126. Closet bends or stubs shall be cut off so as to present 135. Water closets set side by side shall be no closer than 143. Wall-mounted water closets shall be securely bolted to
smooth surface, even with the ______. _____. ____.
A. top of the closet ring A. 30” center to center A. A carrier fitting
B. top of the rough floor B. 15” center to center B. The wall
C. top of the finish floor C. 18” center to center C. Double two by six studs
D. bottom of the closet ring D. 24” center to center D. Closet bend
127. Tanks flushing more than one urinals shall be 136. The minimum distance from a side wall or partition to 144. It is the vertical distance from an inlet to the finished
_______. the center of a urinal shall be ______. floor line of a typical water closet flush tank.
A. Automatic in operation A. 12” A. 152 mm
B. Continual in operation B. 6” B. 102 mm
C. manual in operation C. 24” C. 125 mm
D. acid-resistant enamel D. 18” D. 161 mm
128. Every water supply to a urinal shall be protected by an 137. No manually controlled flushometer valves shall be 145. When installing _____, the Authority Having
approved ______. used to flush more than ______. Jurisdiction shall require evidence of the competency of the
A. Vacuum breaker A. One urinal installers.
B. Relief valve B. Two urinals A. Fuel gas piping
C. metering valve C. Three urinals B. Potable water piping
D. Automatic switch D. Four urinals C. Medical gas piping
D. Plumbing appurtenance
129. Trough urinals shall be _____. 138. Automatically controlled flushometer valves may be
A. prohibited substituted for automatic _____. 146. When brazing the alloys shall have a melting
B. Permissible if constructed of concrete A. Flush tanks temperature of at least ______ degrees F.
C. required in large associations B. flow control A. 1,000
D. allowed in bus stations C. Gate valves B. 840
D. lever valves C. 800
130. It is the clear vertical distance between the spout of a D. 1200
faucet or other outlet of a supply pipe and the flood level of 139. Gutters in public shower rooms shall be sloped not
a receptacle. less than _____. 147. Drain pipes subject to condensation over food storage
A. air gap A. 2 percent in food-handling establishments shall be _____.
B. airbreak B. 5 percent A. Rerouted out of the area
C. flooded level C. 3 percent B. Installed with a spill pan
D. faucet line D. 10 percent C. Thermally insulated
D. Tested with 5 psi of air
131. With two noted exceptions, all shower compartments 140. No dry or chemical closet (toilet) shall be installed in
and receptors shall be capable of encompassing a _____ any building used for human habitation unless first 148. It should be installed so that they provide access to the
diameter circle. approved by the ____. cover and a means for servicing and maintaining the trap.
A. 30” A. Health officer A. Grease trap
B. 24” B. Owner B. Trap primer
C. 33” C. Plumbing inspector C. Grease interceptor
D. 36” D. City clerk D. P-trap
132. The curb or threshold of a shower compartment may 141. Joints at the roof, around pipes, shall be made 149. Screws or bolts for securing floor mounted fixtures
be eliminated _____. watertight by the use of ____. shall be ____.
A. to comply with accessibility standards A. Flashing material A. Brass
B. for gang showers B. Sealing compound B. Aluminum
C. in hospitals only C. 15 lb felt C. Galvanized steel
D. not permitted D. Calcium D. Die cast zinc
133. Shower pan linings may be constructed with _____. 142. 150. Fixtures having concealed slip joint connections shall
A. 15 lbs asphalt felt The minimum wall thickness for threaded plastic be provided with ____.
B. 26 B & S gauge copper pipe shall be ____. A. A utility space or access panel
C. 3 lbs per square foot lead A. B. A ladder and a light fixture
D. zinc-coated steel Schedule 80 C. Red brass fittings
D. Rubber gaskets A. Flaring tool D. Elevation
B. Pipe wrench
151. The overflow pipe from a fixture shall be connected on C. Monkey wrench 168. Is a measure on which all other elevations are based.
the _____. D. Soldering tool A. Bench mark
A. House or inlet side of the fixtures trap B. Elevation
B. Sewer or outlet side of the fixture trap 160. It is prohibited on new building sewer except for C. Datum
C. Downstream side of the fixture tee repairs and connections to existing line construction. D. Base elevation
D. Upstream side of the fixture tee A. Cement mortar joints
B. Burned lead joint 169. Elevation drawing that would provide the plumber with
152. The diameter of a waste and overflow for a bathtub C. Wiped joint information as to the width and height of a specific portion
shall not be less than ____. D. Threaded joint of the structure.
A. 1 1/2 inches OD A. Sectional elevation
B. 1 1/4 inches OD 161. Joints between asbestos cement pipe and other B. Invert elevation
C. 1 3/8 inches OD approved pipe shall be made by means of an: C. Based elevation
D. 1 3/8 inches OD A. Approved adapter coupling D. Longitudinal elevation
B. Approved male thread
153. Wipe lead joints shall have an exposed surface on C. Press fitting 170. A surveyor’s level with a short inverted telescope
each side of a joint not less than _____ at least as the D. Push on fitting rigidly affixed. It rotates in a horizontal plane only.
material being joined. A. Dumpy level
A. 3/4" 162. Hot and Cold water lines for kitchen sink should be B. leveling rod
B. 1 1/4" ___ from the finished floor. C. engineer’s scale
C. 1/2” A. 584 mm D. Spirit level
D. 1” B. 545 mm
C. 640 mm 171. A graduated rod used in measuring the vertical
154. In caulk joints, after caulking the finished joint shall not D. 501 mm distance between a point on the ground.
extend more than ____ below the rim hub. A. Leveling rod
A. 3.2 mm 163. If one compartment of a two compartment sink is to be B. Dumpy rod
B. 2.3 mm provided with a garbage disposal, the waste line should C. Engineer’s rod
C. 4 mm rough in at ___ above the finished floor. D. Spirit rod
D. 5 mm A. 406 mm
B. 585 mm 172. Absolute pressure is:
155. It shall be lubricated with water-insoluble, non- C. 385 mm A. Back pressure + siphonage
hardening material in threaded joints. D. 501 mm B. Gage pressure + atmospheric pressure
A. Cleanout plugs and caps C. Gage pressure + siphonage
B. P-trap plugs and caps 164. Rim of sink and surrounding counter should be D. Atmospheric pressure + back pressure
C. Water seal p-trap adjustable in height from a fixed height of ___.
D. Long sweep A. 865 mm 173. It is preferable temperature when using automatic
B. 545 mm laundry and dishwashing machines.
156. It is always good practice to flush the newly opened C. 684 mm A. 160⁰F
drain with hot water for at least? D. 756 mm B. 168⁰F
A. 5 mins C. 175⁰F
B. 15 mins 165. The P-trap top should be no higher than ___ below D. 190⁰F
C. 10 mins floor level.
D. 3 mins A. 180 mm 174. If hot water pipes are insulated, the heat loss from
B. 152 mm pipes is reduced by up to ___.
157. It is acceptable for use on male threads, only if C. 102 mm A. 80%
screwed pipe joint. D. 205 mm B. 50%
A. Tape C. 65%
B. Silicon 166. It protects the lead from corrosion during the curing D. 70%
C. Lead period of the concrete caused by a chemical reaction that
D. Rugby occurs between concrete, lead, and the water seeping 175. A special device used to prevent corrosion in some
through and contacting both. water heaters.
158. Joints between lead pipe and cast iron, steel or A. lead A. protector rod
wrought iron pipe shall be made by means of a caulking B. asphaltum B. TP relief valve
ferrule or? C. Butimonuos coating C. mixing valve
A. soldering nipple D. Oakum D. electric rod
B. Soldering coupling
C. Shielded coupling 167. Is an established level or elevation from which vertical 176. Standard length of a fire hose.
D. Brazed nipple measurements are taken. A. 23 m
A. Datum B. 30 m
159. Soft copper water tubing shall be expanded with a B. Bench mark C. 15 m
proper: C. Base elevation D. 10 m
D. leader
177. Approximate heights of a service sink from floor level
to fixture rim. 186. Ph 0 stands for:
A. 36" A. acidic
B. 32" B. Alkaline
C. 28" C. Neutral
D. 30" D. Basic
178. Allowed total dfu in a horizontal branch with a 4” 187. Primary function is to provide air circulation of air
diameter. between drainage and vent systems.
A. 160 dfu A. relief vent
B. 20 dfu B. re-vent
C. 360 dfu C. Circuit vent
D. 620 dfu D. local vent
179. The vertical portion of a rainwater conductor. 188. Approximate heights of a water closet from floor level
A. Downspout to fixture rim.
B. Horizontal pipe A. 15"
C. Catch basin B. 12"
D. Gutter C. 10"
D. 18"
180. A flange that closes the end of a pipe.
A. Blind flange 189. Is the discharge from any fixture, appliance or
B. Blank flange appurtenance in connection with a plumbing system which
C. Flat flange does not received fecal matter?
D. Ring flange A. liquid waste
B. Waste pipe
181. Part of the lowest horizontal piping of a drainage C. Sewer line
system which receives the discharge from soil, waste and D. Waste
other drainage pipes inside the walls of the building.
A. Building drain
B. Building sewer
C. Building subdrain
D. Building supply