4S0W power supply Adjustable Current limit 12V 24V 36V 4SV 60V

input voltage:110V/220V
SOV 120V 220V DC
output voltage: 0-24VO-20A
Condition New
0-36VO-15A
Output 0-22DV G-2.2A
0-48VO-10A
power 0-480W 0-60VO-8A Quantity ~ 2 available
11 sold I See feedback
0-80VO-6A
Size:215*115*50mlJ)_~ .... 0-120VO-4A Price US $58.50
..:~~ 0-220VO-2.2A Buy It Now
-
-. Add to cart

I Add to watchlis! R
100% buyer satisfaction No returns 12 watchers

Ill".J/
O.56'digital dispaly show
Shipping $15.00 Standard Shipping from China/Hong KongfTaiwan to worldwide I
See deta,ls
See details about intematiooaJ shiJlPing here . .
voltage and current Item locatioo M. China
Ships to WoMw;de

Delivery g Estimated between Mon. Sep. 9 and Wed. Oct. 2 ..


voltage and current adjustable Please note the delivery estimate is greater than 8 business days.

PayPaI CREDIT
I• • • "" Spec~1 ~nancing avaitable ApoW Now I See terms

Returns Seller does not accept returns I See details


Lr480W digital display switching power supply Adjustable voltage Current limit 0-24V 36V 48V 60v 80V 120v nOv, 24v 20A, 48V lOa
To ensure the lifetime of the power supply. pis don't use full load when you use it. We recommend the use power should be 80% of tIle rated power.For
example: the label of tIle power supply is 500W. use power should be: 500W·80% 100W

Specifictation:
Input voltage: 11 0/220vac selected by switch
Output power limiting output voltage range limiting output current range Max current
480W 0-24V 0-20A 20A
480W 0-36V 0-15A 15A
480W 0-48V 0-10A lOA
480W 0-60V 0-8A 8A
480W 0-80V 0-6A 6A
480W 0-120V 0-4A 4A
480W o-nov 0-2.2A 2.2A
@The lower left corner of the pull-switch to
the right to the "open (use)" stalls -
@the (special adjustable current plug) removed,
insert the original insert card holder,
remove the rear display shows the voltage O.90V or so,
the current O.OOA
@Turn on the power,
and then the right knob can be adjusted to
you want to limit current parameters,
digital display of synchronous current parameters,
0-20A adiu ou hou,,-_
-
limit current (adjust the current)

(!)the (special adjustable curren plug)


pulled out to the terminal port and 3 ports.
with a screwdriver to loosen the port screw,
(!)Switch left Toggle
then use a screwdriver to tighten.
-- -
_ ..--.....
u ...
-
adjust voltage,. . adj st current
~_ _~l;;
S 411H1 Ii

.. ,..,
_.......
,.. ".#f' ./" . ~
adjust current
plugboard gift: 9 pcs terminal
Tenninal description and wiring method

L N AC input temlinal FG ground mark V+ DC output positive tenninal


V-DC output negative tenninal ADJ adjustable potentiometer Fine-tuning output DC voltage
e full ,'oltage input
e Miniaturization
eProtection function Short circuit! overload / over voltage
elOO% full load aging test
Input Voltage & Frequency Range----------II OV!220VAC!4 7"-'63Hz
Stan surge current ---------------20A@120VAC (cold start)
Output adjustment range --------------- ± 100% (rated output voltage)
Overload protection -------------------105%-200% (rated load), self-recovery
Oven'oltage protection -------------------115%~135% (rated output voltage)
Short circuit protection ------------------- self-recovery
Output start time ---------------::;2S@120VAC ::;1.0S@230VAC
Output hold lime ---------------?: 1OmS@120VAC, ?:20mS@230VAC
Insulation strength ------------------- Input - Output: AC1500V, Imin
Input - housing: AC1500V, 1min
Output - Case: DC500V, lmin
Working enviromnent ------------------ -10 0 C ~ 50 0 C: 20% - 90% RH (no condensation)
Operational use
(How to limit clUTent) 10 adjust current?
I. Operate in the case of power failure, pun the small pull switch in the lower left comer to the ClUTent regulating gear
2. Pull out (dedicated ClUTent regulating insert) to the 2nd and 3rd ports ofthe wiring port, loosen the port screw with a screwdriver, and tighten with a screwdriver (at this
time, COIlllect to the listed power), and then connect The \·oltage ofthe meter shows O.OOV, and the ClUTent shows the ClUTent current parameter. At this time, the power
supply will emit a small current.
3. On the right side (adjust current knob), you can adjust the desired current limit parameter, and display the clUTent parameter synchronously with the digital display.
0-21A10-16A10-11AlO-6.5A can be adjusted in the whole process.
4. Remo\'e the (special adjustment clUTent plug) and insert it back into the original insert card holder. After removing the digital display, the voltage is about O.90V, and the
ClUTent is O.OOA.
5. Pull the pull switch in the lower left comer to the right to open the "open (use)" position.
6. The ClUTent power supply is in the parameter value of the current limit. The power supply is adjusted to a few V (the digital display shows the output \·oltage in real
time), the current does not change, and the current reaches the current limit of95% of the current limiting parameter. Overload protection
7. The ClUTent parameter displayed by the digital display at this time is the current value of the device load, and the load current is monitored in real time.

When the load device is connected, the current value can be adjusted directly in real time. The maximwn current value is the maximum current \'alue of the load device. If
the current adjusunent knob clockwise exceeds the maximum current value of the device, the digital current value will not last. Real-time synchronized digital display,
showing only the maximum ClUTent value of the de\'ice.

If there is no need for current limiting, use the general equipment, without the above operation, pull the pull switch in the lower left comer to the "open (use)" position, and
tum the (current adjustment knob) clockwise to the top. The maximum CWTent limit at this time is 21A116A111A16.5A14A, at this time the power supply parameter is the
output 0-24V21A10-16A10-48VIIAJO-36V15A10-80V6.5A10-120V4A, which is equal to a 0-24V20A IO-36VI5A10-48VIOAJO-80V6A10-120V4A switching power supply

Uses: Mainly used for various battery charging, DC equipment, DC motor stepless speed regulation, LED stepless dinuning, chemical e1ectrmplating speed regulation,
scientific research test, student experiment, etc., and a wide range of uses.
Special attention: If using inductive load such as motor or fan, please pay attention 10 the maximwn starting current parameter of the motor. This parameter must not be
higher than the maximum operating current of the power supply. Otherwise, the power supply may be damaged. You should select a higher current power supply or soften
the motor. The protection circuit is activated to absorb the inrush ClUTent.
Power fOlllmla) \·oltage X current = power
@The current power supply is just in the current limit of the parameter value,
regardless of the power supply to a few V
(digital display real-time display output voltage).
the current constant,
the use of current reaches 95% of the current limit parameters began to buck
Overload protection

-ffilhen the dipitilU!i>.J>Iil.\£..OhQw


the current parameter is the current value of the device load.
real-time monitorin.g_of load current
~ote thn ~he power supply on the righJ side Qf!he power
(adjust the current knob) do not go to spin.
...idt.er the rotation o~currenLlilllitin.g arameters w·

Вам также может понравиться