start Flygt SUBCAB® - a heavy duty 7 cores motor power cable
with two twisted pair screened control cores. Conductor
insulation rating of 90°C, which allows for increased
current. Superior mechanical strength and high abrasion
and tear resistant. Chemical resistant within pH 3-10 and
ozone, oil, and flame resistant. Used up to 70°C water
temperature. Cables < 7G6 mm2 with unscreened
control cores.
Variable Frequency drive Screened Flygt SUBCAB® - a heavy duty 4 screened cores
motor power cable with four twisted pair screened control
cores. Conductor insulation rating of 90°C, which allows
for increased current. Superior mechanical strength and
high abrasion and tear resistant. Chemical resistant
within pH 3-10 and ozone, oil, and flame resistant. Used
up to 70°C water temperature.

Monitoring equipment
• Thermal contacts opening temperature 140° C (284° F)
• Leakage sensor in the inspection chamber (FLS 10)

Flygt 3171, 60Hz Technical Specification 23


N-pump, Premium Efficiency Motor (IE3)

Materials

Table 18: Major parts except mechanical seals

Denomination Material ASTM EN


Major castings Cast iron, gray 35B GJL-250
Pump housing Cast iron, gray 35B GJL-250
Impeller, alternative 1 Cast iron, gray 35B GJL-250
Impeller, alternative 2 Cast iron, Hard-Iron ™
A 532 IIIA GJN-HB555(XCR23)
Impeller, alternative 3 Stainless steel, Duplex CD-4MCuN 10283:2010 -1.4474
Insert ring, alternative 1 Cast iron, gray 35B GJL-250
Insert ring, alternative 2 Cast iron, Hard-Iron ™
A 532 IIIA GJN-HB555(XCR23)
Cooling jacket, inner Aluminum AA 1050A AW-1050A
Cooling jacket, outer Stainless steel AISI 316L 1.4404,1.4432, …
Lifting handle Stainless steel AISI 316L 1.4404,1.4432, …
Shaft Stainless steel AISI 431 1.4057+QT800
Screws and nuts Stainless steel, A4 AISI 316L, 316, 316Ti 1.4401,1.4404, …
O-rings, alternative 1 Nitrile rubber (NBR) 70° - -
IRH
O-rings, alternative 2 Fluorinated rubber - -
(FPM) 70° IRH
Glycol Heat transfer fluid based - -
on monopropylene
glycol.

Table 19: Mechanical seals

Alternative Inner seal Outer seal


1 Corrosion resistant cemented Corrosion resistant cemented
carbide/ Corrosion resistant carbide/ Corrosion resistant
cemented carbide cemented carbide
2 Corrosion resistant cemented Silicon carbide/ Silicon carbide
carbide/ Corrosion resistant
cemented carbide

Surface treatment
Priming Finish
Painted with a primer, see internal standard Navy gray color NCS 5804-B07G. Two-component high-
M0700.00.0002 solid top coating, see internal standard M0700.00.0004
for standard painting and M0700.00.0008 for special
painting.

Options
• Sensors: Thermistor, FLS, PT 100, VIS 10
• Surface treatment (Epoxy)
• Zinc anodes
• Other cables
Accessories
Discharge connections, adapters, hose connections, and other mechanical accessories.
Electrical accessories such as pump controller, control panels, starters, monitoring relays,
cables.

24 Flygt 3171, 60Hz Technical Specification


N-pump, Premium Efficiency Motor (IE3)

Motor rating and performance curves 3171.800/.810/.820/.830


These are examples of motor rating and curves. For more information, please contact
your local sales and service representative.
Star-delta starting current is 1/3 of Direct on-line starting current.
LT
P2[kW] / [hp]

16
20
14
614
12
15 615
10 616

10 8
617

H [m] / [ft]
45
LT
40 12
35
10
30
8
25

20 6

15
4
10 616
617
2
5 615 614

0 0
0 50 100 150 200 250 300
0 1000 2000 3000 4000 5000
Q [l/s] / [usgpm]

WS004587B

Table 20: 460 V, 60 Hz, 3–phase

Rated power, Rated power, Curve/ Revolutions Rated Start current, Power Factor, Installation
kW hp Impeller No per minute, Current, A A cos φ
rpm
13.4 18 615 1180 21 155 0.86 P,S,T,Z
13.4 18 616 1180 21 155 0.86 P,S,T,Z
13.4 18 617 1180 21 155 0.86 P,S,T,Z
16.4 22 614 1180 28 209 0.79 P,S,T,Z
16.4 22 615 1180 28 209 0.79 P,S,T,Z
16.4 22 616 1180 28 209 0.79 P,S,T,Z
16.4 22 617 1180 28 209 0.79 P,S,T,Z

Flygt 3171, 60Hz Technical Specification 25


N-pump, Premium Efficiency Motor (IE3)

MT
P[hp]
2
/ [kW]
40

35 433
25
434
30
20 435
25
436
20 15 437

15

H [ft] / [m]

120 MT
35

100 30

80 25

20 433
60
15
40
10 434
435
436
20 437
5

0 0
0 20 40 60 80 100 120 140 160
0 500 1000 1500 2000 2500
Q [l/s] / [usgpm]

WS004588A

Table 21: 460 V, 60 Hz, 3–phase

Rated power, Rated power, hp Curve/Impeller Revolutions per Rated current, A Starting current, Power factor, cos Installation
kW No minute, rpm A φ
18.6 25 436 1775 28 218 0.9 P,S,T,Z
18.6 25 437 1775 28 218 0.9 P,S,T,Z
22 30 434 1775 33 251 0.91 P,S,T,Z
22 30 435 1775 33 251 0.91 P,S,T,Z
22 30 436 1775 33 251 0.91 P,S,T,Z
22 30 437 1775 33 251 0.91 P,S,T,Z
25 34 433 1775 38 300 0.89 P,S,T,Z
25 34 434 1775 38 300 0.89 P,S,T,Z
25 34 435 1775 38 300 0.89 P,S,T,Z
25 34 436 1775 38 300 0.89 P,S,T,Z
25 34 437 1775 38 300 0.89 P,S,T,Z

26 Flygt 3171, 60Hz Technical Specification


N-pump, Premium Efficiency Motor (IE3)

HT
P[hp]
2
/ [kW]
50
35
40 30
452 453
25 454
30
20 455

20 15
10
10

H [ft] / [m]

180 HT
160 50

140
40 452
120

100 30
453
80
20
60
454
40 455
10
20

0 0
0 20 40 60 80 100
0 200 400 600 800 10001200140016001800
Q [l/s] / [usgpm]

WS004589A

Table 22: 460 V, 60 Hz, 3–phase

Rated power, Rated power, hp Curve/Impeller Revolutions per Rated current, A Starting current, Power factor, cos Installation
kW No minute, rpm A φ
18.6 25 453 1775 28 218 0.9 P,S,T,Z
18.6 25 454 1775 28 218 0.9 P,S,T,Z
18.6 25 455 1775 28 218 0.9 P,S,T,Z
22 30 452 1775 33 251 0.91 P,S,T,Z
22 30 453 1775 33 251 0.91 P,S,T,Z
22 30 454 1775 33 251 0.91 P,S,T,Z
22 30 455 1775 33 251 0.91 P,S,T,Z
25 34 452 1775 38 300 0.89 P,S,T,Z
25 34 453 1775 38 300 0.89 P,S,T,Z
25 34 454 1775 38 300 0.89 P,S,T,Z
25 34 455 1775 38 300 0.89 P,S,T,Z

Flygt 3171, 60Hz Technical Specification 27


N-pump, Premium Efficiency Motor (IE3)

SH
P[hp]
2
/ [kW]

40 30
274
25 275

30
20 277

278
20 15

H [ft] / [m]

300 SH
90
274
80
250
70
200 60

50
150
40
100 30
275
20 277
50 278
10

0 0
0 10 20 30 40 50
0 100 200 300 400 500 600 700 800 900
Q [l/s] / [usgpm]

WS004590A

Table 23: 460 V, 60 Hz, 3–phase

Rated power, Rated power, hp Curve/Impeller Revolutions per Rated current, A Starting current, Power factor, cos Installation
kW No minute, rpm A φ
26 35 274 3530 38 284 0.93 P,S,T,Z
26 35 275 3530 38 284 0.93 P,S,T,Z
26 35 277 3530 38 284 0.93 P,S,T,Z
26 35 278 3530 38 284 0.93 P,S,T,Z

Motor rating and performance curves 3171.860/.870


These are examples of motor rating and curves. For more information, please contact
your local sales and service representative.
Star-delta starting current is 1/3 of Direct on-line starting current.

28 Flygt 3171, 60Hz Technical Specification


N-pump, Premium Efficiency Motor (IE3)

MT
P2[kW] / [hp]
40
433
25 434
30
20 435
436
20 15 437

10
10

H [m] / [ft]

120 MT
35

100 30

80 25

20 433
60
15
40
10 434
435
436
20 437
5

0 0
0 20 40 60 80 100 120 140 160
0 500 1000 1500 2000 2500
Q [l/s] / [usgpm]
WS007662A

Table 24: 460 V, 60 Hz, 3–phase

Rated power, Rated power, Curve/ Revolutions Rated Start current, Power Factor, Installation
kW hp Impeller No per minute, Current, A A cos φ
rpm
18.6 25 436 1775 28 218 0.9 P,S
18.6 25 437 1775 28 218 0.9 P,S
22 30 435 1775 33 251 0.91 P,S
22 30 436 1775 33 251 0.91 P,S
22 30 437 1775 33 251 0.91 P,S
25 34 433 1775 38 300 0.89 P,S
25 34 434 1775 38 300 0.89 P,S
25 34 435 1775 38 300 0.89 P,S
25 34 436 1775 38 300 0.89 P,S
25 34 437 1775 38 300 0.89 P,S

Flygt 3171, 60Hz Technical Specification 29


Dimensions and Weight, Standard Motor

Dimensions and Weight, Standard


Motor
Drawings
All drawings are available as Acrobat documents (.pdf) and AutoCad drawings (.dwg).
Contact your local sales and service representative for more information.
All dimensions are in mm.

Figure 1: LT, P-installation Figure 2: LT, S-installation

30 Flygt 3171, 60Hz Technical Specification


Dimensions and Weight, Standard Motor

Figure 3: LT, S-installation Figure 4: LT, T-installation

Figure 5: LT, Z-installation Figure 6: LT, Z-installation

Flygt 3171, 60Hz Technical Specification 31


Dimensions and Weight, Standard Motor

Figure 7: MT, P-installation Figure 8: MT, P-installation

Figure 9: MT, S-installation Figure 10: MT, S-installation

32 Flygt 3171, 60Hz Technical Specification


Dimensions and Weight, Standard Motor

Figure 11: MT, T-installation Figure 12: MT, Z-installation

Figure 13: MT, Z-installation Figure 14: HT, P-installation

Flygt 3171, 60Hz Technical Specification 33


Dimensions and Weight, Standard Motor

Figure 15: HT, S-installation Figure 16: HT, T-installation

Figure 17: HT, Z-installation Figure 18: HT, Z-installation

34 Flygt 3171, 60Hz Technical Specification


Dimensions and Weight, Standard Motor

Figure 19: SH, P-installation Figure 20: SH, S-installation

Figure 21: SH, T-installation Figure 22: SH, T-installation

Flygt 3171, 60Hz Technical Specification 35


Dimensions and Weight, Standard Motor

Figure 23: SH, Z-installation Figure 24: SH, Z-installation

36 Flygt 3171, 60Hz Technical Specification


Dimensions and Weight, Premium Efficiency Motor (IE3)

Dimensions and Weight, Premium


Efficiency Motor (IE3)
Drawings
All drawings are available as Acrobat documents (.pdf) and AutoCad drawings (.dwg).
Contact your local sales and service representative for more information.
All dimensions are in mm.

Figure 25: LT, P-installation Figure 26: LT, S-installation

Flygt 3171, 60Hz Technical Specification 37


Dimensions and Weight, Premium Efficiency Motor (IE3)

Figure 27: LT, T-installation Figure 28: LT, Z-installation

Figure 29: LT, Z-installation Figure 30: MT, P-installation

38 Flygt 3171, 60Hz Technical Specification


Dimensions and Weight, Premium Efficiency Motor (IE3)

Figure 31: MT, P-installation Figure 32: MT, S-installation

Figure 33: MT, S-installation Figure 34: MT, T-installation

Flygt 3171, 60Hz Technical Specification 39


Dimensions and Weight, Premium Efficiency Motor (IE3)

Figure 35: MT, Z-installation Figure 36: MT, Z-installation

Figure 37: HT, P-installation Figure 38: HT, S-installation

40 Flygt 3171, 60Hz Technical Specification


Dimensions and Weight, Premium Efficiency Motor (IE3)

Figure 39: HT, T-installation Figure 40: HT, Z-installation

Figure 41: HT, Z-installation Figure 42: SH, P-installation

Flygt 3171, 60Hz Technical Specification 41


Dimensions and Weight, Premium Efficiency Motor (IE3)

Figure 43: SH, S-installation Figure 44: SH, T-installation

Figure 45: SH, T-installation Figure 46: SH, Z-installation

42 Flygt 3171, 60Hz Technical Specification


Dimensions and Weight, Premium Efficiency Motor (IE3)

Figure 47: SH, Z-installation

Flygt 3171, 60Hz Technical Specification 43


Xylem |’zīləm|
1) The tissue in plants that brings water upward from the roots
2) A leading global water technology company

We're 12,500 people unified in a common purpose: creating innovative


solutions to meet our world's water needs. Developing new technologies that
will improve the way water is used, conserved, and re-used in the future is central
to our work. We move, treat, analyze, and return water to the environment, and
we help people use water efficiently, in their homes, buildings, factories and
farms. In more than 150 countries, we have strong, long-standing relationships
with customers who know us for our powerful combination of leading product
brands and applications expertise, backed by a legacy of innovation.

For more information on how Xylem can help you, go to xyleminc.com

Refer to www.xylemwatersolutions.com/contacts/ for contact details of your local sales and service
representative.

Xylem Water Solutions Global Visit our Web site for the latest version of this document
and more information
Services AB
361 80 Emmaboda The original instruction is in English. All non-English
instructions are translations of the original instruction.
Sweden
Tel: +46-471-24 70 00 © 2012 Xylem Inc

Fax: +46-471-24 47 01
http://tpi.xyleminc.com

883467_5.0_en-US_2015-01_TS_3171_60Hz

Вам также может понравиться