Академический Документы
Профессиональный Документы
Культура Документы
Features
Temperature Operating Range
• One coat system, no primer needed, no intercoat bonding
problems Scotchkote 226N Coating performs on pipelines operating
• Superior cathodic disbondment resistance without between -75°F and 230°F (-60°–110°C). Laboratory tests
pretreatment indicate that thicker coatings may improve the service
• Meets CAN/CSA-Z 245.20-M92 and British Gas capability for temperatures between 170°F and 230°F
PS/CW6 without pretreatment (77°–110°C). However, it is difficult to accurately predict
• Uniform coating thickness field performance from laboratory data due to the wide
• Easy visual inspection of surfaces variation in actual field conditions. Coating thickness, soil
• Highly resistant to moisture penetration, bacteria, fungus, type, moisture content and temperature unique to the
soil acids, alkalis, salt, hydrocarbons and other chemicals pipeline location affect the coating performance and the
associated with pipeline systems upper temperature operating limit.
• Greater resistance to soil stress and backfill compaction Handling and Safety Precautions
• Bendability exceeds ANSI B31.4 or B31.8 codes
• Protects over a wide range of temperatures Read all Health Hazard, Precautionary, and First Aid
• Stores in all climates statement found in the Material Safety Data Sheet, and/or
• Pipe can be stacked without padding product label of chemicals prior to handling or use.
• May be used with 3M™ Scotchkote™ 6251
Properties
General Application
Property Value
• Remove oil, grease and loosely adhering deposits
• Abrasive blast clean the surface to near-white in Color Green
accordance with SSPC-SP10 or NACE No. 2 Specific Gravity-Powder 1.44
• Preheat cleaned pipe to approximately 450°F (232°C). (Air Pycnometer)
• Deposit Scotchkote 226N coating by electrostatic spray Coverage 134 ft2/lb/mil (0.695m2/kg/mm)
to a minimum thickness of 12 mils (305 microns)
• Allow to cure according to the cure specifications below Shelf Life at 80°F (27°C) 12 months
• Electrically inspect for holidays after coating has cooled Gel Time 450°F (232°C) 400°F (204°C)
to 200°F (93°C) or lower 226N Fast 3-6 seconds 7-12 seconds
• Repair all possible holidays 226N Slow (8 G) 6-9 seconds 14-18 seconds
226N Slow (11 G) 10-13 seconds 19-24 seconds
Cure Specifications Minimum Explosive 0.10 oz/ft2 (102 g/m3)
Cure by residual heat. Post-bake is normally not required; Concentration
however, extra-light wall pipe may require additional curing
time.
Cure time is based on the temperature of the steel from
application point of the powder to the forced-air or water
cool-down. After the coating has cured, cool pipe with air
or water spray. Pipe cooling rates are based on .500"
(12.7mm) wall thickness and are included in cure time
figures. Follow the cure guide instructions to achieve
maximum performance.
3M Scotchkote 226N Test Data-Coatings
™
™
Important Notice
All statements, technical information, and recommendations related all warranties, expressed or implied, including but not limited to the
to Seller’s products are based on information believed to be reliable, implied warranties of merchantability and fitness for a particular
but the accuracy or completeness thereof is not guaranteed. Before purpose which warranties are hereby expressly disclaimed.
utilizing the product, the user should determine the suitability of the
product for its intended use. The user assumes all risks and liability SELLER SHALL NOT BE LIABLE TO THE USER OR ANY OTHER
whatsoever in connection with such use. PERSON UNDER ANY LEGAL THEORY, INCLUDING BUT NOT
LIMITED TO NEGLIGENCE OR STRICT LIABILITY, FOR ANY
Any statements or recommendations of the Seller which are not INJURY OR FOR ANY DIRECT, INDIRECT, INCIDENTAL OR
contained in the Seller’s current publications shall have no force or CONSEQUENTIAL DAMAGES SUSTAINED OR INCURRED BY
effect unless contained in an agreement signed by an authorized REASON OF THE USE OF ANY OF THE SELLER’S PRODUCTS.
officer of Seller. The statements contained herein are made in lieu of