Original Design (Tender)

1- Duct Provided insufficient Size(Too Many FOC Running in the Duct)


2- To many FOC to Pull
3- Risk of FOC damage without Sub Duct is higher
4- Future Maintenance difficult to trace
5- Cable Management is untidy and messy
6- The Design is redundancy only in one direction
7- At Toll Plaza , the original design FOC entering the server room is going to be messy and difficult
to identify
8- The Original design , space Constrains at parapet opening due to many FOC running thru at the
opening (insufficient space for Enclosure Jointing)
9- Fiber size to big when bundling together in the duct
10- Total Cable Length is 174 050 meter for 4 Core Cable
11- Cost Impact higher due to many FOC to lay for more jointing provided

Proposal Design

1- Cable management is more efficient


2- Future Maintenance is easier to trace the faulty FOC
3- The Proposal Design have taken into account of redundancy from multiple direction
4- The Proposal Design is neat and tidy and easy to assign the Fiber Core
5- Sufficient Space in Parapet Opening to place the enclosure /joint due to only 1 cable ring thru
6- All the fiber can bundle into 1 cable, this is reducing real size
7- Total Cable Length is 50 000 meter for 48 Core Cable
8- Cost Impact lower due to minimum amount of FOC to lay is less jointing provided