Академический Документы
Профессиональный Документы
Культура Документы
TESTING
Report of Test
LLIA001029-001
Catalog Number: F-WP-100W/50K/BZ/HE
Wall mounted, cast aluminum housing, cast
aluminum heatsink, clear prismatic glass lens.
240 white LEDs with white plastic reflector tray over LEDs.
One Fahold FD-100H-042B LED driver.
120.0Vac, 60.00Hz, 0.7911A, 94.45W, 0.995PF, 4.5%THD(i)
Performance Summary
Total Light Output 11703 lm Power Factor 0.995
Luminaire Power 94.4 W THD(i) 4.5 %
Luminous Efficacy 124.0 lm/W Lateral Classification Type IV
Vertical Classification Short
% of Luminous Flux
BUG Rating B2-U4-G5 80°-90° Zone as
% of 0-90 lumens 10.2 %
PREPARED FOR : Topaz Lighting Corp, 925 Waverly Avenue, Holtsville, NY 11742, USA
TESTING
TESTING
90 90
1500
60 60
3000
30 30
4500
House side / L270 L90 / 270 - Black, Plane of maximum - Red, L0 / 180 - Blue (cd) Street side / L90
Percentage Outputs
Upward Downward Total
Street Side 12.3 % 74.3 % 86.6 %
House Side 0.3 % 13.1 % 13.4 %
12.6 % 87.4 % 100.0 %
Signed:
TESTING
TESTING
Lateral (V50.5) 60 30
Plane (°) (cd)
0 5266.6
15 4578.5
30 3307.2
40 3699.2
45 3425.5
50 2554.3
55 2321.9
60 2423.4
65 2385.0
70 2331.2 0
75 2100.2
80 1886.5
85 1673.0
90 1433.7
95 1180.6
100 844.5
105 684.6
110 557.2 2500
115 486.9
120 425.1
125 386.6 330
130 352.1
135 325.2
140 290.4
150 237.3 300
165 168.3 5000
180 156.3 House side Cone of maximum intensity (cd) Street side
TESTING
90 90 90
60 60
1000 2000
60
2000 4000
30 30
30
3000 6000
(L90) (cd) (L270) House side (L180) (cd) Street side (L0)
TESTING
Test Number: LLIA001029‐001
Catalog Number: F‐WP‐100W/50K/BZ/HE
Wall mounted, cast aluminum housing, cast
aluminum heatsink, clear prismatic glass lens.
240 white LEDs with white plastic reflector tray over LEDs.
One Fahold FD‐100H‐042B LED driver.
120.0Vac, 60.00Hz, 0.7911A, 94.45W, 0.995PF, 4.5%THD(i)
Coefficients Of Utilization ‐ Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20
RC 80 70 50 30 10 0
RW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
0 116 116 116 116 112 112 112 112 104 104 104 97 97 97 91 91 91 88
1 102 96 90 85 98 92 87 83 86 82 78 80 76 73 74 72 69 66
2 92 82 73 67 88 79 71 65 73 67 61 68 63 58 63 59 55 52
3 83 71 61 54 79 68 59 52 63 56 50 59 53 48 55 50 45 42
4 75 62 52 45 72 60 51 44 56 48 42 52 45 40 48 43 38 35
5 69 55 45 38 66 53 44 37 49 42 36 46 39 34 43 37 33 30
6 63 49 40 33 61 48 39 32 44 37 31 42 35 30 39 33 28 26
7 59 44 35 29 56 43 34 28 40 33 27 38 31 26 35 30 25 23
8 55 40 31 25 52 39 31 25 37 29 24 35 28 23 33 27 22 20
9 51 37 28 23 49 36 28 22 34 27 22 32 25 21 30 24 20 18
10 48 34 26 20 46 33 25 20 31 24 19 30 23 19 28 22 18 16
For absolute test reports, CUs are expressed as a percentage of total lumen output. Calculations were based on published IES procedures, and are based on the zonal cavity method. Basic
assumptions: 1) Room surfaces are lambertian reflectors. 2) Incident flux on each surface is uniformly distributed. 3) The room is spectrally neutral. When luminaires are not evenly distributed
throughout the room, or do not exhibit lateral symmetry, CU values may differ from actual performance.
Circle of Light Plot
Beam Width
(across 50% Nadir Illum)
Height(ft) Illuminance at Nadir (fc) 0‐180 90‐270
TESTING
TESTING
TESTING
TESTING
TESTING
Notes The laboratory has not participated in the selection of samples to be tested. All testing
is performed on the understanding that the significance of the report is limited to the
extent that the test sample is representative of production units.
Prorating the performance of the sample for the use of other component
combinations (such as lamp / LED / Ballast / driver), or for use in different
environmental conditions than that tested, may produce erroneous results.
Photometric intensity values are reported using the IESNA Type C coordinate system
(L, V) as defined in IESNA publication LM-75.
This report may contain data that are not covered by the NVLAP accreditation.
Quantities marked with * are not covered.
This report must not be used by the customer to claim product certification, approval
or endorsement by NVLAP, NIST, or any agency of the Federal Government.