INSTRUCTION MANUAL
SBT
IMO MEPC.2(VI)
Certificate No.
MED USCG JG
SBT−15 0350285 159.015/3228/0
SBT−25 0350284 159.015/3229/0
M−225
SBT−40 0350283 159.015/3230/0
SBT−65 0350282 159.015/3231/0
SEWAGE TREATMENT DEVICE SBT
Contents
Safety Instructions
WARNING CAUTION
●When the sewage treatment device is ●Do not use chemicals for cleaning of toilet.
stopped to use, empty it after cleaning the The chemicals will affect and kill the
inside of the sewage treatment tank. If microorganisms in the tank. This will
sewage has been left in the tank, the cause loss of the purification ability,
sewage will go bad, resulting in the resulting in the production of a poisonous
production of a poisonous gas. The gas or a bad smell. Use a cleaner which
inhalation of the gas may cause death. does not give damage to the
●When the inside of the sewage treatment microorganisms.
tank is inspected, check the concentration ●The aeration blower should be run
of the gas, then carry out the work after continuously. The interruption of its
safety has been verified.
continuous running will kill the
●A place where the sewage treatment
microorganisms within the sewage
device has been installed must be well
ventilated. Since a large quantity of air is treatment tank. This will cause loss of the
fed to the device, there is a possibility that purification ability, resulting in the
the surrounding area falls into a hypoxia production of a poisonous gas or a bad
state. smell. Also, there is a possibility that the
●In handling a disinfectant, follow the air discharge nozzle clogs.
disinfectant handling standards. The ●Do not put fingers or objects into the
wrong handling of the disinfectant may rotaty parts of the discharge pump and the
cause the accidents involving a human life. aeration blower. There is a possibility of
●When the discharge pump, the aeration injury.
blower or the level switch is examined, turn ●Sewage may leak out from the shaft
off the control panel breaker. Also, turn seal part of discharge pump due to the
the control switch off. In addition, tag the termination of its service life. The sewage
control panel as "Energizing Is Prohibited" , that leaked out will go bad and then
so that the switch is not turned on by produce a poisonous gas, resulting in the
mistake. accidents involving a human life, or in
●When the discharge pump, the sewage corrosion or failure of implements. Clean
pipe and valve, are overhauled, carry out the area under ventilation, and stop the
the work under ventilation, since sewage leak by replacing parts with new ones.
may contain a poisonous gas. ●The inner surface of the sewage trearment
●In climbing on the sewage treatment tank,
tank has been coated with tar-epoxy. Do
wear a helmet and the gloves and shoes
not bring fire close to the tank, or the
with a slide stop function. Also, when the
work is carried out at a high place, wear a coating will be damaged, thereby causing
safety belt. A fall from the place may sewage to leak out from damaged portions
occur, result in the accidents involving a of the tank.
human life. ●Close the manhole of the sewage
●The work for maintaining and checking the treatment tank so securely that sewage or
inside of the control panel should be odor will not leak out.
carried out by electrician with expert ●Check the air vent pipe for the clogging
knowledge. The accidental contact with because of sewage or dewing. If the pipe
the high-voltage current may cause the clogs in this way, the toilet seal water trap
death by an electric shock. will be broken by the back pressure of the
aeration blower, thereby causing the toilet
water to splash and at the same time
resulting in the emission of a poisonous
bad smell. Also, the splashes dirty your
clothes and the surrounding area.
●The paper to be used in the toilet should
be soluble in water. Stuffs which are
insoluble in water, such as sanitary
product, should not be thrown into the
toilet but be thrown into a waste-basket
placed in the toilet. These stuffs may
cause the clogging or failure of the pump.
1
SEWAGE TREATMENT DEVICE SBT
2
SEWAGE TREATMENT DEVICE SBT
3. Design
3.1 These devices have been designed to
comply with the US Regulation 33CFR Part
159 and may be installed in an
uninspected vessel,(as defined by the
USCG).
3.3 Specifications
Table 1
Item Model SBT-15 SBT-25 SBT-40 SBT-65
Number of persons persons/day 15 25 40 65
Average of sewage processed L/day 900 1500 2400 3900
Processed amount of sewage L/h×Times/day 94×3 156×3 250×3 406×3
BOD amount g/day 202.5 337.5 540 877.5
3
Air flow m /min 0.22 0.37 0.60 0.98
Blower Pressure
0.02
MPa
Motor Power Input kW 0.4 0.4 0.75 0.75
Capacity m3 4
/h
Discharge
Head 20
m
Pump
Motor Power Input 1.5
kW
3
SEWAGE TREATMENT DEVICE SBT
4
SEWAGE TREATMENT DEVICE SBT
5
SEWAGE TREATMENT DEVICE SBT
c. Do not use paper containing vinyl b. Turn off "AERATION BLOWER" switch.
components.
c. Turn off "DISCHARGE PUMP" switch.
d. Be sure to flush after each use of toilet
d. Turn off "POWER SOURCE" by turning off
bowl.
the main circuit breakers.
e. Chemicals for cleaning toilet bowl
e. To reactivate the device, reverse items b -
(hydrochloric acid, bowl cleaners and
d above and allow sewage to flow into the
deodorizers etc.)should be used sparingly.
device. Close direct overboard discharge
When used, they should be directly
valves.
discharged overboard.
(Only in unrestricted waters). Additionaly
after chemicals are used, rinse with water.
If chemicals enter into the treatment
device, operation may be hindered.
6
SEWAGE TREATMENT DEVICE SBT
Table 5 SBT-40 40 14 2
SBT-65 65 23 2
manufacturer Brand Name Chemical Designation
1.5 tablets/month×person
Nippon Soda Calcium Hypochlorite
Nisso Hicron
Co., Ltd. Ca(C O)2・3H2O
7
SEWAGE TREATMENT DEVICE SBT
8.3 Blower Maintenance e. After adjusting the axes, check the tension
of the V-belt once more in the manner as
8.3.1 Confirmation of the quantity of oil of described in c or d.
aeration blowers and cleaning of air filter.
f. Then, tighten the motor-fixing bolts.
a. Check the quantity of oil in the oil level
indicator of aeration blowers(Sight
glass).
Fig.3
If the level is low, replenish using the
recommended lubricating oils(Turbine Oil
ISO VG68).
Once every six months(especially when
the oil contains dirt and looks black)drain
the oil from the drain opening of the oil
bath and refill with new oil to proper level.
8
SEWAGE TREATMENT DEVICE SBT
8.4 Bio-Filter Tank Screen f. Shut treatment water outlet valve ③ and
open stop valve ④ and drain valve for bio-
Cleaning of the bio-filter tank screen filter tank ⑤ .
Open the manhole ⑮ and remove foreign
g. Turn the discharge pump switch to
matter from the screen ② . To prevent foreign
"MANUAL" and press black clored "START"
matter from entering the system, place an
switch. When the sludge has been
instruction placard near each toilet bowl.
removed from the tank, turn off discharge
8.5 Bio-Filter Tank pump.
If Discharge pump is operated in dry
Back flush and sludge removal should condition, the pump will be damaged so
be done monthly. Sludge removal should be that please pay ateention for this matter.
pumped overboard(only into unrestricted
h. Open cleaning water inlet valve (Not
waters)or ashore into a sewage system.
supplied) and introduce cleaning water
a. Turn the discharge pump switch to into the treatment device.
"MANUAL" and press red colored "STOP" Use the same kind of water-sea water,
switch. fresh water - or brackish water - as flush
water used in this system before removal
b. Turn the blower switch to "STOP".
of sludge.
c. Open air scour valve ⑥ (left side)and shut
i. When "HIGH WATER LEVEL" indicator lamp
air lift valve ⑦ .
at the control panel lights. Close the
d. Turn the blower switch to "RUN". Continue cleaning water inlet valve and the stop
this state about 30 minutes. valve ④ and drain valve for bio-filter tank ⑤ .
Fixed sludge on packing media ⑰ will be
j. Open treatment water outlet valve ③ , and
removed.
turn discharge pump switch to "AUTO".
e. Shut air scour valve ⑥ and open air lift valve
k. Turn the blower switch to "RUN".
⑦.
Uniform Good
Recirculation
Stopped Aeration blower has stopped
Light brown Good
Transparency
Tone of color
Yellow Sewage load is too heavy (The number of
persons using exceeds device rating)
Little Good
9
SEWAGE TREATMENT DEVICE SBT
Table 10
10
SEWAGE TREATMENT DEVICE SBT
11.1 General Scope of Level Probe If the automatic starting and stopping
of pump and high level alarm is not working
This Sewage Treatment Device equips normally, we suppose that the cause of above
a. capacitance type level probe in the is by the problem of Level Prove. In this case,
sterilization compartment. This level probe please carry out the following investigation.
which is series of sensors detects the level
of water in the sterilization compartment at a. Open the cap of level prove, and
each level, gives the signal for starting and disconnect the wiring of terminal“P”and
stopping the discharge pump, and provides “E”. All LSU operation lamps of“L” ,“H”,
warning for abnormal high water level to the and“HH”in control panel are put off at
level switch unit. Since the sterilization the disconnection of wiring. If above lamps
compartment is isolated, visual check is not are not put off, the LSU is defected so that
possible from the outside. Therefore, the there is need to replace it.
water level can be only checked by the b. If there is no defected for the LSU, there is
lighting of level indicators on the level switch possibility that the level prove is out of
unit inside of the control panel as shown order. It is possible to pull out the censer
below. part by take off two screws that is fitted
Timers are incorporated in each sensors beside of level prove terminal box. Please
for the pump start level and high water level. check whether there is any breaking of wire
The former has the function to automatically or otheres defected part on each censer
stop the pump if the sensor in pump stop part or not.
level fails: it will be adjusted depends on
,
sterilization compartment s size(MAX 20 c. Wiring the sensor line under the condition
seconds). The later is designed to avoid any that the sensor part is pulled out. Each
undesirable activation due to water splash: sensor line is corresponded to the
the timer provides warning signal 15 seconds operating light that is installed on LSU in
after the sensor was sunken into the water. the control panel. (in order L,H, and HH
from bottom side)
11.2 Working Principle If you clasp the sensor L, the operating
light of L is output. If you grip the sensor
This level probe detects the difference H with grasp the sensor L, the operating
of boundary surface between the water and light of L and H are output. (If you only
the air as variation of capacitance and clasp the sensor H, the operating light is
transmits the signal to the level switch unit. not output.)
The value of dielectric constant significantly If you grip the sensor HH more than 15
changes between the water and the air. This seconds, the operating light of HH is
variation is turned into the strong / weak output. (If you only calsp the sensor HH,
circuit transmit voltage and is applied as on the operating light is output.)
/ off signal of the relay circuit in the level
switch unit. d. If you clasp the sensor, and the operating
lights are not output normally, the Level
11.3 Confirm Operation Prove is out of order. Therefore, there is
need to replace all of them.
Pump Stop Water Level ∼ Lamp "L" Lights
Pump Start Water Level ∼ Lamps "L" "H" Light
e. If there is no abnormal part on level prove
IGH Water Level ∼ All Lamps Light
by above inspections, there is possibility
Adjustment Trimmer Of that some material is stuck on the level
Timer For Pump Stop (max.20s) prove pipe so that please remove them by
Fig.6 Level Switch Unit (inside Of The pull out the level prove.
Control Panel)
f. Voltage between terminal P and E
(Reference Value)
Level Controller LED unlighted : DC15V
L H HH "L" Lighted : 13.3V
"L" "H" Lighted : 11.7V
Indicator
"L" "H" "HH" Lighted : 8.4V
Lamp(red)
10
20
11
SEWAGE TREATMENT DEVICE SBT
No. Name
A Bio-filter tank
B Sterilization
compartment
C Sewage inlet
D Sewage inlet
E Air outlet
F Emergency overflow
G Cleaning water Inlet
H Discharge
1 Tank
2 Screen
12
SEWAGE TREATMENT DEVICE SBT
1 Cover 1
2 Body 1
3 Gland 1
4 Electrode 1
13
URL http://www.taiko-kk.com
Head Office & 209-1 Shimotabuse, Tabuse-cho, Kumage-gun, Yamaguchi pref. 742-1598 Japan
Factory TEL:81-820-52-3114 FAX:81-820-53-1001 E-mail:business@taiko-kk.com VACUUM PUMP
Tokyo Branch 4th floor, Suidobashi MS Building, 3-4-9 Misaki-cho, Chiyoda-ku, Tokyo 101-0061 Japan ROTARY BLOWER OILY WATER
SEPARATOR
TEL:81-3-3221-8551 FAX:81-3-3221-8555 E-mail:tokyo-br@taiko-kk.com
Osaka Branch 8th floor, KC Building, 3-4-7 Kawara-machi, Chuo-ku, Osaka 541-0048 Japan
SCREW PUMP
TEL:81-6-6231-6241 FAX:81-6-6222-3295 E-mail:osaka-br@taiko-kk.com SEWAGE TREATMENT
DEVICE
Beijing Office Room 7-4H, Julong Garden, No.68 Xinzhong Street, Dongcheng District, Beijing 100027 China
TEL:86-106551-9673 FAX:86-106552-7742 E-mail:taiko-beijing@taiko-kk.com
2004/12 MUTSUMI