Examination Environment Preparation

Examination Environment Preparation V1.5

Document Scope and Structure


Note: Strongly recommend that please arrange the IP instructor or IP engineer to prepare

the environment.

This document covers the four modules:

 Module I. Related Files Preparation

 Module II. eNSP Installation

 Module III. Hedex Installation

 Appendix. Win10 Compatibility problem with VirtualBox

Module I <Related Files Preparation> includes the installation files and Hedex technology files.

Module II <eNSP Installation> includes four sub-parts:

 Part I. BIOS Setting

 Part II. VirtualBox Installation (Only for Windows 10)

 Part III. eNSP Installation

 Part IV. USG6000V imagine Importing

Module III. <Hedex Installation> covers the Hedex Huawei document reading tool installation.

Appendix. Win10 Compatibility problem with VirtualBox.

Module I - <Related Files Preparation>


 Download installation files for the following installation:

 eNSP installation Package (eNSP V100R003C00SPC100)

 USG6000V Package (compatible with eNSP V100R003C00SPC100)

 Hedex installation Package

*** (Only for Windows 10) Warning: eNSP must be run with the VirtualBox.

But unfortunately, the different Windows 10 version (including update version)

compatibility with VirtualBox is different. The following version of VirtualBox is

recommend:
2019-12-16
Examination Environment Preparation

 *** VirtualBox 5.2.28

 *** VirtualBox 5.0.30

 Download the Hedex technology files(AR,USG,S5700)(after you download you

need to change the file suffix with *.hdx), and put them into the <eNSP Configuration

Reference> folder. And Put this folder in the exam PC desktop.

Module II <eNSP Installation>


Exam PC System requirement: Please refer to the System Configuration.

Item Minimum Configuration Recommended Configuration

CPU Dual-core 2.0 GHz or faster (Inter i5 or above is recommended)

Memory (GB) 4 8 above (Recommended)

Free disk space (GB) 10 20 above(Recommended)

Operating system Windows 7 (Recommended)


Windows 10

VirtualBox win7: VirtualBox 4.2.3 above (included in eNSP installation


file)
win10: the above mentioned version VirtualBox

We recommend using the win 7 system with 8 GB memory as the exam PC.

Note:

 Strongly recommend choosing the high-quality PC as the exam PC.

 Recommend to prepare some PC as the redundancy PC in case of PC fault accident

happen the exam period.

Part I. BIOS Setting


In order to add USG6000V, firstly enable virtualization in BIOS of the exam PC.

(You can search “How to access BIOS” in Google search)

2019-12-16
Examination Environment Preparation

Move the cursor to Virtualization and click Enter.

NOTE:

BIOS pages on different computers may be different. The example is only for reference.

On the Virtualization page, set the Intel (R) Virtualization Technology to Enabled.

Save and exit the BIOS view to enter the operating system.

Part II. VirtualBox Installation


Install the newest VirtualBox version as the installation tips.

2019-12-16
Examination Environment Preparation

(un-check the “Create a shortcut on the desktop” option to avoid the student change or
delete the setting in the VirtualBox)
Note:
No need to change the other thing in the installation process.

Part III. eNSP Installation


Step 1 Install eNSP.
Regardless of whether the purpose is to study the network, reproduce a
problem on a live network, or run a pre-project delivery simulation,
verification must be simulated. However, practice, there is often a lack of
the actual device needed for physical testing, and so eNSP has been
designed to easily create a virtual network to simulate the actual network
environment for testing purposes.
Because each simulated device occupies a certain amount of memory on
eNSP, the minimum configuration requirements for a system running
eNSP are: 2.0 GHz or higher dual-core CPU; 2 GB (4 GB-
Recommended) of RAM, 2 GB (4 GB-Recommended) of free disk
space, and either Windows 7(Recommended) or Windows 10 running
as the operating system.
Before installing eNSP, check the status of the system configuration.
Ensure that the minimum configuration requirements are met and then
perform the installation through the following steps:
Step 2 Double-click the eNSP installation file. The installation wizard dialog box is
displayed.
Step 3 Change the installation language to English (the default setting is Chinese)
and click OK.

2019-12-16
Examination Environment Preparation

Step 4 The welcome window is displayed. Then, click the Next button, as shown in
Figure 1-1.

Figure 1-1 Welcome window

Step 5 Select the installation location (the path cannot contain non-English
characters). Then, click the Next button, as shown in Figure 1-2.

2019-12-16
Examination Environment Preparation

Figure 1-2 Selecting the installation location

Step 6 Select the Start menu folder in which the eNSP program shortcut will appear.
Then, click the Next button, as shown in Figure 1-3.

Figure 1-3 Selecting the Start menu folder in which the program shortcuts will
be created

2019-12-16
Examination Environment Preparation

Step 7 Choose whether to create a program shortcut on the desktop. Then, click the
Next button, as shown in Figure 1-4.

Figure 1-4 Choosing whether to create a shortcut on the desktop

Step 8 Select the software to be installed. Note: For initial installations, select every
software option. Then, click the Next button, as shown in Figure 1-5.

Figure 1-5 Installing other programs

2019-12-16
Examination Environment Preparation

Remark:If the exam PC Operation System is WIN 10, please un-check the VirtualBox option

Step 9 Confirm the installation information. Then, click the Install button to start the
installation, as shown in Figure 1-6.

Figure 1-6 Preparing to install

Step 10 If you do not want to open eNSP immediately after the installation is finished,
deselect the Launch eNSP check box. Click the Finish button to complete the
installation, as shown in Figure 1-7.

Figure 1-7 Completing the installation

2019-12-16
Examination Environment Preparation

Part IV. USG6000V Package Importing


Step 1 Download the USG6000V.zip from the newest eNSP download website for
the next step procedure.

Figure 1-1 USG6000V Download website

Step 2 Add USG6000V in eNSP:


Click and Open the eNSP application. Follow the following action to add the
USG6000V.

2019-12-16
Examination Environment Preparation

Try to run the USG6000V after importing the USG6000V package.


If needed, remove the old base images from VirtualBox and register devices
from eNSP Menu>Tools>Register device.
More information please refer to the following topic in the eNSP help file:
<FAQ-How to Add USG6000V>

2019-12-16
Examination Environment Preparation

<FAQ- How to Solve the Problem of USG6000V Start Failure>

2019-12-16
Examination Environment Preparation

Checking
Check if the environment is Ready for the eNSP examination.

Warning: especially USG6000V running verification need to double-check.

Step 1 Select the Router ,S5700 and USG6000V. Press the Start Button .

2019-12-16
Examination Environment Preparation

Step 2 Wait several minutes, and double click the USG6000V and Router

,S5700 to check if they can run well.

(The above screen tells us the USG FireWall is running.)


Note: Default username :admin ,
Password:Admin@123

2019-12-16
Examination Environment Preparation

(The above screen tells us the Router is running.)

The above screen tells us the S5700 is running.)


More information please refer to the following topic in the eNSP help file:

Note: Ignore the following Pop windows when you open the eNSP:
2019-12-16
Examination Environment Preparation

Module III. Hedex Installation


Download and Install the huawei document reading tool: HedEx Lite.

Put <eNSP Configuration Reference> folder in the exam’s PC desktop.

Checking
Try to open the file (*.hdx) in the above folder to check if the Hedex is Ready for the

huawei technological electronic document reading.

Note: After you download you need to change the file suffix with *.hdx).

(AR & AC & USG6000V & Switch technology document)

(Double click AR technology document Open by Hedex Lite)

2019-12-16
Examination Environment Preparation

Appendix. Win10 Compatibility problem with VirtualBox


Because the USG6000V should be working with VirtualBox application. The newest Windows 10

version lack of the compatibility with some VirtualBox version.

If blue screen happen in the windows 10 environment, try to remove the VirtualBox & eNSP first,

re-install the virtualbox 4.3.12 version & eNSP to solve the compatibility problem.

Note: Use the windows administrator role to execute the following steps.

Step 1. Remove the eNSP application, and clear (delete) all the file in the installation folder. (such

as: “C:\Program Files\Huawei\eNSP”).

Step 2. Remove the current VirtualBox application, and clear (delete) all the file in the installation

folder. (such as: “C:\Program Files\Oracle\VirtualBox”)

Step 3. Restart the PC.

Note:

Step 1&2&3 execution aim to make sure it is a clear installation environment.

Step 4. Install another version VirtualBox first.

Step 5. Install the eNSP after the installation of VirtualBox.

Step 6. Import the USG6000V package, refer to the Part IV of Module II <eNSP Installation>

Finally, check if you can run the USG6000V in the eNSP.

Note: If needed, remove the old base images from VirtualBox and register devices from eNSP

Menu>Tools>Register device.

Refer the FAQ in eNSP help and this huawei support case.

Any question please contact Huawei for the support. (Email Contact: yinhenghai@huawei.com)

----End

2019-12-16

Вам также может понравиться