Вы находитесь на странице: 1из 18

CLIENT Indus Towers Limited, Mumbai CONSULTANT:

PROJECT: 18 M SQUARE TOWER WITH ELEVATED FRP CIRCULAR TANK.


TITLE: DESIGN OF 15.0+3.0 M SQUARE TOWER
DOC NO. : DGN-REP-18M-SRTT-3MCAM

CONTENTS:

1) Specifications
2) Load Calculations
3) Staad Pro Input and Design Report
4) Design of Connections
5) Design of Base Plate and Stiffeners
6) Design of Anchor Bolts
7) Check for Deflection
CLIENT Indus Towers Limited, Mumbai CONSULTANT:
PROJECT: 18 M SQUARE TOWER WITH ELEVATED FRP CIRCULAR TANK.
TITLE: DESIGN OF 15.0+3.0 M SQUARE TOWER
DOC NO. : DGN-REP-18M-SRTT-3MCAM

1) SPECIFICATIONS

Dimensions
Height of Tower = 15 m
Ht. Above GL = 0m
Total height = 15 m
Dia of circular camouflage tank = 0m
Height of camouflage tank = 0m
Base width of each side of tower = 1.2 m
Ht. of each frame (grid) = 1.8 m

Reference Indian Standard


Wind load IS-875 (part-3):2015
Steel design Code IS 800:2007

Member Specifications

Pipe Section NB80M


Outer dia = 88.9 mm
Thickness = 4 mm

Pipe Section NB100M


Outer dia = 114.3 mm
Thickness = 4.5 mm

Pipe Section NB32M


Outer dia = 42.4 mm
Thickness = 3.2 mm

Angle section confirming IS 808:1989


ISA 50 x 50 x 6 DIAGONAL MEMBER
ISA 50 x 50 x 6 HORIZONTAL MEMBER
ISA 50 x 50 x 6 BOTTOM DIAGONAL

Rectangular Hollow Section RHS50x25x3.2 Confirming IS 4923


Width L X Length B = 50x25 mm
Thickness of tube = 3.2 mm

Square Hollow Section SHS60x60x4 Confirming IS 4923


Width of tube B = 60 mm
Thickness of tube = 4 mm
CLIENT Indus Towers Limited, Mumbai CONSULTANT:
PROJECT: 18 M SQUARE TOWER WITH ELEVATED FRP CIRCULAR TANK.
TITLE: DESIGN OF 15.0+3.0 M SQUARE TOWER
DOC NO. : DGN-REP-18M-SRTT-3MCAM

Types and Loading of Antenna


Weight of GSM -1 = 30 Kg
Weight of CIRCULAR - 1 = 30 Kg

Dimensions of Antenna
GSM - 1 : 2600 x 270 x 150
CIRCULAR - 1 : 0.6 m diameter
Note: All Dimensions in mm unless specified.

Nos. of Antenna
GSM - 1 : 6 Nos.
CIRCULAR - 1 : 6 Nos.

Type of camouflage
Diameter of tank = 0m
Height of tank = 0m

2) LOAD CALCULATIONS

Dead Load:
The load under this category includes self weight of structure and antennas.
A 10% increment of self weight of structure has been considered for ladder and wires loading.

Thk. Of cheqd. Plate = 6 mm


Weight of chqd plate thk. = 54.17 Kg/m2

Due to antenna 1 and circular antenna = 60 Kg


Load on each Node (Applied on 2 nodes) = 0.300 kN

Load of frp sheet = 5.000 kg/m2


area of one panel = 2.160 m2
Load of frp sheet = 10.800 kg
Load on each intermediate node = 0.108 kN
Load on each end node = 0.054 kN

Load of frp sheet = 5.000 kg/sqm


area of one panel on tank = 0.000 sqm
Load of frp sheet = 0.000 kg
Load of frp sheet in kN = 0.000 kN
No. of nodes = 12
Load on each end node = 0.000 kN
CLIENT Indus Towers Limited, Mumbai CONSULTANT:
PROJECT: 18 M SQUARE TOWER WITH ELEVATED FRP CIRCULAR TANK.
TITLE: DESIGN OF 15.0+3.0 M SQUARE TOWER
DOC NO. : DGN-REP-18M-SRTT-3MCAM

Imposed Load:

Live Load (wt. of a man + equipment) = 100 Kg


Load on each node = 1.000 kN

Wind Load:
Basic wind speed, Vb = 44 m/s
Overall height = 15 m
Class of Structure = 3
Mean probable life = 25 Yrs
Terrain category = 3
k1 = 0.91 (Table-1, IS:875 Part-3)
k2 = 0.97 (Table-2, IS:875 Part-3)
k3 = 1.00 (Clause 6.3.3, IS:875 Part-3)
k4 = 1.00 (Clause 6.3.4, IS:875 Part-3)

k2
HT.(m)
1 2 3 4
10 1.05 1 0.91 0.8
15 1.09 1.05 0.97 0.8
20 1.12 1.07 1.01 0.8
30 1.15 1.12 1.06 0.97
40 1.175 1.145 1.09 1.035
50 1.2 1.17 1.12 1.1
100 1.26 1.24 1.2 1.2

Vd = Vb x k1 x k2 x k3 x k = 34.95 m/s
pz = 0.6 x Vz^2 = 733.11 N/m2

For wind in +X/+Z direction:

Wind load on tower


Panel Type-1 (114 dia Pipe)
Height of each grid = 1.8 m
Gross area, Ag = 2.366 m2
Area of round elements, Ar = 0.411 m2
Length of Flat horizontal member = 1.200 m
Length of Flat diagonal members = 2.160 m
Area of flat elements, Af = 0.276 m2
Solidity ratio, φ = 0.29
D*Vz = 4.00 <6 m2/s
CLIENT Indus Towers Limited, Mumbai CONSULTANT:
PROJECT: 18 M SQUARE TOWER WITH ELEVATED FRP CIRCULAR TANK.
TITLE: DESIGN OF 15.0+3.0 M SQUARE TOWER
DOC NO. : DGN-REP-18M-SRTT-3MCAM

Cf, flat = 2.85 (From Table-33)


Cf, round = 1.72 (From Table-34/35)

Effective Cf = 2.17

UDL on Flat Members :


Flat horizontal members = 0.080 kN/m
Flat diagonal members = 0.080 kN/m

UDL on Round Members = 0.182 kN/m

Panel Type-2 (88 dia Pipe)


Height of each grid = 1.8 m
Gross area, Ag = 2.320 m2
Area of round elements, Ar = 0.320 m2
Length of Flat horizontal member = 1.200 m
Length of Flat diagonal member = 2.160 m
Area of flat elements, Af = 0.276 m2
Solidity ratio, φ = 0.26
D*Vz = 4.00 <6 m2/s

Cf, flat = 3.02 (From Table-30)


Cf, round = 1.79 (From Table-31)

Effective Cf = 2.36

UDL on Flat Members :


Flat horizontal members = 0.086 kN/m
Flat diagonal members = 0.086 kN/m

UDL on Round Members = 0.198 kN/m

Wind load on camouflage tank


ht of tank = 0m
diameter = 0m
ht to width ratio = #DIV/0!
Vd x b = 0.00 m2/s
Cf 0.80 (from table 25)
total load = 0.00 kN

No. of nodes for wind along x = 8 nos


Load per node on x side = 0 kN
CLIENT Indus Towers Limited, Mumbai CONSULTANT:
PROJECT: 18 M SQUARE TOWER WITH ELEVATED FRP CIRCULAR TANK.
TITLE: DESIGN OF 15.0+3.0 M SQUARE TOWER
DOC NO. : DGN-REP-18M-SRTT-3MCAM

No. of nodes for wind along z = 8 nos


Load per node on x side = 0 kN

For diagonal wind:


The diagonal wind can be resolved into X,Z directions having component of 0.707 each.
As per codal provisions the load has to be factored by 1.2 times.

LOAD COMBINATION CONSIDERED

LOAD COMB 101 DL+LL


1 1.0 2 1.0
LOAD COMB 102 D.L.+L.L.+WLX
1 1.0 2 1.0 3 1.0
LOAD COMB 103 D.L.+L.L.-WLX
1 1.0 2 1.0 3 -1.0
LOAD COMB 104 D.L.+L.L.+WLZ
1 1.0 2 1.0 4 1.0
LOAD COMB 105 D.L.+L.L.-WLZ
1 1.0 2 1.0 4 -1.0
LOAD COMB 106 D.L.+L.L.+0.707WLX+0.707WLZ
1 1.0 2 1.0 3 0.707 4 0.707
LOAD COMB 107 D.L.+L.L.-0.707WLX-0.707WLZ
1 1.0 2 1.0 3 -0.707 4 -0.707
LOAD COMB 108 D.L.+WLX
1 1.0 3 1.0
LOAD COMB 109 D.L.-WLX
1 1.0 3 -1.0
LOAD COMB 110 D.L.+WLZ
1 1.0 4 1.0
LOAD COMB 111 D.L.-WLX
1 1.0 4 -1.0
LOAD COMB 112 D.L.+0.707WLX+0.707WLZ
1 1.0 3 0.707 4 0.707
LOAD COMB 113 D.L.-0.707WLX-0.707WLZ
1 1.0 3 0.707 4 0.707
LOAD COMB 201 1.5(D.L.+L.L.)
1 1.5 2 1.5
LOAD COMB 202 1.5(D.L.+WLX)
ULTANT:
CLIENT ATC TELECOM INFRASTRUCTURE PVT. LTD. CONSULTANT:
SITE: HOTEL RAJ JOG
TITLE: 12M. ROOF TOP DELTA
DATE: 19/Jul/18

CONTENTS:

1) Specifications
2) Load Calculations
3) Staad Pro Input and Design Report
4) photos
CLIENT ATC TELECOM INFRASTRUCTURE PVT. LTD. CONSULTANT:
SITE: HOTEL RAJ JOG
TITLE: 12M. ROOF TOP DELTA
DATE: 19/Jul/18

1) SPECIFICATIONS

Dimensions
Height of Tower = 18.000 m
Width of tower at bottom = 3.200 m
Width of tower at 6.5m level = 1.600 m
Outer diameter of pipe = 88.900 mm

Reference Indian Standard


Wind load IS-875 (part-3):2015
Steel design Code IS 800:2007

Member Specifications

Pipe Section NB80M


Outer dia = 88.900 mm
Thickness = 4.000 mm

Angle section confirming IS 808:1989


ISA 65.000 x 65.000 x 6.000 DIAGONAL MEMBER
ISA 50.000 x 50.000 x 6.000 HORIZONTAL MEMBER

GSM 1 1300.000 X 300.000 X 150.000 mm 3Nos


GSM 2 1200.000 X 350.000 X 150.000 mm 3Nos
GSM 3 1400.000 X 350.000 X 150.000 mm 3Nos
GSM 4 2500.000 X 350.000 X 150.000 mm 3Nos
VODA ANTENNA 2700.000 X 305.000 X 150.000 mm 3Nos
M/W 1 600.000 mm Dia 2Nos
M/W 2 300.000 mm Dia 3Nos

Weight of GSM 1 = 25.000 Kg


Weight of GSM 2 = 25.000 Kg
Weight of GSM 3 = 25.000 Kg
Weight of GSM 4 = 44.000 Kg
Weight of VODA ANTENNA = 44.000 Kg
Weight of M/W 1 = 25.000 Kg
Weight of M/W 2 = 10.000 Kg
CLIENT ATC TELECOM INFRASTRUCTURE PVT. LTD. CONSULTANT:
SITE: HOTEL RAJ JOG
TITLE: 12M. ROOF TOP DELTA
DATE: 19/Jul/18

2) LOAD CALCULATIONS

Dead Load:
The load under this category includes self weight of structure and antennas.
A 10% increment of self weight of structure has been considered for ladder and wires loading.

Due to GSM 1 = 30.000 Kg = 0.300 Kn


Due to GSM 2 = 30.000 Kg = 0.300 Kn
Due to GSM 3 = 30.000 Kg = 0.300 Kn
Due to GSM 4 = 44.000 Kg = 0.440 Kn
Due to VODA ANTENNA = 44.000 Kg = 0.440 Kn
Due to M/W 1 = 25.000 Kg = 0.250 Kn
Due to M/W 2 = 10.000 Kg = 0.100 Kn

Imposed Load:

Live Load (Weight of man + equipment) = 100.000 Kg


Load on each node = 1.000 kN

Wind Load:
Basic wind speed, Vb = 44.000 m/s
Overall height = 33.000 m
Mean probable life = 25.000 Yrs
Terrain category = 3.000
k1 = 0.910 (Table-1, IS:875 Part-3)
k2 = 1.069 (Table-2, IS:875 Part-3)
k3 = 1.000 (Clause 6.3.3, IS:875 Part-3)
k4 = 1.000 (Clause 6.3.4, IS:875 Part-3)

k2
HT.(m)
1.000 2.000 3.000 4.000
10.000 1.050 1.000 0.910 0.800
15.000 1.090 1.050 0.970 0.800
20.000 1.120 1.070 1.010 0.800
30.000 1.150 1.120 1.060 0.970
40.000 1.175 1.145 1.090 1.035
50.000 1.200 1.170 1.120 1.100
100.000 1.260 1.240 1.200 1.200
CLIENT ATC TELECOM INFRASTRUCTURE PVT. LTD. CONSULTANT:
SITE: HOTEL RAJ JOG
TITLE: 12M. ROOF TOP DELTA
DATE: 19/Jul/18
Vd = Vb x k1 x k2 x k3 = 42.803 m/s
pz = 0.6 x Vz^2 = 1099.250 N/m2
Considering wind directionality factor, Kd = 0.900
Design wind pressure = 989.325 N/m2
= 0.989 KN/m2

For wind in +X/+Z direction:


structure is square so wind load on either +X/+Z remains the same

Wind load on tower


A)wind load upto 6.50m height
Height of each grid = 1.500 m
Gross area, Ag = 4.800 m2
Area of round elements, Ar = 0.400 m2
Length of Flat horizontal member = 3.200 m
Length of Flat diagonal member = 2.190 m
Area of flat elements, Af = 0.445 m2
Solidity ratio, φ = 0.176
D*Vz = 3.805 <6 m2/s

Cf, flat = 2.796 (From Table-33)


Cf, round = 1.624 (From Table-34)

Effective Cf = 2.241

UDL on Flat Members :


Flat horizontal members = 0.111 kN/m
Flat diagonal members = 0.144 kN/m

UDL on Round Members = 0.197 kN/m

b)wind load upto 6.50m height


Height of each grid = 1.500 m
Gross area, Ag = 2.400 m2
Area of round elements, Ar = 0.267 m2
Length of Flat horizontal member = 1.600 m
Length of Flat diagonal member = 2.190 m
Area of flat elements, Af = 0.222 m2
Solidity ratio, φ = 0.204
D*Vz = 0.123 <6 m2/s

Cf, flat = 2.684 (From Table-33)


Cf, round = 1.596 (From Table-34)
CLIENT ATC TELECOM INFRASTRUCTURE PVT. LTD. CONSULTANT:
SITE: HOTEL RAJ JOG
TITLE: 12M. ROOF TOP DELTA
DATE: 19/Jul/18

Effective Cf = 2.091

UDL on Flat Members :


Flat horizontal members = 0.103 kN/m
Flat diagonal members = 0.134 kN/m

UDL on Round Members = 0.184 kN/m

WIND LOAD ON ANTENNA


1) GSM-1, 1300 X 150 X 150 mm = 1.300 X 0.150
Cf = 1.330 from fig. 4
F = Cf x Pz x A
F = 0.257 KN

2) GSM-2 1390 X 510 X150 mm = 1.390 X 0.510


Cf = 1.260 from fig. 4
F = Cf x Pz x A
F = 0.884 KN

3) GSM-3, 2700 X 260 X150 mm = 2.700 x 0.260


Cf = 1.380 from fig. 4
F = Cf x Pz x A
F = 0.958 KN

4) Bi-Sector, 2400 X 350 X150 mm = 2.400 X 0.350


Cf = 1.340 from fig. 4
F = Cf x Pz x A
F = 1.114 KN

5)Pentaband Antenna,1650X390X150 mm = 1.650 x 0.390


Cf = 1.300 from Table 27
F = Cf x Pz x A
F = 0.828 KN

6) M/W1, 600mm = 0.600 m


Cf = 1.200 from Table 27
F = Cf x Pz x A
F = 0.335 KN

7) M/W2, 300mm = 0.300 m


CLIENT ATC TELECOM INFRASTRUCTURE PVT. LTD. CONSULTANT:
SITE: HOTEL RAJ JOG
TITLE: 12M. ROOF TOP DELTA
DATE: 19/Jul/18
Cf = 1.200 from Table 27
F = Cf x Pz x A
F = 0.084 KN

For diagonal wind:


The diagonal wind can be resolved into X,Z directions having component of 0.707 each.
As per codal provisions the load has to be factored by 1.2 times.
CLIENT Relience Jio Infocomm Ltd. CONSULTANT:
PROJECT: 24m Guyed Mast
TITLE: Preliminary Design Report For 24m Guyed Mast
Date: 10/1/2018

CONTENTS:

1) Specifications
2) Load Calculations
3) Staad Pro Input and Output
CLIENT Relience Jio Infocomm Ltd. CONSULTANT:
PROJECT: 24m Guyed Mast
TITLE: Preliminary Design Report For 24m Guyed Mast
Date: 10/1/2018

1) SPECIFICATIONS

Dimensions
Height of Guyed Mast = 24.000 m
Width of Guyd Mast = 300.000 mm
Outer diameter of pipe = 33.700 mm

Reference Indian Standard


Wind load IS-875 (part-3):2015
Steel design Code IS 800:2007

Member Specifications

Pipe Section NB25M


Outer dia = 33.700 mm
Thickness = 3.200 mm
Diagonal Member = 12.000 mm dia. rod
Horizontal Member = 12.000 mm dia. rod
Guyed Wire = 10.000 mm dia. Wire

guyed Wire are at 11.50m , 16.50m and 21.50m from bottom respectievely

Antenna Specifications
U.B.R 0.400 X 0.600 m 2Nos.
M/W 1 0.600 m Dia 1No.

Weight of U.B.R = 10.000 Kg


Weight of M/W 1 = 25.000 Kg

Antenna mounting height


1) U.B.R 0.40 X 0.60 m at 0.30m from top
2) M/W 600mm dia at top level
CLIENT Relience Jio Infocomm Ltd. CONSULTANT:
PROJECT: 24m Guyed Mast
TITLE: Preliminary Design Report For 24m Guyed Mast
Date: 10/1/2018

2) LOAD CALCULATIONS

Dead Load:
The load under this category includes self weight of structure and antennas.
A 10% increment of self weight of structure has been considered for connections and wires loading.

Due to U.B.R = 10.000 Kg = 0.100 Kn


Due to M/W 1 = 25.000 Kg = 0.250 Kn

Imposed Load:

Live Load (Weight of man + equipment) = 100.000 Kg


Load on each node = 1.000 KN

Wind Load:
Basic wind speed, Vb = 50.000 m/s
Overall height = 24.000 m
Mean probable life = 25.000 Yrs
Terrain category = 2.000
Probability factor = K1
Terrain,Height factor = K2
Topography factor = K3
Importance Factor = K4

Desin wind speed (Vz) = Vb x k1 x k2 x k3 x k4


Considering wind directionality factor, Kd
Design wind pressure (Pzd) = 0.6 x Kd x Pz^2
Design Wind Speed and Design Wind Pressure at different height is shown in table
below:

Design Design
baisc wind risk factor Ht. Factor Topograph Design wind wind
wind Direction pressure
height (m) speed (Vb) y factor pressure
(K1) (K2) speed (Vz) (Pz) factor Kd (Pzd)
(m/s) (K3) (m/s) (KN/m2) (KN/m2)

9.000 50.000 0.900 1.000 1.000 45.000 1.215 0.900 1.094


12.000 50.000 0.900 1.020 1.000 45.900 1.264 0.900 1.138
15.000 50.000 0.900 1.050 1.000 47.250 1.340 0.900 1.206
18.000 50.000 0.900 1.062 1.000 47.790 1.370 0.900 1.233
21.000 50.000 0.900 1.075 1.000 48.375 1.404 0.900 1.264
CLIENT Relience Jio Infocomm Ltd. CONSULTANT:
PROJECT: 24m Guyed Mast
TITLE: Preliminary Design Report For 24m Guyed Mast
Date: 10/1/2018
24.000 50.000 0.900 1.090 1.000 49.050 1.444 0.900 1.299

Wind load on tower


Height of pannel = 3.000 m
width of tower = 0.300 m
diagonal length = 0.424 m

dia. Of vertical = 33.700 mm = 0.034 m


dia. Of horizontal = 12.000 mm = 0.012 m
dia. Of diagonal = 12.000 mm = 0.012 m
gross area = 0.900 m2
area of vertical = 0.202 m2
area of horizontal = 0.032 m2
area of diagonal = 0.046 m2
net area = 0.280 m2

solidity ratio = 0.31


D*Vz = 1.653 <6 m2/s
cf of round = 1.500 (From Table-35)

Wind load on tower components at different height as per table below:

Udl load on Tower members


height wind pressure fore coefficient (Cf) vertical horizontal diagonal
(Ht.) (Kn/m2)
(KN/m) (KN/m) (KN/m)
9.000 1.094 1.500 0.0553 0.0197 0.0197
12.000 1.138 1.500 0.0575 0.0205 0.0205
15.000 1.206 1.500 0.0609 0.0217 0.0217
18.000 1.233 1.500 0.0623 0.0222 0.0222
21.000 1.264 1.500 0.0639 0.0227 0.0227
24.000 1.299 1.500 0.0657 0.0234 0.0234

Wind loading on guy wire = Pz x Cf x Dia.


= 0.016 KN/m

Antenna Loading:
1)U.B.R 0.4 X 0.6m = 0.400 x 0.600
Cf = 1.200 from fig. 4
CLIENT Relience Jio Infocomm Ltd. CONSULTANT:
PROJECT: 24m Guyed Mast
TITLE: Preliminary Design Report For 24m Guyed Mast
Date: 10/1/2018
= Cf x Pz x A
= 0.374 KN

6) M/W1, 600mm = 0.600 m


Cf = 1.200 from Table 27
= Cf x Pz x A
= 0.441 KN

Вам также может понравиться