Вы находитесь на странице: 1из 16

Lifetime Homes (1) Car Parking Width Page 1 of 1

home text only

16 LTH standards Questions about LTH case studies log in news contact

(1) Car Parking Width


Where car parking is adjacent to the home, it should be capable of enlargement to
z (1) Car Parking Width attain 3.3m width.
z (2) Access From Car Parking
z (3) Approach Gradients
z (4) External Entrances Stated specifications and dimensions to conform
z (5) Communal Stairs & Lifts
z (6) Doorways & Hallways The general parking space width of 2400mm must have a grass verge or path
z (7) Wheelchair Accessibility
900mm wide running beside to enable the hard landscaping to have an overall
z (8) Living Room
width of 3300mm at a later date.
z (9) Entrance Level Bedspace
z (10) Entrance Level WC &
Shower Drainage
z (11) Bathroom & WC Walls
z (12) Stair Lift/Through-Floor
Lift
z (13) Tracking Hoist Route
z (14) Bathroom Layout
z (15) Window Specification
z (16) Controls, Fixtures &
Fittings

© copyright Habinteg Housing Association

http://www.lifetimehomes.org.uk/pages/criteria1.html 05/01/2007
Lifetime Homes (2) Access From Car Parking Page 1 of 1

home text only

16 LTH standards Questions about LTH case studies log in news contact

(2) Access From Car Parking


The distance from the car parking space to the home should be kept to a
z (1) Car Parking Width minimum and should be level or gently sloping.
z (2) Access From Car Parking
z (3) Approach Gradients
z (4) External Entrances Stated specifications and dimensions to conform
z (5) Communal Stairs & Lifts
z (6) Doorways & Hallways A level approach is preferable. Where topography prevents this, a maximum
z (7) Wheelchair Accessibility
gradient on an individual slope is permissible as follows:
z (8) Living Room
z (9) Entrance Level Bedspace
z (10) Entrance Level WC &
1:12 if the slope is less than 5m;
Shower Drainage 1:15 if it is between 5m – 10m;
z (11) Bathroom & WC Walls 1:20 where the slope is more than 10m.
z (12) Stair Lift/Through-Floor
Lift There must be top, bottom and intermediate 1200mm clear landings.
z (13) Tracking Hoist Route Paths should be a minimum 900mm wide.
z (14) Bathroom Layout
z (15) Window Specification
z (16) Controls, Fixtures &
Fittings

© copyright Habinteg Housing Association

http://www.lifetimehomes.org.uk/pages/criteria2.html 05/01/2007
Lifetime Homes (3) Approach Gradients Page 1 of 1

home text only

16 LTH standards Questions about LTH case studies log in news contact

(3) Approach Gradients


The approach to all entrances should be level or gently sloping.
z (1) Car Parking Width
z (2) Access From Car Parking
z (3) Approach Gradients Stated specifications and dimensions to conform
z (4) External Entrances
z (5) Communal Stairs & Lifts The specification for Criteria 2 gives the definition of gently sloping.
z (6) Doorways & Hallways
z (7) Wheelchair Accessibility
z (8) Living Room
z (9) Entrance Level Bedspace
z (10) Entrance Level WC &
Shower Drainage
z (11) Bathroom & WC Walls
z (12) Stair Lift/Through-Floor
Lift
z (13) Tracking Hoist Route
z (14) Bathroom Layout
z (15) Window Specification
z (16) Controls, Fixtures &
Fittings

© copyright Habinteg Housing Association

http://www.lifetimehomes.org.uk/pages/criteria3.html 05/01/2007
Lifetime Homes (4) External Entrances Page 1 of 1

home text only

16 LTH standards Questions about LTH case studies log in news contact

(4) External Entrances


All entrances should be illuminated, have level access over the threshold and
z (1) Car Parking Width have a covered main entrance.
z (2) Access From Car Parking
z (3) Approach Gradients
z (4) External Entrances Stated specifications and dimensions to conform
z (5) Communal Stairs & Lifts
z (6) Doorways & Hallways The threshold upstand should not exceed 15mm.
z (7) Wheelchair Accessibility
z (8) Living Room
z (9) Entrance Level Bedspace
z (10) Entrance Level WC &
Shower Drainage
z (11) Bathroom & WC Walls
z (12) Stair Lift/Through-Floor
Lift
z (13) Tracking Hoist Route
z (14) Bathroom Layout
z (15) Window Specification
z (16) Controls, Fixtures &
Fittings

© copyright Habinteg Housing Association

http://www.lifetimehomes.org.uk/pages/criteria4.html 05/01/2007
Lifetime Homes (5) Communal Stairs & Lifts Page 1 of 1

home text only

16 LTH standards Questions about LTH case studies log in news contact

(5) Communal Stairs & Lifts


Communal stairs should provide easy access and, where homes are reached by
z (1) Car Parking Width a lift, it should be fully accessible.
z (2) Access From Car Parking
z (3) Approach Gradients
z (4) External Entrances Stated specifications and dimensions to conform
z (5) Communal Stairs & Lifts
z (6) Doorways & Hallways Communal stairs:
z (7) Wheelchair Accessibility
Uniform rise not more than 170mm, uniform going not less than 250mm.
z (8) Living Room
Handrails extend 300mm beyond top and bottom step, handrail height 900mm
z (9) Entrance Level Bedspace
z (10) Entrance Level WC &
from each nosing.
Shower Drainage
z (11) Bathroom & WC Walls Lifts:
z (12) Stair Lift/Through-Floor Clear landing entrances minimum 1500mm x 1500mm
Lift Minimum internal dimensions 1100mm x 1400mm
z (13) Tracking Hoist Route Controls between 900 – 1200mm from floor and 400mm from the lift’s internal
z (14) Bathroom Layout front wall.
z (15) Window Specification
z (16) Controls, Fixtures &
Fittings

© copyright Habinteg Housing Association

http://www.lifetimehomes.org.uk/pages/criteria5.html 05/01/2007
Lifetime Homes (6) Doorways & Hallways Page 1 of 1

home text only

16 LTH standards Questions about LTH case studies log in news contact

(6) Doorways & Hallways


The width of internal doorways and hallways should conform to Part M, except
z (1) Car Parking Width that when the approach is not head on and the hallway width is 900mm, the clear
z (2) Access From Car Parking
opening width should be 900mm rather than 800mm. There should be a 300mm
z (3) Approach Gradients
nib or wall space to the side of the leading edge of the doors on entrance level.
z (4) External Entrances
z (5) Communal Stairs & Lifts
z (6) Doorways & Hallways Stated specifications and dimensions to conform
z (7) Wheelchair Accessibility
z (8) Living Room
Front door:
z (9) Entrance Level Bedspace
z (10) Entrance Level WC &
Clear opening width of 800mm, with a 300 nib to the side of the leading edge.
Shower Drainage
z (11) Bathroom & WC Walls Internal + Back doors:
z (12) Stair Lift/Through-Floor Clear opening width of 750mm / corridor or passageway width 900mm if the
Lift approach is head-on or 1200mm when the approach in not head-on, clear
z (13) Tracking Hoist Route opening width 775mm / corridor 1050mm when the approach is not head on,
z (14) Bathroom Layout 900mm / 900mm corridor when the approach is not head on.
z (15) Window Specification Doors on the entrance level should have a 300mm nib to the leading edge.
z (16) Controls, Fixtures &
Fittings

© copyright Habinteg Housing Association

http://www.lifetimehomes.org.uk/pages/criteria6.html 05/01/2007
Lifetime Homes (7) Wheelchair Accessibility Page 1 of 1

home text only

16 LTH standards Questions about LTH case studies log in news contact

(7) Wheelchair Accessibility


There should be space for turning a wheelchair in dining areas and living rooms
z (1) Car Parking Width and adequate circulation space for wheelchairs elsewhere.
z (2) Access From Car Parking
z (3) Approach Gradients
z (4) External Entrances Stated specifications and dimensions to conform
z (5) Communal Stairs & Lifts
z (6) Doorways & Hallways A turning circle of 1500mm or a turning ellipse of 1700mm x 1400mm is required
z (7) Wheelchair Accessibility
in living rooms and dining areas.
z (8) Living Room
z (9) Entrance Level Bedspace
z (10) Entrance Level WC &
Shower Drainage
z (11) Bathroom & WC Walls
z (12) Stair Lift/Through-Floor
Lift
z (13) Tracking Hoist Route
z (14) Bathroom Layout
z (15) Window Specification
z (16) Controls, Fixtures &
Fittings

© copyright Habinteg Housing Association

http://www.lifetimehomes.org.uk/pages/criteria7.html 05/01/2007
Lifetime Homes (8) Living Room Page 1 of 1

home text only

16 LTH standards Questions about LTH case studies log in news contact

(8) Living Room


The living room should be at entrance level.
z (1) Car Parking Width
z (2) Access From Car Parking
z (3) Approach Gradients Stated specifications and dimensions to conform
z (4) External Entrances
z (5) Communal Stairs & Lifts Living room at entrance level.
z (6) Doorways & Hallways
z (7) Wheelchair Accessibility
z (8) Living Room
z (9) Entrance Level Bedspace
z (10) Entrance Level WC &
Shower Drainage
z (11) Bathroom & WC Walls
z (12) Stair Lift/Through-Floor
Lift
z (13) Tracking Hoist Route
z (14) Bathroom Layout
z (15) Window Specification
z (16) Controls, Fixtures &
Fittings

© copyright Habinteg Housing Association

http://www.lifetimehomes.org.uk/pages/criteria8.html 05/01/2007
Lifetime Homes (9) Entrance Level Bedspace Page 1 of 1

home text only

16 LTH standards Questions about LTH case studies log in news contact

(9) Entrance Level Bedspace


In houses of two or more storeys, there should be space on the entrance level
z (1) Car Parking Width that could be used as a convenient bed space.
z (2) Access From Car Parking
z (3) Approach Gradients
z (4) External Entrances Stated specifications and dimensions to conform
z (5) Communal Stairs & Lifts
z (6) Doorways & Hallways A space on the entrance level that could conveniently be used as a bed-space.
z (7) Wheelchair Accessibility
z (8) Living Room
z (9) Entrance Level Bedspace
z (10) Entrance Level WC &
Shower Drainage
z (11) Bathroom & WC Walls
z (12) Stair Lift/Through-Floor
Lift
z (13) Tracking Hoist Route
z (14) Bathroom Layout
z (15) Window Specification
z (16) Controls, Fixtures &
Fittings

© copyright Habinteg Housing Association

http://www.lifetimehomes.org.uk/pages/criteria9.html 05/01/2007
Lifetime Homes (10) Entrance Level WC & Shower Drainage Page 1 of 1

home text only

16 LTH standards Questions about LTH case studies log in news contact

(10) Entrance Level WC & Shower Drainage


In houses with three or more bedrooms, and all dwellings on one level, there
z (1) Car Parking Width should be a wheelchair accessible toilet at entrance level with drainage provision
z (2) Access From Car Parking
enabling a shower to be fitted in the future. In houses with two bedrooms the
z (3) Approach Gradients
downstairs toilet should conform at least to Part M.
z (4) External Entrances
z (5) Communal Stairs & Lifts
z (6) Doorways & Hallways Stated specifications and dimensions to conform
z (7) Wheelchair Accessibility
z (8) Living Room
The drainage for the future shower should be provided in all dwellings.
z (9) Entrance Level Bedspace
z (10) Entrance Level WC &
For dwellings with 3 or more bedrooms or on one level, the WC must be fully
Shower Drainage accessible. A wheelchair user should be able to close the door from within and
z (11) Bathroom & WC Walls achieve side transfer from a wheelchair to one side of the WC. There must be
z (12) Stair Lift/Through-Floor 1100mm clear space to the front of the bowl. The shower provision must be within
Lift the closet or adjacent to the WC.
z (13) Tracking Hoist Route A Part M WC is adequate for dwellings on 2 or more storeys with 1 or 2
z (14) Bathroom Layout bedrooms.
z (15) Window Specification
z (16) Controls, Fixtures &
Fittings

© copyright Habinteg Housing Association

http://www.lifetimehomes.org.uk/pages/criteria10.html 05/01/2007
Lifetime Homes (11) Bathroom & WC Walls Page 1 of 1

home text only

16 LTH standards Questions about LTH case studies log in news contact

(11) Bathroom & WC Walls


Walls in the bathroom and WC should be capable of taking adaptations such as
z (1) Car Parking Width handrails.
z (2) Access From Car Parking
z (3) Approach Gradients
z (4) External Entrances Stated specifications and dimensions to conform
z (5) Communal Stairs & Lifts
z (6) Doorways & Hallways Wall reinforcements (if required) should be located between 300 and 1500mm
z (7) Wheelchair Accessibility
from the floor.
z (8) Living Room
z (9) Entrance Level Bedspace
z (10) Entrance Level WC &
Shower Drainage
z (11) Bathroom & WC Walls
z (12) Stair Lift/Through-Floor
Lift
z (13) Tracking Hoist Route
z (14) Bathroom Layout
z (15) Window Specification
z (16) Controls, Fixtures &
Fittings

© copyright Habinteg Housing Association

http://www.lifetimehomes.org.uk/pages/criteria11.html 05/01/2007
Lifetime Homes (12) Stair Lift/Through-Floor Lift Page 1 of 1

home text only

16 LTH standards Questions about LTH case studies log in news contact

(12) Stair Lift/Through-Floor Lift


The design should incorporate provision for a future stair lift and a suitably
z (1) Car Parking Width identified space for a through the floor lift from the ground floor to the first floor, for
z (2) Access From Car Parking
example to a bedroom next to the bathroom.
z (3) Approach Gradients
z (4) External Entrances
z (5) Communal Stairs & Lifts Stated specifications and dimensions to conform
z (6) Doorways & Hallways
z (7) Wheelchair Accessibility
There must be a minimum of 900mm clear distance between the stair wall (on
z (8) Living Room
which the stair lift would normally be fixed) and the edge of the opposite
z (9) Entrance Level Bedspace
z (10) Entrance Level WC &
handrail/balustrade.
Shower Drainage Unobstructed ‘landings’ are needed at the top and bottom of the stairs.
z (11) Bathroom & WC Walls
z (12) Stair Lift/Through-Floor
Lift
z (13) Tracking Hoist Route
z (14) Bathroom Layout
z (15) Window Specification
z (16) Controls, Fixtures &
Fittings

© copyright Habinteg Housing Association

http://www.lifetimehomes.org.uk/pages/criteria12.html 05/01/2007
Lifetime Homes (13) Tracking Hoist Route Page 1 of 1

home text only

16 LTH standards Questions about LTH case studies log in news contact

(13) Tracking Hoist Route


The design and specification should provide a reasonable route for a potential
z (1) Car Parking Width hoist from a main bedroom to the bathroom.
z (2) Access From Car Parking
z (3) Approach Gradients
z (4) External Entrances Stated specifications and dimensions to conform
z (5) Communal Stairs & Lifts
z (6) Doorways & Hallways Technological advances in hoist design mean that a straight run is no longer
z (7) Wheelchair Accessibility
required.
z (8) Living Room
z (9) Entrance Level Bedspace
z (10) Entrance Level WC &
Shower Drainage
z (11) Bathroom & WC Walls
z (12) Stair Lift/Through-Floor
Lift
z (13) Tracking Hoist Route
z (14) Bathroom Layout
z (15) Window Specification
z (16) Controls, Fixtures &
Fittings

© copyright Habinteg Housing Association

http://www.lifetimehomes.org.uk/pages/criteria13.html 05/01/2007
Lifetime Homes (14) Bathroom Layout Page 1 of 1

home text only

16 LTH standards Questions about LTH case studies log in news contact

(14) Bathroom Layout


The bathroom should be designed for ease of access to the bath, WC and wash
z (1) Car Parking Width basin.
z (2) Access From Car Parking
z (3) Approach Gradients
z (4) External Entrances Stated specifications and dimensions to conform
z (5) Communal Stairs & Lifts
z (6) Doorways & Hallways Although there is not a requirement for a turning circle in bathrooms, sufficient
z (7) Wheelchair Accessibility
space should be provided so that a wheelchair user can conveniently use the
z (8) Living Room
bathroom and gain side access to the WC.
z (9) Entrance Level Bedspace
z (10) Entrance Level WC &
Shower Drainage
z (11) Bathroom & WC Walls
z (12) Stair Lift/Through-Floor
Lift
z (13) Tracking Hoist Route
z (14) Bathroom Layout
z (15) Window Specification
z (16) Controls, Fixtures &
Fittings

© copyright Habinteg Housing Association

http://www.lifetimehomes.org.uk/pages/criteria14.html 05/01/2007
Lifetime Homes (15) Window Specification Page 1 of 1

home text only

16 LTH standards Questions about LTH case studies log in news contact

(15) Window Specification


Living room window glazing should begin no higher than 800mm from the floor
z (1) Car Parking Width level and windows should be easy to open/operate.
z (2) Access From Car Parking
z (3) Approach Gradients
z (4) External Entrances Stated specifications and dimensions to conform
z (5) Communal Stairs & Lifts
z (6) Doorways & Hallways People should be able to see out of the window whilst seated. Wheelchair users
z (7) Wheelchair Accessibility
should be able to operate at least one window in each room.
z (8) Living Room
z (9) Entrance Level Bedspace
z (10) Entrance Level WC &
Shower Drainage
z (11) Bathroom & WC Walls
z (12) Stair Lift/Through-Floor
Lift
z (13) Tracking Hoist Route
z (14) Bathroom Layout
z (15) Window Specification
z (16) Controls, Fixtures &
Fittings

© copyright Habinteg Housing Association

http://www.lifetimehomes.org.uk/pages/criteria15.html 05/01/2007
Lifetime Homes (16) Controls, Fixtures & Fittings Page 1 of 1

home text only

16 LTH standards Questions about LTH case studies log in news contact

(16) Controls, Fixtures & Fittings


Switches, sockets, ventilation and service controls should be at a height usable by
z (1) Car Parking Width all (i.e. between 450mm and 1200mm from the floor).
z (2) Access From Car Parking
z (3) Approach Gradients
z (4) External Entrances Stated specifications and dimensions to conform
z (5) Communal Stairs & Lifts
z (6) Doorways & Hallways This applies to all rooms, including the kitchen and bathroom.
z (7) Wheelchair Accessibility
z (8) Living Room
z (9) Entrance Level Bedspace
z (10) Entrance Level WC &
Shower Drainage
z (11) Bathroom & WC Walls
z (12) Stair Lift/Through-Floor
Lift
z (13) Tracking Hoist Route
z (14) Bathroom Layout
z (15) Window Specification
z (16) Controls, Fixtures &
Fittings

© copyright Habinteg Housing Association