Вы находитесь на странице: 1из 4

Set 2A

RADIOGRAPHIC INTERPRETATION – REPORT

Radiographic Identification: - D7 PL 30

Inspector: - _______________________________

Date: - ______________ Course: ________

Material: Carbon Steel Plate Thickness: 12 mm

Weld Thickness: 15 mm

Welding Process: MMA Edge Preparation: Single V

KV/ Source: Ir 192 Screens: Pb

Film Type: D7 (AGFA) FFD/SFD: _____________

Type of IQI used: _______________________ Technique: SWSI

Number of wire visible: ____________________________________________________

Film Density: a) Weld Zone _______________________________________


b) Parent Plate _______________________________________

________________________________________________________________________

Report
1. Calculate the sensitivity level for this radiograph?

2. Calculate the geometric unsharpness (Ug) based on the parameters given?

3. Comments on Radiographic Quality

a. Sensitivity: ________________ b. Density: ________________

c. Technique: __________________________________________________
RADIOGRPHIC REPORT (Set 2A)

1. SINGLE WALL SINGLE IMAGE (SWSI)

0 150

1 2

List of defects: 1. Lack of root penetration (+ 65 from datum, 14 mm)


2. Gas pore (+ 82 mm from datum, 1mm long)

150 300

3
List of defects:

3. Lack of sidewall fusion (+299 from datum, 19 mm long)

Set 2B
RADIOGRAPHIC INTERPRETATION – REPORT

Radiographic Identification: - A-B-C-D

Inspector: - _______________________________

Date: - ______________ Course: ________

Material: Carbon Steel Plate Thickness: 16 mm

Weld Thickness: 19 mm

Welding Process: MMA Edge Preparation: Single V

KV/ Source: 140Kv / 1.5 mm X 1.5 mm Screens: Pb

Film Type: D7 (AGFA) FFD/SFD: 750 mm

Type of IQI used: _______________________ Technique:SWSI

Number of wire visible: ____________________________________________________

Film Density: a) Weld Zone _______________________________________


b) Parent Plate _______________________________________

________________________________________________________________________

Report
1.Calculate the sensitivity level for this radiograph?

2. Calculate the geometric unsharpness (Ug) based on the parameters given?

3. Comments on Radiographic Quality

a. Sensitivity: ________________ b. Density: ________________

c. Technique: __________________________________________________
RADIOGRPHIC REPORT (Set 2B)

1. SINGLE WALL SINGLE IMAGE (SWSI)

0 150

1 1

List of defects:
1. Lack of root penetration (+85mm from datum, 4mm long)
(+ 200mm from datum, 179 mm long)

2. Scattered porosity (+137 mm from datum, throughout the length)

150 300
3
2
5 4

1
List of defects:
3. External Undercut (+305 from datum, 27mm long) 3
(+344 from datum, 12mm long)

4. Under fill (+356 from datum, edge of the weld)

5. Cluster porosity (+291 from datum, 15mm long)