Академический Документы
Профессиональный Документы
Культура Документы
PermaShield Pipe
PRODUCT CATALOG
Catalog 10/12.8
Fab-Tech, Inc.
A Critical Process Systems Group Company
®
Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®
Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®
STANDARDS 4
PermaShield Pipe (PSP®) Ductwork
Fabrication Standards
The Fab-Tech Ductwork Fabrication Standard Manual is designed to d. Testing shall be performed at the factory over the entire coated
aid you, our customer, in becoming acquainted with our fabrication surface inside and out (where applicable) and edges. The testing
practices. The manual is in strict accordance with the practices in the shall be performed with a DC spark tester used at 2500 volts.
latest S.M.A.C.N.A. manuals.
e. Delivery, Storage, and Handling:
1. Protection: Protection is factory applied to ends of
GENERAL ductwork to prevent end damage and prevent dirt and
moisture from entering ducts and fittings.
Codes and Standards
2. Delivery: Consignee must inspect shipment upon delivery
a. Ducts shall be listed for use without the necessity for internal fire
and note any and all damages and discrepancies on Bill of
protection sprinklers or any devices relied on to cut off air flow in the Lading and notify manufacturer within 24 hours.
event of fire by the following:
3. Storage: Coated ductwork should not be stored in an area
Factory Mutual Research Standard 4922 where it will have a chance to be damaged from traffic or
debris. All coated ductwork should be stored on cardboard,
Limitations and Requirements: Styrofoam or similar materials. Where possible, store inside
1. All ducts shall be interiorly furnished with a fluoropolymer and protect from dirt and debris. Where necessary to store
thermoplastic resin. The total interior coating thickness shall outside, store above ground and enclose with water proof
not exceed 16 mils (0.30 mm). Complete and uniform coating wrapping to protect from dirt and debris.
coverage is required. 4. Handling: If coating is scratched use appropriate protocol
2. This duct may be used for smoke removal in special to "spark test" (refer to Installation and Assembly Guide, Field
purpose areas when properly designed and sized. Sprinklers Modification section) and if spark is detected, contact
are not required. manufacturer for repair instruction.
3. The product shall be manufactured with identical resins as 5. Welding: Under no circumstances shall welding or a heat
tested, and according to the formulation on file with FMRC, source greater than 300°F (150°C) be allowed on the stainless
and shall meet all physical requirements of S.M.A.C.N.A. steel surface of the duct.
manual for Industrial Duct Construction Standards.
e. Duct Assembly shall be accomplished utilizing either companion
4. Vertical height of individual risers within the duct system rings or Fab-Tech's PSP-EZ™ clamp:
are not restricted, however, they shall not penetrate other fire
1. Companion rings are available as angle rings in sizes 4" thru
areas.
120” diameter or as cast rings in sizes 4” thru 14” diameter. The
5. The manufacturer shall determine the suitability of the duct minimum number of holes for flange connections is one hole for
systems for specific corrosive environments. each 4" of duct circumference to the next higher number.
6. If the process served by such duct system produces 2. PSP-EZ™ clamps are available in sizes 2" thru 14". The
flammable residue or a combustible fume source exceeding PSP-EZ™ band ring style of joining system shall provide a
1ft2 (0.09 m2) in area per inlet which can build up inside the minimum compression load to the gasket of 900 PSI.
duct, then internal sprinklers will be required.
f. Gasket Technology:
7. ASTM E-84 Standard Test Method for Surface Burning
1. Ring gasket material shall be PermaShield form in place,
Characteristics. Tested in flat sheet form at a 20 ga. (0.95 mm)
fully expanded 100% PTFE joint sealant.
thickness: Flame Spread 0, Smoke Density 20.
4"-30" diameter duct - .010" x .75" tape gasket
b. Fab-Tech's FM Global Approval ( 4922 ) extends the widest 32" diameter & up duct - 1/4" x 3/16" rope gasket
possible limits from 4" diameter ( 100mm ) up to and including 60" 2. PSP-EZ™ clamp gasket material shall be PermaShield form
diameter ( 1525mm ) duct and fittings. in place, fully expanded 100% PTFE tape or die cut gasket
(2"-3" diameter).
DUCTWORK
a. Base Metal shall be a series 300 Stainless Steel. Longitudinal
seams shall be fusion welded. Traverse seams shall be continuous
weld. All seams shall be smooth on the interior of duct.
b. Coating shall be PermaShield Fluoropolymer Barrier Coating and
shall be applied per Factory Mutual Research Corporation's Fab-Tech, Inc.
A Critical Process Systems Group Company
limitations and requirements.
c. Black Iron Rings shall be coated with PermaProtect, Black Iron
Ring Powder®. This heat and chip resistant coating is electro statically Visit our website at www.fabtechinc.com
applied and sintered to the substrate. Email address: sales@fabtechinc.com
Fab-Tech reserves the right
to change or modify specifications without notice.
PSP® and PSP-EZ™ are registered trademarks of Fab-Tech, Inc.
Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®
5 STANDARDS
Straight Duct Gauge
MIN GAUGE FOR 4' DUCT MIN GAUGE FOR 8' DUCT
DUCT STD DUCT DUCT
DIA -6" -10" -14" -18" DUCT DIA DIA
"D" WG WG WG WG LENGTH "D" "D"
STD
4 4 -6" -10" -14" -18" DUCT 4
WG WG WG WG LENGTH
6 6 6
8 8 8
10 10 10
20
12 12 12
20 20
14 14 20 14
20
16 16 16
18 18 18
20 20
20 20 18 20
22 22 22
24 24 18 24
26 20 47.25 26 26
28 28 18 95.25 28
30 30 16 30
18
32 32 32
34 34 34
16
36 18 36 36
38 38 38
40 40 40
18
42 42 42
14
44 44 16 44
46 18 46 46
48 16 48 48
50 50 50
14
52 52 52
54 54 54
56 16 56 56
58 58 58
60 60 60
62 62 16 62
64 18 64 64
14
66 66 66
68 68 68
70 16 14 70 70
72 72 72
12
74 74 74
76 76 76
78 46.75 78 94.75 78
80 80 80
82 14 82 82
84 84 84
12
86 86 86
88 88 88
90 90 90
14
92 92 92
94 94 94
96 96 96
98 16 98 98
12
100 100 100
102 14 12 102 102
104 104 104
106 106 106
108 108 108
12
110 110 110
10GA
112 112 112
OR
114 48.25 114 96.25 114
12 12 GA
116 116 116
WITH
118 118 118
14 STIFFENER
120 120 120
REV: 12/01/17 CAT005EA
Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®
STANDARDS 6
Ring Mechanical Specifications
RING MATERIAL
ANGLE RING SPECIFICATIONS & GASKETS CAST RING SPECIFICATIONS
PTFE GASKET
DUCT DIA
DUCT DIA
STAINLESS
DUCT DIA
THICKNESS
THICKNESS
BOLT HOLE
BOLT HOLE
BLACK
STEEL
# HOLES
# HOLES
CIRCLE
CIRCLE
WxH
IRON
HEIGHT
WIDTH
WIDTH
BOLT
BOLT
BOLT
BOLT
SIZE
SIZE
SIZE
DIA.
SIZE
DIA.
(W)
(W)
(H)
(T)
(T)
"D" "D" "D"
4 1 7/16 5.31 4 4 5.31
6 6 7/16
6
1/8 7/16 3/8
7.50 6 SC 6
3/8
7.50
1-1/4 13/32 1/8 x
8 1-1/4 x 9.50 8 8 9.50
FLOAT
8 8 11/16
10 11/16 11.50 10 10 11.50
12 13.81 12 .01
12 x 12 9/16 13.81
14 15.81 14 .75 BI 1-1/2 1/2 3/16 12 x 1/2
16 17.63 16 TAPE 14 3/4 15.81
16
FLOAT
18 1-1/2 19.63 18 GAS09
20 21.63 20 SS KEY: SC STAINLESS CAST RING
22 20 23.88 22
24 25.88 24 FLOAT SS STAINLESS STEEL ANGLE RING
26 27.88 26 BI BLACK IRON ANGLE RING
24
28 29.88 28
30 31.88 30 Notes:
28
32 33.88 32 Duct 4" to 14" manufactured with cast rings
34 35.88 34 as standard. Duct 16” to 120" manufactured
3/16 32
36 37.88 36 with angle rings as standard.
2
38 40.38 38
40
36
42.38 40
Standard mounting hole locations for welded
42 44.38 42
angle rings (32" to 120") straddle the vertical
44
40
46.38 44
centerline unless otherwise specified.
46 48.38 46 Standard hardware provided for angle ring
44 applications are plated GRADE 5 fasteners.
48 50.38 48
50 52.88 50 Stainless steel hardware is not recommended.
48
52 54.88 52
54 56.88 54
2-1/2 52
56 58.88 56
58 60.88 58 Grade 5 Bolt Markings:
56
60 62.88 60
62 64.88 62 SS BI Torque Specifications:
60 9/16
64 66.88 64
STITCH WELDED
STITCH WELDED
66 x 68.88 66
Torque in at least 3 stages
1/2
64 3/4
68 70.88 68 Duct Bolt
70 SLOT 72.88 70 Dia. Size Ft lb In lb M kg
68 1/4
72 74.88 72 x 4"-10" 3/8" 36 432 5.0
74 76.88 74 3/16
72 12"-120" 1/2" 75 900 10.4
76 78.88 76
GAS03
78 3 80.88 78
76
80 82.88 80
82 84.88 82 Duct and fittings greater than 84" diameter
80 requires engineering review and approval.
84 86.88 84
86 89.38 86 Custom angle rings available on request.
84
88 91.38 88 See Installation and Assembly Guide for metric
90 1/4 93.38 90 duct size conversions.
88
92 95.38 92
94 97.38 94
92 PTFE GASKETS* FOR RING JOINTS
96 100.38 96
98 102.38 98
96 4"-30"Ø 32"-120"Ø
100 104.38 100
102 106.38 102 .01 X .75 TAPE & RECTANGULAR
100 P/N: GAS09 1/4" x 3/16" ROPE
104 108.38 104
106 110.38 106 3/4" P/N: GAS03
104
108 4 112.38 108
110 114.38 110 SS 1/4"
108
112 116.38 112
WELDED
FULLY
Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®
7 STANDARDS
Ring Mechanical Specifications
RING
W RING
WIDTH W
WIDTH
DUCT
DIA DUCT
"D" DIA
"D"
ANGLE RING
BLACK IRON OR ANGLE RING
STAINLESS STEEL STAINLESS STEEL
PTFE
STITCH WELDS STITCH ROPE
WELD GASKET
FULL
DUCT PTFE ROPE GASKET DUCT WELD
Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®
STANDARDS 8
PSP-EZ™ Clamp Mechanical Specifications
CLAMP
DUCT DUCT GAUGE STRAIGHT BACKING
DIA. -6" Thru -18" DUCT RING DUCT DUCT
WG LENGTH
"D"
2 .035 TUBING
WELDED
3 .065 TUBING
4
6 4 FT
( 47.25" "D"
8 ACTUAL )
20 FLOATING
10
12
14
Torque Specifications:
Duct Bolt Torque in at least
Diameter Size 3 stages
lb*ft lb*in kg*m
4",6" 1/4" 6.25 75 0.9
8",10",12",14" 5/16" 10 120 1.4
Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®
Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®
Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®
DUCT
T.O.D.
90°
SPECIFY LOCATION
FROM "D1" END 4"
MIN
DUCT
FAB-TECH
FLANGE
"L"
CLAMP
"L"
EZ
ADAPTER
"D" OR PSP-EZ™
DUCT
Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®
T.O.D.
90°
"A1"
270°
SPECIFY TAP
LOCATION ANGLE
FROM 0°
"L2"
VIEW OF "D1" DUCT END
"L1"
Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®
T.O.D. 6"
90°
"A1"
270°
SPECIFY TAP
LOCATION ANGLE
FROM 0°
1" STD "C1"
"L2" 1" STD
VIEW OF "D1" DUCT END
"L1"
Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®
45°
T.O.D. 6" STD
90°
"A1"
270°
SPECIFY TAP
LOCATION ANGLE
FROM 0°
"L2"
VIEW OF "D1" DUCT END
"L1"
Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®
"D3"
T.O.D.
90°
"A1"
270°
SPECIFY TAP
LOCATION ANGLE
FROM 0°
Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®
"L1"
T.O.D.
STANDARD DUCT LENGTHS ( "L1" ) "L4" HORIZ.
T.O.D. SPECIFY OFFSET
TAP "L1" "L1"
ANGLE JOINT SYSTEM DIAMETER ( 4' ) ( 8' )
FROM 0° VERTICAL
90° AT D1 EZ CLAMP / 4" & 6" 47.25" NA 90° OFFSET
END CAST RING 8" TO 14" 47.25" 95.25" "L3" "L5"
B A
180° 0° 4" & 6" 47.25" NA
BLACK IRON 0°
"A1" 8" TO 48" 47.25" 95.25"
"L3" ANGLE RING C D
270° 50" TO 94" 46.75" 94.75"
16" TO 48" 47.25" 95.25"
STAINLESS
50" TO 100" 46.75" 94.75"
"D1" TAP ANGLE VIEW ANGLE RING "D1" TAP OFFSET VIEW
102" TO 120" 48.25" 96.25"
10½"
8" MIN
6" 7" MIN
MIN MIN 6"
MIN
Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®
90° ELBOW
LIMITATIONS
5 GORE
DUE TO MANUFACTURING LIMITATIONS, THE
FOLLOWING ELBOWS ARE NOT AVAILABLE AS
"D" ONE PIECE FITTINGS:
FULL RADIUS 90° ELBOW > 56" DIA.
FULL RADIUS 60° ELBOW > 82" DIA.
FULL RADIUS 45° ELBOW > 106" DIA.
HALF RADIUS 90° ELBOW > 76" DIA.
"R1"
LARGE ELBOWS ABOVE THESE LIMITS WILL
"R2"
BE MANUFACTURED AS SMALLER FITTINGS
( AN 86" DIA. 90° ELBOW WILL BE SUPPLIED
CL AS TWO 45° ELBOWS FOR EXAMPLE ) OR AS
A CLAM SHELL DESIGNED FITTING AS TWO
OR MORE PIECES. THIS APPLIES TO ALL
STANDARD RADIUS AT THE DUCT CENTERLINE LARGE FITTINGS AS WELL AS ELBOWS.
"R1" = 1.5 X "D" ALSO DUE TO MANUFACTURING LIMITATIONS,
STANDARD THROAT RADIUS MANY OF THE SMALLER 1/2 RADIUS ELBOWS
"R2" = "D" WILL REQUIRE CAST RINGS OR FLAT RINGS.
4 GORE
3 GORE
2 GORE
CL CL CL
60° ELBOW 45° ELBOW 30° ELBOW
Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®
"L3"
"D1"
"D2" "D1" "D2"
ECCENTRIC CONCENTRIC
Formula to calculate the minimum length for Formula to calculate the minimum length for
an eccentric reducer: a concentric reducer:
"L1" = "L2" + "L4" + "L5" "L1" = "L2" + "L4" + "L5"
Use this chart for minimum length of "L2": Use this chart for minimum length of "L2":
( Shorter taper or "L2" length can be fabricated, ( Shorter taper or "L2" length can be fabricated,
but will effect air flow. ) but will effect air flow. )
AMOUNT OF MINIMUM AMOUNT OF MINIMUM
REDUCTION LENGTH REDUCTION LENGTH
"D1" minus "D2" "L2" "D1" minus "D2" "L2"
6" AND LESS 12" 9" AND LESS 12"
7" TO 9" 18" 10" TO 14" 18"
10" TO 13" 24" 15" TO 19" 24"
14" TO 17" 30" 20" TO 24" 30"
Use this chart for minimum length of "L4" & "L5": Use this chart for minimum length of "L4 & "L5":
MINIMUM MINIMUM
DUCT DIAMETER LENGTH DUCT DIAMETER LENGTH
"D1" or "D2" "L4" or "L5" "D1" or "D2" "L4" or "L5"
4" TO 58" 3" 4" TO 58" 3"
60" TO 94" 4" 60" TO 94" 4"
96" TO 120" 5" 96" TO 120" 5"
Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®
NOTE
All fittings with standard Fab-Tech connections
include gaskets and clamps or hardware as
required for installation.
"D2"
"L2"
"D1"
"L1"
Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®
"D"
"D" DUCT DIA
DUCT DIA
1/2"
1/2"
4" - 14"
PSP-EZ™
4" - 14" CONFIGURATION
CAST RING
CONFIGURATION
END CAP - FLAT PLATE
( SEE OPTIONS )
END CAP - HAT STYLE
SAME AS FOR EZ CONFIG
( SEE OPTIONS )
"D"
DUCT DIA
"D"
DUCT DIA
16" - 120"
ANGLE RING CONFIGURATION
4" - 14" WITH ADDED SUPPORT
BLACK IRON ANGLE RING
ANGLE RING
CONFIGURATION TRANSVERSE STIFFENERS REQUIRED
FOR END CAPS OVER 36" DIA.
REV: 12/01/17 CAT020EA
Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®
NOTES
All fittings with standard Fab-Tech connections include gaskets and clamps or hardware as
required for installation.
Raw end available.
Round duct greater than 84" diameter requires Fab-Tech Engineering review and approval.
Rectangular duct width or height of 98" and larger requires Fab-Tech Engineering review.
A center stiffener (1" SCH40 pipe ) is added at the midpoint of the flange for rectangular duct
width or height of 50" and greater.
"X" "L1"
"R" "DØ"
"Y"
"L2"
3" MIN
Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®
Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®
23 CONTROL DEVICES
Product Guide
4"-12" WAFER 4"-14" INDUSTRIAL 4" INDUSTRIAL
ISOLATION BALANCING ISOLATION
CONTROL DAMPER DAMPER DAMPER
DEVICES
SIZE: 4"-12" SIZE: 4"-14" SIZE: 4"
PAGE: 24 PAGE: 26 PAGE: 27
6"-14" INDUSTRIAL AMCA 4"-14" INDUSTRIAL AMCA
ISOLATION 6"-14" INDUSTRIAL SHORT DAMPER - 16"-34" HIGH
DAMPER ISOLATION ISOLATION & VALUE HEAVY
DAMPER BALANCING DUTY INDUSTRIAL
SIZE: 6"-14" SIZE: 6"-14" SIZE: 4"-14" SIZE: 16"-34"
PAGE: 28 PAGE: 29 PAGE: 30 PAGE: 32
16"-48" HIGH VALUE
HEAVY DUTY
AMCA 50" & LARGER
HEAVY DUTY
24"-84"
ULTRA SERIES
36"-48" HIGH
INDUSTRIAL VALUE HEAVY INDUSTRIAL INDUSTRIAL
DAMPER (HVD) DUTY INDUSTRIAL DAMPER DAMPER
SIZE: 16"-34" SIZE: 36"-48" SIZE: 50"-120" SIZE: 24"-84"
PAGE: 33 PAGE: 34 PAGE: 35 PAGE: 36
4"-36" HORIZONTAL 16"-36" HORIZONTAL 38" & LARGER 38" & LARGER
RUN BLASTGATE RUN ACTUATED HORIZONTAL RUN HORIZONTAL RUN
BLASTGATE BLASTGATE ACTUATED
BLASTGATE
SIZE:4"-36" SIZE:4"-36" SIZE:38"-120" SIZE:38"-120"
PAGE: 38 PAGE: 39 PAGE: 40 PAGE: 41
4"-36" 16"-36" VERTICAL 38" & LARGER 38" & LARGER
VERTICAL RUN RUN ACTUATED VERTICAL RUN VERTICAL RUN
ISOLATION BLASTGATE ISOLATION ACTUATED
BLASTGATE BLASTGATE BLASTGATE
SIZE: 4"-36" SIZE: 16"-36" SIZE: 38"-120" SIZE: 38"-120"
PAGE: 42 PAGE: 43 PAGE: 44 PAGE: 45
Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®
CONTROL DEVICES 24
4"-14" Wafer Isolation Damper
SPECIFICATIONS
BODY: COATED SOLID ALUMINUM BODY
BODY LENGTH: 1"
COATING: PERMASHIELD FLUOROPOLYMER
BARRIER COATING
BLADE: COATED 10GA STAINLESS STEEL
WITH FULLY WELDED DRIVE AXLE
4"Ø BLADE: MACHINED PTFE
EDGE SEALS: VITON EXTRUDED RUBBER
BLADE HOLDERS: MOLDED 25% GLASS
FILLED PTFE
AXLE: DUAL SHAFT 1/2"Ø STAINLESS STEEL
AXLE SEALS: LIQUID TIGHT - POS & NEG
SYSTEM PRESSURE
BEARINGS: NYLON
COATING: FLUOROPOLYMER BARRIER
COATING
QUADRANT: MANUAL LOCKING HANDLE BOLT HOLE SPECIFICATIONS
LOCKOUT: 1/2° INTERVALS DUCT NO. BOLT BOLT BOLT
BLADE OPENS: CW DIA OF HOLE SIZE CIRCLE
OPEN/CLOSE TORQUE: 250 in-lb “D” HOLES SIZE DIA.
RECOMMENDED MIN 4 5.31
6
NOTE: All fittings with standard Fab-Tech 6 7.50
7/16 3/8
connections include gaskets and clamps or 8 9.50
8
hardware as required for installation. 10 11.50
12 13.81
12 9/16 1/2
14 15.81
C 1”
"D"
EXTRUDED
FLUOROELASTOMER
ISOLATION
BLADE SEAL
REV: 12/01/17 CAT024EA
Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®
25 CONTROL DEVICES
2" & 3" Micro-Adjustable EZ Damper
NOTE
All fittings with standard Fab-Tech connections include gaskets and
clamps or hardware as required for installation.
"L"
POSITION LOCK
ACTUATOR
THUMB WHEEL PLATE
FRICTION WHEEL
"D"
Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®
CONTROL DEVICES 26
4"-14" Industrial Balancing Damper
SPECIFICATIONS
BODY: COATED 20GA STAINLESS STEEL
BODY LENGTH: 9-1/4"
OPTION: CUSTOM LENGTH
COATING: PERMASHIELD FLUOROPOLYMER
BARRIER COATING
JOINING SYSTEM: FLOATING CAST STAINLESS
STEEL RINGS
OPTION: PSP-EZ™ JOINING SYSTEM 4"-14"
OPTION: FLOATING BLACK IRON
ANGLE RINGS 4"-14"
OPTION: CUSTOM HOLE PATTERN
PTFE BLADE: 4"Ø DAMPER ONLY
BLADE: COATED 10GA STAINLESS STEEL
BLADE HOLDERS: MOLDED PTFE
AXLES: DUAL SHAFT 1/2"Ø STAINLESS STEEL
AXLE SEALS: LIQUID TIGHT
ACTUATOR: MANUAL LEVER
OPTION: ELECTRIC ACTUATOR
OPTION: PNEUMATIC ACTUATOR
LOCKOUT: 1/2° INTERVALS
BLADE OPENS: CCW
OPEN/CLOSE TORQUE: 250 in-lb RECOMMENDED MIN 4" PTFE blade
with molded PTFE
NOTE: All fittings with standard Fab-Tech blade holders
connections include gaskets and clamps or
hardware as required for installation.
"D"
9.25" STD
Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®
27 CONTROL DEVICES
4" Industrial Isolation Damper
SPECIFICATIONS
BODY: COATED 20GA STAINLESS STEEL
0.35 BODY LENGTH: 9-1/4"
OPTION: CUSTOM LENGTH
0.3
COATING: PERMASHIELD FLUOROPOLYMER
Leakage (CFM)
0.01
"D"
0.001
100 1000 10000
Velocity (f/m) 9.25" STD
Pressure Drop Test based on AMCA Standard 500-D-98, Ref. Fig 5.3
REV: 12/01/17 CAT027EA
Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®
CONTROL DEVICES 28
6"-14" Industrial Isolation Damper
SPECIFICATIONS
BODY: COATED 20GA STAINLESS STEEL
BODY LENGTH: 9-1/4"
OPTION: CUSTOM LENGTH
COATING: PERMASHIELD FLUOROPOLYMER
BARRIER COATING
JOINING SYSTEM: FLOATING CAST STAINLESS
STEEL RINGS
OPTION: PSP-EZ™ JOINING SYSTEM 6"-14"
OPTION: FLOATING BLACK IRON
ANGLE RINGS 6"-14"
OPTION: CUSTOM HOLE PATTERN
BLADE: 10GA COATED STAINLESS STEEL
EDGE SEALS: FLUOROELASTOMER
BLADE HOLDERS: MOLDED PTFE
AXLES: DUAL SHAFT 1/2"Ø STAINLESS STEEL
AXLE SEALS: LIQUID TIGHT
ACTUATOR: MANUAL LEVER
OPTION: ELECTRIC ACTUATOR
OPTION: PNEUMATIC ACTUATOR
LOCKOUT: 1/2° INTERVALS
BLADE OPENS: CCW
OPEN/CLOSE TORQUE: 250 in-lb RECOMMENDED MIN
NOTE: All fittings with standard Fab-Tech
connections include gaskets and clamps or
hardware as required for installation.
"D"
VITON
EDGE
SEAL
3"
9.25" STD
Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®
29 CONTROL DEVICES
6"-14" AMCA Industrial Isolation Damper
Fab-Tech, Inc. certifies that the Industrial Single Blade
Isolation Damper shown herein is licensed to bear the CERTIFIED
AMCA Seal. The ratings shown are based on tests RATINGS
and procedures performed in accordance with AMCA
Publication 511 and comply with the requirements of
AIR
LEAKAGE
R
AIR
The AMCA Certified Ratings Seal applies to Air MOVEMENT
AND CONTROL
Leakage ratings and Air Performance ratings. ASSOCIATION
INTERNATIONAL, INC.
1. Test method per AMCA Standard 500-89
Data based on a seating torque of: 764 in-lbf/ft2
for 6" damper, 234 in-lbf/ft2 for 14" damper
2. Air leakage is based on operation between
SPECIFICATIONS
50°F & 104°F (10°C to 40°C) and data corrected
to represent standard air density 0.075 lbs/ft3. BODY: COATED 20GA STAINLESS STEEL
BODY LENGTH: 9-1/4"
Damper Dia. Pressure AMCA Leakage Class OPTION: CUSTOM LENGTH
1"WG 1A COATING: PERMASHIELD FLUOROPOLYMER
6" - 14" BARRIER COATING
4",8",12"WG 1
Tested Leakage Rates Available, Contact Fab-Tech Inc. JOINING SYSTEM: FLOATING CAST STAINLESS
STEEL RINGS
Leakage Classification L/s/m2 (ft3/min/ft2) OPTION: PSP-EZ™ JOINING SYSTEM 6"-14"
OPTION: FLOATING BLACK IRON
Pressure Required Extended
Class Range Range (Optional) ANGLE RINGS 6"-14"
OPTION: CUSTOM HOLE PATTERN
0.25 kPa 1.0 kPa 2.0 kPa 3.0 kPa
(1” wg) (4” wg) (8” wg) (12” wg) BLADE: 10GA COATED STAINLESS STEEL
EDGE SEALS: FLUOROELASTOMER
1A 15.2 (3)* N/A N/A N/A
BLADE HOLDERS: MOLDED PTFE
1 20.3 (4) 40.6 (8) 55.9 (11) 71.1 (14)
AXLES: DUAL SHAFT 1/2"Ø STAINLESS STEEL
2 50.8 (10) 102 (20) 142 (28) 178 (35) AXLE SEALS: LIQUID TIGHT
3 203 (40) 406 (80) 569 (112) 711 (140) ACTUATOR: MANUAL LEVER
*Units for maximum ratings in ( ) are CFM Sq. Ft. OPTION: ELECTRIC ACTUATOR
OPTION: PNEUMATIC ACTUATOR
Damper Leakage Test based on ANSI/AMCA Standard 500-D-07, Ref. Fig 5.6
Pressure Drop Test based on AMCA Standard 500-D-98, Ref. Fig 5.3 LOCKOUT: 1/2° INTERVALS
BLADE OPENS: CCW
OPEN/CLOSE TORQUE: 250 in-lb
1.0
RECOMMENDED MINIMUM
NOTE: All fittings with standard Fab-Tech
connections include gaskets and clamps or
Pressure Drop (in. wg)
10
14
0.01
"D"
0.001 EXTRUDED
FLUOROELASTOMER 3"
100 1000 10000 RUBBER EDGE SEAL
9.25" STD
Velocity (f/m) REV: 12/01/17 CAT029EA
Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®
CONTROL DEVICES 30
4"-14" Industrial Short Damper - Isolation & Balancing
SPECIFICATIONS
BODY: COATED 20GA STAINLESS STEEL
BODY LENGTH: 4" MINIMUM
OPTION: CUSTOM LENGTH
COATING: PERMASHIELD FLUOROPOLYMER
BARRIER COATING
JOINING SYSTEM: FLOATING CAST STAINLESS
STEEL RINGS
OPTION: FLOATING STAINLESS STEEL
FLAT RINGS 4"-14"
OPTION: FLOATING BLACK IRON
FLAT RINGS 4"-14"
OPTION: PSP-EZ™ JOINING SYSTEM 4"-14"
OPTION: CUSTOM HOLE PATTERN
BLADE: 4": VIRGIN TEFLON
6"-14":10GA COATED STAINLESS STEEL
EDGE SEALS: FLUOROELASTOMER
BLADE HOLDERS: MOLDED PTFE
AXLES: DUAL SHAFT 1/2"Ø STAINLESS STEEL
AXLE SEALS: LIQUID TIGHT
ACTUATOR: MANUAL LEVER
LOCKOUT: 1/2° INTERVALS
BLADE OPENS: CCW
OPEN/CLOSE TORQUE: 250 in-lb RECOMMENDED MIN
NOTE: All fittings with standard Fab-Tech 4" PTFE blade
connections include gaskets and clamps or with molded PTFE
hardware as required for installation. blade holders
"D"
Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®
31 CONTROL DEVICES
6”-14" Industrial Isolation Damper
PL-X
PL-Y PL-1 PL-4 PL-Z
PL-9 PL-2
6D min. 10D min.
D ± 0.02D D ± 0.02D
t d9
From Supply
System and
Airflow
Measuring
Section
Fig. 5.3: Test Damper Setup with Inlet and Outlet Ducts
Pressurized
Supply Air
Device
AIRFLOW Under
Test
PS9
Fig. 5.6: Test Damper Setup - Leakage Test with Damper under
Positive Pressure
Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®
CONTROL DEVICES 32
16"-34" AMCA High Value Heavy Duty Industrial Damper
Fab-Tech, Inc. certifies that the Industrial Single Blade
Isolation Damper shown herein is licensed to bear the CERTIFIED
AMCA Seal. The ratings shown are based on tests RATINGS
and procedures performed in accordance with AMCA
Publication 511 and comply with the requirements of
AIR
LEAKAGE
R
AIR
The AMCA Certified Ratings Seal applies to Air MOVEMENT
AND CONTROL
Leakage ratings and Air Performance ratings. ASSOCIATION
INTERNATIONAL, INC.
1. Test method per AMCA Standard 500-89
Data based on a seating torque of: 125 in-lbf/ft2
for 16" damper, 86 in-lbf/ft2 for 48" damper
2. Air leakage is based on operation between
50°F & 104°F (10°C to 40°C) and data corrected SPECIFICATIONS
to represent standard air density 0.075 lbs/ft3.
BODY: COATED 12GA STAINLESS STEEL
BODY LENGTH: 10"
Damper Dia. Pressure AMCA Leakage Class COATING: PERMASHIELD FLUOROPOLYMER
1"WG 1A BARRIER COATING
16" - 34" JOINING SYSTEM: STITCH WELDED COATED BLACK
4",8",12"WG 1 IRON VAN STONE RINGS
Tested Leakage Rates Available, Contact Fab-Tech Inc. OPTION: CUSTOM HOLE PATTERN
MOUNTING HOLES: STRADDLE VERTICAL
Leakage Classification L/s/m2 (ft3/min/ft2) CENTERLINE
Pressure Required Extended BLADE: 1/4" COATED STAINLESS STEEL WITH
Class Range Range (Optional) VITON EDGE SEAL
BLADE STOPS: WELDED
0.25 kPa 1.0 kPa 2.0 kPa 3.0 kPa AXLES: DUAL SHAFT 1.38Ø STAINLESS STEEL
(1” wg) (4” wg) (8” wg) (12” wg) AXLE SEALS: LIQUID TIGHT
1A 15.2 (3)* N/A N/A N/A SLEEVE BEARINGS: THERMOPLASTIC
1 20.3 (4) 40.6 (8) 55.9 (11) 71.1 (14) ACTUATOR: MANUAL LEVER
OPTION: MANUAL GEAR BOX W/ LOCK OUT
2 50.8 (10) 102 (20) 142 (28) 178 (35) OPTION: CUSTOM ACTUATOR MOUNTING KIT
3 203 (40) 406 (80) 569 (112) 711 (140) OPTION: ELECTRIC ACTUATOR
*Units for maximum ratings in ( ) are CFM Sq. Ft. OPTION: PNEUMATIC ACTUATOR
LOCKOUT: 1/2° INTERVALS
Damper Leakage Test based on ANSI/AMCA Standard 500-D-07, Ref. Fig 5.6 BLADE OPENS: CCW
Pressure Drop Test based on AMCA Standard 500-D-98, Ref. Fig 5.3 OPEN/CLOSE TORQUE: 1000 in-lb RECOMMENDED MIN
NOTE: All fittings with standard Fab-Tech
1.0 connections include gaskets and clamps or
hardware as required for installation.
16
Pressure Drop (in. wg)
10" STD
24
5" STD
36 "D"
0.1
0.01
19.26"
Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®
33 CONTROL DEVICES
16"-48" High Value Heavy Duty Industrial Damper (HVD)
SPECIFICATIONS
BODY: COATED 12GA STAINLESS STEEL
BODY LENGTH: 10"
COATING: PERMASHIELD FLUOROPOLYMER
BARRIER COATING
JOINING SYSTEM: STITCH WELDED COATED BLACK
IRON VAN STONE RINGS
OPTION: CUSTOM HOLE PATTERN
OPTION: STITCH WELDED STAINLESS STEEL
VAN STONE RINGS
MOUNTING HOLES: STRADDLE VERTICAL
CENTERLINE
BLADE: 1/4" COATED STAINLESS STEEL
BLADE STOPS: WELDED W/ VITON BLADE SEAL
AXLES: DUAL SHAFT 1.38Ø STAINLESS STEEL
AXLE SEALS: LIQUID TIGHT
SLEEVE BEARINGS: THERMOPLASTIC
ACTUATOR: MANUAL LEVER
OPTION: MANUAL GEAR BOX W/ LOCK OUT
OPTION: CUSTOM ACTUATOR MOUNTING KIT
OPTION: ELECTRIC ACTUATOR
OPTION: PNEUMATIC ACTUATOR
LOCKOUT: 1/2° INTERVALS
BLADE OPENS: CCW
OPEN/CLOSE TORQUE: 1000 in-lb RECOMMENDED MIN
NOTE: All fittings with standard Fab-Tech
connections include gaskets and clamps or
hardware as required for installation.
10" STD
5" STD
"D"
19-1/4"
Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®
CONTROL DEVICES 34
36"-48" AMCA High Value Heavy Duty Industrial Damper
10" STD
24
"D" 5" STD
36
0.1
0.01
0.001
100 1000 10000 LOCKOUT
Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®
35 CONTROL DEVICES
50" & Larger Reinforced Heavy Duty Industrial Damper
SPECIFICATIONS
BODY: COATED 1/4" STAINLESS STEEL
OPTION: AVAIL TO 120" DIA W/ ENGINEERING REVIEW
BODY LENGTH: 10"
COATING: PERMASHIELD FLUOROPOLYMER
BARRIER COATING
JOINING SYSTEM: FULLY WELDED STAINLESS
STEEL VAN STONE RINGS
OPTION: CUSTOM HOLE PATTERN
MOUNTING HOLES: STRADDLE VERTICLE
CENTERLINE
BLADE: 3/8" COATED REINFORCED
STAINLESS STEEL
BLADE STOPS: WELDED
AXLES: DUAL SHAFT 1.85Ø STAINLESS STEEL
AXLE SEALS: LIQUID TIGHT
SLEEVE BEARINGS: THERMOPLASTIC
ACTUATOR: GEAR ACTUATOR W/ LOCK OUT
OPTION: CUSTOM ACTUATOR MOUNTING KIT
OPTION: ELECTRIC ACTUATOR
OPTION: PNEUMATIC ACTUATOR
PNEUMATIC ACTUATED DAMPERS
HYTORK ACTUATOR STANDARD
XL45 - UP TO 20"
XL280 - 21" TO 48"
XL425 - 49" TO 94"
"D"
BLADE STOP
Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®
CONTROL DEVICES 36
24" - 84" Ultra Series Industrial Damper
SPECIFICATIONS
BODY: COATED 24"-40" DIA. 10GA STAINLESS STEEL
COATED 42"-84" DIA. 1/4" STAINLESS STEEL
OPTION: AVAIL TO 120" DIA W/ ENGINEERING REVIEW
BODY LENGTH: 10"
COATING: PERMASHIELD FLUOROPOLYMER
BARRIER COATING
JOINING SYSTEM: FULLY WELDED STAINLESS
STEEL VAN STONE RINGS
OPTION: CUSTOM HOLE PATTERN
MOUNTING HOLES: STRADDLE VERTICAL
CENTERLINE
BLADE: COATED REINFORCED
24"-58" DIA. 1/4" STAINLESS STEEL
60"-84" DIA. 3/8" STAINLESS STEEL
BLADE STOPS: WELDED
AXLES: 24"-44" DIA. DUAL SHAFT 1.20Ø STAINLESS STEEL
46"-58" DIA. DUAL SHAFT 1.85Ø STAINLESS STEEL
60" DIA. & UP DUAL SHAFT 2.45Ø STAINLESS STEEL
AXLE SEALS: LIQUID TIGHT
SLEEVE BEARINGS: BRONZE
ACTUATOR: STANDARD ROTORK HIGH SPEED
SI-1-Q SERIES INTERFACE
OPTION: CUSTOM ACTUATOR MOUNTING KIT
OPTION: ELECTRIC ACTUATOR
OPTION: PNEUMATIC ACTUATOR
LOCKOUT: 1/2° INTERVALS
BLADE OPENS: CCW
10"
NOTE: All fittings with standard Fab-Tech STD
connections include gaskets and clamps or
5"
hardware as required for installation. STD
"D"
BLADE STOP
Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®
37 CONTROL DEVICES
2" & 3" EZ Blastgate
NOTE
All fittings with standard Fab-Tech connections
include gaskets and clamps or hardware as
required for installation.
SPECIFICATIONS
Stainless steel frame material.
Blade lockout system.
"L" 8.5"
"D" 8.5"
"D" 8.5"
"L"
Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®
CONTROL DEVICES 38
4"-36" Horizontal Run Isolation Blastgate
NOTE
All fittings with standard Fab-Tech
connections include gaskets and WITH JOINT SYSTEM
clamps or hardware as required for EZ CLAMP 4" - 14"
installation.
SS CAST RING 4" - 14"
SPECIFICATIONS BI ANGLE RING 4" - 36"
Stainless steel frame material. SS ANGLE RING 16" - 36"
Blade lockout system.
UPPER ANGLE
BODY RING
STAINLESS
STEEL BLADE
PTFE WIPER
( TYP BOTH SIDES
LOWER OF BLADE )
BODY 8"
STD
"D"
BLADE
"L1" LOCKOUT
( SEE CHART ) (STD)
Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®
39 CONTROL DEVICES
16"-36" Horizontal Run Actuated Isolation Blastgate
NOTE
All fittings with standard Fab-Tech
connections include gaskets and
clamps or hardware as required for
installation.
SPECIFICATIONS
Stainless steel frame material.
Blade lockout system.
Exterior position indicator.
OPTIONS
Bellows enclosed lead screw for RING TYPES
additional corrosion resistance BI ANGLE RING 16" - 36"
( adds to L1 length ) SS ANGLE RING 16" - 36"
CHAIN
WHEEL
"L1" ACTUATOR
2 x "D" + 30"
SINGLE
BLADE
D1 D2
"D"
"L2" 18"
"D" + 12.5"
REV: 12/01/17 CAT039EA
Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®
CONTROL DEVICES 40
38" & Larger Horizontal Run Isolation Blastgate
NOTE
All fittings with standard Fab-Tech connections include gaskets and
clamps or hardware as required for installation.
Blastgates 86" diameter and larger subject to engineering review and approval.
SPECIFICATIONS
Stainless steel body, rings and blade. WITH JOINT SYSTEM
Blade lockout system.
BI ANGLE RING 38" - 100"
SS ANGLE RING 16" - 120"
ANGLE
UPPER BODY COLLAR RING
PTFE WIPER
( TYP BOTH SIDES
SPACER OF BLADE)
BLADE
BLADE 8"
LOWER BODY COLLAR STD
LOCKOUT
(STD)
BLADE
"D"
"L1"
( SEE CHART )
Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®
41 CONTROL DEVICES
38" & Larger Horizontal Run Actuated Isolation Blastgate
NOTE
All fittings with standard Fab-Tech connections include gaskets and
clamps or hardware as required for installation.
Blastgates 90" diameter and larger subject to engineering review and approval.
SPECIFICATIONS
Stainless steel body, rings and blade.
Blade lockout system. RING TYPES
Exterior position indicator. BI ANGLE RING 38" - 100"
OPTIONS SS ANGLE RING 38" - 120"
Bellows enclosed lead screw for additional
corrosion resistance ( adds to L1 length )
* Blastgates 90" diameter and larger subject to engineering review and approval.
CHAIN
WHEEL
"L1" ACTUATOR
2 x "D" + 30"
D1 D2
"D"
"L2" 18"
"D" + 12.5"
Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®
CONTROL DEVICES 42
4"-36" Vertical Run Isolation Blastgate
NOTE
All fittings with standard Fab-Tech connections include gaskets
and clamps or hardware as required for installation.
SPECIFICATIONS
Stainless steel body, rings and blade.
Blade lockout system.
"D"
STAINLESS
STEEL BLADE
"L1"
( SEE CHART )
ANGLE
PTFE WIPER RING
( TYP BOTH SIDES
OF BLADE )
UPPER
BODY
"L2"
15° ( SEE CHART )
LOWER
BODY
Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®
43 CONTROL DEVICES
16"-36" Vertical Run Actuated Isolation Blastgate
NOTE
All fittings with standard Fab-Tech connections include gaskets
and clamps or hardware as required for installation.
SPECIFICATIONS
Stainless steel frame material.
Blade lockout system.
Exterior position indicator.
OPTIONS
Bellows enclosed lead screw for additional
corrosion resistance ( adds to L1 length )
RING TYPES
BI ANGLE RING 16" - 36"
SS ANGLE RING 16" - 36"
"L1"
2 x "D" + 30"
"L3"
"D" + 12.5"
"D"
"D1"
24"
CHAIN
WHEEL
ACTUATOR
"D2"
Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®
CONTROL DEVICES 44
38" & Larger Vertical Run Isolation Blastgate
NOTE
All fittings with standard Fab-Tech connections include gaskets
and clamps or hardware as required for installation.
Blastgates 86" diameter and larger are subject to engineering
review and approval.
SPECIFICATIONS
Stainless steel body, rings and blade.
Blade lockout system.
Vertical run blastgates greater than 84" require engineering
review and approval.
BLADE "D"
LOCKOUT WITH JOINT SYSTEM
(STD)
BI ANGLE RING 38" - 100"
SS ANGLE RING 38" - 120"
BLADE
BLADE
PTFE WIPER
( TYP BOTH SIDES "L1"
OF BLADE) ANGLE
RING ( SEE CHART )
COLLAR
10° BLADE "L2"
UPPER
LOWER BODY BODY ( SEE CHART )
COLLAR
SPACER
Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®
45 CONTROL DEVICES
38" & Larger Vertical Run Actuated Isolation Blastgate
NOTE
All fittings with standard Fab-Tech connections include gaskets
and clamps or hardware as required for installation.
Blastgates 90" diameter and larger are subject to engineering
review and approval.
SPECIFICATIONS
Stainless steel body, rings and blade.
Blade lockout system.
Exterior position indicator.
OPTIONS
Bellows enclosed lead screw for additional
corrosion resistance ( adds to L1 length )
RING TYPES
BI ANGLE RING 38" - 100"
SS ANGLE RING 38" - 120"
"L1"
2 x "D" + 30"
"L3"
"D" + 12.5"
"D"
"D1"
24"
CHAIN
WHEEL
ACTUATOR
"D2"
DUCT DIA. OUTSIDE DIM BODY NO. OF BLADE
"D" "L1" BODY BLADE COLLAR BOLTS BLADES ANGLE
38" TO 64" 2"D" + 30" 10GA 12GA 12GA .38" 1 10°
66" TO 88" 2"D" + 30" 10GA 12GA 12GA .43" 1 10°
* Blastgates 90" diameter and larger are subject to engineering review and approval.
REV: 12/01/17 CAT045EA
Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®
ACCESSORIES 46
Product Guide
SIZE: 4"-120"
PAGE: 52
SIZE: 2" & 3" SIZE: 2" & 3" SIZE: 4" TO 14"
PAGE: 53 PAGE: 53 PAGE: 53
Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®
47 ACCESSORIES
Field Installed Nipple
DIE-CUT GASKET
NOTES
Refer to Fab-Tech's INSTALLATION AND
ASSEMBLY GUIDE for assembly instructions.
DUCT
PTFE DIE-CUT GASKET
STRAIGHT
JAM PIPE THREAD 1-1/2"
NUT
TAPER
PIPE THREAD
NIPPLE
Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®
ACCESSORIES 48
Field Installed Test Port
HEX NUT
TEST
PORT
NPT
HANDLE
SEAL
(REMOVABLE)
PART NO. DESCRIPTION MIN. HOST DUCT THRU HOLE REDRILL I.D. TAP HOLE
FTFI38TP 3/8" TEST PORT 2" DIA. DUCT MIN. 1/4" DIA. 3/8" MAX 1/16" NPT
FTFI34TP 3/4" TEST PORT 6" DIA. DUCT MIN. 1/2" DIA. 3/4" MAX 1/4" NPT
FTFI20TP 2" TEST PORT 12" DIA. DUCT MIN. 9/16" DIA. 1-3/4" MAX 3/8" NPT
SPECIFICATIONS
.75"
Nipple made of pure PVDF, seal made of Viton®
SEAL Stainless steel hex nut
Able to re-drill through hole to slightly larger hole or
drill and tap test port for female threads - thread O.D.
cannot exceed max re-drill diameter
DUCT Installs in duct as small as 2" diameter - provides
APPROX. liquid tight seal - does not compromise the integrity
1-3/4" of the duct interior coating
HEX NUT
NOTES
Refer to Fab-Tech's INSTALLATION AND
ASSEMBLY GUIDE for assembly instructions.
3/8" TEST PORT
The unique handle design of this test port allows it to
be installed quickly and easily in-the-field with common
tools and without system shutdown or disassembly.
FTFI38TP
FTFI34TP FTFI20TP
Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®
49 ACCESSORIES
Field Installed Saddle Tap
NOTES
All fittings with standard Fab-Tech connections include gaskets
and clamps or hardware as required for installation.
Refer to Fab-Tech's INSTALLATION AND ASSEMBLY GUIDE
for assembly instructions.
Straight tap standard - other tap styles available with engineering
review and approval.
Fab-Tech's PSP® saddle tap will allow a new branch to be
installed without shutting down the exhaust system.
WITH JOINT SYSTEM
EZ CLAMP 4" - 14"
HOST DUCT I.D., WALL SS CAST RING 4" - 14"
THICKNESS & MATERIAL TYPE
( REQUIRED INFORMATION ) BI ANGLE RING 4" - 100"
SS ANGLE RING 16" - 120"
FLUOROPOLYMER COATED
THREADED CAPS WELDED
TO PSP® SADDLE TAP
SECTION THROUGH DUCT - BOOT TAP
D1
45°
9"
STD 6"
STD
D1 6"
STD
Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®
ACCESSORIES 50
Field Installed Hot Tap
NOTES
All fittings with standard Fab-Tech connections include gaskets
and clamps or hardware as required for installation.
Refer to Fab-Tech's INSTALLATION AND ASSEMBLY GUIDE
for assembly instructions.
Only straight tap available for this tap configuration.
Fab-Tech's PSP® Field Installed Hot Tap
will allow a new branch to be installed in
an existing system without shutting down
the exhaust system.
Isolation box required for installation.
28
26
24 SECTION THROUGH DUCT - HOT TAP
22
20 6"
18 STD End Cap
16 D2 Host Duct
14
12
10
PTFE Gasket
D1
Backing Ring
Fluoropolymer Coated
Threaded Caps Welded Anchor Bolt
to Backing Ring
HOST DUCT I.D., PRESSURE
CLASS & MATERIAL TYPE
( REQUIRED INFORMATION )
Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®
51 ACCESSORIES
Cast Ring
DUCT DIA
THICKNESS
BOLT HOLE
# HOLES
BOLT
BOLT
SIZE
SIZE
DIA.
(W)
(H)
(T)
DUCT
PART NO. DESCRIPTION DIA. RING
W
WIDTH
RC04 STEEL CAST RING 4"
RC06 STEEL CAST RING 6"
RC08 STEEL CAST RING 8"
RC10 STEEL CAST RING 10"
RC12 STEEL CAST RING 12"
RC14 STEEL CAST RING 14”
DUCT
DIA
"D"
Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®
ACCESSORIES 52
Angle Ring
DUCT DIA
THICKNESS
BOLT HOLE
# HOLES
CIRCLE
WIDTH
BOLT
BOLT
SIZE
SIZE
DIA.
(W)
(T)
"D" "D"
4 1 7/16 5.31 4
6
6 7/16 7.50 6
1/8 3/8
8 1-1/4 x 9.50 8
8 11/16
10 11.50 10
12 13.81 12
12
14 15.81 14
16 17.63 16
16 BI ANGLE RING 4" - 100"
18 1-1/2 19.63 18
20 21.63 20
SS ANGLE RING 16" - 120"
22 20 23.88 22
24 25.88 24
26 27.88 26
24
28 29.88 28 NOTES:
30 31.88 30
28
32 33.88 32 Standard mounting hole locations for welded
34 35.88 34 (fixed) angle rings straddle the vertical centerline
3/16 32
36 37.88 36
38
2
40.38 38
unless otherwise specified.
36
40 42.38 40 Refer to chart for standard angle rings.
42 44.38 42
40 All fittings with standard Fab-Tech connections include
44 46.38 44
46
44
48.38 46 gaskets and clamps or hardware as required for
48 50.38 48 installation.
50 52.88 50
48
52 54.88 52 OPTIONS:
54 56.88 54
2-1/2 52
56 58.88 56 Custom hole pattern and orientation available.
58 60.88 58
56
60 62.88 60
62 64.88 62
60
64 9/16
x
66.88 64 W RING WIDTH
66 1/2 68.88 66
64 3/4
68 70.88 68 T RING THICKNESS
70 SLOT 72.88 70
68
72 74.88 72
74 76.88 74
72
76 78.88 76
78 3 80.88 78 W
76
80 82.88 80
82 84.88 82
80
84 86.88 84
86 89.38 86
84
88 91.38 88
90 1/4 93.38 90
88
92 95.38 92
94 97.38 94
92
96 100.38 96
98 102.38 98
96
100 104.38 100
102 106.38 102
100
104 108.38 104
106 110.38 106
104
108 4 112.38 108
110 114.38 110 DUCT
108 DIA
112 116.38 112
114
112
118.38 114 "D"
116 120.38 116
118 122.38 118
116
120 124.38 120
REV: 12/01/17 CAT052EA
Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®
53 ACCESSORIES
PSP-EZ™ Clamp Kit
CLAMP CLAMP
FASTENER NUT
DUCT DUCT
FLANGE FLANGE
CROSS SECTION OF
2" & 3" PSP-EZ™ JOINT
CLAMP
CLAMP
FLOATING FLOATING
BACKING BACKING
RING RING
Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®
SIZE: 3" TO 2" SIZE: 2" & 3" SIZE: 2" & 3"
PAGE: 55 PAGE: 56 PAGE: 56
ELBOW ELBOW ELBOW
90° 45° 30°
SIZE: 2" & 3" SIZE: 2" & 3" SIZE: 2" & 3"
PAGE: 56 PAGE: 57 PAGE: 57
ECCENTRIC CONCENTRIC VAN STONE TO
ADAPTER ADAPTER EZ FLANGE
ADAPTER
SIZE: 3" TO 2" SIZE: 3" TO 2" SIZE: 3" TO 2"
4" TO 2", 4" TO 3" 4" TO 2", 4" TO 3" 4" TO 2", 4" TO 3"
PAGE: 57 PAGE: 58 PAGE: 58
END CAP MICRO FIELD INSTALL
ADJUSTABLE STRAIGHT DUCT
DAMPER FLANGE
SIZE: 2" & 3" SIZE:2" & 3" SIZE: 2" & 3"
PAGE: 58 PAGE: 59 PAGE: 60
BLASTGATE
Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®
EZ Tee
"D2"
"L2"
"D1" "L3"
"L1"
EZ Reducing Tee
"D2"
"L2"
"L3"
"D1"
"L1"
PART NO. DESCRIPTION "D1" "D2" "L1" "L2" "L3"
03T02 3" LINE WITH 2" TEE 3" 2" 6.74" 3.37" 3.62"
All fittings with standard Fab-Tech connections include gaskets and clamps or hardware as required for installation.
Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®
"L3"
"D1"
"L1"
EZ Lateral
"L1"
"D2"
"D1" 45°
"L2" "L1"
90° EZ Elbow
"L"
"D"
"L"
PART NO. DESCRIPTION "D" "L" R
PZE02 2" 90º ELBOW 2" 3.12" 2"
PZE03 3" 90º ELBOW 3" 4.62" 3"
All fittings with standard Fab-Tech connections include gaskets and clamps or hardware as required for installation.
Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®
"D"
"L"
"L"
30° EZ Elbow
R
"D"
"L"
"L"
Eccentric EZ Reducer
"D2"
"D1" "L2"
"L1"
Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®
"D2"
"L1"
PART NO. DESCRIPTION "D1" "D2" "L1"
PCA32F 2" TO 3" CONCENTRIC 2" 3" 4.31"
PCA42F 2" TO 4" CONCENTRIC 2" 4" 3.94"
PCA43F 3" TO 4" CONCENTRIC 3" 4" 4.31"
All fittings with standard Fab-Tech connections include gaskets and clamps or hardware as required for installation.
"D2"
"D4"
"L1" BOLT CIRCLE DIA.
PART NO. DESCRIPTION "D1" "D2" "L1" "D3" O.D. "D4" DIA.
PCA32R 2" TO 3" ANGLE RING 2" 3" 4.25" 5.06" 4.31"
PCA42R 2" TO 4" ANGLE RING 2" 4" 3.88" 6.06" 5.31"
PCA43R 3" TO 4" ANGLE RING 3" 4" 4.25" 6.06" 5.31"
All fittings with standard Fab-Tech connections include gaskets and clamps or hardware as required for installation.
EZ End Cap
"D"
"L"
Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®
"L"
POSITION LOCK
ACTUATOR
THUMB WHEEL PLATE
FRICTION WHEEL
"D"
Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®
NOTES
All fittings with standard Fab-Tech connections include
gaskets and clamps or hardware as required for installation.
PermaShield fluoropolymer barrier coating on interior and exterior
surfaces.
Requires purchase of Pressing Wheel, Part #D0700 for installation.
The pressing wheel is used to press a bead around the duct to
complete the installation. Wheel fits Ridgid Pipe Cutter Model 3S.
Refer to Fab-Tech's INSTALLATION AND ASSEMBLY GUIDE
for assembly instructions.
"O" RING
PRESSED
AUXILIARY BEAD
FLANGE DUCT
"D"
"L1"
Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®
NOTE
All fittings with standard Fab-Tech connections include
gaskets and clamps or hardware as required for installation.
SPECIFICATIONS
Stainless steel frame material.
Blade lockout system.
"L" 8.5"
"D" 8.5"
"D" 8.5"
"L"
Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®
PAGE: 70
PAGE: 69
Duct
PAGE: 67
PAGE: 74 PAGE: 75
Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®
DUCT
"D"
"L"
FAB-TECH
FLANGE
CLAMP
EZ DUCT
OR ADAPTER
Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®
NOTES
All fittings with standard Fab-Tech connections include
gaskets and clamps or hardware as required for installation.
Refer to Fab-Tech's INSTALLATION AND ASSEMBLY GUIDE
for assembly instructions.
PermaShield fluoropolymer barrier coating on inside surface
and flange faces.
KF Adapters are only available for 2" Fab-Tech Flange
connection.
"L1"
KF 25 KF 40 KF 50
Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®
NOTES
All fittings with standard Fab-Tech connections include
gaskets and clamps or hardware as required for installation.
Refer to Fab-Tech's INSTALLATION AND ASSEMBLY GUIDE
for assembly instructions.
PermaShield fluoropolymer barrier coating on inside surface
and flange face.
NPT nipples are not covered under warranty other than for
defects in manufacture. NPT threads are not coated and
since the threads could possibly come in direct contact with
corrosive fumes and fluids, Fab-Tech offers only a limited
warranty for these parts. Depending on the specific
application, NPT adapters should fall into the classification
of consumable parts.
"L1"
"L1"
"L1" "L1"
"L1"
FTN15
FTN02
FTN03
FTN04
USED WITH 4" PSP-EZ™ TAP
Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®
NOTES
All fittings with standard Fab-Tech connections include
gaskets and clamps or hardware as required for installation.
Refer to Fab-Tech's INSTALLATION AND ASSEMBLY GUIDE
for assembly instructions.
PermaShield fluoropolymer barrier coating on flange face.
NPT nipples are not covered under warranty other than for
defects in manufacture. NPT threads are not coated and
since the threads could possibly come in direct contact with
corrosive fumes and fluids, Fab-Tech offers only a limited
warranty for these parts. Depending on the specific
application, NPT adapters should fall into the classification
of consumable parts.
"L1"
"L1" FTF34
FTF01 FTF15 FTF02
Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®
NOTES
All fittings with standard Fab-Tech connections include
gaskets and clamps or hardware as required for installation.
Refer to Fab-Tech's INSTALLATION AND ASSEMBLY GUIDE
for assembly instructions.
PermaShield fluoropolymer barrier coating on flange face.
SWAGELOK® Adapters are not covered under warranty other
than for defects in manufacture. SWAGELOK® threads are not
coated and since the threads could possibly come in direct
contact with corrosive fumes and fluids, Fab-Tech offers only a
limited warranty for these parts. Depending on the specific
application, SWAGELOK® adapters should fall into the
classification of consumable parts.
"L1" "L1"
"L1"
"D"
"L1"
FTS34
Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®
"D" "D"
"L1" "L1"
GASKET GASKET
FTPT2 FTPT3
VARIES ACCORDING TO
DIAMETER OF DUCT
(ADJUST AS NEEDED)
FAB-TECH
FLANGE
CLAMP
PITOT
ADAPTER
GASKET
"O" RING
SPLIT FLANGE MOUNTING KIT
DWYER #A-158
ALIGN PITOT TUBE DWYER PITOT TUBE
TO CENTER OF DUCT DWYER #160-8 TO #160-60
BY ADJUSTING TO FROM: DWYER INSTRUMENTS
MARKINGS ON TUBE www.dwyer-inst.com
Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®
NOTES
All fittings with standard Fab-Tech connections include
gaskets and clamps or hardware as required for installation.
Refer to Fab-Tech's INSTALLATION AND ASSEMBLY GUIDE
for assembly instructions.
PermaShield fluoropolymer barrier coating on flange face and
o-ring surfaces.
1" NPT
1" NPT
"L1" "L1"
"D"
"D"
WATER SUPPLY
CONNECTION
GASKET
CLAMP
FAB-TECH
FLANGE
"O" RING
(SECONDARY SEAL
AND TO HOLD
DUCT BAG IN PLACE)
"D"
Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®
NOTES
All fittings with standard Fab-Tech connections include
gaskets and clamps or hardware as required for installation.
Refer to Fab-Tech's INSTALLATION AND ASSEMBLY GUIDE
for assembly instructions.
PermaShield fluoropolymer barrier coating on inside surface
and flange faces.
Requires Hydraulic Punch & Swage Kit (TPSO2) to
install - check accessories section.
Requires disassembly of duct to install this fitting.
GASKET
DUCT
"L1" (10" DIA MIN)
LOCKING
RING
"D"
"D"
Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®
INTERIOR SADDLE
2"
STD
PTFE GASKET
Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®
RECTANGULAR DUCT 72
Product Guide
PAGE: 74 PAGE: 74
STRAIGHT DUCT WITH STRAIGHT DUCT WITH STRAIGHT DUCT WITH
RECTANGULAR RECTANGULAR RECTANGULAR
BOOT TAP CONICAL TAP LATERAL TAP
PAGE: 81
Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®
73 RECTANGULAR DUCT
Mounting Flange Standards
CENTERLINE TO CENTERLINE
3” TO 4”
X
ANGLE IRON
MOUNTING
3” TO 4” FLANGE X
DUCT
CENTERLINE DEPTH
TO
CENTERLINE
NOTES
Flange material is stainless steel.
The number of holes for the bolt hole pattern is determined from the
duct width and depth. Hole to hole distance will be calculated to be
between 3" to 4". Oblong holes are punched along the flange centerline.
Duct width or depth of 98" and larger requires engineering review.
Interior stiffeners ( 1” SCH40 pipe ) are welded between duct sides 50" wide
or greater. Separate offset stiffeners are used when both duct width
and depth are 50" or greater.
Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®
RECTANGULAR DUCT 74
Straight Duct
"X"
INTERIOR STIFFENER
"Y"
NOTE
"L1"
All fittings with standard Fab-Tech connections include MAX. 48-1/4"
gaskets and clamps or hardware as required for installation.
OPTIONS
Custom lengths available. LONGER THAN STANDARD LENGTHS AND/OR HIGHER
Raw end available. SYSTEM PRESSURES MAY REQUIRE ADDITIONAL
STIFFENERS PER SMACNA, CONTACT FAB-TECH FOR
Duct width or depth of 98" and larger requires SPECIFIC GUIDELINES.
Fab-Tech engineering review and approval.
An interior stiffener ( 1" SCH40 pipe ) is added at the
midpoint of the flange for duct width or depth
of 50" and greater.
LONGER THAN STANDARD LENGTHS AND/OR HIGHER SYSTEM MIN 4" "TX"
PRESSURES MAY REQUIRE ADDITIONAL STIFFENERS PER MIN 4"
SMACNA, CONTACT FAB-TECH FOR SPECIFIC GUIDELINES.
"L4" "L3"
"L4" "L4" "L4"
"Y" "TY"
Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®
75 RECTANGULAR DUCT
Straight Duct with Rectangular Boot Tap
NOTE
All fittings with standard Fab-Tech connections include gaskets and
clamps or hardware as required for installation.
OPTIONS
Custom lengths available.
Raw end available.
Duct width or depth of 98" and larger requires 6” 45°
Fab-Tech engineering review and approval. STD
An interior stiffener ( 1" SCH40 pipe ) is added at the
midpoint of the flange for duct width or depth of 50"
and greater.
"L4" "L3"
"L4" "L4" "L4"
"TY"
"Y"
"L4" "L3"
"L4" "L4" "L4"
"Y" "TY"
Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®
RECTANGULAR DUCT 76
Straight Duct with Rectangular Lateral Tap
NOTE MIN 4"
All fittings with standard Fab-Tech connections include gaskets
and clamps or hardware as required for installation.
OPTIONS
Custom lengths available.
Raw end available.
Duct width or depth of 98" and larger requires Fab-Tech
engineering review and approval.
An interior stiffener ( 1" SCH40 pipe ) is added at the midpoint of
the flange for duct width or depth of 50" and greater.
"Y" "TY"
"Y"
Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®
77 RECTANGULAR DUCT
Straight Duct with Multiple Taps
6" STD
"TX"
1" MIN 6" STD
MIN 6" "TX" "TX" "TX" "R" "DØ"
4" 4"
"TX"
MIN MIN
"L2" "L2"
45°
STRAIGHT
"L3" TAP
4"
SHOE "L3" MIN
TAP
"L3" CONICAL TAP
"L3" ROUND TAP
"L3" 45° LATERAL TAP
"L1" MAX. 48-1/4"
"X"
Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®
RECTANGULAR DUCT 78
90°, 60°, 45°, 30° or Custom Elbow
"N"
"L1"
NOTE
All fittings with standard Fab-Tech connections include gaskets and
clamps or hardware as required for installation.
"X" OPTIONS
Raw end available.
Duct width or depth of 98" and larger requires Fab-Tech engineering
review and approval.
90° RADIAL An interior stiffener ( 1" SCH40 pipe ) is added at the midpoint of the
ELBOW flange for duct width or depth of 50" and greater.
"L2"
"N"
"Y"
45° MITERED
ELBOW
Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®
79 RECTANGULAR DUCT
Concentric Transition
"X"
"T1" "L1"
"T2" "Y"
FOR ECCENTRIC RECTANGULAR
TO RECTANGULAR FITTING, USE
THE CUSTOM FITTING ORDER
SHEET.
NOTE
All fittings with standard Fab-Tech connections include gaskets and
clamps or hardware as required for installation.
OPTIONS
Raw end available.
Duct width or depth of 98" and larger requires Fab-Tech engineering
review and approval.
An interior stiffener ( 1" SCH40 pipe ) is added at the midpoint of the
flange for duct width or depth of 50" and greater.
Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®
RECTANGULAR DUCT 80
Vertical Offset
CENTER OF "Y"
TO CENTER OF "L2"
OFFSET
"Y"
"X" "L1"
NOTE
All fittings with standard Fab-Tech connections include gaskets and
clamps or hardware as required for installation.
OPTIONS
Raw end available.
Duct width or depth of 98" and larger requires Fab-Tech engineering
review and approval.
An interior stiffener ( 1" SCH40 pipe ) is added at the midpoint of the
flange for duct width or depth of 50" and greater.
Horizontal Offset
CENTER OF "X"
TO CENTER OF "L2" "L1"
OFFSET
NOTE
All fittings with standard Fab-Tech connections
include gaskets and clamps or hardware as
required for installation.
"X"
OPTIONS
Raw end available.
Duct width or depth of 98" and larger requires
Fab-Tech engineering review and approval.
An interior stiffener ( 1" SCH40 pipe ) is added at
the midpoint of the flange for duct width or depth "Y"
of 50" and greater.
Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®
81 RECTANGULAR DUCT
Double Offset
CENTER OF "X"
TO CENTER OF "L3"
OFFSET
CENTER OF "Y"
TO CENTER OF "L2"
OFFSET
"Y"
"X" "L1"
NOTE
All fittings with standard Fab-Tech connections include gaskets and
clamps or hardware as required for installation.
OPTIONS
Raw end available.
Duct width or depth of 98" and larger requires Fab-Tech engineering
review and approval.
An interior stiffener ( 1" SCH40 pipe ) is added at the midpoint of the
flange for duct width or depth of 50" and greater.
End Cap
STAINLESS STEEL
PLATE WELDED
TO FLANGE
"Y"
"X"
NOTE
All fittings with standard Fab-Tech connections include gaskets and
clamps or hardware as required for installation.
OPTIONS
Flange material will be stainless steel unless other material is specified.
Duct width or depth of 98" and larger requires Fab-Tech engineering
review and approval.
A stiffener ( angle material matching the frame ) is added at the flange midpoint or where aesthetically
pleasing for duct width or depth of 50" and greater ( as required to meet maximum 4' spacing ).
Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®
RECTANGULAR DUCT 82
Product Guide
INDUSTRIAL INDUSTRIAL
RECTANGULAR RECTANGULAR RECTANGULAR
PARALLEL BLADE OPPOSED BLADE
CONTROL CONTROL DAMPER CONTROL DAMPER
DEVICES
PAGE: 83 PAGE: 83
INDUSTRIAL HEAVY DUTY HEAVY DUTY
RECTANGULAR RECTANGULAR RECTANGULAR
INDUSTRIAL PARALLEL BLADE OPPOSED BLADE
BACKDRAFT CONTROL DAMPER CONTROL DAMPER
DAMPER
PAGE: 84 PAGE: 85 PAGE: 85
HORIZONTAL VERTICAL
BLASTGATE BLASTGATE
PAGE: 86 PAGE: 86
Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®
83 RECTANGULAR DUCT
Industrial Rectangular Parallel Blade
Control Damper
NOTE
All fittings with standard Fab-Tech connections "L1" 8"
include gaskets and clamps or hardware as STD
required for installation.
SPECIFICATIONS
Frame 8" standard length with 2" flanges.
Mounting holes (.562" x .750" slot)
located between 3" to 4" on center.
Blades - 10 GA stainless steel.
Axles - .50" diameter stainless steel.
Liquid tight shaft seals.
Linkage located outside the "L2"
airstream - 10 GA stainless steel
twin drive as required.
Quadrant plates - 10 GA stainless
steel.
Quadrant lever - .25" stainless steel.
Full open / full close lockouts.
PTFE frame seals.
OPTIONS
Actuator mounting kits.
Blank mounting kit ( plate & shaft adapter ) for
customer supplied actuator.
Pneumatic / electric actuator.
Gear drive with locking damper shaft. FOR "L1" OR "L2" LONGER THAN 36"
HEAVY DUTY DAMPER IS REQUIRED
Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®
RECTANGULAR DUCT 84
Industrial Rectangular Backdraft Damper
NOTE
"L1" 8"
All fittings with standard Fab-Tech STD
connections include gaskets and
clamps or hardware as required
for installation.
SPECIFICATIONS
10 GA stainless steel frame
8" std length with 2" flanges
center support as required.
Flange mounting holes "L2"
( .562" X .750" slot ) equal to
or less than 4" on center.
14 GA stainless steel blades.
.50" diameter stainless steel
axles.
Liquid tight shaft seals.
All linkages 10 GA stainless
steel outside airstream.
Manual adjustable COUNTERWEIGHT
counterweights.
PTFE frame seals. CENTER SUPPORT REQUIRED FOR
BLADES LONGER THAN 36" ( "L1" )
Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®
85 RECTANGULAR DUCT
Heavy Duty Rectangular Parallel Blade
Control Damper
NOTE
All fittings with standard Fab-Tech connections 10"
"L1"
include gaskets and clamps or hardware as STD
required for installation.
SPECIFICATIONS
Frame 10" standard length with 2" flanges.
Mounting holes (.562" x .750" slot)
located between 3" to 4" on center.
Blades - 10 GA stainless steel.
Axles - 1.38" diameter stainless steel.
Liquid tight shaft seals.
Linkage located outside the "L2"
airstream - 10 GA stainless steel
twin drive as required.
Quadrant plates - 10 GA stainless
steel.
Quadrant lever - .25" stainless steel.
Full open / full close lockouts.
PTFE frame seals.
OPTIONS
Actuator mounting kits.
Blank mounting kit ( plate & shaft adapter ) for
customer supplied actuator.
Pneumatic / electric actuator.
Gear drive with locking damper shaft.
CENTER SUPPORT W/ CENTER LINKAGE
REQUIRED FOR BLADES LONGER THAN 36" ("L1").
Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®
RECTANGULAR DUCT 86
Horizontal Blastgate
BLADE
8"
BLADE STD
LOCKOUT
(STD) PTFE WIPER
( TYP BOTH
SIDES OF
BLADE)
"L2"
COLLAR
BODY
SPACER
"L1"
CENTER SUPPORT REQUIRED FOR BLADES LONGER THAN 36" ( "L1" )
SPECIFICATIONS
Stainless steel body, rings and blades.
Blade lockout system.
All fittings with standard Fab-Tech connections include gaskets
and clamps or hardware as required for installation.
Vertical Blastgate
BLADE 8"
STD
BLADE
LOCKOUT
(STD) PTFE WIPER
( TYP BOTH
SIDES OF
BLADE)
"L2"
COLLAR
BODY
SPACER
"L1"
CENTER SUPPORT REQUIRED FOR BLADES LONGER THAN 36" ( "L1" )
SPECIFICATIONS
Stainless steel body, rings and blades.
Blade lockout system.
All fittings with standard Fab-Tech connections include gaskets
and clamps or hardware as required for installation.
REV: 12/01/17 CAT086EA