Street Dimension = 1000 m


ILLUMINATION REQUIRED Total Area = L * W
Width of the Road = 15 m
= 1000m * 15m
Height of the Pole = 10 m = 15000m^2
Watts per lamp = 60 w Ev = CP/D^2 (cos Ө)
efficiency of the lamp = 10 lumens/watt =600/(18)^2 (10/18)
Candle Power = 600 cp Ev = 1.0288 Lux
Type of Light = LED
Type of Arrangement = Staggered Lighting
OUTPUT OF EACH LAMP = 10 Lumens (60watts/lamp)
watts

PRODUCED BY AN AUTODESK STUDENT VERSION


PRODUCED BY AN AUTODESK STUDENT VERSION

= 600 Lumens
lamp

LUX REQUIREMENT = 1.0288 Lux (15000m^2)


m^2
Z = 15432 Lumens
X

NUMBER OF LAMPS REQUIRED = ILLUMINATION LEVEL


LUMENS PER LAMP
Y
= 15432 Lumens
600 Lumens/lamp

√ = 26 Lamps * 2
√ = 52 lamps
z = 18 m
18 m
DISTANCE IN EACH LAMP = TOTAL AREA
10 m NUMBER OF LAMPS

= 1000m
26lamps
= 38.46m or 38.5m
lamps

15 m

Submitted by : JEROME V. OCASIONES

SJIT STREET LIGHTING CALCULATION EE - 10 1:00 - 6:00 PM


BUTUAN CITY
SCALE: 1:10 DATE SUBMITTED: 11-16-19 Submitted to : ENGR. ROGELIO GONZALES