CERTIFICATE OF ACCREDITATION

ANSI National Accreditation Board


11617 Coldwater Road, Fort Wayne, IN 46845 USA

This is to certify that

CalTek Electronics Joint Stock Co.


03rd Floor Ha Nam Plaza, West Quarter, Vinh Phu Ward
Thuan An Town, Binh Duong Province, Vietnam
(and satellite location as shown on the scope)
has been assessed by ANAB and meets the requirements of international standard

ISO/IEC 17025:2017
while demonstrating technical competence in the field of

CALIBRATION
Refer to the accompanying Scope of Accreditation for information regarding the types of
activities to which this accreditation applies

AC-2478
Certificate Number

Certificate Valid Through: 06/23/2021


Version No. 004 Issued: 06/18/2019

This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017.
This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory
quality management system (refer to joint ISO-ILAC-IAF Communiqué dated April 2017).
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017

CalTek Electronics Joint Stock Company


rd
03 Floor Ha Nam Plaza, West Quarter, Vinh Phu Ward
Thuan An Town, Binh Duong Province, Vietnam
Nhat Le Phone : 84-936384075
Nhat.le@caltek.com.vn

CALIBRATION
Valid to: June 23, 2021 Certificate Number: AC-2478

Acoustics and Vibration


Reference Standard,
Expanded Uncertainty of
Parameter/Equipment Range Method and/or
Measurement (+/-)
Equipment
Soundtek ST-120 Sound
Sound Level Meter1 (94 & 114) dB, 1 kHz 0.71 dB
Level Calibrator
Vibration1
Acceleration 9.8 m/s2, 159 Hz
4.3 % of reading PCB Calibration Exciter
Velocity 9.8 mm/s, 159 Hz
Displacement 9.9 µm

Chemical Quantities
Reference Standard,
Expanded Uncertainty of
Parameter/Equipment Range Method and/or
Measurement (+/-)
Equipment
4.00 pH 0.021 pH
pH Measure 7.00 pH 0.023 pH
10.00 pH 0.022 pH
84 µS/cm 1.9 µS/cm Reagecon solutions
1413 µS/cm 25 µS/cm
Conductivity – Measure
12.88 mS/cm 0.23 mS/cm
111.8 mS/cm 1.9 mS/cm

Version 004 Issued: June 18, 2019 www.anab.org

Page 1 of 20
Electrical – DC/Low Frequency
Reference Standard,
Expanded Uncertainty of
Parameter/Equipment Range Method, and/or
Measurement (+/-)
Equipment
Up to 100 mV 0.004 9 mV + 0.000 088 mV/mV
100 mV to 1 V 0.00 0057 V + 0.000 047 V/V
Agilent 34401A
DC Voltage - Measure1 (1 to 10) V 0.000 046 V + 0.000 066 V/V
Multimeter
(1V to 100) V 0.003 8 V + 0.000 055 V/V
(100 to 1 000) V 0.013 V + 0.000 079 V/V
(0 to 10) mA 0.002 3 mA + 0.000 6 mA / mA
(10 to 100) mA 0.005 7 mA + 0.000 61 mA / mA
Agilent 34401A
DC Current - Measure1 100 mA to 1 A 0.000 098 A + 0.001 3 A / A
Multimeter
(1 to 3) A 0.000 68 A + 0.001 5 A / A

Agilent 34401A
DC Current - Measure1 (3 to 200) A 0.1 mA + 13 mA / A
Multimeter, Current Shunt
(0 to 329.999 9) mV 0.003 5 mV + 0.000 07 mV / mV
(0 to 3.299 999) V 0.000 012 V + 0.000 056 V / V
Fluke 5502A Multiproduct
DC Voltage -Source (0 to 32.999 99) V 0.000 12 V + 0.000056 V / V
Calibrator
(30 to 329.999 9) V 0.000 78 V + 0.000 063 V / V
(100 to 1 020) V 0.002 V + 0.000 064 V / V
(0 to 329.999) µA 0.023 uA + 0.000 36 uA/uA
(0 to 3.299 99) mA 0.000 083 mA + 0.000 11 mA/mA
(0 to 32.999 9) mA 0.000 39 mA + 0.000 11 mA/mA
(0 to 329.999) mA 0.005 4 mA + 0.000 11 mA/mA Fluke 5502A Multiproduct
DC Current – Source
(0 to 1.099 99) mA 0.000 031 A + 0.000 41 A/A Calibrator
(1.1 to 2.999 99) A 0.000 065 A + 0.000 44 A/A
(0 to 10.999 9) A 0.001 5 A + 0.000 63 A/A
(11 to 20.5) A 0.000 67 A + 0.001 2 A/A
Fluke 5502A Multiproduct
DC Current – Simulate 20.5 to 1000A 0.38 A + 5.5 mA / A
Calibrator, Current Coil
Up to 100 mV
(1to 50) Hz 0.046 mV + 0.000 69 mV/mV
(50 to 1 000) Hz 0.046 mV + 0.000 69 mV/mV
(1 to 20) kHz 0.046 mV + 0.000 69 mV/mV
(0.1 to 1) V Agilent 34401A
AC Voltage – Measure1
(1to 50) Hz 0.000 4 V + 0.000 65 V/V Multimeter
(50 to 1000) Hz 0.000 4 V + 0.000 65 V/V
(1to 20) kHz 0.000 4 V + 0.000 65 V/V
(20 to 50) kHz 0.000 61 V + 0.001 4 V/V
(50 to 100) kHz 0.000 95 V + 0.006 9 V/V

Version 004 Issued: June 18, 2019 www.anab.org

Page 2 of 20
Electrical – DC/Low Frequency
Reference Standard,
Expanded Uncertainty of
Parameter/Equipment Range Method, and/or
Measurement (+/-)
Equipment
(1 to 10) V
(1 to 50) Hz 0.003 5 V + 0.000 69 V/V
(50 to 1000) Hz 0.003 5 V + 0.000 69 V/V
(1 to 20) kHz 0.003 5 V + 0.000 69 V/V
(20 to 50) kHz 0.005 8 V + 0.001 4 V/V
(50 to 100) kHz 0.009 2 V + 0.000 69 V/V
(10 to 100) V
(1 to 50) Hz 0.035 V + 0.000 69 V/V Agilent 34401A
AC Voltage – Measure1
(50 to 1000) Hz 0.035 V + 0.000 69 V/V Multimeter
(1 to 20) kHz 0.035 V + 0.000 69 V/V
(20 to 50) kHz 0.058 V + 0.001 4 V/V
(50 to 100) kHz 0.092 V + 0.006 9 V/V
(100 to 750) V
(1 to 50) Hz 0.26 V + 0.000 69 V/V
(50 to 500) Hz 0.26 V + 0.000 69 V/V
(0.5 to 1) kHz 0.26 V + 0.000 69 V/V
(1 to 32.999) mV
(10 to 45) Hz 0.023 mV + 0.001 7 mV/mV
45 Hz to 10 kHz 0.023 mV + 0.001 2 mV/mV
(10 to 20) kHz 0.023 mV + 0.001 7 mV/mV
(20 to 50) kHz 0.023 mV + 0.002 3 mV/mV
(50 to 100) kHz 0.038 mV + 0.004 mV/mV
(100 to 500) kHz 0.071 mV + 0.011 mV/mV
(33 to 329.999) mV
(10 to 45) Hz 0.023 mV + 0.000 58 mV/mV
45 Hz to 10 kHz 0.019 mV + 0.000 36 mV/mV
Fluke 5502A Multiproduct
AC Voltage -Source (10 to 20) kHz 0.023 mV + 0.000 81 mV/mV
Calibrator
(20 to 50) kHz 0.047 mV + 0.001 2 mV/mV
(50 to 100) kHz 0.2 mV + 0.002 6 mV/mV
(100 to 500) kHz 0.39 mV + 0.005 8 mV/mV
(0.33 to 3.299 99) V
(10 to 45) Hz 0.071 mV + 0.000 58 V/V
45 Hz to 10 kHz 0.072 mV + 0.000 35 V/V
(10 to 20) kHz 0.69 mV + 0.000 81 V/V
(20 to 50) kHz 0.7 mV + 0.001 2 V/V
(50 to 100) kHz 0.24 mV + 0.002 7 V/V
(100 to 500) kHz 0.001 2 V + 0.005 8 V/V

Version 004 Issued: June 18, 2019 www.anab.org

Page 3 of 20
Electrical – DC/Low Frequency
Reference Standard,
Expanded Uncertainty of
Parameter/Equipment Range Method, and/or
Measurement (+/-)
Equipment
(3.3 to 32.999 9) V
(10 to 45) Hz 0.94 mV + 0.000 5773 V/V
45 Hz to 10 kHz 0.72 mV + 0.000 35 V/V
(10 to 20) kHz 0.8 mV + 0.000 81 V/V
(20 to 50) kHz 0.84 mV + 0.00 12 V/V
(50 to 100) kHz 0.002 4 V + 0.002 7 V/V
(33 to 329.999) V
(10 to 45) Hz 0.003 7 V + 0.000 58 V/V Fluke 5502A Multiproduct
AC Voltage -Source
45 Hz to 10 kHz 0.011 V + 0.000 92 V/V Calibrator
(10 to 20) kHz 0.012 V + 0.001 V/V
(20 to 50) kHz 0.014 V + 0.001 4 V/V
(50 to 100) kHz 0.11 V + 0.002 7 V/V
(330 to 1 020) V
45 Hz to 1 kHz 0.023 V + 0.000 58 V/V
(1 to 5) kHz 0.025 V + 0.000 92 V/V
(5 to 10) kHz 0.026 V + 0.001 V/V
(29 to 329.99) µA
(10 to 20) Hz 0.12 uA + 0.002 3 uA/uA
(20 to 45) Hz 0.12 uA + 0.001 7 uA/uA
45 Hz to 1 kHz 0.12 uA + 0.001 4 uA/uA
(1 to 5) kHz 0.21 uA + 0.003 4 uA/uA
(5 to 10) kHz 0.23 uA + 0.009 3 uA/uA
(10 to 30) kHz 0.77 uA + 0.007 7 uA/uA
(0.33 to 3.299 99) mA
(10 to 20) Hz 0.000 21 mA + 0.002 3 mA/mA
(20 to 45) Hz 0.000 2 mA + 0.001 4 mA/mA
Fluke 5502A Multiproduct
AC Current – Source 45 Hz to 1 kHz 0.000 2 mA + 0.001 1 mA/mA
Calibrator
(1 to 5) kHz 0.000 26 mA + 0.002 3 mA/mA
(5 to 10) kHz 0.000 37 mA + 0.005 8 mA/mA
(10 to 30) kHz 0.000 75 mA + 0.011 mA/mA
(3.3 to 32.99 99) mA
(10 to 20) Hz 0.003 4 mA + 0.0029 mA/mA
(20 to 45) Hz 0.02 mA + 0.000 69 mA/mA
45 Hz to 1 kHz 0.001 6 mA + 0.000 81 mA/mA
(1 to 5) kHz 0.002 7 mA + 0.000 92 mA/mA
(5 to 10) kHz 0.003 6 mA + 0.002 3 mA/mA
(10 to 30) kHz 0.004 8 mA + 0.004 6 mA/mA

Version 004 Issued: June 18, 2019 www.anab.org

Page 4 of 20
Electrical – DC/Low Frequency
Reference Standard,
Expanded Uncertainty of
Parameter/Equipment Range Method, and/or
Measurement (+/-)
Equipment
(33 to 329.999) mA
(10 to 20) Hz 0.035 mA + 0.002 mA/mA
(20 to 45) Hz 0.03 mA + 0.001 mA/mA
45 Hz to 1 kHz 0.025 mA + 0.000 46 mA/mA
(1 to 5) kHz 0.059 mA + 0.001 2 mA/mA
(5 to 10) kHz 0.12 mA + 0.002 3 mA/mA
(10 to 30) kHz 0.23 mA + 0.004 6 mA/mA
(0.33 to 1.099 99) A
(10 to 45) Hz 0.000 12 A + 0.002 1 A/A
45 Hz to 1 kHz 0.000 03 A + 0.000 46 A/A
(1 to 5) kHz 0.001 2 A + 0.006 9 A/A
(5 to 10) kHz 0.005 8 A + 0.028 A/A
Fluke 5502A Multiproduct
AC Current – Source (1 to 2.999 99) A
Calibrator
(10 to 45) Hz 0.000 13 A + 0.002 A/A
45 Hz to 1 kHz 0.000 16 A + 0.000 69 A/A
(1 to 5) kHz 0.001 2 A + 0.007 A/A
(5 to 10) kHz 0.005 9 A + 0.028 A/A
(3 to 10.999 9) A
(10 to 45) Hz 0.002 4 A + 0.000 69 A/A
45 Hz to 1 kHz 0.002 4 A + 0.001 2 A/A
(1 to 5) kHz 0.002 4 A + 0.034 A/A
(11 to 20.5) A
(45 to 100) Hz 0.005 8 A + 0.001 4 A/A
100 Hz to 1 kHz 0.005 9 A + 0.001 4 A/A
(1 to 5) kHz 0.0058 A + 0.03465 A/A
(20.5 to 1 000) A Fluke 5502A Multiproduct
AC Current – Simulate 50 Hz 0.34 A + 7.8 mA/A Calibrator, Current Coil
(0 to 1) A
(1 to 50) Hz 0.000 39 A + 0.002 4 A / A
(50 to 1 000) Hz 0.000 67 A + 0.000 64 A / A Agilent 34401A
AC Current – Measure1
(1 to 3) A Multimeter
(1 to 50) Hz 0.001 8 A + 0.002 6 A / A
(50 to 1 000) Hz 0.001 9 A + 0.002 A / A
Oscilloscopes1 -
Amplitude - DC Signal Fluke 5520A/SC300
50 Ω Load (0 to 2.2) V 4.6 mV + 1.7 mV/V Multiproduct Calibrator
1 MΩ Load (0 to 33) V 26 mV + 3 mV/V

Version 004 Issued: June 18, 2019 www.anab.org

Page 5 of 20
Electrical – DC/Low Frequency
Reference Standard,
Expanded Uncertainty of
Parameter/Equipment Range Method, and/or
Measurement (+/-)
Equipment
Oscilloscopes1 -
Amplitude - Square Wave
50 Ω Load 1.8 mVp-p to 2.2 Vp-p
10 Hz to 10 kHz 1.2 mV + 3 mV/V
1 MΩ Load 1.8 mVp-p to 105 Vp-p
10 Hz to 10 kHz 4.5 mV + 5 mV/V

Levelled Sine Wave 5 mV to 5.5 V


50 kHz 4.6 mV + 25 mV/V
50 kHz to 100 MHz 5.1 mV + 44 mV/V Fluke 5520A/SC300
(100 to 300) MHz 3.6 mV + 51 mV/V Multiproduct Calibrator

Time Marker 5 s to 2 µs 0.85 ms + 6.3 ms/s


1 µs to 2 ns 1.2 ns
Wave Generator (Square,
Sine, Triangle Wave) 1.8 mVp-p to 2.2 Vp-p
50 Ω Load 10 Hz to 100 kHz 0.38 mV + 39 mV/V

1 MΩ Load 1.8 mVp-p to 55 Vp-p 1.7 mV + 39 mV/V


10 Hz to 100 kHz
(0 to 10) Ω 0.004 2 Ω + 0.000 11 Ω/Ω
(10 to 100) Ω 0.026 Ω + 0.000 047 Ω/Ω
DC Resistance1 General Radio 1433-M
(100 to 1 000) Ω 0.06 Ω + 0.000 11 Ω/Ω
(LCR Meters) Decade Resistor
(1 to 10) kΩ 0.001 kΩ + 0.000 086 kΩ/kΩ
(10 to 100) kΩ 0.005 8 kΩ + 0.000 06 kΩ/kΩ
(10 to 100) pF 5.8 pF + 0.055 pF/pF
(100 to 1 000) pF 5.9 pF + 0.005 7 pF/pF
Capacitance1 General Radio 1412-BC
(1 000 to 10 000) pf 8.2 pF+0.005 6 pF/pF
(LCR Meters - 1 kHz) Decade Capacitor
(0.01 to 0.1) µF 0.0058 µF + 0.005 8 µF/µF
(0.1 to 1) µF 0.0058 µF + 0005 8 µF/µF
(1 to 10) mH 0.000 1 mH + 0.009 3 mH/mH
Inductance1 (10 to 100) mH 0.001 6 mH + 0.009 3 mH/mH General Radio 1490-D
(LCR Meters - 1 kHz) (100 to 1 000) mH 0.008 6 mH + 0.009 3 mH/mH Decade Inductor
(1 to10) H 0.000 08 H + 0.009 3 H/H
(0 to 2) kV 0.023 kV + 0.0013 kV/kV HP 34401A Multimeter,
HiPot Testers1
(2 to 10) kV 0.23 kV + 0.002 V/kV HV Probe
Up to 20 kV 0.00013 kV + 0.023 kV/kV HP 34401A Multimeter,
Withstanding/Insulation
(0 to 100) MΩ 0.042 MΩ + 0.0019 MΩ/MΩ HV Probe, Insulation
Testers1
(0.1 to 20) GΩ 0.034 GΩ + 0.056 GΩ/GΩ Tester Calibrator

Version 004 Issued: June 18, 2019 www.anab.org

Page 6 of 20
Electrical – DC/Low Frequency
Reference Standard,
Expanded Uncertainty of
Parameter/Equipment Range Method, and/or
Measurement (+/-)
Equipment
(0 to 10.999) Ω 0.001 9 Ω + 0.000 11 Ω/Ω
(11 to 32.999) Ω 0.002 Ω + 0.000 13 Ω/Ω
(33 to 109.999) Ω 0.001 8 Ω + 0.000 1 Ω/Ω
(110 to 329.999) Ω 0.002 4 Ω + 0.000 1 Ω/Ω
(0.33 to 1.099 99) kΩ 0.025 Ω + 0.000 1 kΩ/kΩ
(1.1 to 3.299 99) kΩ 0.024 Ω + 0.000 1 kΩ/kΩ
(3.3 to 11) kΩ 0.074 Ω + 0.000 1 kΩ/kΩ
(11 to 32.999 9) kΩ 0.24 Ω + 0.000 1 kΩ/kΩ
Fluke 5502A Multiproduct
Resistance – Source (33 to 109.999) kΩ 0.44 Ω + 0.000 13 kΩ/kΩ
Calibrator
(110 to 329.999) kΩ 0.0024 kΩ + 0.000 14 kΩ/kΩ
330 kΩ to 1.099 99 MΩ 0.0055 kΩ + 0.000 17 MΩ/MΩ
(1.1 to 3.299 99) MΩ 0.035 kΩ + 0.000 17 MΩ/MΩ
(3.3 to 10.999 9) MΩ 0.061 kΩ + 0.000 69 MΩ/MΩ
(11 to 32.999 9) MΩ 0.0029 MΩ + 0.001 2 MΩ/MΩ
(33 to 109.999) MΩ 0.0034 MΩ + 0.005 8 MΩ/MΩ
(110 to 329.999) MΩ 0.12 MΩ + 0.005 8 MΩ/MΩ
(330 to 1 100) MΩ 0.57 MΩ + 0.017 MΩ/MΩ
(0 to 100) Ω 0.005 Ω + 0.000 17 Ω/Ω
(100 to 1 000) Ω 1.6 mΩ + 0.000 18 kΩ/kΩ
1 k Ω to 10 kΩ 0.11 Ω + 0.000 16 kΩ/kΩ
Agilent 34401A
Resistance – Measure1 (10 to 100) kΩ 0.53 Ω + 0.000 18 kΩ/kΩ
Multimeter
(0.1 to 1) MΩ 0.017 Ω + 0.000 2 MΩ/MΩ
(1 to 10) MΩ 0.73 kΩ + 0.000 77 MΩ/MΩ
(10 to 100) MΩ 0.073 MΩ + 0.011 MΩ/MΩ
Capacitance –
10 Hz to 10 kHz (220 to 399.9) pF 12 pF + 0.005 8 pF/pF
10 Hz to 10 kHz 400 pF to 1.099 9 nF 0.012 nF + 0.005 7 nF/nF
10 Hz to 3 kHz (1.1 to 3.299 9) nF 0.012 nF + 0.005 8 nF/nF
10 Hz to 1 kHz (3.3 to 10.999) nF 0.012 nF + 0.002 9 nF/nF
10 Hz to 1 kHz (11 to 32.999) nF 0.12 nF + 0.002 9 nF/nF
10 Hz to 1 kHz (33 to 109.99) nF 0.12 nF + 0.002 9 nF/nF
10 Hz to 1 kHz (110 to 329.99) nF 0.35 nF + 0.002 937 nF/nF Fluke 5502A Multiproduct
(10 to 600) Hz (0.33 to 1.099 9) μF 0.001 1 µF + 0.003 µF/µF Calibrator
(10 to 300) Hz (1.1 to 3.299 9) μF 0.003 4 µF + 0.003 µF/µF
(10 to 150) Hz (3.3 to 10.999) μF 0.011 µF + 0.003 µF/µF
(10 to 120) Hz (11 to 32.999) μF 0.035 µF + 0.004 7 µF/µF
(10 to 80) Hz (33 to 109.99) μF 0.11 µF + 0.005 4 µF/µF
(10 to 50) Hz (110 to 329.99) μF 0.36 µF + 0.005 2 µF/µF
(10 to 20) Hz 330 μF to 1.099 9 mF 0.001 2 mF + 0.005 2 mF/mF
(0 to 6) Hz (1.1 to 3.299 9) mF 0.003 5 mF + 0.005 2 mF/mF

Version 004 Issued: June 18, 2019 www.anab.org

Page 7 of 20
Electrical – DC/Low Frequency
Reference Standard,
Expanded Uncertainty of
Parameter/Equipment Range Method, and/or
Measurement (+/-)
Equipment
Capacitance –
(0 to 2) Hz (3.3 to 10.999) mF 0.012 mF + 0.005 2 mF/mF Fluke 5502A Multiproduct
(0 to 0.6) Hz (11 to 32.999) mF 0.041 mF + 0.0084 mF/mF Calibrator
(0 to 0.2) Hz (33 to 110) mF 0.12 mF + 0.013 mF/mF
Type E
(-250 to -100) ºC 0.59 ºC
(-100 to -25) ºC 0.59 ºC
(-25 to 350) ºC 0.24 ºC
(350 to 650) ºC 0.26 ºC
(650 to 1 000) ºC 0.28 ºC
Type J
(-210 to -100) ºC 0.34 ºC
Electrical Calibration of (-100 to -30) ºC 0.25 ºC Fluke 5502A Multiproduct
Thermocouple Indicators (-30 to 150) ºC 0.22 ºC Calibrator
(150 to 760) ºC 0.25 ºC
(760 to 1 200) ºC 0.31 ºC
Type K
(-200 to -100) ºC 0.41 ºC
(-100 to -25) ºC 0.28 ºC
(-25 to 120) ºC 0.24 ºC
(120 to 1 000) ºC 0.36 ºC
(1 000 to 1 372) ºC 0.49 ºC

Electrical – RF/Microwave
Reference Standard,
Expanded Uncertainty of
Parameter/Equipment Range Method, and/or
Measurement (+/-)
Equipment
RF Power- Source1
(-70 to 0) dBm 1.8 dB
100 kHz to 123 MHz (0 to 7) dBm 1.3 dB
(7 to 13) dBm 1.8 dB Hewlett Packard 8656B
Signal Generator
(-70 to 0) dBm 1.3 dB
123 MHz to 990 MHz (0 to 7) dBm 1.3 dB
(7 to 13) dBm 1.8 dB
RF Power- Measure1 Agilent E4418B, HP
10 MHz to 18 GHz (-40 to 20) dBm 0.91 dB + 0.07 dB/dB
9300A Power Meter

Version 004 Issued: June 18, 2019 www.anab.org

Page 8 of 20
Length – Dimensional Metrology
Reference Standard,
Expanded Uncertainty of
Parameter/Equipment Range Method and/or
Measurement (+/-)
Equipment
Up to 600 mm
Calipers1 0.005 7 mm + 0.016 μm/mm Gage Blocks
(Up to 24 inch)
Up to 300 mm Optical Flat
Micrometers1 0.14 µm + 15 µm/mm
(Up to 12 in) Gage Blocks
Up to 600 mm
Height Gages1 0.011 mm + 0.019 μm/mm Gage Blocks
(Up to 24 inch)
Up to 125 mm
Depth Gages1 0.009 7 mm + 0.05 μm/mm Gage Blocks
(Up to 5 inch)
Coordinate Measuring
Ring Gage (10 to 300) mm 7.5 µm + 0.016 μm/mm
Machine
Coordinate Measuring
Bore Gage (10 to 500) mm 2.6 µm + 0.016 μm/mm
Machine
Thickness Gages – Measure Up to 12 mm
0.005 8 mm + 0.015 μm /mm Gage Blocks
Mode1 (Up to 0.4 inch)
Pin Gages, Plug Gages. Up to 25 mm
0.0013 mm + 0.00002 mm/mm High Accuracy Micrometer
Thread gages (Up to 1 inch)
Axis X: (0 to 600) mm
Coordinate Measuring
Axis Y: (0 to 600) mm 0.002 mm + 0.017 μm/mm Gage Blocks
Machines (CMM) 1
Axis Z: (0 to 500) mm
Measuring Microscopes, Up to 300 mm 300 mm Standard Glass
0.002 mm + 0.0026 mm/mm
Vision Systems – 2D1 (Up to 12 inch) Scale
Up to 300 mm 300 mm. Standard Glass
Profile Projectors1 0.002 mm + 0.0026 mm/mm
(Up to 12 inch) Scale
Coating Thickness
Coating Thickness Meters1 25 to 1 500 µm 2.9 µm
Standards

Indicators, Dial Indicators1 (0 to 25) mm 0.001 2 mm + 0.002 8 μm/mm Gage Blocks

Surface Roughness Testers1 GAR Precision Reference


16.1 µin 4.2 µin
Ra Mode Standard

Tape & Ruler (0 to 1 000) mm 0.58 mm + 0.1 mm/mm Gage Blocks


Surface Flatness –
Local Area Flatness1 (12 x 12 to 72 x 144) inch 0.000 17 in Mahr, Repeat-o-Meter
(Repeat Reading)

Version 004 Issued: June 18, 2019 www.anab.org

Page 9 of 20
Mass and Mass Related
Reference Standard,
Expanded Uncertainty of
Parameter/Equipment Range Method, and/or
Measurement (+/-)
Equipment
(5 to 50) N.m 0.022 N∙m + 0.018 N∙m/N∙m INSIZE IST-TT50
Torque Driver/Wrenches/
(10 to 100) lbf⋅in 0.046 lbf⋅ft+ 0.0098 lbf⋅ft/lbf⋅ft Mountz. LTT100i
Indicator/Gages1
(50 to 500) lbf⋅ft 0.001 lbf⋅ft + 0.013 lbf⋅ft/lbf⋅ft Mountz. BMX500F
1 mg to 20 g 0.000 04 g + 0.003 7 mg/g
(20 to 200) g 0.005 3 mg + 0.001 9 mg/g Shimadzu Balance, OIML
Mass/Weight
(500 to 2 000) g 0.002 1 g + 0.000 008 3 g/g Class E2, F1 Weight Sets
(5 to 20) kg 0.68 g + 0. 048 g/kg
1 mg to 200 g 0.068 mg + 0.001 8 mg/g
(200 to 500) g 0.39 mg + 0.006 6 mg/g OIML Class E2, M1, M2,
Scales/Balances1
(500 to 1 000) g 0.006 2 g + 0.003 6 mg/g F1 Weight Sets
(1 to 300) kg 0.014 kg + 0. 033 g/kg
Pressure calibrator Fluke
1 (-0.8 to 20) bar 0.007 bar
Pneumatic Gage Pressure 718-300G, Wika CPG1500
(0 to 680) bar 0.58 bar
Pressure Gauge
Pressure calibrator Fluke
(0 to 20) bar 0.007 bar
Hydraulic Gage Pressure1 718-300G, Wika CPG1500
(0 to 680) bar 0.58 bar
Pressure Gauge
Rockwell Hardness Testing 30 HRC 0.85 HRC
Machines1 50 HRC 0.84 HRC Indirect verification using
Yamamoto Scientific
Vickers Hardness Testing Standard Blocks
297 HV 6 HV
Machines1
Force Testing Machines
Load cell VLC 110
Compression & Tension1 0 to 4000 kgf 14 kgf + 0.001 2 kgf/kgf
Weight Sets F1, M1, M2
Force Gages1 0 to 20 kgf 0.02 kgf + 0.000 0018 kgf/kgf
Needle detector1 (0.8 to 5) mm 0.059 mm Test card
Durometers1 A, B, O, C, D, DO scales Shimadzu UX6200H
0.28 Duro
(Force Verification Only) (0 to 100) Duro Units Electronic Balance
Burette (1 to 100) ml 0.000 34 ml + 0.000 0011 ml/ml Analytical Scale Shimadzu
AUX 220
Pipettes & Micropipettes1 10 µl to 100 ml 0.000 25 ml + 0.000 0014 ml/ml UX 620H, UX 6200 H,
Jadever JWN-30k
Volumetric Flasks 1 ml to 20 l 1.4 ml + 0.000 13 ml/ml Weight Set

Version 004 Issued: June 18, 2019 www.anab.org

Page 10 of 20
Photometry and Radiometry
Reference Standard,
Expanded Uncertainty of
Parameter/Equipment Range Method, and/or
Measurement (+/-)
Equipment
Up to 800 Lux 4 % of reading + 1 Lux Konica Minolta CL-200A
Light Meters
(800 to 15 000) Lux 4 % of reading + 11 Lux Chroma Meter

Gloss Meters (37 & 97) GU, 60 ° 3 GU Reference Gloss Tiles

Thermodynamic
Reference Standard,
Expanded Uncertainty of
Parameter/Equipment Range Method, and/or
Measurement (+/-)
Equipment
(-25 to 0) °C 0.16 °C Temperature Calibrators
Temperature – Source1 (0 to 155) °C 0.17 °C MAGMAN 650H,
(120 to 650) °C 1.8 °C PRESYS T-25N
Ovens and Chambers Agilent 34970A Datalogger
(-25 to 600) °C 3 °C
Calibration and Profiling1 Thermocouple Type K
Temp. & Humidity Meter
Relative Humidity3 (30 to 90) %RH 3.0 %RH
Vaisala HMI41/HMP46
(-70 to 0) ºC 0.17 °C Presys RTD Display,
Temperature - Measure 1
(0 to 550) ºC 0.083 °C Accumac PRT

Time and Frequency


Reference Standard,
Expanded Uncertainty of
Parameter/Equipment Range Method, and/or
Measurement (+/-)
Equipment
(0.01 to 3 600) s
Stopwatches/Timers1 0.017 s + 0.000 012 s/s Agilent 53131A Counter
0.277 mHz to100 Hz)
Hewlett Packard 8656B
Frequency – Source1 (0.1 to 990) MHz 17 Hz + 48 nHz/Hz
Signal Generator
30 Hz to 500 Hz 5.1 µHz
1
Frequency – Measure 500 Hz to 225 MHz 0.98 Hz Agilent 53131A Counter
225 MHz to 3 GHz 22 Hz
Fluke 5502A Multiproduct
Tachometer (0 to 100 000) rpm 0.25 rpm + 0.000 013 rpm/rpm
Calibrator

Version 004 Issued: June 18, 2019 www.anab.org

Page 11 of 20
Services performed at satellite location
nd
02 Floor, Operation Center of Tien Son IP, Tien Son Street
Tien Son IP, Bac Ninh Province, Vietnam
Nhat Le Phone : 84-936384075
Nhat.le@caltek.com.vn
Calibration
Electrical – DC/Low Frequency
Parameter/Equipment Range Expanded Uncertainty of Reference Standard,
Measurement (+/-) Method, and/or
Equipment
Up to 100 mV 0.004 9 mV + 0.000 088 mV/mV
100 mV to 1 V 0.00 0057 V + 0.000 047 V/V
Agilent 34401A
DC Voltage - Measure1 (1 to 10) V 0.000 046 V + 0.000 066 V/V
Multimeter
(1V to 100) V 0.003 8 V + 0.000 055 V/V
(100 to 1 000) V 0.013 V + 0.000 079 V/V
(0 to 10) mA 0.002 3 mA + 0.000 6 mA / mA
(10 to 100) mA 0.005 7 mA + 0.000 61 mA / mA
Agilent 34401A
DC Current - Measure1 100 mA to 1 A 0.000 098 A + 0.001 3 A / A
Multimeter
(1 to 3) A 0.000 68 A + 0.001 5 A / A

Agilent 34401A
DC Current - Measure1 (3 to 200) A 0.1 mA + 13 mA / A
Multimeter, Current Shunt
(0 to 329.999 9) mV 0.003 5 mV + 0.000 07 mV / mV
(0 to 3.299 999) V 0.000 012 V + 0.000 056 V / V
Fluke 5502A Multiproduct
DC Voltage -Source (0 to 32.999 99) V 0.000 12 V + 0.000056 V / V
Calibrator
(30 to 329.999 9) V 0.000 78 V + 0.000 063 V / V
(100 to 1 020) V 0.002 V + 0.000 064 V / V
(0 to 329.999) µA 0.023 uA + 0.000 36 uA/uA
(0 to 3.299 99) mA 0.000 083 mA + 0.000 11 mA/mA
(0 to 32.999 9) mA 0.000 39 mA + 0.000 11 mA/mA
(0 to 329.999) mA 0.005 4 mA + 0.000 11 mA/mA Fluke 5502A Multiproduct
DC Current – Source
(0 to 1.099 99) mA 0.000 031 A + 0.000 41 A/A Calibrator
(1.1 to 2.999 99) A 0.000 065 A + 0.000 44 A/A
(0 to 10.999 9) A 0.001 5 A + 0.000 63 A/A
(11 to 20.5) A 0.000 67 A + 0.001 2 A/A
Fluke 5502A Multiproduct
DC Current – Simulate 20.5 to 1000A 0.38 A + 5.5 mA / A
Calibrator, Current Coil
Up to 100 mV
(1to 50) Hz 0.046 mV + 0.000 69 mV/mV Agilent 34401A
AC Voltage – Measure1
(50 to 1 000) Hz 0.046 mV + 0.000 69 mV/mV Multimeter
(1 to 20) kHz 0.046 mV + 0.000 69 mV/mV

Version 004 Issued: June 18, 2019 www.anab.org

Page 12 of 20
Electrical – DC/Low Frequency
Parameter/Equipment Range Expanded Uncertainty of Reference Standard,
Measurement (+/-) Method, and/or
Equipment
(0.1 to 1) V
(1to 50) Hz 0.000 4 V + 0.000 65 V/V
(50 to 1000) Hz 0.000 4 V + 0.000 65 V/V
(1to 20) kHz 0.000 4 V + 0.000 65 V/V
(20 to 50) kHz 0.000 61 V + 0.001 4 V/V
(50 to 100) kHz 0.000 95 V + 0.006 9 V/V
(1 to 10) V
(1 to 50) Hz 0.003 5 V + 0.000 69 V/V
(50 to 1000) Hz 0.003 5 V + 0.000 69 V/V
(1 to 20) kHz 0.003 5 V + 0.000 69 V/V
(20 to 50) kHz 0.005 8 V + 0.001 4 V/V Agilent 34401A
AC Voltage – Measure1
(50 to 100) kHz 0.009 2 V + 0.000 69 V/V Multimeter
(10 to 100) V
(1 to 50) Hz 0.035 V + 0.000 69 V/V
(50 to 1000) Hz 0.035 V + 0.000 69 V/V
(1 to 20) kHz 0.035 V + 0.000 69 V/V
(20 to 50) kHz 0.058 V + 0.001 4 V/V
(50 to 100) kHz 0.092 V + 0.006 9 V/V
(100 to 750) V
(1 to 50) Hz 0.26 V + 0.000 69 V/V
(50 to 500) Hz 0.26 V + 0.000 69 V/V
(0.5 to 1) kHz 0.26 V + 0.000 69 V/V
(1 to 32.999) mV
(10 to 45) Hz 0.023 mV + 0.001 7 mV/mV
45 Hz to 10 kHz 0.023 mV + 0.001 2 mV/mV
(10 to 20) kHz 0.023 mV + 0.001 7 mV/mV
(20 to 50) kHz 0.023 mV + 0.002 3 mV/mV
(50 to 100) kHz 0.038 mV + 0.004 mV/mV
(100 to 500) kHz 0.071 mV + 0.011 mV/mV Fluke 5502A Multiproduct
AC Voltage -Source
(33 to 329.999) mV Calibrator
(10 to 45) Hz 0.023 mV + 0.000 58 mV/mV
45 Hz to 10 kHz 0.019 mV + 0.000 36 mV/mV
(10 to 20) kHz 0.023 mV + 0.000 81 mV/mV
(20 to 50) kHz 0.047 mV + 0.001 2 mV/mV
(50 to 100) kHz 0.2 mV + 0.002 6 mV/mV
(100 to 500) kHz 0.39 mV + 0.005 8 mV/mV

Version 004 Issued: June 18, 2019 www.anab.org

Page 13 of 20
Electrical – DC/Low Frequency
Parameter/Equipment Range Expanded Uncertainty of Reference Standard,
Measurement (+/-) Method, and/or
Equipment
(0.33 to 3.299 99) V
(10 to 45) Hz 0.071 mV + 0.000 58 V/V
45 Hz to 10 kHz 0.072 mV + 0.000 35 V/V
(10 to 20) kHz 0.69 mV + 0.000 81 V/V
(20 to 50) kHz 0.7 mV + 0.001 2 V/V
(50 to 100) kHz 0.24 mV + 0.002 7 V/V
(100 to 500) kHz 0.001 2 V + 0.005 8 V/V
(3.3 to 32.999 9) V
(10 to 45) Hz 0.94 mV + 0.000 5773 V/V
45 Hz to 10 kHz 0.72 mV + 0.000 35 V/V
(10 to 20) kHz 0.8 mV + 0.000 81 V/V
Fluke 5502A Multiproduct
AC Voltage -Source (20 to 50) kHz 0.84 mV + 0.00 12 V/V
Calibrator
(50 to 100) kHz 0.002 4 V + 0.002 7 V/V
(33 to 329.999) V
(10 to 45) Hz 0.003 7 V + 0.000 58 V/V
45 Hz to 10 kHz 0.011 V + 0.000 92 V/V
(10 to 20) kHz 0.012 V + 0.001 V/V
(20 to 50) kHz 0.014 V + 0.001 4 V/V
(50 to 100) kHz 0.11 V + 0.002 7 V/V
(330 to 1 020) V
45 Hz to 1 kHz 0.023 V + 0.000 58 V/V
(1 to 5) kHz 0.025 V + 0.000 92 V/V
(5 to 10) kHz 0.026 V + 0.001 V/V
(29 to 329.99) µA
(10 to 20) Hz 0.12 uA + 0.002 3 uA/uA
(20 to 45) Hz 0.12 uA + 0.001 7 uA/uA
45 Hz to 1 kHz 0.12 uA + 0.001 4 uA/uA
(1 to 5) kHz 0.21 uA + 0.003 4 uA/uA
(5 to 10) kHz 0.23 uA + 0.009 3 uA/uA
(10 to 30) kHz 0.77 uA + 0.007 7 uA/uA Fluke 5502A Multiproduct
AC Current – Source
(0.33 to 3.299 99) mA Calibrator
(10 to 20) Hz 0.000 21 mA + 0.002 3 mA/mA
(20 to 45) Hz 0.000 2 mA + 0.001 4 mA/mA
45 Hz to 1 kHz 0.000 2 mA + 0.001 1 mA/mA
(1 to 5) kHz 0.000 26 mA + 0.002 3 mA/mA
(5 to 10) kHz 0.000 37 mA + 0.005 8 mA/mA
(10 to 30) kHz 0.000 75 mA + 0.011 mA/mA

Version 004 Issued: June 18, 2019 www.anab.org

Page 14 of 20
Electrical – DC/Low Frequency
Parameter/Equipment Range Expanded Uncertainty of Reference Standard,
Measurement (+/-) Method, and/or
Equipment
(3.3 to 32.99 99) mA
(10 to 20) Hz 0.003 4 mA + 0.0029 mA/mA
(20 to 45) Hz 0.02 mA + 0.000 69 mA/mA
45 Hz to 1 kHz 0.001 6 mA + 0.000 81 mA/mA
(1 to 5) kHz 0.002 7 mA + 0.000 92 mA/mA
(5 to 10) kHz 0.003 6 mA + 0.002 3 mA/mA
(10 to 30) kHz 0.004 8 mA + 0.004 6 mA/mA
(33 to 329.999) mA
(10 to 20) Hz 0.035 mA + 0.002 mA/mA
(20 to 45) Hz 0.03 mA + 0.001 mA/mA
45 Hz to 1 kHz 0.025 mA + 0.000 46 mA/mA
(1 to 5) kHz 0.059 mA + 0.001 2 mA/mA
(5 to 10) kHz 0.12 mA + 0.002 3 mA/mA
(10 to 30) kHz 0.23 mA + 0.004 6 mA/mA
(0.33 to 1.099 99) A
(10 to 45) Hz 0.000 12 A + 0.002 1 A/A Fluke 5502A Multiproduct
AC Current – Source
45 Hz to 1 kHz 0.000 03 A + 0.000 46 A/A Calibrator
(1 to 5) kHz 0.001 2 A + 0.006 9 A/A
(5 to 10) kHz 0.005 8 A + 0.028 A/A
(1 to 2.999 99) A
(10 to 45) Hz 0.000 13 A + 0.002 A/A
45 Hz to 1 kHz 0.000 16 A + 0.000 69 A/A
(1 to 5) kHz 0.001 2 A + 0.007 A/A
(5 to 10) kHz 0.005 9 A + 0.028 A/A
(3 to 10.999 9) A
(10 to 45) Hz 0.002 4 A + 0.000 69 A/A
45 Hz to 1 kHz 0.002 4 A + 0.001 2 A/A
(1 to 5) kHz 0.002 4 A + 0.034 A/A
(11 to 20.5) A
(45 to 100) Hz 0.005 8 A + 0.001 4 A/A
100 Hz to 1 kHz 0.005 9 A + 0.001 4 A/A
(1 to 5) kHz 0.0058 A + 0.03465 A/A
(20.5 to 1 000) A Fluke 5502A Multiproduct
AC Current – Simulate
50 Hz 0.34 A + 7.8 mA/A Calibrator, Current Coil
(0 to 1) A
(1 to 50) Hz 0.000 39 A + 0.002 4 A / A
(50 to 1 000) Hz 0.000 67 A + 0.000 64 A / A Agilent 34401A
AC Current – Measure1
(1 to 3) A Multimeter
(1 to 50) Hz 0.001 8 A + 0.002 6 A / A
(50 to 1 000) Hz 0.001 9 A + 0.002 A / A

Version 004 Issued: June 18, 2019 www.anab.org

Page 15 of 20
Electrical – DC/Low Frequency
Parameter/Equipment Range Expanded Uncertainty of Reference Standard,
Measurement (+/-) Method, and/or
Equipment
Oscilloscopes1 -
Amplitude - DC Signal
50 Ω Load (0 to 2.2) V 4.6 mV + 1.7 mV/V
1 MΩ Load (0 to 33) V 26 mV + 3 mV/V

Amplitude - Square Wave


50 Ω Load 1.8 mVp-p to 2.2 Vp-p
10 Hz to 10 kHz 1.2 mV + 3 mV/V
1 MΩ Load 1.8 mVp-p to 105 Vp-p
10 Hz to 10 kHz 4.5 mV + 5 mV/V

Levelled Sine Wave 5 mV to 5.5 V Fluke 5520A/SC300


50 kHz 4.6 mV + 25 mV/V Multiproduct Calibrator
50 kHz to 100 MHz 5.1 mV + 44 mV/V
(100 to 300) MHz 3.6 mV + 51 mV/V

Time Marker 5 s to 2 µs 0.85 ms + 6.3 ms/s


1 µs to 2 ns 1.2 ns
Wave Generator (Square,
Sine, Triangle Wave) 1.8 mVp-p to 2.2 Vp-p
50 Ω Load 10 Hz to 100 kHz 0.38 mV + 39 mV/V

1 MΩ Load 1.8 mVp-p to 55 Vp-p 1.7 mV + 39 mV/V


10 Hz to 100 kHz
(0 to 10) Ω 0.004 2 Ω + 0.000 11 Ω/Ω
(10 to 100) Ω 0.026 Ω + 0.000 047 Ω/Ω
DC Resistance1 General Radio 1433-M
(100 to 1 000) Ω 0.06 Ω + 0.000 11 Ω/Ω
(LCR Meters) Decade Resistor
(1 to 10) kΩ 0.001 kΩ + 0.000 086 kΩ/kΩ
(10 to 100) kΩ 0.005 8 kΩ + 0.000 06 kΩ/kΩ
(10 to 100) pF 5.8 pF + 0.055 pF/pF
(100 to 1 000) pF 5.9 pF + 0.005 7 pF/pF
Capacitance1 General Radio 1412-BC
(1 000 to 10 000) pf 8.2 pF+0.005 6 pF/pF
(LCR Meters - 1 kHz) Decade Capacitor
(0.01 to 0.1) µF 0.0058 µF + 0.005 8 µF/µF
(0.1 to 1) µF 0.0058 µF + 0005 8 µF/µF
(1 to 10) mH 0.000 1 mH + 0.009 3 mH/mH
Inductance1 (10 to 100) mH 0.001 6 mH + 0.009 3 mH/mH General Radio 1490-D
(LCR Meters - 1 kHz) (100 to 1 000) mH 0.008 6 mH + 0.009 3 mH/mH Decade Inductor
(1 to10) H 0.000 08 H + 0.009 3 H/H
(0 to 2) kV 0.023 kV + 0.0013 kV/kV HP 34401A Multimeter,
HiPot Testers1
(2 to 10) kV 0.23 kV + 0.002 V/kV HV Probe

Version 004 Issued: June 18, 2019 www.anab.org

Page 16 of 20
Electrical – DC/Low Frequency
Parameter/Equipment Range Expanded Uncertainty of Reference Standard,
Measurement (+/-) Method, and/or
Equipment
Up to 20 kV 0.00013 kV + 0.023 kV/kV HP 34401A Multimeter,
Withstanding/Insulation
(0 to 100) MΩ 0.042 MΩ + 0.0019 MΩ/MΩ HV Probe, Insulation
Testers1
(0.1 to 20) GΩ 0.034 GΩ + 0.056 GΩ/GΩ Tester Calibrator
(0 to 10.999) Ω 0.001 9 Ω + 0.000 11 Ω/Ω
(11 to 32.999) Ω 0.002 Ω + 0.000 13 Ω/Ω
(33 to 109.999) Ω 0.001 8 Ω + 0.000 1 Ω/Ω
(110 to 329.999) Ω 0.002 4 Ω + 0.000 1 Ω/Ω
(0.33 to 1.099 99) kΩ 0.025 Ω + 0.000 1 kΩ/kΩ
(1.1 to 3.299 99) kΩ 0.024 Ω + 0.000 1 kΩ/kΩ
(3.3 to 11) kΩ 0.074 Ω + 0.000 1 kΩ/kΩ
(11 to 32.999 9) kΩ 0.24 Ω + 0.000 1 kΩ/kΩ
Fluke 5502A Multiproduct
Resistance – Source (33 to 109.999) kΩ 0.44 Ω + 0.000 13 kΩ/kΩ
Calibrator
(110 to 329.999) kΩ 0.0024 kΩ + 0.000 14 kΩ/kΩ
330 kΩ to 1.099 99 MΩ 0.0055 kΩ + 0.000 17 MΩ/MΩ
(1.1 to 3.299 99) MΩ 0.035 kΩ + 0.000 17 MΩ/MΩ
(3.3 to 10.999 9) MΩ 0.061 kΩ + 0.000 69 MΩ/MΩ
(11 to 32.999 9) MΩ 0.0029 MΩ + 0.001 2 MΩ/MΩ
(33 to 109.999) MΩ 0.0034 MΩ + 0.005 8 MΩ/MΩ
(110 to 329.999) MΩ 0.12 MΩ + 0.005 8 MΩ/MΩ
(330 to 1 100) MΩ 0.57 MΩ + 0.017 MΩ/MΩ
(0 to 100) Ω 0.005 Ω + 0.000 17 Ω/Ω
(100 to 1 000) Ω 1.6 mΩ + 0.000 18 kΩ/kΩ
1 k Ω to 10 kΩ 0.11 Ω + 0.000 16 kΩ/kΩ
Agilent 34401A
Resistance – Measure1 (10 to 100) kΩ 0.53 Ω + 0.000 18 kΩ/kΩ
Multimeter
(0.1 to 1) MΩ 0.017 Ω + 0.000 2 MΩ/MΩ
(1 to 10) MΩ 0.73 kΩ + 0.000 77 MΩ/MΩ
(10 to 100) MΩ 0.073 MΩ + 0.011 MΩ/MΩ
Capacitance –
10 Hz to 10 kHz (220 to 399.9) pF 12 pF + 0.005 8 pF/pF
10 Hz to 10 kHz 400 pF to 1.099 9 nF 0.012 nF + 0.005 7 nF/nF
10 Hz to 3 kHz (1.1 to 3.299 9) nF 0.012 nF + 0.005 8 nF/nF
10 Hz to 1 kHz (3.3 to 10.999) nF 0.012 nF + 0.002 9 nF/nF
10 Hz to 1 kHz (11 to 32.999) nF 0.12 nF + 0.002 9 nF/nF
Fluke 5502A Multiproduct
10 Hz to 1 kHz (33 to 109.99) nF 0.12 nF + 0.002 9 nF/nF
Calibrator
10 Hz to 1 kHz (110 to 329.99) nF 0.35 nF + 0.002 937 nF/nF
(10 to 600) Hz (0.33 to 1.099 9) μF 0.001 1 µF + 0.003 µF/µF
(10 to 300) Hz (1.1 to 3.299 9) μF 0.003 4 µF + 0.003 µF/µF
(10 to 150) Hz (3.3 to 10.999) μF 0.011 µF + 0.003 µF/µF
(10 to 120) Hz (11 to 32.999) μF 0.035 µF + 0.004 7 µF/µF
(10 to 80) Hz (33 to 109.99) μF 0.11 µF + 0.005 4 µF/µF

Version 004 Issued: June 18, 2019 www.anab.org

Page 17 of 20
Electrical – DC/Low Frequency
Parameter/Equipment Range Expanded Uncertainty of Reference Standard,
Measurement (+/-) Method, and/or
Equipment
Capacitance –
(10 to 50) Hz (110 to 329.99) μF 0.36 µF + 0.005 2 µF/µF
(10 to 20) Hz 330 μF to 1.099 9 mF 0.001 2 mF + 0.005 2 mF/mF
Fluke 5502A Multiproduct
(0 to 6) Hz (1.1 to 3.299 9) mF 0.003 5 mF + 0.005 2 mF/mF
Calibrator
(0 to 2) Hz (3.3 to 10.999) mF 0.012 mF + 0.005 2 mF/mF
(0 to 0.6) Hz (11 to 32.999) mF 0.041 mF + 0.0084 mF/mF
(0 to 0.2) Hz (33 to 110) mF 0.12 mF + 0.013 mF/mF
Type E
(-250 to -100) ºC 0.59 ºC
(-100 to -25) ºC 0.59 ºC
(-25 to 350) ºC 0.24 ºC
(350 to 650) ºC 0.26 ºC
(650 to 1 000) ºC 0.28 ºC
Type J
(-210 to -100) ºC 0.34 ºC
Electrical Calibration of (-100 to -30) ºC 0.25 ºC Fluke 5502A Multiproduct
Thermocouple Indicators (-30 to 150) ºC 0.22 ºC Calibrator
(150 to 760) ºC 0.25 ºC
(760 to 1 200) ºC 0.31 ºC
Type K
(-200 to -100) ºC 0.41 ºC
(-100 to -25) ºC 0.28 ºC
(-25 to 120) ºC 0.24 ºC
(120 to 1 000) ºC 0.36 ºC
(1 000 to 1 372) ºC 0.49 ºC

Version 004 Issued: June 18, 2019 www.anab.org

Page 18 of 20
Electrical – RF/Microwave
Reference Standard,
Expanded Uncertainty of
Parameter/Equipment Range Method, and/or
Measurement (+/-)
Equipment
RF Power- Source1
(-70 to 0) dBm 1.8 dB
100 kHz to 123 MHz (0 to 7) dBm 1.3 dB
(7 to 13) dBm 1.8 dB Hewlett Packard 8656B
Signal Generator
(-70 to 0) dBm 1.3 dB
123 MHz to 990 MHz (0 to 7) dBm 1.3 dB
(7 to 13) dBm 1.8 dB
RF Power- Measure1 Agilent E4418B, HP
10 MHz to 18 GHz (-40 to 20) dBm 0.91 dB + 0.07 dB/dB
9300A Power Meter

Thermodynamic
Reference Standard,
Expanded Uncertainty of
Parameter/Equipment Range Method, and/or
Measurement (+/-)
Equipment
(-25 to 0) °C 0.16 °C Temperature Calibrators
Temperature – Source1 (0 to 155) °C 0.17 °C MAGMAN 650H,
(120 to 650) °C 1.8 °C PRESYS T-25N
Ovens and Chambers Agilent 34970A Datalogger
(-25 to 600) °C 3 °C
Calibration and Profiling1 Thermocouple Type K
Temp. & Humidity Meter
Relative Humidity3 (30 to 90) %RH 3.0 %RH
Vaisala HMI41/HMP46
(-70 to 0) ºC 0.17 °C Presys RTD Display,
Temperature - Measure 1
(0 to 550) ºC 0.083 °C Accumac PRT

Time and Frequency


Reference Standard,
Expanded Uncertainty of
Parameter/Equipment Range Method, and/or
Measurement (+/-)
Equipment
(0.01 to 3 600) s
Stopwatches/Timers1 0.017 s + 0.000 012 s/s Agilent 53131A Counter
0.277 mHz to100 Hz)
Hewlett Packard 8656B
Frequency – Source1 (0.1 to 990) MHz 17 Hz + 48 nHz/Hz
Signal Generator

Version 004 Issued: June 18, 2019 www.anab.org

Page 19 of 20
Time and Frequency
Reference Standard,
Expanded Uncertainty of
Parameter/Equipment Range Method, and/or
Measurement (+/-)
Equipment
30 Hz to 500 Hz 5.1 µHz
Frequency – Measure1 500 Hz to 225 MHz 0.98 Hz Agilent 53131A Counter
225 MHz to 3 GHz 22 Hz
Fluke 5502A Multiproduct
Tachometer (0 to 100 000) rpm 0.25 rpm + 0.000 013 rpm/rpm
Calibrator
Calibration and Measurement Capability (CMC) is expressed in terms of the measurement parameter, measurement range, expanded uncertainty of measurement and
reference standard, method, and/or equipment. The expanded uncertainty of measurement is expressed as the standard uncertainty of the measurement multiplied by a
coverage factor of 2 (k=2), corresponding to a confidence level of approximately 95%.
Notes:
1. On-site calibration service is available for this parameter, since on-site conditions are typically more variable than those in the laboratory, larger measurement
uncertainties are expected on-site than what is reported on the accredited scope
2. This scope is formatted as part of a single document including Certificate of Accreditation No. AC-2478.
3. The humidity is limited to the prevailing ambient conditions in the laboratory at the time of calibration.

Version 004 Issued: June 18, 2019 www.anab.org

Page 20 of 20