SECOND FLOOR
BEAM LENGTH TYPE
DESIGNATION
EXTERIOR BEAM
B1 4000 BOTH-END CONTINUOUS
B2 4000 ONE-END CONTINUOUS
G1 7000 ONE-END CONTINUOUS
G2 7000 BOTH-END CONTINUOUS
G3 7000 BOTH-END CONTINUOUS
G4 7000 BOTH-END CONTINUOUS
G5 7000 BOTH-END CONTINUOUS
G6 7000 BOTH-END CONTINUOUS
G7 7000 ONE-END CONTINUOUS
G8 7000 BOTH-END CONTINUOUS
G9 7000 BOTH-END CONTINUOUS
INTERIOR BEAM
B3 7000 ONE-END CONTINUOUS
B4 7000 BOTH-END CONTINUOUS
B5 7000 BOTH-END CONTINUOUS
B6 7000 BOTH-END CONTINUOUS
B7 7000 BOTH-END CONTINUOUS
B8 7000 BOTH-END CONTINUOUS
B9 4000 BOTH-END CONTINUOUS
B10 4000 ONE-END CONTINUOUS
B11 7000 BOTH-END CONTINUOUS
B12 4000 BOTH-END CONTINUOUS
B13 7000 ONE-END CONTINUOUS
B14 7000 BOTH-END CONTINUOUS
B15 7000 BOTH-END CONTINUOUS
B16 7000 BOTH-END CONTINUOUS
B17 7000 BOTH-END CONTINUOUS
B18 7000 BOTH-END CONTINUOUS
B19 7000 BOTH-END CONTINUOUS
B20 7000 BOTH-END CONTINUOUS
B21 7000 ONE-END CONTINUOUS
B22 7000 BOTH-END CONTINUOUS
B23 7000 BOTH-END CONTINUOUS
SIZES PRELIMINARY B
ROOF D
BEAM
HEIGHT BASE LENGTH
DESIGNATION
EXTERIOR B
300 200 B1 4000
300 200 B2 4000
500 350 G1 7000
450 300 G2 7000
450 300 G3 7000
450 300 G4 7000
450 300 G5 7000
450 300 G6 7000
500 350 G7 7000
450 300 G8 7000
450 300 G9 7000
INTERIOR B
500 350 B3 7000
450 300 B4 7000
450 300 B5 7000
450 300 B6 7000
450 300 B7 7000
450 300 B8 7000
300 200 B9 4000
300 200 B10 4000
450 300 B11 7000
300 200 B12 4000
500 350 B13 7000
450 300 B14 7000
450 300 B15 7000
450 300 B16 7000
450 300 B17 7000
450 300 B18 7000
450 300 B19 7000
450 300 B20 7000
500 350 B21 7000
450 300 B22 7000
450 300 B23 7000
PRELIMINARY BEAM SIZES
ROOF DECK
TYPE HEIGHT BASE
EXTERIOR BEAM
BOTH-END CONTINUOUS 300 200
ONE-END CONTINUOUS 300 200
ONE-END CONTINUOUS 500 350
BOTH-END CONTINUOUS 450 300
BOTH-END CONTINUOUS 450 300
BOTH-END CONTINUOUS 450 300
BOTH-END CONTINUOUS 450 300
BOTH-END CONTINUOUS 450 300
ONE-END CONTINUOUS 500 350
BOTH-END CONTINUOUS 450 300
BOTH-END CONTINUOUS 450 300
INTERIOR BEAM
ONE-END CONTINUOUS 500 350
BOTH-END CONTINUOUS 450 300
BOTH-END CONTINUOUS 450 300
BOTH-END CONTINUOUS 450 300
BOTH-END CONTINUOUS 450 300
BOTH-END CONTINUOUS 450 300
BOTH-END CONTINUOUS 300 200
ONE-END CONTINUOUS 300 200
BOTH-END CONTINUOUS 450 300
BOTH-END CONTINUOUS 300 200
ONE-END CONTINUOUS 500 350
BOTH-END CONTINUOUS 450 300
BOTH-END CONTINUOUS 450 300
BOTH-END CONTINUOUS 450 300
BOTH-END CONTINUOUS 450 300
BOTH-END CONTINUOUS 450 300
BOTH-END CONTINUOUS 450 300
BOTH-END CONTINUOUS 450 300
ONE-END CONTINUOUS 500 350
BOTH-END CONTINUOUS 450 300
BOTH-END CONTINUOUS 450 300
PRELIMINARY COLUMN SIZES
GROUND FLOOR TO SECOND FLOOR
COLUMN TYPE HEIGHT
DEISGNATION
C1 EXTERIOR 4600
C2 EXTERIOR 4600
C3 EXTERIOR 4600
C4 EXTERIOR 4600
C5 EXTERIOR 4600
C6 EXTERIOR 4600
C7 EXTERIOR 4600
C8 EXTERIOR 4600
C9 EXTERIOR 4600
C10 EXTERIOR 4600
C11 INTERIOR 4600
C12 INTERIOR 4600
C13 INTERIOR 4600
C14 INTERIOR 4600
C15 INTERIOR 4600
C16 INTERIOR 4600
C17 INTERIOR 4600
C18 EXTERIOR 4600
C19 EXTERIOR 4600
C20 INTERIOR 4600
C21 INTERIOR 4600
C22 EXTERIOR 4600
UMN SIZES PRELIMINARY COLUMN SIZES
COND FLOOR SECOND FLOOR TO ROOF DECK
COLUMN
BASE DEPTH TYPE HEIGHT
DEISGNATION
B1
B2
G1
G2
G3
G4
G5
G6
G7
G8
G9
BEAM DESIGNATION
B3
B4
B5
B6
B7
B8
B9
B10
B11
B12
* B13
B14
B15
B16
B17
B18
* B19
B20
* B21
B22
B23
PRELIMINARY SIZE O
EXTER
INTER
MM
ONE-END CONTINUOUS 7000 25 10 60
BOTH-END CONTINUOUS 7000 25 10 60
BOTH-END CONTINUOUS 7000 25 10 60
BOTH-END CONTINUOUS 7000 25 10 60
BOTH-END CONTINUOUS 7000 25 10 60
BOTH-END CONTINUOUS 7000 25 10 60
BOTH-END CONTINUOUS 4000 25 10 60
ONE-END CONTINUOUS 4000 25 10 60
BOTH-END CONTINUOUS 7000 25 10 60
BOTH-END CONTINUOUS 4000 25 10 60
ONE-END CONTINUOUS 7000 25 10 60
BOTH-END CONTINUOUS 7000 25 10 60
BOTH-END CONTINUOUS 7000 25 10 60
BOTH-END CONTINUOUS 7000 25 10 60
BOTH-END CONTINUOUS 7000 25 10 60
BOTH-END CONTINUOUS 7000 25 10 60
BOTH-END CONTINUOUS 7000 25 10 60
BOTH-END CONTINUOUS 7000 25 10 60
ONE-END CONTINUOUS 7000 25 10 60
BOTH-END CONTINUOUS 7000 25 10 60
BOTH-END CONTINUOUS 7000 25 10 60
PRELIMINARY SIZE OF BEAM 2ND-ROOFDECK
EXTERIOR BEAM
THEORETICAL
BEAM THICKNESS BEA,M HEIGHT BEAM WIDTH EFFECTIOVE DEPTH BEAM HEIGHT
216.22 291.22 145.61 208.72 291.22
216.22 291.22 145.61 208.72 291.22
378.38 453.38 226.69 370.88 453.38
333.33 408.33 204.17 325.83 408.33
333.33 408.33 204.17 325.83 408.33
333.33 408.33 204.17 325.83 408.33
333.33 408.33 204.17 325.83 408.33
333.33 408.33 204.17 325.83 408.33
378.38 453.38 226.69 370.88 453.38
333.33 408.33 204.17 325.83 408.33
333.33 408.33 204.17 325.83 408.33
GOVERNS
INTERIOR BEAMS
THEORETICAL
BEAM THICKNESS BEA,M HEIGHT BEAM WIDTH EFFECTIOVE DEPTH BEAM HEIGHT
MM
378.38 453.38 226.69 370.88 453.38
333.33 408.33 204.17 325.83 408.33
333.33 408.33 204.17 325.83 408.33
333.33 408.33 204.17 325.83 408.33
333.33 408.33 204.17 325.83 408.33
333.33 408.33 204.17 325.83 408.33
190.48 265.48 132.74 182.98 265.48
216.22 291.22 145.61 208.72 291.22
333.33 408.33 204.17 325.83 408.33
190.48 265.48 132.74 182.98 265.48
378.38 453.38 226.69 370.88 453.38
333.33 408.33 204.17 325.83 408.33
333.33 408.33 204.17 325.83 408.33
333.33 408.33 204.17 325.83 408.33
333.33 408.33 204.17 325.83 408.33
333.33 408.33 204.17 325.83 408.33
333.33 408.33 204.17 325.83 408.33
333.33 408.33 204.17 325.83 408.33
378.38 453.38 226.69 370.88 453.38
333.33 408.33 204.17 325.83 408.33
333.33 408.33 204.17 325.83 408.33
GOVERNS
ACTUAL
SAY BEAM WIDTH SAY EFFECTIOVE DEPTH
300 145.61 150 210
300 145.61 150 210
500 226.69 250 380
450 204.17 250 330
450 204.17 250 330
450 204.17 250 330
450 204.17 250 330
450 204.17 250 330
500 226.69 250 380
450 204.17 250 330
450 204.17 250 330
500 250
ACTUAL
SAY BEAM WIDTH SAY EFFECTIOVE DEPTH
500 250
PRELIMINARY BEAM S
SECOND FLOOR
EXTERIOR BEAMS
B1 4000
B2 4000
G1 7000
G2 7000
ONE-END G3 7000
CONTINUO G4 7000
US
BOTH-END CONTINUOUS G5 7000
SIMPLY SUPPORTED G6 7000
CANTILEVER G7 7000
G8 7000
G9 7000
INTERIOR BEAMS
B3 7000
B4 7000
B5 7000
B6 7000
B7 7000
B8 7000
B9 4000
B10 4000
B11 7000
B12 4000
B13 7000
B14 7000
B15 7000
B16 7000
B17 7000
B18 7000
B19 7000
B20 7000
B21 7000
B22 7000
B23 7000
MINARY BEAM SIZE PRELIMINARY BEAM SIZE
SECOND FLOOR ROOF DECK
Height Base
300 200
300 200
500 350
450 300
450 300
450 300
450 300
450 300
500 350
450 300
450 300
Height Base
500 350
450 300
450 300
450 300
450 300
450 300
300 200
300 200
450 300
300 200
500 350
450 300
450 300
450 300
450 300
450 300
450 300
450 300
500 350
450 300
450 300
TRIBUTARY
Type (DL) (LL) h SLAB CONCRETE fy f'c ᴓb
AREA
Column
C1 EXT 5.04 2.4 12.25 0.16 23.56 414 27.6 25
C2 EXT 4.98 4.8 24.50 0.16 23.56 414 27.6 25
C3 EXT 5.36 4.8 24.50 0.16 23.56 414 27.6 25
C4 EXT 5.36 4.8 24.50 0.16 23.56 414 27.6 25
C5 EXT 5.36 4.8 24.50 0.16 23.56 414 27.6 25
C6 EXT 5.36 4.8 24.50 0.16 23.56 414 27.6 25
C7 EXT 5.36 4.8 19.25 0.16 23.56 414 27.6 25
C8 EXT 5.36 4.8 14.00 0.16 23.56 414 27.6 25
C9 EXT 5.36 4.8 7.00 0.16 23.56 414 27.6 25
C10 EXT 4.88 2.4 24.50 0.16 23.56 414 27.6 25
C11 INT. 4.37 3.8 36.75 0.16 23.56 414 27.6 25
C12 INT. 4.37 4.8 24.50 0.16 23.56 414 27.6 25
C13 INT. 4.37 4.8 24.50 0.16 23.56 414 27.6 25
C14 INT. 4.37 4.8 24.50 0.16 23.56 414 27.6 25
C15 INT. 4.37 4.8 24.50 0.16 23.56 414 27.6 25
C16 INT. 4.37 4.8 19.25 0.16 23.56 414 27.6 25
C17 INT. 4.37 3.8 21.00 0.16 23.56 414 27.6 25
C18 EXT. 4.88 3.8 14.00 0.16 23.56 414 27.6 25
C19 EXT. 5.36 4.8 24.50 0.16 23.56 414 27.6 25
C20 INT. 4.37 3.8 24.50 0.16 23.56 414 27.6 25
C21 INT. 4.37 3.8 14.00 0.16 23.56 414 27.6 25
C22 EXT 4.88 3.8 14.00 0.16 23.56 414 27.6 25
STEEL TYPE OF AXIAL DEAD
Ab (ᴓs) TOTAL LL Total LL Pu NO. OF BARS
STEEL
(n) AREA (As)
RATIO (ᴘ) STIRRUPS LOAD
USE THICKNESS
SLAB OUTPUT
USE THICKNESS 160
PRELIMINARY SLAB THICKNESS
2ND FLOOR
USE t BEAM L b h bw bh be Ῡ
SLAB OUTPUT
USE THICKNESS
PRELIMINARY SLAB THICKNESS
ROOF DECK
ASSUMPTION SLAB
fy α fm THICKNESS TYPE OF SLAB USE t BEAM L b
bf(αfm>2.0)
G7 7000 250
B21 7000 250
414 4.675 140 TWO-WAY SLAB 140
B2 4000 150
B10 4000 150
G8 7000 250
B22 7000 250
414 3.395 140 TWO-WAY SLAB 140
B10 4000 150
B12 4000 150
B21 7000 250
B20 7000 250
414 3.975 140 TWO-WAY SLAB 140
B1 4000 150
B9 4000 150
B20 7000 250
B19 7000 250
414 3.73 160 TWO-WAY SLAB 160
G6 7000 250
B8 7000 250
B16 7000 250
B13 7000 250
414 4.14 160 TWO-WAY SLAB 160
G2 7000 250
B4 7000 250
B13 7000 250
G7 7000 250
414 5.3 160 TWO-WAY SLAB 160
G1 7000 250
B3 7000 250
B14 7000 250
G8 7000 250
414 4.14 160 TWO-WAY SLAB 160
B3 7000 250
B11 7000 250
USE THICKNESS 160
LAB OUTPUT
HICKNESS 160
HICKNESS
h bw bh be Ῡ Ibx10^6 L2 Isx10^6 α
live load
LIVE LOAD SUMMARY OF DEAD LOADS
Movable Seat 4.8 KPA GROUND FLOOR
Office 2.4 KPA Concret Slab
Lobbies 4.8 KPA SECOND FLOOR
storage light 6 KPA ROOF DECK
storage acces.audio 2.4 KPA
stairways 4.8 KPA
RestRoom 2.4 KPA
exit facilities 4.8 KPA SUMMARY OF LIVE LOADS
lobbies and Flatforms 4.8 KPA GROUND FLOOR
corridors above gf 3.8 KPA Concret Slab
basic floor area 1.9 KPA SECOND FLOOR
ROOF DECK
RY OF DEAD LOADS DEAD LOAD ( LINEAR/ WALL; NSCP
ROUND FLOOR Concrete Masonry Unit (100 mm Full Grout 2.84 KPA
23.6 KPA Concrete Masonry Unit (150mm Full Grout 2.97 KPA
ECOND FLOOR Plaster (25 mm) 0.24 KPA
ROOF DECK Windows, glass, frame and sash 0.38 KPA
LOAD SLAB) RD
SLAB 4 SLAB 5 SLAB 6 SLAB 7
4.8 4.8 - -
- - - -
- - - -
- - - -
- - - -
- - - -
- - - -
- - - -
- - - -
- - - -
- - 1.9 1.9
CEILING
Gypsum Board 0.008 KPA a
Suspended Lath and plaster 0.48 KPA b
Mechanical Duct Allowance 0.2 KPA
Floor
Concrete Fill 0.023 KPA d
Solid Flat Tile 1.1 KPA
Marble and mortar stone concrete fill 1.58 KPA
LIVE LOAD
S1 4.8 5.537
3.776 1.761
S2 3.8 4.957
3.776 1.181
S3 4.8 4.957
3.776 1.181
S4 4.8 5.437
3.776 1.661
S5 4.8 5.437
3.776 1.661
S6 2.4 5.537
3.776 1.761
S7 1.9 5.637
3.776 1.861
4 1.661
5 1.661
2 1.181
7 1.861
1,6 1.761
3 1.181
ROOF DECK
DEAD LOAD
SECTION LIVE LOAD
Dead load per
Slab self weight slab TOTAL LOAD
S1 4.8 3.849
3.776 0.073
S2 1.9 3.849
3.776 0.073
S3 4.8 3.849
3.776 0.073
S4 4.8 3.849
3.776 0.073
S5 4.8 3.849
3.776 0.073
S6 1.9 3.849
3.776 0.073
S7 1.9 3.849
3.776 0.073
SLAB 1 SLAB 2 SLAB 3 SLAB 4 SLAB 5
gypsum board gypsum board gypsum board gypsum board gypsum board
mech duct water proofing water proofing water proofing water proofing
water proofing concrete fill concrete fill concrete fill concrete fill
concrete fill solid flat tile solid flat tile marble and mortar ston
marble and mortar ston
solid flat tile
150 mm CHB 150 mm CHB 150 mm CHB 150 mm CHB 150 mm CHB
100 mm CHB 100 mm CHB 100 mm CHB 100 mm CHB 100 mm CHB
windows, glass, etc. windows, glass, etc.windows, glass, etc.windows, glass, etc.
SLAB 6 SLAB 7
gypsum board gypsum board
mech duct mech duct
water proofing water proofing
concrete fill concrete fill
solid flat tile marble and mortar stone concrete fill
ROOF DECK
SECTION TYPE OF SLAB �/� WL WD Wu
ln (m) ls (m)
S1 6750 3850 TWO-WAY SLAB 0.57 4.8 3.849 8.649
13265.82
11238.15
12521.48
23033.25
23033.25
17858.25
16958.25
MMARY
CK
WEST
11099.55
7377.88
11099.55
19460.25
19460.25
12935.25
12935.25