PermaShield Pipe

Stainless Steel Corrosive Fume


Exhaust Systems With
PermaShield Fluoropolymer
Barrier Coating
C

PRODUCT CATALOG
Catalog 10/12.8

Fab-Tech, Inc.
A Critical Process Systems Group Company
®

CONTENTS PRODUCT CATALOG 2


H
T
STANDARDS
W PermaShield Pipe (PSP®) Ductwork Fabrication Standards 4
Straight Duct Gauge 5
Ring Mechanical Specifications 6
DUCT
DIA
"D"
Ring Mechanical Specifications 7
PSP-EZ™ Clamp Mechanical Specifications 8

DUCT & FITTINGS PRODUCT GUIDE 9


Straight Duct 10
Straight Duct with Fab-Tech Flange ( Use with 2" & 3" PSP-EZ™ Fittings ) 11
Straight Duct with Straight Tap 12
Straight Duct with Conical Tap 13
Straight Duct with Shoe Tap 14
Straight Duct with Lateral Tap 15
Straight Duct with Multiple Taps 16
Gored Elbow 17
Reducer 18
Offset 19
End Cap 20
Concentric Round to Rectangular Transition 21
Custom Fitting 22

CONTROL DEVICES PRODUCT GUIDE 23


4" - 12" Wafer Isolation Damper 24
2" & 3" Micro-Adjustable EZ Damper 25
4" - 14" Industrial Balancing Damper 26
4" Industrial Isolation Damper 27
6" - 14" Industrial Isolation Damper 28
6" - 14" AMCA Industrial Isolation Damper 29
4" - 14" Industrial Short Damper - Isolation & Balancing 30
AMCA Damper Test Setup 31
16" - 34" AMCA High Value Heavy Duty Industrial Damper 32
16" - 48" High Value Heavy Duty Industrial Damper (HVD) 33
36" - 48" AMCA High Value Heavy Duty Industrial Damper 34
50" & Larger Reinforced Heavy Duty Industrial Damper 35
24" - 84" Ultra Series Industrial Damper 36
2" & 3" EZ Blastgate 37
4" - 36" Horizontal Run Isolation Blastgate 38
16" - 36" Horizontal Run Actuated Isolation Blastgate 39
38" & Larger Horizontal Run Isolation Blastgate 40
38" & Larger Horizontal Run Actuated Isolation Blastgate 41
4" - 36" Vertical Run Isolation Blastgate 42
16" - 36" Vertical Run Actuated Isolation Blastgate 43
38" & Larger Vertical Run Isolation Blastgate 44
38" & Larger Vertical Run Actuated Isolation Blastgate 45

ACCESSORIES PRODUCT GUIDE 46


Field Installed Nipple 47
Field Installed Nipple / Test Port 48
Field Installed Saddle Tap 49
Field Installed Hot Tap 50
Cast Ring 51
Angle Ring 52
PSP-EZ™ Clamp Kit 53

REV: 12/01/17 CAT002EA

Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®

3 CONTENTS PRODUCT CATALOG


EZ FITTINGS PRODUCT GUIDE 54
EZ Straight Duct, Tee and Reducing Tee 55
EZ Double Tee, Lateral, 90° Elbow 56
EZ 45° Elbow, 30° Elbow, Eccentric Reducer 57
EZ Concentric Reducer, Angle Ring to EZ Reducer, End Cap 58
Micro-Adjustable EZ Damper 59
Field Installed Straight Duct EZ Flange 60
EZ Blastgate 61

FAB-TECH FLANGE SYSTEM PRODUCT GUIDE 62


Fab-Tech Flange 63
KF Flange Adapter 64
NPT Male Nipple Adapter 65
NPT Female Coupler Adapter 66
SWAGELOK® Adapter 67
Dwyer Pitot Adapter 68
Sprinkler Adapter 69
Field Installed 2" Fab-Tech Flange 70
Field Installed Fab-Tech Flange Saddle Tap 71

RECTANGULAR DUCT PRODUCT GUIDE 72


Mounting Flange Standards 73
Straight Duct 74
Straight Duct with Straight Rectangular Tap 74
Straight Duct with Rectangular Boot Tap 75
Straight Duct with Rectangular Conical Tap 75
Straight Duct with Rectangular Lateral Tap 76
Straight Duct with Round Tap 76
Straight Duct with Multiple Taps 77
90°, 60°, 45°, 30° or Custom Elbow 78
90°, 60°, 45°, 30° or Custom Mitered Elbow 78
Concentric Transition 79
Concentric Rectangular to Round Transition 79
Vertical Offset 80
Horizontal Offset 80
Double Offset 81
End Cap 81

RECTANGULAR CONTROL DEVICES PRODUCT GUIDE 82


Industrial Parallel Blade Control Damper 83
Industrial Opposed Blade Control Damper 83
Industrial Backdraft Damper 84
Heavy Duty Parallel Blade Control Damper 85
Heavy Duty Opposed Blade Control Damper 85
Horizontal Blastgate 86
Vertical Blastgate 86

REV: 12/01/17 CAT003EA

Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®

STANDARDS 4
PermaShield Pipe (PSP®) Ductwork
Fabrication Standards

The Fab-Tech Ductwork Fabrication Standard Manual is designed to d. Testing shall be performed at the factory over the entire coated
aid you, our customer, in becoming acquainted with our fabrication surface inside and out (where applicable) and edges. The testing
practices. The manual is in strict accordance with the practices in the shall be performed with a DC spark tester used at 2500 volts.
latest S.M.A.C.N.A. manuals.
e. Delivery, Storage, and Handling:
1. Protection: Protection is factory applied to ends of
GENERAL ductwork to prevent end damage and prevent dirt and
moisture from entering ducts and fittings.
Codes and Standards
2. Delivery: Consignee must inspect shipment upon delivery
a. Ducts shall be listed for use without the necessity for internal fire
and note any and all damages and discrepancies on Bill of
protection sprinklers or any devices relied on to cut off air flow in the Lading and notify manufacturer within 24 hours.
event of fire by the following:
3. Storage: Coated ductwork should not be stored in an area
Factory Mutual Research Standard 4922 where it will have a chance to be damaged from traffic or
debris. All coated ductwork should be stored on cardboard,
Limitations and Requirements: Styrofoam or similar materials. Where possible, store inside
1. All ducts shall be interiorly furnished with a fluoropolymer and protect from dirt and debris. Where necessary to store
thermoplastic resin. The total interior coating thickness shall outside, store above ground and enclose with water proof
not exceed 16 mils (0.30 mm). Complete and uniform coating wrapping to protect from dirt and debris.
coverage is required. 4. Handling: If coating is scratched use appropriate protocol
2. This duct may be used for smoke removal in special to "spark test" (refer to Installation and Assembly Guide, Field
purpose areas when properly designed and sized. Sprinklers Modification section) and if spark is detected, contact
are not required. manufacturer for repair instruction.
3. The product shall be manufactured with identical resins as 5. Welding: Under no circumstances shall welding or a heat
tested, and according to the formulation on file with FMRC, source greater than 300°F (150°C) be allowed on the stainless
and shall meet all physical requirements of S.M.A.C.N.A. steel surface of the duct.
manual for Industrial Duct Construction Standards.
e. Duct Assembly shall be accomplished utilizing either companion
4. Vertical height of individual risers within the duct system rings or Fab-Tech's PSP-EZ™ clamp:
are not restricted, however, they shall not penetrate other fire
1. Companion rings are available as angle rings in sizes 4" thru
areas.
120” diameter or as cast rings in sizes 4” thru 14” diameter. The
5. The manufacturer shall determine the suitability of the duct minimum number of holes for flange connections is one hole for
systems for specific corrosive environments. each 4" of duct circumference to the next higher number.
6. If the process served by such duct system produces 2. PSP-EZ™ clamps are available in sizes 2" thru 14". The
flammable residue or a combustible fume source exceeding PSP-EZ™ band ring style of joining system shall provide a
1ft2 (0.09 m2) in area per inlet which can build up inside the minimum compression load to the gasket of 900 PSI.
duct, then internal sprinklers will be required.
f. Gasket Technology:
7. ASTM E-84 Standard Test Method for Surface Burning
1. Ring gasket material shall be PermaShield form in place,
Characteristics. Tested in flat sheet form at a 20 ga. (0.95 mm)
fully expanded 100% PTFE joint sealant.
thickness: Flame Spread 0, Smoke Density 20.
4"-30" diameter duct - .010" x .75" tape gasket
b. Fab-Tech's FM Global Approval ( 4922 ) extends the widest 32" diameter & up duct - 1/4" x 3/16" rope gasket
possible limits from 4" diameter ( 100mm ) up to and including 60" 2. PSP-EZ™ clamp gasket material shall be PermaShield form
diameter ( 1525mm ) duct and fittings. in place, fully expanded 100% PTFE tape or die cut gasket
(2"-3" diameter).
DUCTWORK
a. Base Metal shall be a series 300 Stainless Steel. Longitudinal
seams shall be fusion welded. Traverse seams shall be continuous
weld. All seams shall be smooth on the interior of duct.
b. Coating shall be PermaShield Fluoropolymer Barrier Coating and
shall be applied per Factory Mutual Research Corporation's Fab-Tech, Inc.
A Critical Process Systems Group Company
limitations and requirements.
c. Black Iron Rings shall be coated with PermaProtect, Black Iron
Ring Powder®. This heat and chip resistant coating is electro statically Visit our website at www.fabtechinc.com
applied and sintered to the substrate. Email address: sales@fabtechinc.com
Fab-Tech reserves the right
to change or modify specifications without notice.
PSP® and PSP-EZ™ are registered trademarks of Fab-Tech, Inc.

REV: 12/01/17 CAT004EA

Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®

5 STANDARDS
Straight Duct Gauge
MIN GAUGE FOR 4' DUCT MIN GAUGE FOR 8' DUCT
DUCT STD DUCT DUCT
DIA -6" -10" -14" -18" DUCT DIA DIA
"D" WG WG WG WG LENGTH "D" "D"
STD
4 4 -6" -10" -14" -18" DUCT 4
WG WG WG WG LENGTH
6 6 6
8 8 8
10 10 10
20
12 12 12
20 20
14 14 20 14
20
16 16 16
18 18 18
20 20
20 20 18 20
22 22 22
24 24 18 24
26 20 47.25 26 26
28 28 18 95.25 28
30 30 16 30
18
32 32 32
34 34 34
16
36 18 36 36
38 38 38
40 40 40
18
42 42 42
14
44 44 16 44
46 18 46 46
48 16 48 48
50 50 50
14
52 52 52
54 54 54
56 16 56 56
58 58 58
60 60 60
62 62 16 62
64 18 64 64
14
66 66 66
68 68 68
70 16 14 70 70
72 72 72
12
74 74 74
76 76 76
78 46.75 78 94.75 78
80 80 80
82 14 82 82
84 84 84
12
86 86 86
88 88 88
90 90 90
14
92 92 92
94 94 94
96 96 96
98 16 98 98
12
100 100 100
102 14 12 102 102
104 104 104
106 106 106
108 108 108
12
110 110 110
10GA
112 112 112
OR
114 48.25 114 96.25 114
12 12 GA
116 116 116
WITH
118 118 118
14 STIFFENER
120 120 120
REV: 12/01/17 CAT005EA

Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®

STANDARDS 6
Ring Mechanical Specifications

RING MATERIAL
ANGLE RING SPECIFICATIONS & GASKETS CAST RING SPECIFICATIONS

PTFE GASKET
DUCT DIA

DUCT DIA

STAINLESS

DUCT DIA
THICKNESS

THICKNESS
BOLT HOLE

BOLT HOLE
BLACK
STEEL
# HOLES

# HOLES
CIRCLE

CIRCLE
WxH

IRON

HEIGHT
WIDTH

WIDTH
BOLT

BOLT
BOLT

BOLT
SIZE

SIZE
SIZE

DIA.

SIZE

DIA.
(W)

(W)

(H)
(T)

(T)
"D" "D" "D"
4 1 7/16 5.31 4 4 5.31
6 6 7/16
6
1/8 7/16 3/8
7.50 6 SC 6
3/8
7.50
1-1/4 13/32 1/8 x
8 1-1/4 x 9.50 8 8 9.50

FLOAT
8 8 11/16
10 11/16 11.50 10 10 11.50
12 13.81 12 .01
12 x 12 9/16 13.81
14 15.81 14 .75 BI 1-1/2 1/2 3/16 12 x 1/2
16 17.63 16 TAPE 14 3/4 15.81
16

FLOAT
18 1-1/2 19.63 18 GAS09
20 21.63 20 SS KEY: SC STAINLESS CAST RING
22 20 23.88 22
24 25.88 24 FLOAT SS STAINLESS STEEL ANGLE RING
26 27.88 26 BI BLACK IRON ANGLE RING
24
28 29.88 28
30 31.88 30 Notes:
28
32 33.88 32 Duct 4" to 14" manufactured with cast rings
34 35.88 34 as standard. Duct 16” to 120" manufactured
3/16 32
36 37.88 36 with angle rings as standard.
2
38 40.38 38
40
36
42.38 40
Standard mounting hole locations for welded
42 44.38 42
angle rings (32" to 120") straddle the vertical
44
40
46.38 44
centerline unless otherwise specified.
46 48.38 46 Standard hardware provided for angle ring
44 applications are plated GRADE 5 fasteners.
48 50.38 48
50 52.88 50 Stainless steel hardware is not recommended.
48
52 54.88 52
54 56.88 54
2-1/2 52
56 58.88 56
58 60.88 58 Grade 5 Bolt Markings:
56
60 62.88 60
62 64.88 62 SS BI Torque Specifications:
60 9/16
64 66.88 64
STITCH WELDED
STITCH WELDED

66 x 68.88 66
Torque in at least 3 stages
1/2
64 3/4
68 70.88 68 Duct Bolt
70 SLOT 72.88 70 Dia. Size Ft lb In lb M kg
68 1/4
72 74.88 72 x 4"-10" 3/8" 36 432 5.0
74 76.88 74 3/16
72 12"-120" 1/2" 75 900 10.4
76 78.88 76
GAS03

78 3 80.88 78
76
80 82.88 80
82 84.88 82 Duct and fittings greater than 84" diameter
80 requires engineering review and approval.
84 86.88 84
86 89.38 86 Custom angle rings available on request.
84
88 91.38 88 See Installation and Assembly Guide for metric
90 1/4 93.38 90 duct size conversions.
88
92 95.38 92
94 97.38 94
92 PTFE GASKETS* FOR RING JOINTS
96 100.38 96
98 102.38 98
96 4"-30"Ø 32"-120"Ø
100 104.38 100
102 106.38 102 .01 X .75 TAPE & RECTANGULAR
100 P/N: GAS09 1/4" x 3/16" ROPE
104 108.38 104
106 110.38 106 3/4" P/N: GAS03
104
108 4 112.38 108
110 114.38 110 SS 1/4"
108
112 116.38 112
WELDED
FULLY

114 118.38 114 3/16"


112
116 120.38 116
* ADHESIVE ON ONE SIDE
118 122.38 118
116
120 124.38 120
REV: 12/01/17 CAT006EA

Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®

7 STANDARDS
Ring Mechanical Specifications

Cast Ring Angle Ring


STANDARD FOR DUCT 4" TO 14" BLACK IRON ANGLE RING 4" TO 100"
STAINLESS STEEL ANGLE RING 16" TO 120"
H HEIGHT (SEE RING SPEC CHART)
W WIDTH (SEE RING SPEC CHART)
T THICKNESS (SEE RING SPEC CHART)
T THICKNESS (SEE RING SPEC CHART)

RING
W RING
WIDTH W
WIDTH

DUCT
DIA DUCT
"D" DIA
"D"

STAINLESS STEEL ANGLE RING


CAST RING BLACK IRON OR
GRADE 5 STAINLESS STEEL GRADE 5
FASTENERS FASTENERS

DUCT PTFE DUCT DUCT PTFE DUCT


TAPE TAPE
GASKET GASKET
Floating Cast Ring Floating Angle Ring

ANGLE RING
BLACK IRON OR ANGLE RING
STAINLESS STEEL STAINLESS STEEL

PTFE
STITCH WELDS STITCH ROPE
WELD GASKET

FULL
DUCT PTFE ROPE GASKET DUCT WELD

Stitch Welded Angle Ring Welded Angle Ring


REV: 12/01/17 CAT007EA

Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®

STANDARDS 8
PSP-EZ™ Clamp Mechanical Specifications

CLAMP
DUCT DUCT GAUGE STRAIGHT BACKING
DIA. -6" Thru -18" DUCT RING DUCT DUCT
WG LENGTH
"D"
2 .035 TUBING
WELDED
3 .065 TUBING
4
6 4 FT
( 47.25" "D"
8 ACTUAL )
20 FLOATING
10
12
14

The PSP-EZ™ joining system is available for


standard PSP® duct from 2" to 14" in diameter.
The combination of half round backing rings
and the unique angled clamp band provides
excellent clamping force with the added
benefit of ease of installation.

Torque Specifications:
Duct Bolt Torque in at least
Diameter Size 3 stages
lb*ft lb*in kg*m
4",6" 1/4" 6.25 75 0.9
8",10",12",14" 5/16" 10 120 1.4

2" & 3" PSP-EZ™ CLAMP 4"-14" PSP-EZ™ CLAMP


CLAMP CLAMP

DUCT DUCT FLOATING FLOATING


FLANGE FLANGE BACKING BACKING
RING RING

DUCT DUCT DUCT DUCT

CROSS SECTION OF JOINT CROSS SECTION OF JOINT


REV: 12/01/17 CAT008EA

Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®

9 DUCT & FITTINGS


Product Guide
STRAIGHT DUCT STRAIGHT DUCT
WITH FAB-TECH
FLANGE
4" to 120" DUCT
SIZE: 4"-120" SIZE: 2", 3”
PAGE:10 PAGE: 11
STRAIGHT DUCT STRAIGHT DUCT STRAIGHT DUCT
WITH STRAIGHT WITH CONICAL WITH SHOE TAP
TAP TAP

SIZE: 6"-120" SIZE: 6"-120" SIZE: 6"-120"


PAGE:12 PAGE: 13 PAGE: 14
STRAIGHT DUCT STRAIGHT DUCT GORED ELBOW
WITH LATERAL WITH MULTIPLE 30°, 45°, 60°, 90°
TAP TAPS

SIZE: 6"-120" SIZE: 4"-120" SIZE: 4"-120"


PAGE: 15 PAGE: 16 PAGE: 17
CONCENTRIC ECCENTRIC OFFSET
REDUCER REDUCER

SIZE:6"-120" SIZE: 6"-120" SIZE: 4"-120"


PAGE: 18 PAGE: 18 PAGE: 19
END CAP CONCENTRIC ROUND CUSTOM FITTING
TO RECTANGULAR
TRANSITION
SIZE:
4"-120"
PAGE: 20 PAGE: 21 PAGE: 22

STRAIGHT DUCT STRAIGHT DUCT


WITH FAB-TECH
4" to 14" FLANGE
PSP-EZ™ CLAMP
SIZE: 4" TO 14" SIZE: 2", 3”
PAGE:10 PAGE: 11
STRAIGHT DUCT STRAIGHT DUCT STRAIGHT DUCT
WITH STRAIGHT WITH CONICAL WITH SHOE
TAP TAP TAP

SIZE: 4" TO 14" SIZE: 6" TO 14" SIZE: 6" TO 14"


PAGE: 12 PAGE: 13 PAGE: 14
STRAIGHT DUCT STRAIGHT DUCT GORED ELBOWS
WITH LATERAL WITH MULTIPLE 30°, 45°, 60°, 90°
TAP TAPS

SIZE: 4" TO 14" SIZE: 4" TO 14" SIZE: 4" TO 14"


PAGE: 15 PAGE: 16 PAGE: 17
CONCENTRIC ECCENTRIC OFFSET
REDUCER REDUCER

SIZE: 4" TO 14" SIZE: 4" TO 14" SIZE: 4" TO 14"


PAGE: 18 PAGE: 18 PAGE: 19
END CAP CONCENTRIC ROUND CUSTOM FITTING
TO RECTANGULAR
TRANSITION

SIZE: 4" TO 14"


PAGE: 20 PAGE: 21 PAGE: 22
REV: 12/01/17 CAT009EA

Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®

DUCT & FITTINGS 10


Straight Duct
MIN GAUGE
FOR 4' DUCT
DUCT MIN GAUGE WITH JOINT SYSTEM
DIA -6" -10" -14" -18" FOR 8' DUCT
"D" WG WG WG WG EZ CLAMP 4" - 14"
4 -6" -10" -14" -18"
SS CAST RING 4" - 14"
WG WG WG WG
6
8 BI ANGLE RING 4" - 100"
10 SS ANGLE RING 16" - 120"
20 20
12
20 20 20 OR A COMBINATION OF
14
20
16 JOINING SYSTEMS
18
20
20 18
22 OPTIONS:
24 18
26 20 Custom lengths available.
28 18 Duct greater than 84" diameter requires Engineering review and approval.
30 16 Refer to FAB-TECH FLANGE SYSTEM section for adapters, drains and
18 test ports.
32
34 See Duct Gauge chart in STANDARDS section for other duct pressures.
18 16
36 Raw end available.
38
40 NOTES:
18
42
14 All fittings with standard Fab-Tech connections include gaskets and clamps
44 16
46 18 or hardware as required for installation.
48 16 See INSTALLATION AND ASSEMBLY GUIDE for shortening 4" thru 22"
50 duct in the field.
14
52
54
56 16 LONGER THAN STANDARD LENGTHS AND/OR HIGHER SYSTEM PRESSURES
58 MAY REQUIRE ADDITIONAL STIFFENERS PER SMACNA, CONTACT FAB-TECH
FOR SPECIFIC GUIDELINES.
60
62 16
64 18
14
66
68
70 16 14
72
74 12 "D"
76
78
80
82 14
84 "D" "L"
12
86
88
90 STANDARD DUCT LENGTHS ( "L1" )
14
92 "L1" "L1"
JOINT SYSTEM DIAMETER ( 4' ) ( 8' )
94
96 EZ CLAMP / 4" & 6" 47.25" NA
98 16 CAST RING 8" TO 14" 47.25" 95.25"
12
100 4" & 6" 47.25" NA
102 14 12 BLACK IRON
8" TO 48" 47.25" 95.25"
104 ANGLE RING
106 50" TO 100" 46.75" 94.75"
108 16" TO 48" 47.25" 95.25"
12 10 STAINLESS
110 ANGLE RING
50" TO 100" 46.75" 94.75"
112 102" TO 120" 48.25" 96.25"
114
12 10
116
118
14
120
REV: 12/01/17 CAT010EA

Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®

11 DUCT & FITTINGS


Straight Duct with Fab-Tech Flange

DUCT

OUR RECOMMENDATION IS TO ADD TAPS TO


STANDARD 4' AND 8' STRAIGHT DUCT WHEN
POSSIBLE - TAP DIMENSIONS SHOWN ARE MINS

SEE FAB-TECH FLANGE SYSTEM SECTION FOR


ADAPTERS AND THE EZ FITTINGS SECTION FOR
DUCT TO USE WITH THE FAB-TECH FLANGE.
FAB-TECH FLANGE / TEST PORT MAY BE INSTALLED
ON FITTINGS OTHER THAN STRAIGHT DUCT ( USE
CUSTOM ORDER SHEET ). FAB-TECH FLANGE
( WELDED TO DUCT )

T.O.D.

90°

180° 0° "D1" "D2"


SPECIFY
270° PORT/DRAIN
LOCATION
ANGLE
FROM 0° EZ
3/4" STD
3" MAX 2" - FTFL2
VIEW OF "D1" DUCT END 3" - FTFL3

SPECIFY LOCATION
FROM "D1" END 4"
MIN

DUCT

FAB-TECH
FLANGE
"L"
CLAMP
"L"

EZ
ADAPTER
"D" OR PSP-EZ™
DUCT

PART NO. DESCRIPTION "D" "L"


FTFL2 2" FT FLANGE 2" .75"
FTFL3 3" FT FLANGE 3" .75"

REV: 12/01/17 CAT011EA

Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®

DUCT & FITTINGS 12


Straight Duct with Straight Tap
NOTE
WITH JOINT SYSTEM
All fittings with standard Fab-Tech
connections include gaskets and EZ CLAMP 4" - 14"
clamps or hardware as required SS CAST RING 4" - 14"
for installation.
BI ANGLE RING 4" - 100"
OPTIONS SS ANGLE RING 16" - 120"
Custom lengths available.
OR A COMBINATION OF
Raw end available. JOINING SYSTEMS
Multiple and offset taps available
(see the multiple tap page).
Duct greater than 84" diameter
requires Fab-Tech Engineering
review and approval.

T.O.D. OUR RECOMMENDATION IS TO ADD TAPS TO STANDARD 4' AND 8 STRAIGHT


DUCT WHEN POSSIBLE - TAP DIMENSIONS SHOWN ARE MINS
"L4" HORIZ.
OFFSET LONGER THAN STANDARD LENGTHS AND/OR HIGHER SYSTEM PRESSURES
MAY REQUIRE ADDITIONAL STIFFENERS PER SMACNA, CONTACT FAB-TECH
VERTICAL FOR SPECIFIC GUIDELINES.
90° OFFSET
"L3" "L5"
B A MIN DISTANCE TO DUCT END
0° "D1" = 4" - 94": 4" MIN
"D1" = 96" - 120": 5" MIN
C D

*4" MIN "D3" *4" MIN


"D1" TAP OFFSET VIEW 6" STD
"L3"

T.O.D.

90°

180° 0° "D1" "D2"

"A1"
270°
SPECIFY TAP
LOCATION ANGLE
FROM 0°

"L2"
VIEW OF "D1" DUCT END
"L1"

STANDARD DUCT LENGTHS ( "L1" ) STRAIGHT TAP


"L1" "L1"
JOINT SYSTEM DIAMETER ( 4' ) ( 8' ) "L1" MIN = "D3" + 8"
EZ CLAMP / 4" & 6" 47.25" NA "L1" MAX = 96-1/4"
CAST RING 8" TO 14" 47.25" 95.25" "D3" MAX = 88"
4" & 6" 47.25" NA STRAIGHT TAP GREATER THAN 88" [ "D3" ]
BLACK IRON REQUIRES 2 PIECE DESIGN
8" TO 48" 47.25" 95.25"
ANGLE RING AND ENGINEERING REVIEW
50" TO 100" 46.75" 94.75"
16" TO 48" 47.25" 95.25"
STAINLESS
50" TO 100" 46.75" 94.75"
ANGLE RING
102" TO 120" 48.25" 96.25"

REV: 12/01/17 CAT012EA

Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®

13 DUCT & FITTINGS


Straight Duct with Conical Tap
NOTE
WITH JOINT SYSTEM
All fittings with standard Fab-Tech
connections include gaskets and EZ CLAMP 4" - 14"
clamps or hardware as required SS CAST RING 4" - 14"
for installation.
BI ANGLE RING 4" - 100"
OPTIONS SS ANGLE RING 16" - 120"
Custom lengths available. OR A COMBINATION OF
Raw end available. JOINING SYSTEMS
Multiple and offset taps available
(see the multiple tap page).
Duct greater than 84" diameter
requires Fab-Tech Engineering
review and approval.
OUR RECOMMENDATION IS TO ADD TAPS TO STANDARD 4' AND 8 STRAIGHT
DUCT WHEN POSSIBLE - TAP DIMENSIONS SHOWN ARE MINS
T.O.D.
LONGER THAN STANDARD LENGTHS AND/OR HIGHER SYSTEM PRESSURES
"L4" HORIZ. MAY REQUIRE ADDITIONAL STIFFENERS PER SMACNA, CONTACT FAB-TECH
OFFSET
FOR SPECIFIC GUIDELINES.
VERTICAL
90° OFFSET
"L3" "L5" MIN DISTANCE TO DUCT END
B A "D1" = 4" - 94": 4" MIN
0° "D1" = 96" - 120": 5" MIN
C D

*4" MIN "D3" *4" MIN


9" STD
"D1" TAP OFFSET VIEW
"L3"

T.O.D. 6"

90°

180° "D1" "D2"


"A1"
270°
SPECIFY TAP
LOCATION ANGLE
FROM 0°
1" STD "C1"
"L2" 1" STD
VIEW OF "D1" DUCT END
"L1"

STANDARD DUCT LENGTHS ( "L1" ) CONICAL TAP


"L1" "L1" "L1" MIN = "D3" + 10"
JOINT SYSTEM DIAMETER ( 4' ) ( 8' )
4" & 6" 47.25" NA
"L1" MAX = 96-1/4"
EZ CLAMP /
CAST RING 8" TO 14" 47.25" 95.25" "D3" MAX = 86"
4" & 6" 47.25" NA CONICAL TAP GREATER THAN 86" [ "D3" ]
BLACK IRON REQUIRES 2 PIECE DESIGN
8" TO 48" 47.25" 95.25" AND ENGINEERING REVIEW
ANGLE RING
50" TO 100" 46.75" 94.75"
16" TO 48" 47.25" 95.25"
STAINLESS
50" TO 100" 46.75" 94.75"
ANGLE RING
102" TO 120" 48.25" 96.25"

REV: 12/01/17 CAT013EA

Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®

DUCT & FITTINGS 14


Straight Duct with Shoe Tap
NOTE
WITH JOINT SYSTEM
All fittings with standard Fab-Tech
connections include gaskets and EZ CLAMP 4" - 14"
clamps or hardware as required SS CAST RING 4" - 14"
for installation.
BI ANGLE RING 4" - 100"
OPTIONS
SS ANGLE RING 16" - 120"
Custom lengths available.
OR A COMBINATION OF
Raw end available.
JOINING SYSTEMS
Multiple and offset taps available
(see the multiple tap page).
Duct greater than 84" diameter
requires Fab-Tech Engineering
review and approval.
OUR RECOMMENDATION IS TO ADD TAPS TO STANDARD 4' AND 8 STRAIGHT
T.O.D. DUCT WHEN POSSIBLE - TAP DIMENSIONS SHOWN ARE MINS
"L4" HORIZ.
OFFSET LONGER THAN STANDARD LENGTHS AND/OR HIGHER SYSTEM PRESSURES
MAY REQUIRE ADDITIONAL STIFFENERS PER SMACNA, CONTACT FAB-TECH
VERTICAL FOR SPECIFIC GUIDELINES.
90° OFFSET
"L3" "L5" MIN DISTANCE TO DUCT END
B A
"D1" = 4" - 94": 4" MIN
0° "D1" = 96" - 120": 5" MIN
C D
*4" MIN "D3" *4" MIN
9" STD
"D1" TAP OFFSET VIEW "L3"

45°
T.O.D. 6" STD

90°

180° "D1" "D2"


"A1"
270°
SPECIFY TAP
LOCATION ANGLE
FROM 0°

"L2"
VIEW OF "D1" DUCT END
"L1"

STANDARD DUCT LENGTHS ( "L1" ) SHOE TAP


"L1" "L1" "L1" MIN = "D3" + 6" (SHOE LENGTH) + 8"
JOINT SYSTEM DIAMETER ( 4' ) ( 8' )
"L1" MAX = 96-1/4"
EZ CLAMP / 4" & 6" 47.25" NA
CAST RING 8" TO 14" 47.25" 95.25"
"D3" MAX = 86”
4" & 6" 47.25" NA SHOE TAP GREATER THAN MAX "D3"
BLACK IRON REQUIRES 2 PIECE DESIGN
8" TO 48" 47.25" 95.25" AND ENGINEERING REVIEW
ANGLE RING
50" TO 94" 46.75" 94.75"
16" TO 48" 47.25" 95.25"
STAINLESS
50" TO 100" 46.75" 94.75"
ANGLE RING
102" TO 120" 48.25" 96.25"

REV: 12/01/17 CAT014EA

Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®

15 DUCT & FITTINGS


Straight Duct with Lateral Tap
NOTE
WITH JOINT SYSTEM
All fittings with standard Fab-Tech
connections include gaskets and EZ CLAMP 4" - 14"
clamps or hardware as required SS CAST RING 4" - 14"
for installation.
BI ANGLE RING 4" - 100"
OPTIONS
SS ANGLE RING 16" - 120"
Custom lengths available.
OR A COMBINATION OF
Raw end available.
JOINING SYSTEMS
Multiple and offset taps available
(see the multiple tap page).
Duct greater than 84" diameter
requires Fab-Tech Engineering
review and approval.

T.O.D. OUR RECOMMENDATION IS TO ADD TAPS TO STANDARD 4' AND 8 STRAIGHT


DUCT WHEN POSSIBLE - TAP DIMENSIONS SHOWN ARE MINS
"L4" HORIZ.
OFFSET LONGER THAN STANDARD LENGTHS AND/OR HIGHER SYSTEM PRESSURES
MAY REQUIRE ADDITIONAL STIFFENERS PER SMACNA, CONTACT FAB-TECH
VERTICAL FOR SPECIFIC GUIDELINES.
90° OFFSET
"L3" "L5"
B A L2 MIN DISTANCE MIN LENGTH FOR "L3" AND "L4"
0° "D1" = 4" - 94": 4" MIN
"D1" = 96" - 120": 5" MIN "D1" "L3" "L4"
C D 4" - 48" 6" MIN 4" MIN
50" - 58" 7" MIN 4" MIN
4" MIN 60" - 94" 8" MIN 5" MIN
6" MIN 96" - 120" 10½" MIN 6" MIN
"L2"
"L3"
"D1" TAP OFFSET VIEW

"D3"

T.O.D.

90°

180° 0° "D1" "D2"

"A1"
270°
SPECIFY TAP
LOCATION ANGLE
FROM 0°

"L4" *4" MIN


VIEW OF "D1" DUCT END
"L1"

STANDARD DUCT LENGTHS ( "L1" ) 45° LATERAL TAP


"L1" "L1" "L1" MIN = ( "D3" X 1.414 ) + 4" + "L4"
JOINT SYSTEM DIAMETER ( 4' ) ( 8' ) ( SEE MIN LENGTH CHART ABOVE FOR "L4" )
4" & 6" 47.25" NA "L1" MAX = 96-1/4"
EZ CLAMP / "D3" MAX = 60"
CAST RING 8" TO 14" 47.25" 95.25"
4" & 6" 47.25" NA LATERAL TAP GREATER THAN 60" [ "D3" ]
BLACK IRON REQUIRES 2 PIECE DESIGN
8" TO 48" 47.25" 95.25" AND ENGINEERING REVIEW
ANGLE RING
50" TO 94" 46.75" 94.75"
16" TO 48" 47.25" 95.25"
STAINLESS
50" TO 100" 46.75" 94.75"
ANGLE RING
102" TO 120" 48.25" 96.25"

REV: 12/01/17 CAT015EA

Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®

DUCT & FITTINGS 16


Straight Duct with Multiple Taps
NOTE WITH JOINT SYSTEM
OUR RECOMMENDATION IS TO ADD TAPS TO
All fittings with standard Fab-Tech STANDARD 4' AND 8' STRAIGHT DUCT WHEN EZ CLAMP 4" - 14"
connections include gaskets and POSSIBLE - TAP DIMENSIONS SHOWN ARE MINS
clamps or hardware as required SS CAST RING 4" - 14"
for installation. LONGER THAN STANDARD LENGTHS AND/OR
HIGHER SYSTEM PRESSURES MAY REQUIRE BI ANGLE RING 4" - 100"
OPTIONS ADDITIONAL STIFFENERS PER SMACNA,
CONTACT FAB-TECH FOR SPECIFIC GUIDELINES. SS ANGLE RING 16" - 120"
Custom lengths available.
OR A COMBINATION OF
Raw end available. MIN DISTANCE TO DUCT END JOINING SYSTEMS
Duct greater than 84" diameter "D1" = 4" - 94": 4" MIN
"D1" = 96" - 120": 5" MIN
requires Fab-Tech Engineering
review and approval.
1" STD "C1" 3" MAX FOR 2" & 3" TAP 2" MIN
1" MIN BETWEEN 1" STD 6" MIN STD FOR EZ
ANGLE RINGS 2" MIN 4" "L3" CLAMP
FOR EZ MIN 4"
*4" "D3" CLAMPS "D3" MIN
9" STD MIN 9" STD "D3"
"L3" "L3"
6" STD 45°
"A2" STD
"L3"
6" 6"
45° STD STD

"D1" 1/2" MIN "D2"


FOR ANGLE RING

"L2" SHOE TAP "L3" EZ *4"


"L2" STRAIGHT OR 3/4" STD
BULLNOSE TAP 3" MAX MIN
"L2" CONICAL TAP "D3"
2" OR 3"
"L2" 45° LATERAL TAP DIA.
"L2" FAB-TECH FLANGE ( SEE FAB-TECH FLANGE SYSTEM SECTION )

"L1"
T.O.D.
STANDARD DUCT LENGTHS ( "L1" ) "L4" HORIZ.
T.O.D. SPECIFY OFFSET
TAP "L1" "L1"
ANGLE JOINT SYSTEM DIAMETER ( 4' ) ( 8' )
FROM 0° VERTICAL
90° AT D1 EZ CLAMP / 4" & 6" 47.25" NA 90° OFFSET
END CAST RING 8" TO 14" 47.25" 95.25" "L3" "L5"
B A
180° 0° 4" & 6" 47.25" NA
BLACK IRON 0°
"A1" 8" TO 48" 47.25" 95.25"
"L3" ANGLE RING C D
270° 50" TO 94" 46.75" 94.75"
16" TO 48" 47.25" 95.25"
STAINLESS
50" TO 100" 46.75" 94.75"
"D1" TAP ANGLE VIEW ANGLE RING "D1" TAP OFFSET VIEW
102" TO 120" 48.25" 96.25"

STANDARD MINIMUMS FOR 45° LATERAL AND 90° STRAIGHT TAPS:


4"-48" DUCT 50"-58" DUCT 60"-94" DUCT 96"-120" DUCT 96"-120" DUCT
2" X 2" RINGS 2-1/2" X 2-1/2" RINGS 3" X 3" RINGS 4" X 4" RINGS 4" X 4" RINGS

10½"
8" MIN
6" 7" MIN
MIN MIN 6"
MIN

4" 4" 5" 6" 5"


MIN MIN MIN MIN MIN
REV: 12/01/17 CAT016EA

Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®

17 DUCT & FITTINGS


Gored Elbow
NOTE
All fittings with standard Fab-Tech WITH JOINT SYSTEM
connections include gaskets and clamps EZ CLAMP 4" - 14"
or hardware as required for installation. SS CAST RING 4" - 14"
OPTIONS BI ANGLE RING 4" - 100"
Standard gores and radii are shown,
SS ANGLE RING 16" - 120"
custom number of gores, custom radii,
and throat extensions are available. OR A COMBINATION OF
Duct greater than 84" diameter JOINING SYSTEMS
requires Fab-Tech Engineering
review and approval.

90° ELBOW

LIMITATIONS
5 GORE
DUE TO MANUFACTURING LIMITATIONS, THE
FOLLOWING ELBOWS ARE NOT AVAILABLE AS
"D" ONE PIECE FITTINGS:
FULL RADIUS 90° ELBOW > 56" DIA.
FULL RADIUS 60° ELBOW > 82" DIA.
FULL RADIUS 45° ELBOW > 106" DIA.
HALF RADIUS 90° ELBOW > 76" DIA.
"R1"
LARGE ELBOWS ABOVE THESE LIMITS WILL
"R2"
BE MANUFACTURED AS SMALLER FITTINGS
( AN 86" DIA. 90° ELBOW WILL BE SUPPLIED
CL AS TWO 45° ELBOWS FOR EXAMPLE ) OR AS
A CLAM SHELL DESIGNED FITTING AS TWO
OR MORE PIECES. THIS APPLIES TO ALL
STANDARD RADIUS AT THE DUCT CENTERLINE LARGE FITTINGS AS WELL AS ELBOWS.
"R1" = 1.5 X "D" ALSO DUE TO MANUFACTURING LIMITATIONS,
STANDARD THROAT RADIUS MANY OF THE SMALLER 1/2 RADIUS ELBOWS
"R2" = "D" WILL REQUIRE CAST RINGS OR FLAT RINGS.

4 GORE
3 GORE
2 GORE

CL CL CL
60° ELBOW 45° ELBOW 30° ELBOW

REV: 12/01/17 CAT017EA

Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®

DUCT & FITTINGS 18


Concentric and Eccentric Reducer

WITH JOINT SYSTEM


NOTE
All fittings with standard Fab-Tech EZ CLAMP 4" - 14"
connections include gaskets and SS CAST RING 4" - 14"
clamps or hardware as required BI ANGLE RING 4" - 100"
for installation.
SS ANGLE RING 16" - 120"
OPTIONS
OR A COMBINATION OF
Custom lengths available. JOINING SYSTEMS

"L3"

"D1"
"D2" "D1" "D2"

"L4" "L2" "L5" "L4" "L2" "L5"


"L1"
"L1"

ECCENTRIC CONCENTRIC
Formula to calculate the minimum length for Formula to calculate the minimum length for
an eccentric reducer: a concentric reducer:
"L1" = "L2" + "L4" + "L5" "L1" = "L2" + "L4" + "L5"

Use this chart for minimum length of "L2": Use this chart for minimum length of "L2":
( Shorter taper or "L2" length can be fabricated, ( Shorter taper or "L2" length can be fabricated,
but will effect air flow. ) but will effect air flow. )
AMOUNT OF MINIMUM AMOUNT OF MINIMUM
REDUCTION LENGTH REDUCTION LENGTH
"D1" minus "D2" "L2" "D1" minus "D2" "L2"
6" AND LESS 12" 9" AND LESS 12"
7" TO 9" 18" 10" TO 14" 18"
10" TO 13" 24" 15" TO 19" 24"
14" TO 17" 30" 20" TO 24" 30"

Use this chart for minimum length of "L4" & "L5": Use this chart for minimum length of "L4 & "L5":
MINIMUM MINIMUM
DUCT DIAMETER LENGTH DUCT DIAMETER LENGTH
"D1" or "D2" "L4" or "L5" "D1" or "D2" "L4" or "L5"
4" TO 58" 3" 4" TO 58" 3"
60" TO 94" 4" 60" TO 94" 4"
96" TO 120" 5" 96" TO 120" 5"

REV: 12/01/17 CAT018EA

Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®

19 DUCT & FITTINGS


Offset

WITH JOINT SYSTEM


EZ CLAMP 4" - 14"
SS CAST RING 4" - 14"
BI ANGLE RING 4" - 100"
SS ANGLE RING 16" - 120"
OR A COMBINATION OF
JOINING SYSTEMS

NOTE
All fittings with standard Fab-Tech connections
include gaskets and clamps or hardware as
required for installation.

"D2"

"L2"

"D1"

"L1"

REV: 12/01/17 CAT019EA

Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®

DUCT & FITTINGS 20


End Cap
NOTE
All fittings with standard Fab-Tech connections include gaskets
and clamps or hardware as required for installation.
OPTIONS
Clear polycarbonate viewport endcaps available up to 12" dia.
Larger sizes available with engineering review and approval.
END CAP
HAT STYLE CLEAR POLYCARBONATE
END CAP END CAP ( SEE OPTIONS )
HAT STYLE
( SEE OPTIONS )

"D"
"D" DUCT DIA
DUCT DIA

1/2"
1/2"
4" - 14"
PSP-EZ™
4" - 14" CONFIGURATION
CAST RING
CONFIGURATION
END CAP - FLAT PLATE
( SEE OPTIONS )
END CAP - HAT STYLE
SAME AS FOR EZ CONFIG
( SEE OPTIONS )

"D"
DUCT DIA

"D"
DUCT DIA

16" - 120"
ANGLE RING CONFIGURATION
4" - 14" WITH ADDED SUPPORT
BLACK IRON ANGLE RING
ANGLE RING
CONFIGURATION TRANSVERSE STIFFENERS REQUIRED
FOR END CAPS OVER 36" DIA.
REV: 12/01/17 CAT020EA

Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®

21 DUCT & FITTINGS


Concentric Round to Rectangular Transition

WITH ROUND JOINT SYSTEM


EZ CLAMP 4" - 14"
SS CAST RING 4" - 14"
BI ANGLE RING 4" - 100"
SS ANGLE RING 16" - 120"

NOTES
All fittings with standard Fab-Tech connections include gaskets and clamps or hardware as
required for installation.
Raw end available.
Round duct greater than 84" diameter requires Fab-Tech Engineering review and approval.
Rectangular duct width or height of 98" and larger requires Fab-Tech Engineering review.
A center stiffener (1" SCH40 pipe ) is added at the midpoint of the flange for rectangular duct
width or height of 50" and greater.

"X" "L1"

"R" "DØ"
"Y"

"L2"
3" MIN

FOR ECCENTRIC ROUND TO


RECTANGULAR FITTING, USE THE
CUSTOM FITTING ORDER SHEET.

REV: 12/01/17 CAT021EA

Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®

DUCT & FITTINGS 22


Custom Fitting

90 DEGREE REDUCING TEE 90 DEGREE WYE

ELBOW WITH HEEL TAP ECCENTRIC ROUND TO RECTANGULAR TRANSITION

WITH ROUND JOINT SYSTEM


EZ CLAMP 4" - 14" NOTE
SS CAST RING 4" - 14" All fittings with standard Fab-Tech connections
BI ANGLE RING 4" - 100" include gaskets and clamps or hardware as
required for installation.
SS ANGLE RING 16" - 120"
OR A COMBINATION OF
JOINING SYSTEMS

USE CUSTOM FITTING ORDER SHEET TO DESCRIBE YOUR FITTING.

REV: 12/01/17 CAT022EA

Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®

23 CONTROL DEVICES
Product Guide
4"-12" WAFER 4"-14" INDUSTRIAL 4" INDUSTRIAL
ISOLATION BALANCING ISOLATION
CONTROL DAMPER DAMPER DAMPER
DEVICES
SIZE: 4"-12" SIZE: 4"-14" SIZE: 4"
PAGE: 24 PAGE: 26 PAGE: 27
6"-14" INDUSTRIAL AMCA 4"-14" INDUSTRIAL AMCA
ISOLATION 6"-14" INDUSTRIAL SHORT DAMPER - 16"-34" HIGH
DAMPER ISOLATION ISOLATION & VALUE HEAVY
DAMPER BALANCING DUTY INDUSTRIAL
SIZE: 6"-14" SIZE: 6"-14" SIZE: 4"-14" SIZE: 16"-34"
PAGE: 28 PAGE: 29 PAGE: 30 PAGE: 32
16"-48" HIGH VALUE
HEAVY DUTY
AMCA 50" & LARGER
HEAVY DUTY
24"-84"
ULTRA SERIES
36"-48" HIGH
INDUSTRIAL VALUE HEAVY INDUSTRIAL INDUSTRIAL
DAMPER (HVD) DUTY INDUSTRIAL DAMPER DAMPER
SIZE: 16"-34" SIZE: 36"-48" SIZE: 50"-120" SIZE: 24"-84"
PAGE: 33 PAGE: 34 PAGE: 35 PAGE: 36
4"-36" HORIZONTAL 16"-36" HORIZONTAL 38" & LARGER 38" & LARGER
RUN BLASTGATE RUN ACTUATED HORIZONTAL RUN HORIZONTAL RUN
BLASTGATE BLASTGATE ACTUATED
BLASTGATE
SIZE:4"-36" SIZE:4"-36" SIZE:38"-120" SIZE:38"-120"
PAGE: 38 PAGE: 39 PAGE: 40 PAGE: 41
4"-36" 16"-36" VERTICAL 38" & LARGER 38" & LARGER
VERTICAL RUN RUN ACTUATED VERTICAL RUN VERTICAL RUN
ISOLATION BLASTGATE ISOLATION ACTUATED
BLASTGATE BLASTGATE BLASTGATE
SIZE: 4"-36" SIZE: 16"-36" SIZE: 38"-120" SIZE: 38"-120"
PAGE: 42 PAGE: 43 PAGE: 44 PAGE: 45

2" & 3" MICRO 4"-14" INDUSTRIAL 4" INDUSTRIAL


CONTROL ADJUSTABLE BALANCING ISOLATION
DAMPER
EZ DAMPER DAMPER
DEVICES
PSP-EZ™ SIZE:2" & 3" SIZE: 4" TO 14" SIZE: 4"
PAGE: 25 PAGE: 26 PAGE: 27
6"-14" INDUSTRIAL
ISOLATION
AMCA HORIZONTAL RUN
& VERTICAL RUN
HORIZONTAL RUN
BLASTGATE
DAMPER 6"-14" INDUSTRIAL EZ BLASTGATE
ISOLATION
DAMPER
SIZE: 6" TO 14" SIZE: 6" TO 14" SIZE: 2" & 3" SIZE:4" TO 14"
PAGE: 28 PAGE: 29 PAGE: 37 PAGE: 38
VERTICAL RUN
BLASTGATE

SIZE: 4" TO 14"


PAGE: 42

REV: 12/01/17 CAT023EA

Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®

CONTROL DEVICES 24
4"-14" Wafer Isolation Damper
SPECIFICATIONS
BODY: COATED SOLID ALUMINUM BODY
BODY LENGTH: 1"
COATING: PERMASHIELD FLUOROPOLYMER
BARRIER COATING
BLADE: COATED 10GA STAINLESS STEEL
WITH FULLY WELDED DRIVE AXLE
4"Ø BLADE: MACHINED PTFE
EDGE SEALS: VITON EXTRUDED RUBBER
BLADE HOLDERS: MOLDED 25% GLASS
FILLED PTFE
AXLE: DUAL SHAFT 1/2"Ø STAINLESS STEEL
AXLE SEALS: LIQUID TIGHT - POS & NEG
SYSTEM PRESSURE
BEARINGS: NYLON
COATING: FLUOROPOLYMER BARRIER
COATING
QUADRANT: MANUAL LOCKING HANDLE BOLT HOLE SPECIFICATIONS
LOCKOUT: 1/2° INTERVALS DUCT NO. BOLT BOLT BOLT
BLADE OPENS: CW DIA OF HOLE SIZE CIRCLE
OPEN/CLOSE TORQUE: 250 in-lb “D” HOLES SIZE DIA.
RECOMMENDED MIN 4 5.31
6
NOTE: All fittings with standard Fab-Tech 6 7.50
7/16 3/8
connections include gaskets and clamps or 8 9.50
8
hardware as required for installation. 10 11.50
12 13.81
12 9/16 1/2
14 15.81

C 1”

"D"
EXTRUDED
FLUOROELASTOMER
ISOLATION
BLADE SEAL
REV: 12/01/17 CAT024EA

Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®

25 CONTROL DEVICES
2" & 3" Micro-Adjustable EZ Damper

NOTE
All fittings with standard Fab-Tech connections include gaskets and
clamps or hardware as required for installation.

PART NO. DESCRIPTION "D" "L"


PZD02 2" EZ-DAMPER 2" 3.875"
PZD03 3" EZ-DAMPER 3" 3.875"

"L"
POSITION LOCK
ACTUATOR
THUMB WHEEL PLATE
FRICTION WHEEL

"D"

REV: 12/01/17 CAT025EA

Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®

CONTROL DEVICES 26
4"-14" Industrial Balancing Damper
SPECIFICATIONS
BODY: COATED 20GA STAINLESS STEEL
BODY LENGTH: 9-1/4"
OPTION: CUSTOM LENGTH
COATING: PERMASHIELD FLUOROPOLYMER
BARRIER COATING
JOINING SYSTEM: FLOATING CAST STAINLESS
STEEL RINGS
OPTION: PSP-EZ™ JOINING SYSTEM 4"-14"
OPTION: FLOATING BLACK IRON
ANGLE RINGS 4"-14"
OPTION: CUSTOM HOLE PATTERN
PTFE BLADE: 4"Ø DAMPER ONLY
BLADE: COATED 10GA STAINLESS STEEL
BLADE HOLDERS: MOLDED PTFE
AXLES: DUAL SHAFT 1/2"Ø STAINLESS STEEL
AXLE SEALS: LIQUID TIGHT
ACTUATOR: MANUAL LEVER
OPTION: ELECTRIC ACTUATOR
OPTION: PNEUMATIC ACTUATOR
LOCKOUT: 1/2° INTERVALS
BLADE OPENS: CCW
OPEN/CLOSE TORQUE: 250 in-lb RECOMMENDED MIN 4" PTFE blade
with molded PTFE
NOTE: All fittings with standard Fab-Tech blade holders
connections include gaskets and clamps or
hardware as required for installation.

"D"

DIAMETER BLADE BODY


4" PTFE 20GA
6" TO 14" 10GA 20GA
3"

9.25" STD

REV: 12/01/17 CAT026EA

Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®

27 CONTROL DEVICES
4" Industrial Isolation Damper

Virgin Teflon blade


with fluoroelastomer
edge seal

SPECIFICATIONS
BODY: COATED 20GA STAINLESS STEEL
0.35 BODY LENGTH: 9-1/4"
OPTION: CUSTOM LENGTH
0.3
COATING: PERMASHIELD FLUOROPOLYMER
Leakage (CFM)

0.25 BARRIER COATING


JOINING SYSTEM: FLOATING CAST STAINLESS
0.2 STEEL RINGS
OPTION: PSP-EZ™ JOINING SYSTEM 4"
0.15
OPTION: CUSTOM HOLE PATTERN
0.1 BLADE & BLADE HOLERS: VIRGIN TEFLON
EDGE SEALS: FLUOROELASTOMER
0.05 AXLES: DUAL SHAFT 1/2"Ø STAINLESS STEEL
0 AXLE SEALS: LIQUID TIGHT
0 5 10 15 ACTUATOR: MANUAL LEVER
OPTION: ELECTRIC ACTUATOR
Pressure (in. wg) OPTION: PNEUMATIC ACTUATOR
Damper Leakage Test based on ANSI/AMCA Standard 500-D-07, Ref. Fig 5.6 LOCKOUT: 1/2° INTERVALS
BLADE OPENS: CCW
1.0 OPEN/CLOSE TORQUE: 250 in-lb RECOMMENDED MIN
NOTE: All fittings with standard Fab-Tech
connections include gaskets and clamps or
Pressure Drop (in. wg)

hardware as required for installation.


0.1
3"

0.01

"D"

0.001
100 1000 10000
Velocity (f/m) 9.25" STD

Pressure Drop Test based on AMCA Standard 500-D-98, Ref. Fig 5.3
REV: 12/01/17 CAT027EA

Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®

CONTROL DEVICES 28
6"-14" Industrial Isolation Damper
SPECIFICATIONS
BODY: COATED 20GA STAINLESS STEEL
BODY LENGTH: 9-1/4"
OPTION: CUSTOM LENGTH
COATING: PERMASHIELD FLUOROPOLYMER
BARRIER COATING
JOINING SYSTEM: FLOATING CAST STAINLESS
STEEL RINGS
OPTION: PSP-EZ™ JOINING SYSTEM 6"-14"
OPTION: FLOATING BLACK IRON
ANGLE RINGS 6"-14"
OPTION: CUSTOM HOLE PATTERN
BLADE: 10GA COATED STAINLESS STEEL
EDGE SEALS: FLUOROELASTOMER
BLADE HOLDERS: MOLDED PTFE
AXLES: DUAL SHAFT 1/2"Ø STAINLESS STEEL
AXLE SEALS: LIQUID TIGHT
ACTUATOR: MANUAL LEVER
OPTION: ELECTRIC ACTUATOR
OPTION: PNEUMATIC ACTUATOR
LOCKOUT: 1/2° INTERVALS
BLADE OPENS: CCW
OPEN/CLOSE TORQUE: 250 in-lb RECOMMENDED MIN
NOTE: All fittings with standard Fab-Tech
connections include gaskets and clamps or
hardware as required for installation.

"D"

VITON
EDGE
SEAL
3"

9.25" STD

REV: 12/01/17 CAT028EA

Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®

29 CONTROL DEVICES
6"-14" AMCA Industrial Isolation Damper
Fab-Tech, Inc. certifies that the Industrial Single Blade
Isolation Damper shown herein is licensed to bear the CERTIFIED
AMCA Seal. The ratings shown are based on tests RATINGS
and procedures performed in accordance with AMCA
Publication 511 and comply with the requirements of
AIR
LEAKAGE

the AMCA Certified Ratings Program. AIR


PERFORMANCE

R
AIR
The AMCA Certified Ratings Seal applies to Air MOVEMENT
AND CONTROL
Leakage ratings and Air Performance ratings. ASSOCIATION
INTERNATIONAL, INC.
1. Test method per AMCA Standard 500-89
Data based on a seating torque of: 764 in-lbf/ft2
for 6" damper, 234 in-lbf/ft2 for 14" damper
2. Air leakage is based on operation between
SPECIFICATIONS
50°F & 104°F (10°C to 40°C) and data corrected
to represent standard air density 0.075 lbs/ft3. BODY: COATED 20GA STAINLESS STEEL
BODY LENGTH: 9-1/4"
Damper Dia. Pressure AMCA Leakage Class OPTION: CUSTOM LENGTH
1"WG 1A COATING: PERMASHIELD FLUOROPOLYMER
6" - 14" BARRIER COATING
4",8",12"WG 1
Tested Leakage Rates Available, Contact Fab-Tech Inc. JOINING SYSTEM: FLOATING CAST STAINLESS
STEEL RINGS
Leakage Classification L/s/m2 (ft3/min/ft2) OPTION: PSP-EZ™ JOINING SYSTEM 6"-14"
OPTION: FLOATING BLACK IRON
Pressure Required Extended
Class Range Range (Optional) ANGLE RINGS 6"-14"
OPTION: CUSTOM HOLE PATTERN
0.25 kPa 1.0 kPa 2.0 kPa 3.0 kPa
(1” wg) (4” wg) (8” wg) (12” wg) BLADE: 10GA COATED STAINLESS STEEL
EDGE SEALS: FLUOROELASTOMER
1A 15.2 (3)* N/A N/A N/A
BLADE HOLDERS: MOLDED PTFE
1 20.3 (4) 40.6 (8) 55.9 (11) 71.1 (14)
AXLES: DUAL SHAFT 1/2"Ø STAINLESS STEEL
2 50.8 (10) 102 (20) 142 (28) 178 (35) AXLE SEALS: LIQUID TIGHT
3 203 (40) 406 (80) 569 (112) 711 (140) ACTUATOR: MANUAL LEVER
*Units for maximum ratings in ( ) are CFM Sq. Ft. OPTION: ELECTRIC ACTUATOR
OPTION: PNEUMATIC ACTUATOR
Damper Leakage Test based on ANSI/AMCA Standard 500-D-07, Ref. Fig 5.6
Pressure Drop Test based on AMCA Standard 500-D-98, Ref. Fig 5.3 LOCKOUT: 1/2° INTERVALS
BLADE OPENS: CCW
OPEN/CLOSE TORQUE: 250 in-lb
1.0
RECOMMENDED MINIMUM
NOTE: All fittings with standard Fab-Tech
connections include gaskets and clamps or
Pressure Drop (in. wg)

hardware as required for installation.


6
0.1

10

14
0.01

"D"

0.001 EXTRUDED
FLUOROELASTOMER 3"
100 1000 10000 RUBBER EDGE SEAL
9.25" STD
Velocity (f/m) REV: 12/01/17 CAT029EA

Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®

CONTROL DEVICES 30
4"-14" Industrial Short Damper - Isolation & Balancing
SPECIFICATIONS
BODY: COATED 20GA STAINLESS STEEL
BODY LENGTH: 4" MINIMUM
OPTION: CUSTOM LENGTH
COATING: PERMASHIELD FLUOROPOLYMER
BARRIER COATING
JOINING SYSTEM: FLOATING CAST STAINLESS
STEEL RINGS
OPTION: FLOATING STAINLESS STEEL
FLAT RINGS 4"-14"
OPTION: FLOATING BLACK IRON
FLAT RINGS 4"-14"
OPTION: PSP-EZ™ JOINING SYSTEM 4"-14"
OPTION: CUSTOM HOLE PATTERN
BLADE: 4": VIRGIN TEFLON
6"-14":10GA COATED STAINLESS STEEL
EDGE SEALS: FLUOROELASTOMER
BLADE HOLDERS: MOLDED PTFE
AXLES: DUAL SHAFT 1/2"Ø STAINLESS STEEL
AXLE SEALS: LIQUID TIGHT
ACTUATOR: MANUAL LEVER
LOCKOUT: 1/2° INTERVALS
BLADE OPENS: CCW
OPEN/CLOSE TORQUE: 250 in-lb RECOMMENDED MIN
NOTE: All fittings with standard Fab-Tech 4" PTFE blade
connections include gaskets and clamps or with molded PTFE
hardware as required for installation. blade holders

4-1/2" MIN for D1 & D2 as SS cast rings


DIAMETER BLADE BODY 7" MIN for D1 & D2 as Van Stone rings
4" PTFE 20GA 4-1/2" MIN for D1 as Van Stone & D2 as EZ Flange
4" MIN for D1 & D2 as EZ Flanges
6" TO 14" 10GA 20GA

"D"

REV: 12/01/17 CAT030EA

Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®

31 CONTROL DEVICES
6”-14" Industrial Isolation Damper

PL-X
PL-Y PL-1 PL-4 PL-Z
PL-9 PL-2
6D min. 10D min.
D ± 0.02D D ± 0.02D
t d9

From Supply
System and
Airflow
Measuring
Section

Inlet Cone Required


if Attached to Plenum Device
PS9 Under PS4
Test

D = duct diameter for round ducts

Fig. 5.3: Test Damper Setup with Inlet and Outlet Ducts

Blank off plate.


Seal airtight to
Flowmeter damper flange.

Pressurized
Supply Air

Device
AIRFLOW Under
Test

PS9

Fig. 5.6: Test Damper Setup - Leakage Test with Damper under
Positive Pressure

REV: 12/01/17 CAT031EA

Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®

CONTROL DEVICES 32
16"-34" AMCA High Value Heavy Duty Industrial Damper
Fab-Tech, Inc. certifies that the Industrial Single Blade
Isolation Damper shown herein is licensed to bear the CERTIFIED
AMCA Seal. The ratings shown are based on tests RATINGS
and procedures performed in accordance with AMCA
Publication 511 and comply with the requirements of
AIR
LEAKAGE

the AMCA Certified Ratings Program. AIR


PERFORMANCE

R
AIR
The AMCA Certified Ratings Seal applies to Air MOVEMENT
AND CONTROL
Leakage ratings and Air Performance ratings. ASSOCIATION
INTERNATIONAL, INC.
1. Test method per AMCA Standard 500-89
Data based on a seating torque of: 125 in-lbf/ft2
for 16" damper, 86 in-lbf/ft2 for 48" damper
2. Air leakage is based on operation between
50°F & 104°F (10°C to 40°C) and data corrected SPECIFICATIONS
to represent standard air density 0.075 lbs/ft3.
BODY: COATED 12GA STAINLESS STEEL
BODY LENGTH: 10"
Damper Dia. Pressure AMCA Leakage Class COATING: PERMASHIELD FLUOROPOLYMER
1"WG 1A BARRIER COATING
16" - 34" JOINING SYSTEM: STITCH WELDED COATED BLACK
4",8",12"WG 1 IRON VAN STONE RINGS
Tested Leakage Rates Available, Contact Fab-Tech Inc. OPTION: CUSTOM HOLE PATTERN
MOUNTING HOLES: STRADDLE VERTICAL
Leakage Classification L/s/m2 (ft3/min/ft2) CENTERLINE
Pressure Required Extended BLADE: 1/4" COATED STAINLESS STEEL WITH
Class Range Range (Optional) VITON EDGE SEAL
BLADE STOPS: WELDED
0.25 kPa 1.0 kPa 2.0 kPa 3.0 kPa AXLES: DUAL SHAFT 1.38Ø STAINLESS STEEL
(1” wg) (4” wg) (8” wg) (12” wg) AXLE SEALS: LIQUID TIGHT
1A 15.2 (3)* N/A N/A N/A SLEEVE BEARINGS: THERMOPLASTIC
1 20.3 (4) 40.6 (8) 55.9 (11) 71.1 (14) ACTUATOR: MANUAL LEVER
OPTION: MANUAL GEAR BOX W/ LOCK OUT
2 50.8 (10) 102 (20) 142 (28) 178 (35) OPTION: CUSTOM ACTUATOR MOUNTING KIT
3 203 (40) 406 (80) 569 (112) 711 (140) OPTION: ELECTRIC ACTUATOR
*Units for maximum ratings in ( ) are CFM Sq. Ft. OPTION: PNEUMATIC ACTUATOR
LOCKOUT: 1/2° INTERVALS
Damper Leakage Test based on ANSI/AMCA Standard 500-D-07, Ref. Fig 5.6 BLADE OPENS: CCW
Pressure Drop Test based on AMCA Standard 500-D-98, Ref. Fig 5.3 OPEN/CLOSE TORQUE: 1000 in-lb RECOMMENDED MIN
NOTE: All fittings with standard Fab-Tech
1.0 connections include gaskets and clamps or
hardware as required for installation.
16
Pressure Drop (in. wg)

10" STD
24
5" STD
36 "D"
0.1

0.01
19.26"

0.001 STAINLESS STEEL


HANDLE
QUADRANT
100 1000 10000 HANDLE SHOWN LOCKING
NUT
Velocity (f/m) REV: 12/01/17 CAT032EA

Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®

33 CONTROL DEVICES
16"-48" High Value Heavy Duty Industrial Damper (HVD)
SPECIFICATIONS
BODY: COATED 12GA STAINLESS STEEL
BODY LENGTH: 10"
COATING: PERMASHIELD FLUOROPOLYMER
BARRIER COATING
JOINING SYSTEM: STITCH WELDED COATED BLACK
IRON VAN STONE RINGS
OPTION: CUSTOM HOLE PATTERN
OPTION: STITCH WELDED STAINLESS STEEL
VAN STONE RINGS
MOUNTING HOLES: STRADDLE VERTICAL
CENTERLINE
BLADE: 1/4" COATED STAINLESS STEEL
BLADE STOPS: WELDED W/ VITON BLADE SEAL
AXLES: DUAL SHAFT 1.38Ø STAINLESS STEEL
AXLE SEALS: LIQUID TIGHT
SLEEVE BEARINGS: THERMOPLASTIC
ACTUATOR: MANUAL LEVER
OPTION: MANUAL GEAR BOX W/ LOCK OUT
OPTION: CUSTOM ACTUATOR MOUNTING KIT
OPTION: ELECTRIC ACTUATOR
OPTION: PNEUMATIC ACTUATOR
LOCKOUT: 1/2° INTERVALS
BLADE OPENS: CCW
OPEN/CLOSE TORQUE: 1000 in-lb RECOMMENDED MIN
NOTE: All fittings with standard Fab-Tech
connections include gaskets and clamps or
hardware as required for installation.
10" STD
5" STD

"D"

19-1/4"

STAINLESS STEEL HANDLE


QUADRANT LOCKING
HANDLE SHOWN NUT

*SHOWN WITH MANUAL HANDLE ACTUATOR OPTION

REV: 12/01/17 CAT033EA

Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®

CONTROL DEVICES 34
36"-48" AMCA High Value Heavy Duty Industrial Damper

Fab-Tech, Inc. certifies that the Industrial Single Blade CERTIFIED


Isolation Damper shown herein is licensed to bear the RATINGS
AMCA Seal. The ratings shown are based on tests
and procedures performed in accordance with AMCA AIR
LEAKAGE

Publication 511 and comply with the requirements of AIR


PERFORMANCE
the AMCA Certified Ratings Program. R
AIR
MOVEMENT
The AMCA Certified Ratings Seal applies to Air AND CONTROL
ASSOCIATION
Leakage ratings and Air Performance ratings. INTERNATIONAL, INC.

1. Test method per AMCA Standard 500-89


Data based on a seating torque of: 125 in-lbf/ft2
for 16" damper, 86 in-lbf/ft2 for 48" damper SPECIFICATIONS
2. Air leakage is based on operation between BODY: COATED 12GA STAINLESS STEEL
50°F & 104°F (10°C to 40°C) and data corrected BODY LENGTH: 10"
to represent standard air density 0.075 lbs/ft3. COATING: PERMASHIELD FLUOROPOLYMER
BARRIER COATING
Damper Dia. Pressure AMCA Leakage Class JOINING SYSTEM: STITCH WELDED COATED
1"WG 1A BLACK IRON VAN STONE RINGS
36" - 48" OPTION: CUSTOM HOLE PATTERN
4",8",12"WG 1
Tested Leakage Rates Available, Contact Fab-Tech Inc. MOUNTING HOLES: STRADDLE VERTICAL
CENTERLINE
Leakage Classification L/s/m2 (ft3/min/ft2) BLADE: 1/4" COATED STAINLESS STEEL
Pressure Required Extended WITH VITON EDGE SEAL
Class Range Range (Optional) BLADE STOPS: WELDED
0.25 kPa 1.0 kPa 2.0 kPa 3.0 kPa AXLES: DUAL SHAFT 1.38Ø STAINLESS STEEL
(1” wg) (4” wg) (8” wg) (12” wg) AXLE SEALS: LIQUID TIGHT
1A 15.2 (3)* N/A N/A N/A SLEEVE BEARINGS: THERMOPLASTIC
1 20.3 (4) 40.6 (8) 55.9 (11) 71.1 (14) ACTUATOR: MANUAL GEAR BOX W/ LOCK OUT
OPTION: CUSTOM ACTUATOR MOUNTING KIT
2 50.8 (10) 102 (20) 142 (28) 178 (35)
OPTION: ELECTRIC ACTUATOR
3 203 (40) 406 (80) 569 (112) 711 (140)
OPTION: PNEUMATIC ACTUATOR
*Units for maximum ratings in ( ) are CFM Sq. Ft. LOCKOUT: 1/2° INTERVALS
Damper Leakage Test based on ANSI/AMCA Standard 500-D-07, Ref. Fig 5.6 BLADE OPENS: CCW
Pressure Drop Test based on AMCA Standard 500-D-98, Ref. Fig 5.3 OPEN/CLOSE TORQUE: 1000 in-lb RECOMMENDED MIN
NOTE: All fittings with standard Fab-Tech
1.0 connections include gaskets and clamps or
hardware as required for installation.
16
Pressure Drop (in. wg)

10" STD
24
"D" 5" STD
36
0.1

0.01

0.001
100 1000 10000 LOCKOUT

Velocity (f/m) REV: 12/01/17 CAT034EA

Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®

35 CONTROL DEVICES
50" & Larger Reinforced Heavy Duty Industrial Damper
SPECIFICATIONS
BODY: COATED 1/4" STAINLESS STEEL
OPTION: AVAIL TO 120" DIA W/ ENGINEERING REVIEW
BODY LENGTH: 10"
COATING: PERMASHIELD FLUOROPOLYMER
BARRIER COATING
JOINING SYSTEM: FULLY WELDED STAINLESS
STEEL VAN STONE RINGS
OPTION: CUSTOM HOLE PATTERN
MOUNTING HOLES: STRADDLE VERTICLE
CENTERLINE
BLADE: 3/8" COATED REINFORCED
STAINLESS STEEL
BLADE STOPS: WELDED
AXLES: DUAL SHAFT 1.85Ø STAINLESS STEEL
AXLE SEALS: LIQUID TIGHT
SLEEVE BEARINGS: THERMOPLASTIC
ACTUATOR: GEAR ACTUATOR W/ LOCK OUT
OPTION: CUSTOM ACTUATOR MOUNTING KIT
OPTION: ELECTRIC ACTUATOR
OPTION: PNEUMATIC ACTUATOR
PNEUMATIC ACTUATED DAMPERS
HYTORK ACTUATOR STANDARD
XL45 - UP TO 20"
XL280 - 21" TO 48"
XL425 - 49" TO 94"

LOCKOUT: 1/2° INTERVALS


BLADE OPENS: CCW
OPEN/CLOSE TORQUE: 1600 in-lb RECOMMENDED MIN
10"
NOTE: All fittings with standard Fab-Tech STD
connections include gaskets and clamps or 5"
hardware as required for installation. STD

"D"

BLADE STOP

REV: 12/01/17 CAT035EA

Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®

CONTROL DEVICES 36
24" - 84" Ultra Series Industrial Damper
SPECIFICATIONS
BODY: COATED 24"-40" DIA. 10GA STAINLESS STEEL
COATED 42"-84" DIA. 1/4" STAINLESS STEEL
OPTION: AVAIL TO 120" DIA W/ ENGINEERING REVIEW
BODY LENGTH: 10"
COATING: PERMASHIELD FLUOROPOLYMER
BARRIER COATING
JOINING SYSTEM: FULLY WELDED STAINLESS
STEEL VAN STONE RINGS
OPTION: CUSTOM HOLE PATTERN
MOUNTING HOLES: STRADDLE VERTICAL
CENTERLINE
BLADE: COATED REINFORCED
24"-58" DIA. 1/4" STAINLESS STEEL
60"-84" DIA. 3/8" STAINLESS STEEL
BLADE STOPS: WELDED
AXLES: 24"-44" DIA. DUAL SHAFT 1.20Ø STAINLESS STEEL
46"-58" DIA. DUAL SHAFT 1.85Ø STAINLESS STEEL
60" DIA. & UP DUAL SHAFT 2.45Ø STAINLESS STEEL
AXLE SEALS: LIQUID TIGHT
SLEEVE BEARINGS: BRONZE
ACTUATOR: STANDARD ROTORK HIGH SPEED
SI-1-Q SERIES INTERFACE
OPTION: CUSTOM ACTUATOR MOUNTING KIT
OPTION: ELECTRIC ACTUATOR
OPTION: PNEUMATIC ACTUATOR
LOCKOUT: 1/2° INTERVALS
BLADE OPENS: CCW
10"
NOTE: All fittings with standard Fab-Tech STD
connections include gaskets and clamps or
5"
hardware as required for installation. STD

"D"

BLADE STOP

REV: 12/01/17 CAT036EA

Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®

37 CONTROL DEVICES
2" & 3" EZ Blastgate

NOTE
All fittings with standard Fab-Tech connections
include gaskets and clamps or hardware as
required for installation.
SPECIFICATIONS
Stainless steel frame material.
Blade lockout system.

PART NO.* DESCRIPTION "D" "L"


PZB02H 2" EZ-BLASTGATE HORIZONTAL 2" 8.000”
PZB03H 3" EZ-BLASTGATE HORIZONTAL 3" 8.000”

"L" 8.5"

"D" 8.5"

PART NO.* DESCRIPTION "D" "L"


PZB02V 2" EZ-BLASTGATE VERTICAL 2" 8.000”
PZB03V 3" EZ-BLASTGATE VERTICAL 3" 8.000”

"D" 8.5"

"L"

REV: 12/01/17 CAT037EA

Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®

CONTROL DEVICES 38
4"-36" Horizontal Run Isolation Blastgate

NOTE
All fittings with standard Fab-Tech
connections include gaskets and WITH JOINT SYSTEM
clamps or hardware as required for EZ CLAMP 4" - 14"
installation.
SS CAST RING 4" - 14"
SPECIFICATIONS BI ANGLE RING 4" - 36"
Stainless steel frame material. SS ANGLE RING 16" - 36"
Blade lockout system.

DUCT DIA. OUTSIDE DIM BODY NO. OF


"D" "L1" BODY BLADE BOLTS BLADES
4" TO 16" DIA. "D" + 4" 18GA 18GA .31" 1
18" TO 36" DIA. "D" + 4.5" 16GA 16GA .31" 1

UPPER ANGLE
BODY RING

STAINLESS
STEEL BLADE

PTFE WIPER
( TYP BOTH SIDES
LOWER OF BLADE )
BODY 8"
STD

"D"

BLADE
"L1" LOCKOUT
( SEE CHART ) (STD)

REV: 12/01/17 CAT038EA

Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®

39 CONTROL DEVICES
16"-36" Horizontal Run Actuated Isolation Blastgate

NOTE
All fittings with standard Fab-Tech
connections include gaskets and
clamps or hardware as required for
installation.
SPECIFICATIONS
Stainless steel frame material.
Blade lockout system.
Exterior position indicator.
OPTIONS
Bellows enclosed lead screw for RING TYPES
additional corrosion resistance BI ANGLE RING 16" - 36"
( adds to L1 length ) SS ANGLE RING 16" - 36"

DUCT DIA. OUTSIDE DIM BODY NO. OF


"D" "L1" BODY BLADE BOLTS BLADES
16" TO 36" 2"D" + 30" 10GA 12GA .38" 1

CHAIN
WHEEL
"L1" ACTUATOR
2 x "D" + 30"

SINGLE
BLADE

D1 D2

"D"

"L2" 18"
"D" + 12.5"
REV: 12/01/17 CAT039EA

Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®

CONTROL DEVICES 40
38" & Larger Horizontal Run Isolation Blastgate

NOTE
All fittings with standard Fab-Tech connections include gaskets and
clamps or hardware as required for installation.
Blastgates 86" diameter and larger subject to engineering review and approval.
SPECIFICATIONS
Stainless steel body, rings and blade. WITH JOINT SYSTEM
Blade lockout system.
BI ANGLE RING 38" - 100"
SS ANGLE RING 16" - 120"

DUCT DIA. OUTSIDE DIM BODY NO. OF


"D" "L1" BODY BLADE COLLAR BOLTS BLADES
38" TO 46" DIA. "D" + 10" 10GA 14GA 14GA .31" 2
48" TO 60" DIA. "D" + 11" 10GA 12GA 14GA .38" 2
62" TO 84" DIA. "D" + 11" 10GA 12GA 14GA .38" 3
*86" TO 96" DIA. "D" + 11" 10GA 10GA 12GA .50" 3
*98" and UP DIA. "D" + 11" 3/16 10GA 10GA .63" 4
* Blastgates 86" diameter and larger subject to engineering review and approval.

ANGLE
UPPER BODY COLLAR RING
PTFE WIPER
( TYP BOTH SIDES
SPACER OF BLADE)
BLADE
BLADE 8"
LOWER BODY COLLAR STD
LOCKOUT
(STD)

BLADE

"D"

"L1"
( SEE CHART )

REV: 12/01/17 CAT040EA

Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®

41 CONTROL DEVICES
38" & Larger Horizontal Run Actuated Isolation Blastgate
NOTE
All fittings with standard Fab-Tech connections include gaskets and
clamps or hardware as required for installation.
Blastgates 90" diameter and larger subject to engineering review and approval.
SPECIFICATIONS
Stainless steel body, rings and blade.
Blade lockout system. RING TYPES
Exterior position indicator. BI ANGLE RING 38" - 100"
OPTIONS SS ANGLE RING 38" - 120"
Bellows enclosed lead screw for additional
corrosion resistance ( adds to L1 length )

DUCT DIA. OUTSIDE DIM BODY NO. OF


"D" "L1" BODY BLADE BOLTS BLADES
38" TO 64" 2"D" + 30" 10GA 12GA .38" 1
66" TO 88" 2"D" + 30" 10GA 12GA .43" 1

* Blastgates 90" diameter and larger subject to engineering review and approval.

CHAIN
WHEEL
"L1" ACTUATOR
2 x "D" + 30"

D1 D2

"D"

"L2" 18"
"D" + 12.5"

1REV: 12/01/17 CAT041EA

Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®

CONTROL DEVICES 42
4"-36" Vertical Run Isolation Blastgate
NOTE
All fittings with standard Fab-Tech connections include gaskets
and clamps or hardware as required for installation.
SPECIFICATIONS
Stainless steel body, rings and blade.
Blade lockout system.

"D"

WITH JOINT SYSTEM


BLADE
LOCKOUT EZ CLAMP 4" - 14"
(STD) SS CAST RING 4" - 14"
BI ANGLE RING 4" - 48"
SS ANGLE RING 16" - 120"

STAINLESS
STEEL BLADE

"L1"
( SEE CHART )
ANGLE
PTFE WIPER RING
( TYP BOTH SIDES
OF BLADE )

UPPER
BODY
"L2"
15° ( SEE CHART )

LOWER
BODY

DUCT DIA. OUTSIDE DIM FRAME NO. OF BLADE LENGTH


"D" "L1" BODY BLADE BOLTS BLADES ANGLE "L2"
4" TO 8" DIA. "D" + 4" 18GA 18GA .31" 1 15° 8"
10" TO 16" DIA. "D" + 4" 18GA 18GA .31" 1 15° 12"
18" TO 36" DIA. "D" + 4.5" 16GA 16GA .31" 1 15° 16"

REV: 12/01/17 CAT042EA

Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®

43 CONTROL DEVICES
16"-36" Vertical Run Actuated Isolation Blastgate

NOTE
All fittings with standard Fab-Tech connections include gaskets
and clamps or hardware as required for installation.
SPECIFICATIONS
Stainless steel frame material.
Blade lockout system.
Exterior position indicator.
OPTIONS
Bellows enclosed lead screw for additional
corrosion resistance ( adds to L1 length )

RING TYPES
BI ANGLE RING 16" - 36"
SS ANGLE RING 16" - 36"

"L1"
2 x "D" + 30"

"L3"
"D" + 12.5"

"D"

"D1"

24"
CHAIN
WHEEL
ACTUATOR

"D2"

DUCT DIA. OUTSIDE DIM FRAME NO. OF BLADE


"D" "L1" BODY BLADE BOLTS BLADES ANGLE
16" TO 36" 2"D" + 30" 10GA 12GA .38" 1 10°

REV: 12/01/17 CAT043EA

Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®

CONTROL DEVICES 44
38" & Larger Vertical Run Isolation Blastgate
NOTE
All fittings with standard Fab-Tech connections include gaskets
and clamps or hardware as required for installation.
Blastgates 86" diameter and larger are subject to engineering
review and approval.
SPECIFICATIONS
Stainless steel body, rings and blade.
Blade lockout system.
Vertical run blastgates greater than 84" require engineering
review and approval.

BLADE "D"
LOCKOUT WITH JOINT SYSTEM
(STD)
BI ANGLE RING 38" - 100"
SS ANGLE RING 38" - 120"

BLADE

BLADE

PTFE WIPER
( TYP BOTH SIDES "L1"
OF BLADE) ANGLE
RING ( SEE CHART )

COLLAR
10° BLADE "L2"
UPPER
LOWER BODY BODY ( SEE CHART )
COLLAR
SPACER

DUCT DIA. OUTSIDE DIM BODY NO. OF BLADE LENGTH


"D" "L1" BODY BLADE COLLAR BOLTS BLADES ANGLE "L2"
38" TO 46" DIA. "D" + 10" 10GA 14GA 14GA .31" 2 10° 16"
48" TO 60" DIA. "D" + 11" 10GA 12GA 14GA .38" 2 10° 24"
62" TO 84" DIA. "D" + 11" 10GA 12GA 14GA .38" 3 10° 24"
* Blastgates 86" diameter and larger are subject to engineering review and approval.

REV: 12/01/17 CAT044EA

Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®

45 CONTROL DEVICES
38" & Larger Vertical Run Actuated Isolation Blastgate
NOTE
All fittings with standard Fab-Tech connections include gaskets
and clamps or hardware as required for installation.
Blastgates 90" diameter and larger are subject to engineering
review and approval.
SPECIFICATIONS
Stainless steel body, rings and blade.
Blade lockout system.
Exterior position indicator.
OPTIONS
Bellows enclosed lead screw for additional
corrosion resistance ( adds to L1 length )
RING TYPES
BI ANGLE RING 38" - 100"
SS ANGLE RING 38" - 120"

"L1"
2 x "D" + 30"

"L3"
"D" + 12.5"

"D"

"D1"

24"
CHAIN
WHEEL
ACTUATOR

"D2"
DUCT DIA. OUTSIDE DIM BODY NO. OF BLADE
"D" "L1" BODY BLADE COLLAR BOLTS BLADES ANGLE
38" TO 64" 2"D" + 30" 10GA 12GA 12GA .38" 1 10°
66" TO 88" 2"D" + 30" 10GA 12GA 12GA .43" 1 10°
* Blastgates 90" diameter and larger are subject to engineering review and approval.
REV: 12/01/17 CAT045EA

Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®

ACCESSORIES 46
Product Guide

FIELD INSTALLED FIELD INSTALLED


NIPPLE TEST PORT
ACCESSORIES
SIZE: 1", 1-1/2", 2" SIZE: 3/8", 3/4", 2"
PAGE: 47 PAGE: 48
FIELD INSTALLED FIELD INSTALLED CAST RING
SADDLE TAP HOT TAP STAINLESS STEEL

SIZE: 4"-24" TEE SIZE: 4"-24" SIZE: 4"-14"


PAGE: 49 PAGE: 50 PAGE: 51
ANGLE RING
STAINLESS STEEL
OR BLACK IRON

SIZE: 4"-120"
PAGE: 52

FIELD INSTALLED CLAMP


SADDLE TAP
ACCESSORIES
PSP-EZ™
SIZE: 4" TO 14" TEE SIZE: 2" & 3"
PAGE: 49 PAGE: 53
DIE CUT GASKET CLAMP KIT CLAMP KIT

SIZE: 2" & 3" SIZE: 2" & 3" SIZE: 4" TO 14"
PAGE: 53 PAGE: 53 PAGE: 53

REV: 12/01/17 CAT046EA

Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®

47 ACCESSORIES
Field Installed Nipple
DIE-CUT GASKET

NOTES
Refer to Fab-Tech's INSTALLATION AND
ASSEMBLY GUIDE for assembly instructions.

PART NO. DESCRIPTION MIN. HOST DUCT MATERIAL THICKNESS


PRT01 1" NPT NIPPLE 6" DIA. DUCT MIN.
16 GA MAX
PRT15 1-1/2" NPT NIPPLE 8" DIA. DUCT MIN. MATERIAL
THICKNESS
PRT02 2" NPT NIPPLE 10" DIA. DUCT MIN.

DUCT
PTFE DIE-CUT GASKET

STRAIGHT
JAM PIPE THREAD 1-1/2"
NUT
TAPER
PIPE THREAD
NIPPLE

*SWAGE KIT REQUIRED TO INSTALL


ONLY ONE KIT REQUIRED TO INSTALL MULTIPLE NIPPLES

PART NO.* DESCRIPTION


TPS01 MANUAL KIT FOR 1"
TPS02 HYDRAULIC KIT FOR 1", 1-1/2", & 2"

REV: 12/01/17 CAT047EA

Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®

ACCESSORIES 48
Field Installed Test Port

HEX NUT

TEST
PORT
NPT
HANDLE
SEAL
(REMOVABLE)

TO COMPLETE THE INSTALLATION,


SIMPLY REMOVE THE STEM TO EXPOSE
THE PORT AND ATTACH FITTING OR LINE.

PART NO. DESCRIPTION MIN. HOST DUCT THRU HOLE REDRILL I.D. TAP HOLE
FTFI38TP 3/8" TEST PORT 2" DIA. DUCT MIN. 1/4" DIA. 3/8" MAX 1/16" NPT
FTFI34TP 3/4" TEST PORT 6" DIA. DUCT MIN. 1/2" DIA. 3/4" MAX 1/4" NPT
FTFI20TP 2" TEST PORT 12" DIA. DUCT MIN. 9/16" DIA. 1-3/4" MAX 3/8" NPT

SPECIFICATIONS
.75"
Nipple made of pure PVDF, seal made of Viton®
SEAL Stainless steel hex nut
Able to re-drill through hole to slightly larger hole or
drill and tap test port for female threads - thread O.D.
cannot exceed max re-drill diameter
DUCT Installs in duct as small as 2" diameter - provides
APPROX. liquid tight seal - does not compromise the integrity
1-3/4" of the duct interior coating
HEX NUT
NOTES
Refer to Fab-Tech's INSTALLATION AND
ASSEMBLY GUIDE for assembly instructions.
3/8" TEST PORT
The unique handle design of this test port allows it to
be installed quickly and easily in-the-field with common
tools and without system shutdown or disassembly.

FTFI38TP
FTFI34TP FTFI20TP

REV: 12/01/17 CAT048EA

Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®

49 ACCESSORIES
Field Installed Saddle Tap

NOTES
All fittings with standard Fab-Tech connections include gaskets
and clamps or hardware as required for installation.
Refer to Fab-Tech's INSTALLATION AND ASSEMBLY GUIDE
for assembly instructions.
Straight tap standard - other tap styles available with engineering
review and approval.
Fab-Tech's PSP® saddle tap will allow a new branch to be
installed without shutting down the exhaust system.
WITH JOINT SYSTEM
EZ CLAMP 4" - 14"
HOST DUCT I.D., WALL SS CAST RING 4" - 14"
THICKNESS & MATERIAL TYPE
( REQUIRED INFORMATION ) BI ANGLE RING 4" - 100"
SS ANGLE RING 16" - 120"

D1 SECTION THROUGH DUCT - STRAIGHT TAP

STUDS AND NUTS


6"
STD EXTERIOR
SADDLE

D2 HOST DUCT PTFE GASKET

FLUOROPOLYMER COATED
THREADED CAPS WELDED
TO PSP® SADDLE TAP
SECTION THROUGH DUCT - BOOT TAP
D1

45°
9"
STD 6"
STD

SECTION THROUGH DUCT - LATERAL TAP

D1 6"
STD

REV: 12/01/17 CAT049EA

Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®

ACCESSORIES 50
Field Installed Hot Tap

NOTES
All fittings with standard Fab-Tech connections include gaskets
and clamps or hardware as required for installation.
Refer to Fab-Tech's INSTALLATION AND ASSEMBLY GUIDE
for assembly instructions.
Only straight tap available for this tap configuration.
Fab-Tech's PSP® Field Installed Hot Tap
will allow a new branch to be installed in
an existing system without shutting down
the exhaust system.
Isolation box required for installation.

Allowable Tap Sizes


Tap Dia.
4 6 8 10 12 14 16 18 20 22 24
36 WITH JOINT SYSTEM
34
SS CAST RING 4" - 14"
32
BI ANGLE RING 4" - 24"
30
SS ANGLE RING 4" - 24"
Host Duct Dia.

28
26
24 SECTION THROUGH DUCT - HOT TAP
22
20 6"
18 STD End Cap
16 D2 Host Duct
14
12
10

PTFE Gasket
D1

Backing Ring

Fluoropolymer Coated
Threaded Caps Welded Anchor Bolt
to Backing Ring
HOST DUCT I.D., PRESSURE
CLASS & MATERIAL TYPE
( REQUIRED INFORMATION )

REV: 12/01/17 CAT050EA

Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®

51 ACCESSORIES
Cast Ring

CAST RING SPECIFICATIONS


NOTES:
DUCT DIA

DUCT DIA
THICKNESS

BOLT HOLE
# HOLES

Cast rings available in stainless.


CIRCLE
HEIGHT
WIDTH

BOLT
BOLT
SIZE
SIZE

DIA.
(W)

(H)

(T)

Refer to chart for standard cast rings.


"D" "D" All fittings with standard Fab-Tech connections
include gaskets and clamps or hardware as
4 5.31 4
6
6 7/16 7.50 6
required for installation.
1-1/4 13/32 1/8 x 3/8
8 11/16 9.50 8
8
10 11.50 10
12 9/16 13.81 12
1-1/2 1/2 3/16 12 x 1/2
14 3/4 15.81 14
H RING HEIGHT (SEE CHART)
T RING THICKNESS (SEE CHART)

DUCT
PART NO. DESCRIPTION DIA. RING
W
WIDTH
RC04 STEEL CAST RING 4"
RC06 STEEL CAST RING 6"
RC08 STEEL CAST RING 8"
RC10 STEEL CAST RING 10"
RC12 STEEL CAST RING 12"
RC14 STEEL CAST RING 14”

DUCT
DIA
"D"

REV: 12/01/17 CAT051EA

Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®

ACCESSORIES 52
Angle Ring

ANGLE RING SPECIFICATIONS


DUCT DIA

DUCT DIA
THICKNESS

BOLT HOLE
# HOLES

CIRCLE
WIDTH

BOLT
BOLT
SIZE
SIZE

DIA.
(W)

(T)

"D" "D"
4 1 7/16 5.31 4
6
6 7/16 7.50 6
1/8 3/8
8 1-1/4 x 9.50 8
8 11/16
10 11.50 10
12 13.81 12
12
14 15.81 14
16 17.63 16
16 BI ANGLE RING 4" - 100"
18 1-1/2 19.63 18
20 21.63 20
SS ANGLE RING 16" - 120"
22 20 23.88 22
24 25.88 24
26 27.88 26
24
28 29.88 28 NOTES:
30 31.88 30
28
32 33.88 32 Standard mounting hole locations for welded
34 35.88 34 (fixed) angle rings straddle the vertical centerline
3/16 32
36 37.88 36
38
2
40.38 38
unless otherwise specified.
36
40 42.38 40 Refer to chart for standard angle rings.
42 44.38 42
40 All fittings with standard Fab-Tech connections include
44 46.38 44
46
44
48.38 46 gaskets and clamps or hardware as required for
48 50.38 48 installation.
50 52.88 50
48
52 54.88 52 OPTIONS:
54 56.88 54
2-1/2 52
56 58.88 56 Custom hole pattern and orientation available.
58 60.88 58
56
60 62.88 60
62 64.88 62
60
64 9/16
x
66.88 64 W RING WIDTH
66 1/2 68.88 66
64 3/4
68 70.88 68 T RING THICKNESS
70 SLOT 72.88 70
68
72 74.88 72
74 76.88 74
72
76 78.88 76
78 3 80.88 78 W
76
80 82.88 80
82 84.88 82
80
84 86.88 84
86 89.38 86
84
88 91.38 88
90 1/4 93.38 90
88
92 95.38 92
94 97.38 94
92
96 100.38 96
98 102.38 98
96
100 104.38 100
102 106.38 102
100
104 108.38 104
106 110.38 106
104
108 4 112.38 108
110 114.38 110 DUCT
108 DIA
112 116.38 112
114
112
118.38 114 "D"
116 120.38 116
118 122.38 118
116
120 124.38 120
REV: 12/01/17 CAT052EA

Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®

53 ACCESSORIES
PSP-EZ™ Clamp Kit

CLAMP CLAMP
FASTENER NUT

DUCT DUCT
FLANGE FLANGE

DUCT DUCT DIE CUT GASKET

CROSS SECTION OF
2" & 3" PSP-EZ™ JOINT

PART NO. DESCRIPTION DUCT DIA.


CL002KT 2" CLAMP KIT 2"
CL003KT 3" CLAMP KIT 3"
CL002 2" CLAMP 2"
CL003 3" CLAMP 3"
GAS11 2" GASKET 2" NOTE
GAS13 3" GASKET 3" All fittings with standard Fab-Tech connections include
gaskets and clamps or hardware as required for installation.
Each Kit above contains a clamp and PTFE die
cut gasket
FASTENER NUT

CLAMP
CLAMP

FLOATING FLOATING
BACKING BACKING
RING RING

The PSP-EZ™ joining system


®
DUCT DUCT is available for standard PSP
CROSS SECTION OF duct from 2" to 14" in diameter.
4"-14" PSP-EZ™ JOINT The combination of half round
backing rings and the unique
PART NO. DESCRIPTION DUCT DIA.
angled clamp band provides
excellent clamping force with
CL004KT 4" CLAMP KIT 4" the added benefit of ease of
CL006KT 6" CLAMP KIT 6" installation.
CL008KT 8" CLAMP KIT 8"
CL010KT 10" CLAMP KIT 10"
CL012KT 12" CLAMP KIT 12"
CL014KT 14" CLAMP KIT 14"

Each Kit above contains a clamp, PTFE tape


gasket, and two backing rings

REV: 12/01/17 CAT053EA

Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®

2" & 3" EZ FITTINGS 54


Product Guide

STRAIGHT DUCT STRAIGHT TEE


4' LENGTH OR
2" & 3" CUSTOM
PSP-EZ™ CLAMP
SIZE: 2" & 3" SIZE: 2" & 3"
PAGE: 55 PAGE: 55
REDUCING TEE DOUBLE TEE LATERAL - 45°

SIZE: 3" TO 2" SIZE: 2" & 3" SIZE: 2" & 3"
PAGE: 55 PAGE: 56 PAGE: 56
ELBOW ELBOW ELBOW
90° 45° 30°

SIZE: 2" & 3" SIZE: 2" & 3" SIZE: 2" & 3"
PAGE: 56 PAGE: 57 PAGE: 57
ECCENTRIC CONCENTRIC VAN STONE TO
ADAPTER ADAPTER EZ FLANGE
ADAPTER
SIZE: 3" TO 2" SIZE: 3" TO 2" SIZE: 3" TO 2"
4" TO 2", 4" TO 3" 4" TO 2", 4" TO 3" 4" TO 2", 4" TO 3"
PAGE: 57 PAGE: 58 PAGE: 58
END CAP MICRO FIELD INSTALL
ADJUSTABLE STRAIGHT DUCT
DAMPER FLANGE

SIZE: 2" & 3" SIZE:2" & 3" SIZE: 2" & 3"
PAGE: 58 PAGE: 59 PAGE: 60
BLASTGATE

SIZE: 2" & 3"


PAGE: 61

REV: 12/01/17 CAT054EA

Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®

55 2" & 3" EZ FITTINGS


EZ Straight
"L"
"D"

PART NO. DESCRIPTION "D" "L"


PZP002 2" LINE 2" 47.25"
PZS002 2" LINE CUSTOM LENGTH 2" CUSTOM
PZP003 3" LINE 3" 47.25"
PZS003 3" LINE CUSTOM LENGTH 3" CUSTOM
All fittings with standard Fab-Tech connections include gaskets and clamps or hardware as required for installation.

EZ Tee
"D2"
"L2"

"D1" "L3"

"L1"

PART NO. DESCRIPTION "D1" "D2" "L1" "L2" "L3"


02T02 2" LINE WITH 2" TEE 2" 2" 6.24" 3.12" 3.12"
03T03 3" LINE WITH 3" TEE 3" 3" 6.74" 3.37" 3.37"
All fittings with standard Fab-Tech connections include gaskets and clamps or hardware as required for installation.

EZ Reducing Tee

"D2"
"L2"

"L3"
"D1"

"L1"
PART NO. DESCRIPTION "D1" "D2" "L1" "L2" "L3"
03T02 3" LINE WITH 2" TEE 3" 2" 6.74" 3.37" 3.62"
All fittings with standard Fab-Tech connections include gaskets and clamps or hardware as required for installation.

REV: 12/01/17 CAT055EA

Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®

2" & 3" EZ FITTINGS 56


EZ Double Tee
"D2"
"L2"

"L3"
"D1"

"L1"

PART NO. DESCRIPTION "D1" "D2" "L1" "L2" "L3"


2T2T2 2" LINE W/ DOUBLE 2" TEE 2" 2" 6.24" 3.12" 3.12"
All fittings with standard Fab-Tech connections include gaskets and clamps or hardware as required for installation.

EZ Lateral

"L1"
"D2"

"D1" 45°

"L2" "L1"

PART NO. DESCRIPTION "D1" "D2" "L1" "L2"


02Y02 2" LINE WITH 2" LATERAL 2" 2" 7.50" 2.00"
03Y03 3" LINE WITH 3" LATERAL 3" 3" 9.31" 2.03"
All fittings with standard Fab-Tech connections include gaskets and clamps or hardware as required for installation.

90° EZ Elbow

"L"
"D"

"L"
PART NO. DESCRIPTION "D" "L" R
PZE02 2" 90º ELBOW 2" 3.12" 2"
PZE03 3" 90º ELBOW 3" 4.62" 3"
All fittings with standard Fab-Tech connections include gaskets and clamps or hardware as required for installation.

REV: 12/01/17 CAT056EA

Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®

57 2" & 3" EZ FITTINGS


45° EZ Elbow
R

"D"

"L"

"L"

PART NO. DESCRIPTION "D" "L" R


PZ502 2" 45º ELBOW 2" 1.37" 2"
PZ503 3" 45º ELBOW 3" 2.00" 3"
All fittings with standard Fab-Tech connections include gaskets and clamps or hardware as required for installation.

30° EZ Elbow
R

"D"

"L"
"L"

PART NO. DESCRIPTION "D" "L" R


PZ302 2" 30º ELBOW 2" 1.94" 2"
PZ303 3" 30º ELBOW 3" 2.38" 3"
All fittings with standard Fab-Tech connections include gaskets and clamps or hardware as required for installation.

Eccentric EZ Reducer

"D2"
"D1" "L2"

"L1"

PART NO. DESCRIPTION "D1" "D2" "L1" "L2"


PEA32F 2" TO 3" ECCENTRIC 2" 3" 8.25" 0.50"
PEA42F 2" TO 4" ECCENTRIC 2" 4" 12.75" 1.00"
PEA43F 3" TO 4" ECCENTRIC 3" 4" 8.00" 0.50"
All fittings with standard Fab-Tech connections include gaskets and clamps or hardware as required for installation.

REV: 12/01/17 CAT057EA

Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®

2" & 3" EZ FITTINGS 58


Concentric EZ Reducer
"D1"

"D2"

"L1"
PART NO. DESCRIPTION "D1" "D2" "L1"
PCA32F 2" TO 3" CONCENTRIC 2" 3" 4.31"
PCA42F 2" TO 4" CONCENTRIC 2" 4" 3.94"
PCA43F 3" TO 4" CONCENTRIC 3" 4" 4.31"
All fittings with standard Fab-Tech connections include gaskets and clamps or hardware as required for installation.

Angle Ring to EZ Reducer


"D3"
"D1"

"D2"

"D4"
"L1" BOLT CIRCLE DIA.

PART NO. DESCRIPTION "D1" "D2" "L1" "D3" O.D. "D4" DIA.
PCA32R 2" TO 3" ANGLE RING 2" 3" 4.25" 5.06" 4.31"
PCA42R 2" TO 4" ANGLE RING 2" 4" 3.88" 6.06" 5.31"
PCA43R 3" TO 4" ANGLE RING 3" 4" 4.25" 6.06" 5.31"
All fittings with standard Fab-Tech connections include gaskets and clamps or hardware as required for installation.

EZ End Cap

"D"

"L"

PART NO. DESCRIPTION "D" "L"


PZC02 2" END CAP 2" 0.21"
PZC03 3" END CAP 3" 0.21"
All fittings with standard Fab-Tech connections include gaskets and clamps or hardware as required for installation.

REV: 12/01/17 CAT058EA

Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®

59 2" & 3" EZ FITTINGS


Micro-Adjustable EZ Damper

PART NO. DESCRIPTION "D" "L"


PZD02 2" EZ-DAMPER 2" 3.875"
PZD03 3" EZ-DAMPER 3" 3.875"
All fittings with standard Fab-Tech connections include gaskets and clamps
or hardware as required for installation.

"L"
POSITION LOCK
ACTUATOR
THUMB WHEEL PLATE
FRICTION WHEEL

"D"

REV: 12/01/17 CAT059EA

Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®

2" & 3" EZ FITTINGS 60


Field Installed Straight Duct EZ Flange

NOTES
All fittings with standard Fab-Tech connections include
gaskets and clamps or hardware as required for installation.
PermaShield fluoropolymer barrier coating on interior and exterior
surfaces.
Requires purchase of Pressing Wheel, Part #D0700 for installation.
The pressing wheel is used to press a bead around the duct to
complete the installation. Wheel fits Ridgid Pipe Cutter Model 3S.
Refer to Fab-Tech's INSTALLATION AND ASSEMBLY GUIDE
for assembly instructions.

PART NO. DESCRIPTION "D" "L1"


HTB02 2" FIELD FLANGE 2" 2"
HTB03 3" FIELD FLANGE 3" 2"

FOR USE ON EZ STRAIGHT DUCT ONLY


NOT DESIGNED FOR EZ ELBOWS, TEES, OR REDUCERS

REPLACEMENT FLANGE FOR 2" & 3" STRAIGHT DUCT MODIFIED


OR CUT TO LENGTH IN THE FIELD
REFER TO INSTALLATION AND ASSEMBLY GUIDE

"O" RING
PRESSED
AUXILIARY BEAD
FLANGE DUCT
"D"

"L1"

REV: 12/01/17 CAT060EA

Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®

61 2" & 3" EZ FITTINGS


EZ Blastgate

NOTE
All fittings with standard Fab-Tech connections include
gaskets and clamps or hardware as required for installation.

SPECIFICATIONS
Stainless steel frame material.
Blade lockout system.

PART NO. DESCRIPTION "D" "L"


PZB02H 2" EZ-BLASTGATE HORIZONTAL 2" 8.000”
PZB03H 3" EZ-BLASTGATE HORIZONTAL 3" 8.000”

"L" 8.5"

"D" 8.5"

PART NO. DESCRIPTION "D" "L"


PZB02V 2" EZ-BLASTGATE VERTICAL 2" 8.000”
PZB03V 3" EZ-BLASTGATE VERTICAL 3" 8.000”

"D" 8.5"

"L"

REV: 12/01/17 CAT061EA

Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®

FAB-TECH FLANGE SYSTEM 62


Product Guide

SPRINKLER KF FLANGE DWYER SWAGELOK® NPT FEMALE NPT MALE


ADAPTER ADAPTER PITOT ADAPTER NIPPLE NIPPLE ADAPTER
ADAPTER ADAPTER
SIZE: SIZE: SIZE: SIZE:
2" & 3" 2" TO KF 25 SIZE: 2" TO 1/8" SWAGELOK
®
SIZE: 2" TO 1/8" NPT
®
2" TO KF 40 2" & 3" 2" TO 1/4" SWAGELOK 2" TO 1/8" NPT 2" TO 1/4" NPT
®
2" TO KF 50 2" TO 3/8" SWAGELOK 2" TO 1/4" NPT 2" TO 3/8" NPT
2" TO 1/2" SWAGELOK® 2" TO 3/8" NPT 2" TO 1/2" NPT
2" TO 3/4" SWAGELOK® 2" TO 1/2" NPT 2" TO 3/4" NPT
2" TO 3/4" NPT 2" TO 1" NPT
2" TO 1" NPT 2" TO 1-1/2" NPT
2" TO 1-1/2" NPT 2" TO 2" NPT
PAGE: 73 2" TO 2" NPT 3" TO 3" NPT
PAGE: 72 4" TO 4" NPT
PAGE: 68
PAGE: 71

PAGE: 70
PAGE: 69
Duct

FIELD INSTALLED WELDED FIELD INSTALLED


FAB-TECH FAB-TECH FAB-TECH FLANGE
FLANGE FLANGE SADDLE TAP
SIZE: SIZE:
2" ONLY 2" & 3" SIZE:
2" & 3"

PAGE: 67
PAGE: 74 PAGE: 75

REV: 12/01/17 CAT062EA

Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®

63 FAB-TECH FLANGE SYSTEM


Fab-Tech Flange
NOTES
All fittings with standard Fab-Tech connections include
gaskets and clamps or hardware as required for installation. DUCT
Refer to Fab-Tech's INSTALLATION AND ASSEMBLY GUIDE
for assembly instructions.
PermaShield fluoropolymer barrier coating on inside
surface and flange faces.
Fab-Tech Flange / Test Port may be installed on fittings
other than straight duct.
Refer to the EZ fittings section for duct or the Fab-Tech
Flange system section for adapters to attach to the
Fab-Tech Flange.
FAB-TECH FLANGE
PART NO. DESCRIPTION "D" "L" ( WELDED TO DUCT )
FTFL2 2" FT FLANGE 2" .75"
FTFL3 3" FT FLANGE 3" .75"

DUCT
"D"

"L"
FAB-TECH
FLANGE

CLAMP

EZ DUCT
OR ADAPTER

ADAPTERS AVAILABLE FOR THE FT FLANGE:

Dwyer Pitot Adapter


NPT Male Nipple Sprinkler Adapter

KF Flange Adapter NPT Female Coupler SWAGELOK® Adapter

REV: 12/01/17 CAT063EA

Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®

FAB-TECH FLANGE SYSTEM 64


KF Flange Adapter

NOTES
All fittings with standard Fab-Tech connections include
gaskets and clamps or hardware as required for installation.
Refer to Fab-Tech's INSTALLATION AND ASSEMBLY GUIDE
for assembly instructions.
PermaShield fluoropolymer barrier coating on inside surface
and flange faces.
KF Adapters are only available for 2" Fab-Tech Flange
connection.

PART NO. DESCRIPTION KF "D" "L1"


FTK25 2" TO 25 KF FLANGE 25mm 2" 1.25"
FTK40 2" TO 40 KF FLANGE 40mm 2" 1.25"
FTK50 2" TO 50 KF FLANGE 50mm 2" 1.25"

"D" "D" "D"

"L1"

KF 25 KF 40 KF 50

REV: 12/01/17 CAT064EA

Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®

65 FAB-TECH FLANGE SYSTEM


NPT Male Nipple Adapter

NOTES
All fittings with standard Fab-Tech connections include
gaskets and clamps or hardware as required for installation.
Refer to Fab-Tech's INSTALLATION AND ASSEMBLY GUIDE
for assembly instructions.
PermaShield fluoropolymer barrier coating on inside surface
and flange face.
NPT nipples are not covered under warranty other than for
defects in manufacture. NPT threads are not coated and
since the threads could possibly come in direct contact with
corrosive fumes and fluids, Fab-Tech offers only a limited
warranty for these parts. Depending on the specific
application, NPT adapters should fall into the classification
of consumable parts.

PART NO. DESCRIPTION "D" PIPE THREAD "L1"

FTN18 2" TO 1/8" NPT 2" 1/8" NPT 1.25"


FTN14 2" TO 1/4" NPT 2" 1/4" NPT 1.25"
FTN38 2" TO 3/8" NPT 2" 3/8" NPT 1.25"
FTN12 2" TO 1/2" NPT 2" 1/2" NPT 1.25"
FTN34 2" TO 3/4" NPT 2" 3/4" NPT 1.25"
FTN01 2" TO 1" NPT 2" 1" NPT 1.25"
FTN15 2" TO 1.5" NPT 2" 1.5" NPT 1.25"
FTN02 2" TO 2" NPT 2" 2" NPT 2.25"
FTN03 3" TO 3" NPT 3" 3" NPT 2.50"
FTN04** 4" TO 4" NPT 4" 4" NPT 3.00"
**USED WITH 4" PSP-EZ™ TAP

"D" "D" "D" "D" "D" "D"

"L1"

FTN18 FTN14 FTN38 FTN12 FTN34 FTN01

"D" "D" "D" "D"

"L1"
"L1" "L1"
"L1"
FTN15

FTN02
FTN03
FTN04
USED WITH 4" PSP-EZ™ TAP

REV: 12/01/17 CAT065EA

Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®

FAB-TECH FLANGE SYSTEM 66


NPT Female Coupler Adapter

NOTES
All fittings with standard Fab-Tech connections include
gaskets and clamps or hardware as required for installation.
Refer to Fab-Tech's INSTALLATION AND ASSEMBLY GUIDE
for assembly instructions.
PermaShield fluoropolymer barrier coating on flange face.
NPT nipples are not covered under warranty other than for
defects in manufacture. NPT threads are not coated and
since the threads could possibly come in direct contact with
corrosive fumes and fluids, Fab-Tech offers only a limited
warranty for these parts. Depending on the specific
application, NPT adapters should fall into the classification
of consumable parts.

PART NO. DESCRIPTION "D" PIPE THREAD "L1"


FTF18 2" TO 1/8" NPT 2" 1/8" NPT .75"
FTF14 2" TO 1/4" NPT 2" 1/4" NPT .75"
FTF38 2" TO 3/8" NPT 2" 3/8" NPT .75"
FTF12 2" TO 1/2" NPT 2" 1/2" NPT .75"
FTF34 2" TO 3/4" NPT 2" 3/4" NPT .75"
FTF01 2" TO 1" NPT 2" 1" NPT 1.25"
FTF15 2" TO 1.5" NPT 2" 1.5" NPT 1.25"
FTF02 2" TO 2" NPT 2" 2" NPT 1.25"

"D" "D" "D" "D"

"L1" FTF18 FTF14 FTF38 FTF12

"D" "D" "D" "D"

"L1"
"L1" FTF34
FTF01 FTF15 FTF02

REV: 12/01/17 CAT066EA

Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®

67 FAB-TECH FLANGE SYSTEM


Swagelok® Adapter

NOTES
All fittings with standard Fab-Tech connections include
gaskets and clamps or hardware as required for installation.
Refer to Fab-Tech's INSTALLATION AND ASSEMBLY GUIDE
for assembly instructions.
PermaShield fluoropolymer barrier coating on flange face.
SWAGELOK® Adapters are not covered under warranty other
than for defects in manufacture. SWAGELOK® threads are not
coated and since the threads could possibly come in direct
contact with corrosive fumes and fluids, Fab-Tech offers only a
limited warranty for these parts. Depending on the specific
application, SWAGELOK® adapters should fall into the
classification of consumable parts.

PART NO. DESCRIPTION "D" THREAD "L1"


®
FTS18** 2" TO 1/8" SWAGELOK 2"
FTS14 2" TO 1/4" SWAGELOK® 2" 7/16-20 .59"
FTS38 2" TO 3/8" SWAGELOK® 2" 9/16-18 .65"
FTS12 2" TO 1/2" SWAGELOK® 2" 3/4-16 .77"
FTS34 2" TO 3/4" SWAGELOK® 2" 1-1/16-12 .77"
**FTS18 IS AVAILABLE AS A CUSTOM ADAPTER, NOT A STOCK ITEM

"D" "D" "D"

"L1" "L1"
"L1"

FTS14 FTS38 FTS12

"D"

"L1"

FTS34

REV: 12/01/17 CAT067EA

Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®

FAB-TECH FLANGE SYSTEM 68


Dwyer Pitot Adapter
NOTES
All fittings with standard Fab-Tech connections include
gaskets and clamps or hardware as required for installation.
Refer to Fab-Tech's INSTALLATION AND ASSEMBLY GUIDE
for assembly instructions.
PermaShield fluoropolymer barrier coating on inside surface
and flange faces.

PART NO. DESCRIPTION "D" "L1"


FTPT2 2" PITOT FLANGE 2" 0.88"
FTPT3 3" PITOT FLANGE 3" 0.88"

"D" "D"

"L1" "L1"
GASKET GASKET

FTPT2 FTPT3

VARIES ACCORDING TO
DIAMETER OF DUCT
(ADJUST AS NEEDED)

FAB-TECH
FLANGE
CLAMP
PITOT
ADAPTER

GASKET
"O" RING
SPLIT FLANGE MOUNTING KIT
DWYER #A-158
ALIGN PITOT TUBE DWYER PITOT TUBE
TO CENTER OF DUCT DWYER #160-8 TO #160-60
BY ADJUSTING TO FROM: DWYER INSTRUMENTS
MARKINGS ON TUBE www.dwyer-inst.com

REV: 12/01/17 CAT068EA

Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®

69 FAB-TECH FLANGE SYSTEM


Sprinkler Adapter

NOTES
All fittings with standard Fab-Tech connections include
gaskets and clamps or hardware as required for installation.
Refer to Fab-Tech's INSTALLATION AND ASSEMBLY GUIDE
for assembly instructions.
PermaShield fluoropolymer barrier coating on flange face and
o-ring surfaces.

PART NO. DESCRIPTION "D" "L1"


FTSP2 2" SPRINKLER FLANGE 2" 1.10"
FTSP3 3" SPRINKLER FLANGE 3" 2.00"

1" NPT
1" NPT

"L1" "L1"
"D"
"D"

1/2" NPT 1/2" NPT


FTSP2 FTSP3

WATER SUPPLY
CONNECTION
GASKET

CLAMP

FAB-TECH
FLANGE
"O" RING
(SECONDARY SEAL
AND TO HOLD
DUCT BAG IN PLACE)
"D"

SPRINKLER HEAD BAG USED TO PREVENT


(SPRINKLER HEAD AND BAG CORROSION OF
SUPPLIED BY OTHERS SPRINKLER HEAD
CALL FOR DETAILS)

REV: 12/01/17 CAT069EA

Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®

FAB-TECH FLANGE SYSTEM 70


Field Installed 2” Fab-Tech Flange

NOTES
All fittings with standard Fab-Tech connections include
gaskets and clamps or hardware as required for installation.
Refer to Fab-Tech's INSTALLATION AND ASSEMBLY GUIDE
for assembly instructions.
PermaShield fluoropolymer barrier coating on inside surface
and flange faces.
Requires Hydraulic Punch & Swage Kit (TPSO2) to
install - check accessories section.
Requires disassembly of duct to install this fitting.

PART NO. DESCRIPTION "D" "L1" HOST DUCT DIAMETER


FTFL2FI 2" FIELD FLANGE 2" 1.69" 10" DIAMETER MINIMUM

GASKET

DUCT
"L1" (10" DIA MIN)

LOCKING
RING

"D"

"D"

SPLIT LOCKING RING

REV: 12/01/17 CAT070EA

Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®

71 FAB-TECH FLANGE SYSTEM


Field Installed Fab-Tech Flange
Saddle Tap
INTERIOR
SADDLE
NOTES
EXTERIOR
All fittings with standard Fab-Tech connections include gaskets SADDLE
and clamps or hardware as required for installation.
Refer to Fab-Tech's INSTALLATION AND ASSEMBLY GUIDE
for assembly instructions.
PermaShield fluoropolymer barrier coating on inside surfaces
and flange face.
Fab-Tech's field installed PSP® saddle tap will allow a new
2" diameter branch to be installed in a 6" and larger diameter
duct or a new 3" diameter branch to be installed in an 8" and
larger diameter duct without shutting down the exhaust system.

PART NO. DESCRIPTION "D1" "D2"


PZQ02 2" EZ-TAP 2" 6" MIN
PZQ03 3" EZ-TAP 3" 8" MIN

THREADED AND COATED CAPS


WELDED TO PSP® SADDLE TAP

"D2" HOST DUCT


EXTERIOR SADDLE
STUDS AND NUTS
HOST DUCT I.D., WALL
THICKNESS & MATERIAL TYPE
( REQUIRED INFORMATION )
"D1"

INTERIOR SADDLE

2"
STD

PTFE GASKET

SECTION THROUGH DUCT

REV: 12/01/17 CAT071EA

Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®

RECTANGULAR DUCT 72
Product Guide

STRAIGHT DUCT STRAIGHT DUCT


WITH STRAIGHT
RECTANGULAR RECTANGULAR
DUCT TAP

PAGE: 74 PAGE: 74
STRAIGHT DUCT WITH STRAIGHT DUCT WITH STRAIGHT DUCT WITH
RECTANGULAR RECTANGULAR RECTANGULAR
BOOT TAP CONICAL TAP LATERAL TAP

PAGE: 75 PAGE: 75 PAGE: 76


STRAIGHT DUCT STRAIGHT DUCT RADIAL ELBOW
WITH ROUND WITH MULTIPLE 30°, 45°, 60°, 90°
TAP TAPS

PAGE: 76 PAGE: 77 PAGE: 78


MITERED ELBOW CONCENTRIC CONCENTRIC
30°, 45°, 60°, 90° TRANSITION RECTANGULAR
TO ROUND
TRANSITION

PAGE: 78 PAGE: 79 PAGE: 79


VERTICAL HORIZONTAL DOUBLE
OFFSET OFFSET OFFSET

PAGE: 80 PAGE: 80 PAGE: 81


END CAP

PAGE: 81

REV: 12/01/17 CAT072EA

Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®

73 RECTANGULAR DUCT
Mounting Flange Standards
CENTERLINE TO CENTERLINE
3” TO 4”
X

ANGLE IRON
MOUNTING
3” TO 4” FLANGE X
DUCT
CENTERLINE DEPTH
TO
CENTERLINE

Angle sizes (X): 1.5”, 2”, 2.5”, and 3.0”


Angle thickness for all sizes: 3/16”
DUCT WIDTH Flange angle size determined
from duct width and system pressure.

TABLE BELOW IS FOR STANDARD DUCT LENGTH OF 48-1/4"


S = STIFFENER ADDED

-6” W.G. -10” W.G. -14” W.G. -18” W.G.


DUCT DUCT ANGLE DUCT ANGLE DUCT ANGLE DUCT ANGLE
WIDTH GAUGE SIZE GAUGE SIZE GAUGE SIZE GAUGE SIZE
12" - 24" 16 1.5” 12 1.5” 12 1.5” 10 2”
26" - 36" 16 1.5” 12 2” 12 2” 10 2”
38" - 48" 16 2” 12 2” 12 2” 10 3.0”
50" - 60" 16 - S 2” 12 - S 2” 12 - S 2” 10 - S 2”
62" - 72" 16 - S 2” 12 - S 2” 12 - S 2” 10 - S 2”
74" - 84" 16 - S 2” 12 - S 2” 12 - S 2” 10 - S 2.5”
86" - 96" 16 - S 2” 12 - S 2” 12 - S 2.5” 10 - S 3.0”

NOTES
Flange material is stainless steel.
The number of holes for the bolt hole pattern is determined from the
duct width and depth. Hole to hole distance will be calculated to be
between 3" to 4". Oblong holes are punched along the flange centerline.
Duct width or depth of 98" and larger requires engineering review.
Interior stiffeners ( 1” SCH40 pipe ) are welded between duct sides 50" wide
or greater. Separate offset stiffeners are used when both duct width
and depth are 50" or greater.

REV: 12/01/17 CAT073EA

Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®

RECTANGULAR DUCT 74
Straight Duct
"X"
INTERIOR STIFFENER

"Y"

NOTE
"L1"
All fittings with standard Fab-Tech connections include MAX. 48-1/4"
gaskets and clamps or hardware as required for installation.
OPTIONS
Custom lengths available. LONGER THAN STANDARD LENGTHS AND/OR HIGHER
Raw end available. SYSTEM PRESSURES MAY REQUIRE ADDITIONAL
STIFFENERS PER SMACNA, CONTACT FAB-TECH FOR
Duct width or depth of 98" and larger requires SPECIFIC GUIDELINES.
Fab-Tech engineering review and approval.
An interior stiffener ( 1" SCH40 pipe ) is added at the
midpoint of the flange for duct width or depth
of 50" and greater.

Straight Duct with Straight Rectangular Tap


NOTE
All fittings with standard Fab-Tech connections include
gaskets and clamps or hardware as required for installation.
OPTIONS
Custom lengths available.
Raw end available.
Duct width or depth of 98" and larger requires
Fab-Tech engineering review and approval.
An interior stiffener ( 1" SCH40 pipe ) is added at the
midpoint of the flange for duct width or depth of 50" "L2"
and greater. MIN 6"

LONGER THAN STANDARD LENGTHS AND/OR HIGHER SYSTEM MIN 4" "TX"
PRESSURES MAY REQUIRE ADDITIONAL STIFFENERS PER MIN 4"
SMACNA, CONTACT FAB-TECH FOR SPECIFIC GUIDELINES.

"L4" "L3"
"L4" "L4" "L4"

"Y" "TY"

"L4" "L1" MAX. 48-1/4"


"X"
REV: 12/01/17 CAT074EA

Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®

75 RECTANGULAR DUCT
Straight Duct with Rectangular Boot Tap
NOTE
All fittings with standard Fab-Tech connections include gaskets and
clamps or hardware as required for installation.

OPTIONS
Custom lengths available.
Raw end available.
Duct width or depth of 98" and larger requires 6” 45°
Fab-Tech engineering review and approval. STD
An interior stiffener ( 1" SCH40 pipe ) is added at the
midpoint of the flange for duct width or depth of 50"
and greater.

LONGER THAN STANDARD LENGTHS AND/OR HIGHER SYSTEM "L2"


PRESSURES MAY REQUIRE ADDITIONAL STIFFENERS PER 9" STD MIN 4" "TX"
SMACNA, CONTACT FAB-TECH FOR SPECIFIC GUIDELINES. MIN 4"

"L4" "L3"
"L4" "L4" "L4"

"TY"
"Y"

"L4" "L1" MAX. 48-1/4"


"X"

Straight Duct with Rectangular Conical Tap


NOTE
All fittings with standard Fab-Tech connections include gaskets and
clamps or hardware as required for installation.
OPTIONS
Custom lengths available.
Raw end available.
Duct width or depth of 98" and larger requires
Fab-Tech engineering review and approval. 6” 45°
An interior stiffener ( 1" SCH40 pipe ) is added at the STD
midpoint of the flange for duct width or depth of 50"
and greater.

LONGER THAN STANDARD LENGTHS AND/OR HIGHER SYSTEM


PRESSURES MAY REQUIRE ADDITIONAL STIFFENERS PER "L2"
SMACNA CONTACT FAB-TECH FOR SPECIFIC GUIDELINES. 9" STD MIN 4" "TX" MIN 4"

"L4" "L3"
"L4" "L4" "L4"

"Y" "TY"

"L4" "L1" MAX. 48-1/4"


"X"
REV: 12/01/17 CAT075EA

Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®

RECTANGULAR DUCT 76
Straight Duct with Rectangular Lateral Tap
NOTE MIN 4"
All fittings with standard Fab-Tech connections include gaskets
and clamps or hardware as required for installation.
OPTIONS
Custom lengths available.
Raw end available.
Duct width or depth of 98" and larger requires Fab-Tech
engineering review and approval.
An interior stiffener ( 1" SCH40 pipe ) is added at the midpoint of
the flange for duct width or depth of 50" and greater.

LONGER THAN STANDARD LENGTHS AND/OR HIGHER SYSTEM 45° STD


PRESSURES MAY REQUIRE ADDITIONAL STIFFENERS PER "L3"
SMACNA, CONTACT FAB-TECH FOR SPECIFIC GUIDELINES. MIN 4"
"TX"
"L4" "L2"
"L4" "L4" "L4" 6” STD

"Y" "TY"

"L4" "L1" MAX. 48-1/4"


"X"

Straight Duct with Round Tap


NOTE
All fittings with standard Fab-Tech ROUND RING TYPES ("R")
connections include gaskets and
clamps or hardware as required EZ EZ CLAMPS
( AVAILABLE 4" - 14" )
for installation.
SC STAINLESS CAST RINGS
( AVAILABLE 4" - 14" )
OPTIONS
BI BLACK IRON ANGLE RINGS
( AVAILABLE 4" - 100" )
Custom lengths available.
Raw end available. SS STAINLESS ANGLE RINGS
( AVAILABLE 16" - 120" )
Duct width or depth of 98"
and larger requires Fab-Tech
engineering review and approval.
An interior stiffener ( 1" SCH40 pipe ) is added at the midpoint of "L2"
the flange for duct width or depth of 50" and greater. MIN 6"

LONGER THAN STANDARD LENGTHS AND/OR HIGHER SYSTEM MIN 4"


PRESSURES MAY REQUIRE ADDITIONAL STIFFENERS PER MIN 4"
SMACNA, CONTACT FAB-TECH FOR SPECIFIC GUIDELINES.

"L4" "DØ" "R"


"L3"
"L4" "L4" "L4"

"Y"

"L4" "L1" MAX. 48-1/4"


"X"
REV: 12/01/17 CAT076EA

Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®

77 RECTANGULAR DUCT
Straight Duct with Multiple Taps
6" STD
"TX"
1" MIN 6" STD
MIN 6" "TX" "TX" "TX" "R" "DØ"
4" 4"
"TX"
MIN MIN
"L2" "L2"
45°

STRAIGHT
"L3" TAP
4"
SHOE "L3" MIN
TAP
"L3" CONICAL TAP
"L3" ROUND TAP
"L3" 45° LATERAL TAP
"L1" MAX. 48-1/4"

"X"

"L2" "L2" "L5" "L2" ROUND RING TYPES ("R")


EZ EZ CLAMPS
( AVAILABLE 4" - 14" )
"L4"
TOP SC (STAINLESS CAST RINGS
AVAILABLE 4" - 14" )
BLACK IRON ANGLE RINGS
BI ( AVAILABLE 4" - 100" )

"Y" "TY" SS (STAINLESS ANGLE RINGS


AVAILABLE 16" - 120" )
"L4"

LONGER THAN STANDARD LENGTHS AND/OR HIGHER


SYSTEM PRESSURES MAY REQUIRE ADDITIONAL
STIFFENERS PER SMACNA, CONTACT FAB-TECH FOR
"L5" SPECIFIC GUIDELINES.
"L2"
END VIEW
NOTE
All fittings with standard Fab-Tech connections include gaskets and
clamps or hardware as required for installation.
OPTIONS
Custom lengths available.
Raw end available.
Duct width or depth of 98" and larger requires Fab-Tech engineering review and approval.
An interior stiffener ( 1" SCH40 pipe ) is added at the midpoint of the flange for duct width or depth of 50" and greater.

REV: 12/01/17 CAT077EA

Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®

RECTANGULAR DUCT 78
90°, 60°, 45°, 30° or Custom Elbow

"N"

"L1"

60° RADIAL 45° RADIAL 30° RADIAL


"Y" ELBOW ELBOW ELBOW

NOTE
All fittings with standard Fab-Tech connections include gaskets and
clamps or hardware as required for installation.
"X" OPTIONS
Raw end available.
Duct width or depth of 98" and larger requires Fab-Tech engineering
review and approval.
90° RADIAL An interior stiffener ( 1" SCH40 pipe ) is added at the midpoint of the
ELBOW flange for duct width or depth of 50" and greater.

90°, 60°, 45°, 30° or Custom Mitered Elbow

"L2"

"N"

90° MITERED 60° MITERED "L1" 30° MITERED


"X"
ELBOW ELBOW ELBOW

"Y"

45° MITERED
ELBOW

REV: 12/01/17 CAT078EA

Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®

79 RECTANGULAR DUCT
Concentric Transition
"X"

"T1" "L1"

"T2" "Y"
FOR ECCENTRIC RECTANGULAR
TO RECTANGULAR FITTING, USE
THE CUSTOM FITTING ORDER
SHEET.

NOTE
All fittings with standard Fab-Tech connections include gaskets and
clamps or hardware as required for installation.
OPTIONS
Raw end available.
Duct width or depth of 98" and larger requires Fab-Tech engineering
review and approval.
An interior stiffener ( 1" SCH40 pipe ) is added at the midpoint of the
flange for duct width or depth of 50" and greater.

Concentric Rectangular to Round Transition

ROUND RING TYPES "X" "L1"


EZ EZ CLAMPS
( AVAILABLE 4" - 14" )

SC STAINLESS CAST RINGS


( AVAILABLE 4" - 14" )
BLACK IRON ANGLE RINGS
BI ( AVAILABLE 4" - 100" )
"R" "DØ"
SS STAINLESS ANGLE RINGS
( AVAILABLE 16" - 120" ) "Y"

FOR ECCENTRIC RECTANGULAR


TO ROUND FITTING, USE THE
CUSTOM FITTING ORDER SHEET.
"L2"
NOTE 3" MIN
All fittings with standard Fab-Tech connections include gaskets and
clamps or hardware as required for installation.
OPTIONS
Raw end available.
Duct width or depth of 98" and larger requires Fab-Tech engineering
review and approval.
An interior stiffener ( 1" SCH40 pipe ) is added at the midpoint of the
flange for duct width or depth of 50" and greater.

REV: 12/01/17 CAT079EA

Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®

RECTANGULAR DUCT 80
Vertical Offset
CENTER OF "Y"
TO CENTER OF "L2"
OFFSET

"Y"

"X" "L1"

NOTE
All fittings with standard Fab-Tech connections include gaskets and
clamps or hardware as required for installation.
OPTIONS
Raw end available.
Duct width or depth of 98" and larger requires Fab-Tech engineering
review and approval.
An interior stiffener ( 1" SCH40 pipe ) is added at the midpoint of the
flange for duct width or depth of 50" and greater.

Horizontal Offset

CENTER OF "X"
TO CENTER OF "L2" "L1"
OFFSET

NOTE
All fittings with standard Fab-Tech connections
include gaskets and clamps or hardware as
required for installation.
"X"
OPTIONS
Raw end available.
Duct width or depth of 98" and larger requires
Fab-Tech engineering review and approval.
An interior stiffener ( 1" SCH40 pipe ) is added at
the midpoint of the flange for duct width or depth "Y"
of 50" and greater.

REV: 12/01/17 CAT080EA

Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®

81 RECTANGULAR DUCT
Double Offset

CENTER OF "X"
TO CENTER OF "L3"
OFFSET
CENTER OF "Y"
TO CENTER OF "L2"
OFFSET

"Y"

"X" "L1"
NOTE
All fittings with standard Fab-Tech connections include gaskets and
clamps or hardware as required for installation.
OPTIONS
Raw end available.
Duct width or depth of 98" and larger requires Fab-Tech engineering
review and approval.
An interior stiffener ( 1" SCH40 pipe ) is added at the midpoint of the
flange for duct width or depth of 50" and greater.

End Cap
STAINLESS STEEL
PLATE WELDED
TO FLANGE

"Y"

"X"

NOTE
All fittings with standard Fab-Tech connections include gaskets and
clamps or hardware as required for installation.
OPTIONS
Flange material will be stainless steel unless other material is specified.
Duct width or depth of 98" and larger requires Fab-Tech engineering
review and approval.
A stiffener ( angle material matching the frame ) is added at the flange midpoint or where aesthetically
pleasing for duct width or depth of 50" and greater ( as required to meet maximum 4' spacing ).

REV: 12/01/17 CAT081EA

Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®

RECTANGULAR DUCT 82
Product Guide

INDUSTRIAL INDUSTRIAL
RECTANGULAR RECTANGULAR RECTANGULAR
PARALLEL BLADE OPPOSED BLADE
CONTROL CONTROL DAMPER CONTROL DAMPER
DEVICES
PAGE: 83 PAGE: 83
INDUSTRIAL HEAVY DUTY HEAVY DUTY
RECTANGULAR RECTANGULAR RECTANGULAR
INDUSTRIAL PARALLEL BLADE OPPOSED BLADE
BACKDRAFT CONTROL DAMPER CONTROL DAMPER
DAMPER
PAGE: 84 PAGE: 85 PAGE: 85
HORIZONTAL VERTICAL
BLASTGATE BLASTGATE

PAGE: 86 PAGE: 86

REV: 12/01/17 CAT082EA

Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®

83 RECTANGULAR DUCT
Industrial Rectangular Parallel Blade
Control Damper
NOTE
All fittings with standard Fab-Tech connections "L1" 8"
include gaskets and clamps or hardware as STD
required for installation.
SPECIFICATIONS
Frame 8" standard length with 2" flanges.
Mounting holes (.562" x .750" slot)
located between 3" to 4" on center.
Blades - 10 GA stainless steel.
Axles - .50" diameter stainless steel.
Liquid tight shaft seals.
Linkage located outside the "L2"
airstream - 10 GA stainless steel
twin drive as required.
Quadrant plates - 10 GA stainless
steel.
Quadrant lever - .25" stainless steel.
Full open / full close lockouts.
PTFE frame seals.
OPTIONS
Actuator mounting kits.
Blank mounting kit ( plate & shaft adapter ) for
customer supplied actuator.
Pneumatic / electric actuator.
Gear drive with locking damper shaft. FOR "L1" OR "L2" LONGER THAN 36"
HEAVY DUTY DAMPER IS REQUIRED

Industrial Rectangular Opposed Blade


Control Damper
NOTE
All fittings with standard Fab-Tech connections "L1" 8"
include gaskets and clamps or hardware as STD
required for installation.
SPECIFICATIONS
Frame 8" standard length with 2" flanges.
Mounting holes (.562" x .750" slot)
located between 3" to 4" on center.
Blades - 10 GA stainless steel.
Axles - .50" diameter stainless steel.
Liquid tight shaft seals.
Linkage located outside the "L2"
airstream - 10 GA stainless steel
twin drive as required.
Quadrant plates - 10 GA stainless
steel.
Quadrant lever - .25" stainless steel.
Full open / full close lockouts.
PTFE frame seals.
OPTIONS
Actuator mounting kits.
Blank mounting kit ( plate & shaft adapter ) for
customer supplied actuator.
Pneumatic / electric actuator.
Gear drive with locking damper shaft.
FOR "L1" OR "L2" LONGER THAN 36"
HEAVY DUTY DAMPER IS REQUIRED
REV: 12/01/17 CAT083EA

Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®

RECTANGULAR DUCT 84
Industrial Rectangular Backdraft Damper

NOTE
"L1" 8"
All fittings with standard Fab-Tech STD
connections include gaskets and
clamps or hardware as required
for installation.
SPECIFICATIONS
10 GA stainless steel frame
8" std length with 2" flanges
center support as required.
Flange mounting holes "L2"
( .562" X .750" slot ) equal to
or less than 4" on center.
14 GA stainless steel blades.
.50" diameter stainless steel
axles.
Liquid tight shaft seals.
All linkages 10 GA stainless
steel outside airstream.
Manual adjustable COUNTERWEIGHT
counterweights.
PTFE frame seals. CENTER SUPPORT REQUIRED FOR
BLADES LONGER THAN 36" ( "L1" )

REV: 12/01/17 CAT084EA

Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®

85 RECTANGULAR DUCT
Heavy Duty Rectangular Parallel Blade
Control Damper
NOTE
All fittings with standard Fab-Tech connections 10"
"L1"
include gaskets and clamps or hardware as STD
required for installation.
SPECIFICATIONS
Frame 10" standard length with 2" flanges.
Mounting holes (.562" x .750" slot)
located between 3" to 4" on center.
Blades - 10 GA stainless steel.
Axles - 1.38" diameter stainless steel.
Liquid tight shaft seals.
Linkage located outside the "L2"
airstream - 10 GA stainless steel
twin drive as required.
Quadrant plates - 10 GA stainless
steel.
Quadrant lever - .25" stainless steel.
Full open / full close lockouts.
PTFE frame seals.
OPTIONS
Actuator mounting kits.
Blank mounting kit ( plate & shaft adapter ) for
customer supplied actuator.
Pneumatic / electric actuator.
Gear drive with locking damper shaft.
CENTER SUPPORT W/ CENTER LINKAGE
REQUIRED FOR BLADES LONGER THAN 36" ("L1").

Heavy Duty Rectangular Opposed Blade


Control Damper
NOTE
All fittings with standard Fab-Tech connections "L1" 10"
include gaskets and clamps or hardware as STD
required for installation.
SPECIFICATIONS
Frame 10" standard length with 2" flanges.
Mounting holes (.562" x .750" slot)
located between 3" to 4" on center.
Blades - 10 GA stainless steel.
Axles - 1.38" diameter stainless steel.
Liquid tight shaft seals.
Linkage located outside the "L2"
airstream - 10 GA stainless steel
twin drive as required.
Quadrant plates - 10 GA stainless
steel.
Quadrant lever - .25" stainless steel.
Full open / full close lockouts.
PTFE frame seals.
OPTIONS
Actuator mounting kits.
Blank mounting kit ( plate & shaft adapter ) for
customer supplied actuator.
Pneumatic / electric actuator.
CENTER SUPPORT W/ CENTER LINKAGE
Gear drive with locking damper shaft.
REQUIRED FOR BLADES LONGER THAN 36" ("L1").

REV: 12/01/17 CAT085EA

Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
®

RECTANGULAR DUCT 86
Horizontal Blastgate
BLADE
8"
BLADE STD
LOCKOUT
(STD) PTFE WIPER
( TYP BOTH
SIDES OF
BLADE)

"L2"
COLLAR

BODY
SPACER
"L1"
CENTER SUPPORT REQUIRED FOR BLADES LONGER THAN 36" ( "L1" )

SPECIFICATIONS
Stainless steel body, rings and blades.
Blade lockout system.
All fittings with standard Fab-Tech connections include gaskets
and clamps or hardware as required for installation.

Vertical Blastgate
BLADE 8"
STD
BLADE
LOCKOUT
(STD) PTFE WIPER
( TYP BOTH
SIDES OF
BLADE)

"L2"

COLLAR

BODY
SPACER
"L1"
CENTER SUPPORT REQUIRED FOR BLADES LONGER THAN 36" ( "L1" )
SPECIFICATIONS
Stainless steel body, rings and blades.
Blade lockout system.
All fittings with standard Fab-Tech connections include gaskets
and clamps or hardware as required for installation.
REV: 12/01/17 CAT086EA

Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com