Вы находитесь на странице: 1из 6

Project Job Ref.

Neecon Section Sheet no./rev.


1
Calc. by Date Chk'd by Date App'd by Date
A 7/14/2019

WIND LOADING (ASCE7-10)


In accordance with ASCE7-10 incorporating Errata No. 1 and Errata No. 2
Using the directional design method
Tedds calculation version 2.0.20
3 00 00

80 00
39000 30000
Plan Elevation

Building data
Type of roof; Gable
Length of building; b = 39000 mm
Width of building; d = 30000 mm
Height to eaves; H = 6500 mm
Pitch of roof; 0 = 5.7 deg
Mean height; h = 6500 mm
General wind load requirements
Basic wind speed; V = 50.0 m/s
Risk category; II
Velocity pressure exponent coeff (Table 26.6-1); Kd = 0.85
Exposure category (cl.26.7.3); C
Enclosure classification (cl.26.10); Enclosed buildings
Internal pressure coef +ve (Table 26.11-1); GCpi_p = 0.18
Internal pressure coef –ve (Table 26.11-1); GCpi_n = -0.18
Gust effect factor for rigid structures
Terrain exposure constants (Table 26.9-1)
Integral length scale factor; l = 152400 mm
Turbulence intensity factor; c = 0.20
Minimum equivalent height; zmin = 4572 mm
Peak factor for background response; gQ = 3.400
Peak factor for wind response; gv = 3.400
Integral length scale power law exponent;  = 0.200
Equivalent height of the structure; z = max (0.6  h, zmin) = 4572 mm
Intensity of turbulence (Eqn. 26.9-7); Iz = c  (33 ft /z)1/6 = 0.23
Project Job Ref.

Neecon Section Sheet no./rev.


2
Calc. by Date Chk'd by Date App'd by Date
A 7/14/2019

Integral length scale of turbulence (Eqn. 26.9-9); Lz = l  (z / 33 ft) = 130167 mm
Background response (Eqn. 26.9-8); Q = (1 / (1 + 0.63  ((min(B, L) + h) / Lz)0.63)) = 0.883
Gust effect factor (Eqn. 26.9-6); G = Gf = 0.925  (1 + 1.7  gQ  Iz  Q) / (1 + 1.7  gv  Iz) = 0.86

Topography
Topography factor not significant; Kzt = 1.0
Velocity pressure equation; q = 0.6131N/m2  Kz  Kzt  Kd  V2 / (1m/s)2;

Velocity pressures table


z (mm) Kz (Table 27.3-1) qz (kN/m2)
6500 0.91 1.19
8000 0.95 1.24
6500 0.91 1.19
8000 0.95 1.24

Peak velocity pressure for internal pressure


Peak velocity pressure – internal (as roof press.); qi = 1.186 kN/m2
Pressures and forces
Net pressure; p = q  Gf  Cpe - qi  GCpi;
Net force; Fw = p  Aref;

Roof load case 1 - Wind 0, GCpi 0.18, -cpe


Ref. Ext pressure Peak velocity Net pressure Area Net force
Zone height coefficient cpe pressure qp p Aref Fw
(m) (kN/m2) (kN/m2) (m2) (kN)
A (-ve) 6.50 -0.90 1.19 -1.14 127.38 -144.61
B (-ve) 6.50 -0.90 1.19 -1.14 127.38 -144.61
C (-ve) 6.50 -0.50 1.19 -0.73 254.76 -184.86
D (-ve) 6.50 -0.30 1.19 -0.52 78.39 -40.82
E (-ve) 6.50 -0.30 1.19 -0.52 587.92 -306.16
Total vertical net force; Fw,v = -816.99 kN
Total horizontal net force; Fw,h = -20.77 kN
Walls load case 1 - Wind 0, GCpi 0.18, -cpe
Ref. Ext pressure Peak velocity Net pressure Area Net force
Zone height coefficient cpe pressure qp p Aref Fw
(m) (kN/m2) (kN/m2) (m2) (kN)
A1 6.50 0.80 1.19 0.61 253.50 153.58
A2 8.00 0.80 1.24 0.64 58.50 37.51
A3 6.50 0.80 1.19 0.61 -58.50 -35.44
B 6.50 -0.50 1.19 -0.73 253.50 -183.94
C 6.50 -0.70 1.19 -0.93 217.50 -202.37
D 6.50 -0.70 1.19 -0.93 217.50 -202.37

Overall loading
Projected vertical plan area of wall; Avert_w_0 = b  H = 253.50 m2
Project Job Ref.

Neecon Section Sheet no./rev.


3
Calc. by Date Chk'd by Date App'd by Date
A 7/14/2019

Projected vertical area of roof; Avert_r_0 = b  d/2  tan(0) = 58.50 m2


Minimum overall horizontal loading; Fw,total_min = pmin_w  Avert_w_0 + pmin_r  Avert_r_0 = 217.4 kN
Leeward net force; Fl = Fw,wB = -183.9 kN
Windward net force; Fw = Fw,wA_1 + Fw,wA_2 + Fw,wA_3 = 155.6 kN
Overall horizontal loading; Fw,total = max(Fw - Fl + Fw,h, Fw,total_min) = 318.8 kN
Roof load case 2 - Wind 0, GCpi -0.18, +cpe
Ref. Ext pressure Peak velocity Net pressure Area Net force
Zone height coefficient cpe pressure qp p Aref Fw
(m) (kN/m2) (kN/m2) (m2) (kN)
A (+ve) 6.50 -0.18 1.19 0.03 127.38 3.71
B (+ve) 6.50 -0.18 1.19 0.03 127.38 3.71
C (+ve) 6.50 -0.18 1.19 0.03 254.76 7.43
D (+ve) 6.50 -0.18 1.19 0.03 78.39 2.29
E (+ve) 6.50 -0.18 1.19 0.03 587.92 17.14
Total vertical net force; Fw,v = 34.12 kN
Total horizontal net force; Fw,h = 0.00 kN
Walls load case 2 - Wind 0, GCpi -0.18, +cpe
Ref. Ext pressure Peak velocity Net pressure Area Net force
Zone height coefficient cpe pressure qp p Aref Fw
(m) (kN/m2) (kN/m2) (m2) (kN)
A1 6.50 0.80 1.19 1.03 253.50 261.83
A2 8.00 0.80 1.24 1.07 58.50 62.49
A3 6.50 0.80 1.19 1.03 -58.50 -60.42
B 6.50 -0.50 1.19 -0.30 253.50 -75.69
C 6.50 -0.70 1.19 -0.50 217.50 -109.49
D 6.50 -0.70 1.19 -0.50 217.50 -109.49

Overall loading
Projected vertical plan area of wall; Avert_w_0 = b  H = 253.50 m2
Projected vertical area of roof; Avert_r_0 = b  d/2  tan(0) = 58.50 m2
Minimum overall horizontal loading; Fw,total_min = pmin_w  Avert_w_0 + pmin_r  Avert_r_0 = 217.4 kN
Leeward net force; Fl = Fw,wB = -75.7 kN
Windward net force; Fw = Fw,wA_1 + Fw,wA_2 + Fw,wA_3 = 263.9 kN
Overall horizontal loading; Fw,total = max(Fw - Fl + Fw,h, Fw,total_min) = 339.6 kN
Roof load case 3 - Wind 90, GCpi 0.18, -cpe
Ref. Ext pressure Peak velocity Net pressure Area Net force
Zone height coefficient cpe pressure qp p Aref Fw
(m) (kN/m2) (kN/m2) (m2) (kN)
A (-ve) 6.50 -0.90 1.19 -1.14 97.99 -111.24
B (-ve) 6.50 -0.90 1.19 -1.14 97.99 -111.24
C (-ve) 6.50 -0.50 1.19 -0.73 195.97 -142.20
D (-ve) 6.50 -0.30 1.19 -0.52 783.89 -408.22
Project Job Ref.

Neecon Section Sheet no./rev.


4
Calc. by Date Chk'd by Date App'd by Date
A 7/14/2019

Total vertical net force; Fw,v = -769.06 kN


Total horizontal net force; Fw,h = 0.00 kN
Walls load case 3 - Wind 90, GCpi 0.18, -cpe
Ref. Ext pressure Peak velocity Net pressure Area Net force
Zone height coefficient cpe pressure qp p Aref Fw
(m) (kN/m2) (kN/m2) (m2) (kN)
A1 6.50 0.80 1.19 0.61 195.00 118.13
A2 8.00 0.80 1.24 0.64 22.50 14.43
A3 8.00 0.80 1.24 0.64 0.00 0.00
B 6.50 -0.44 1.19 -0.66 217.50 -144.45
C 6.50 -0.70 1.19 -0.93 253.50 -235.86
D 6.50 -0.70 1.19 -0.93 253.50 -235.86

Overall loading
Projected vertical plan area of wall; Avert_w_90 = d  H + d2  tan(0) / 4 = 217.50 m2
Projected vertical area of roof; Avert_r_90 = 0.00 m2
Minimum overall horizontal loading; Fw,total_min = pmin_w  Avert_w_90 + pmin_r  Avert_r_90 = 167.5 kN
Leeward net force; Fl = Fw,wB = -144.5 kN
Windward net force; Fw = Fw,wA_1 + Fw,wA_2 + Fw,wA_3 = 132.6 kN
Overall horizontal loading; Fw,total = max(Fw - Fl + Fw,h, Fw,total_min) = 277.0 kN
Roof load case 4 - Wind 90, GCpi -0.18, +cpe
Ref. Ext pressure Peak velocity Net pressure Area Net force
Zone height coefficient cpe pressure qp p Aref Fw
(m) (kN/m2) (kN/m2) (m2) (kN)
A (+ve) 6.50 -0.18 1.19 0.03 97.99 2.86
B (+ve) 6.50 -0.18 1.19 0.03 97.99 2.86
C (+ve) 6.50 -0.18 1.19 0.03 195.97 5.71
D (+ve) 6.50 -0.18 1.19 0.03 783.89 22.86
Total vertical net force; Fw,v = 34.12 kN
Total horizontal net force; Fw,h = 0.00 kN
Walls load case 4 - Wind 90, GCpi -0.18, +cpe
Ref. Ext pressure Peak velocity Net pressure Area Net force
Zone height coefficient cpe pressure qp p Aref Fw
(m) (kN/m2) (kN/m2) (m2) (kN)
A1 6.50 0.80 1.19 1.03 195.00 201.40
A2 8.00 0.80 1.24 1.07 22.50 24.04
A3 8.00 0.80 1.24 1.07 0.00 0.00
B 6.50 -0.44 1.19 -0.24 217.50 -51.57
C 6.50 -0.70 1.19 -0.50 253.50 -127.61
D 6.50 -0.70 1.19 -0.50 253.50 -127.61
Project Job Ref.

Neecon Section Sheet no./rev.


5
Calc. by Date Chk'd by Date App'd by Date
A 7/14/2019

Overall loading
Projected vertical plan area of wall; Avert_w_90 = d  H + d2  tan(0) / 4 = 217.50 m2
Projected vertical area of roof; Avert_r_90 = 0.00 m2
Minimum overall horizontal loading; Fw,total_min = pmin_w  Avert_w_90 + pmin_r  Avert_r_90 = 167.5 kN
Leeward net force; Fl = Fw,wB = -51.6 kN
Windward net force; Fw = Fw,wA_1 + Fw,wA_2 + Fw,wA_3 = 225.4 kN
Overall horizontal loading; Fw,total = max(Fw - Fl + Fw,h, Fw,total_min) = 277.0 kN

39000
15 000

3000 0
2000 D
65 00

C
3 250 3250

A
W ind - 0o

Plan view - Gable roof

A 32
6 500

A1

39000
Windward face
65 00

65 00

C B

30000 39000
Side face Leeward face
Project Job Ref.

Neecon Section Sheet no./rev.


6
Calc. by Date Chk'd by Date App'd by Date
A 7/14/2019

39000

30000
Wind - 90o
A B C D

3250 3250 6500 26000

Plan view - Gable roof

6500
A
A32
A1

30000
Windward face
6500

6500

C B

39000 30000
Side face Leeward face