WL 110
Heat exchanger supply unit
x 2E
• supply unit for different heat ex- Reversing the water connections • in conjunction with a heat exchanger
changers changes the direction of flow and thus (WL 110.01 to WL 110.04)
(WL 110.01-WL 110.04) allows parallel flow or counterflow opera- · plotting temperature curves
• heat exchanger operation in par- tion. · determining the mean heat transfer
allel flow or counterflow possible coefficient
The main function of the WL 110 is to · comparing different heat exchanger
Heat exchangers transfer thermal en- provide the required cold and hot water types
ergy from the flow of one medium to an- circuits. To do this, the supply unit is
other. The two flows do not come into equipped with a heated tank and pump
direct contact with one another. Efficient for the hot water circuit, connections for
heat transfer is a prerequisite for eco- the cold water circuit and a switch cab-
nomical processes. Therefore, different inet with displays and controls. A tem-
heat exchanger types are used in prac- perature controller controls the hot wa-
tice depending on the requirements. ter temperature. The flow rate in the hot
water and cold water circuit is adjusted
This experimental unit can be used to in- using valves. The cold water circuit can
vestigate and compare different heat ex- be fed from the laboratory mains or the
changer designs. The complete experi- WL 110.20.
mental setup consists of two main ele-
ments: WL 110 as supply and control The GUNT software consists of a soft-
unit and choice of heat exchanger: Tubu- ware for data acquisition and an educa-
lar heat exchanger (WL 110.01), plate tional software. With explanatory texts
heat exchanger (WL 110.02), shell and and illustrations the educational soft-
tube heat exchanger (WL 110.03) and ware significantly aids the understanding
stirred tank with jacketed vessel and coil of the theoretical principles. With the aid
(WL 110.04). Water is used as the me- of an authoring system, the teacher can
dium. create further exercises.
G.U.N.T. Gerätebau GmbH, Hanskampring 15-17, D-22885 Barsbüttel, Telefon (040) 67 08 54-0, Fax (040) 67 08 54-42, Email sales@gunt.de, Web www.gunt.de
We reserve the right to modify our products without any notifications. Page 1/3 - 05.2018
gunt
WL 110
Heat exchanger supply unit
Specification
Technical data
Pump
• power consumption: 120W
• max. flow rate: 600L/h
• max. head: 30m
Heater
• power output: 3kW
• thermostat: 0…70°C
Measuring ranges
1 temperature controller, 2 heated tank, 3 heat exchanger (WL 110.01 to WL 110.04 ac- • temperature: 6x 0…100°C
cessories), 4 pump; red: hot water circuit, blue: cold water circuit; F flow rate, T temperat- • flow rate: 2x 20…250L/h
ure
230V, 50Hz, 1 phase
230V, 60Hz, 1 phase; 230V, 60Hz, 3 phases
UL/CSA optional
LxWxH: 1000x670x550mm
Weight: approx. 60kg
Scope of delivery
1 experimental unit
1 CD with authoring system for GUNT educational
software
1 GUNT software CD + USB cable
Software screenshot: temperature curve for WL 110.01 in parallel flow operation
1 set of instructional material
G.U.N.T. Gerätebau GmbH, Hanskampring 15-17, D-22885 Barsbüttel, Telefon (040) 67 08 54-0, Fax (040) 67 08 54-42, Email sales@gunt.de, Web www.gunt.de
We reserve the right to modify our products without any notifications. Page 2/3 - 05.2018