In this article, Satish N Diwakar outlines various aspects of solar photovoltaic (SPV) systems
on rooftops, including evaluation of existing roofs where SPV systems can be safely installed.

T
he demand for power in India generating solar power. A huge potential in India would be to install efficient
is increasing with the growing is available for generating solar power individual rooftop power-generation
population and the aspiration using the unutilized existing and new systems to minimize the dependency on
to become a developed nation. roof spaces of industrial, commercial, conventional power.
Hence, it has become necessary to explore educational, and residential buildings,
the viability of power generation using or any other type of roof spaces available SOLAR POTENTIAL IN
renewable energy sources such as solar on buildings. Solar power can be used INDIA
power since climate change is forcing partially to cater to the captive power Geographically, India falls in the bright
us to bring down the dependency on requirement of the individual facility sunny region of the world. Most parts
fossil fuels. or building and any excess power can of India receive solar radiation of
India has high solar insolation, which be fed to the grid (on-grid system). So approximately 4.7 kWh/m2/day with 300–
provides a favourable condition for the best suitable long-term solution 325 sunny days in a year. The Ministry of

December 2017–April 2018 | Akshay Urja | 32


MAXIMIZING SOLAR POWER GENERATION RE FEATURE

New and Renewable Energy (MNRE) has Battery back-up is an optional feature SPV panels needs to be provided
been facilitating different initiatives for and can be provided depending on the for movement during and after the
harnessing renewable energy in lighting, requirement where grid power supply is erection of SPV modules.
cooking, and motive power in rural expected to be intermittent. ¾¾ Roof configuration: The roof plan
areas, as well as in urban, industrial, and The roof must be able to accommodate configuration should be studied to
commercial applications. To maximize and support the components of the know its location (including longitude
the use of solar power, the ministry is SPV system safely. To achieve this, the and latitude), height, and slope, as
making all efforts in rural and urban following minimum requirements should well as any facilities already present
areas to create awareness of the benefits of be met to fetch maximum benefit. on the roof. It is also very important
solar power. However, users might have ¾¾ Desired captive power requirement: It to know the possible usage of the
apprehensions related to power output is necessary to assess the power that roof in the future, such as installation
(yield) viŚ-a-viŚ roof area availability, would be needed to meet the captive of water tank, water heater, any
strength of roof, cost of installation requirement and whether adequate equipment, or communication
(including cost of roof strengthening, if roof area is available to generate such antennae for calculating the space
any), payback period, installation and power considering the efficiencies of available for installation of SPV
maintenance, and so on. SPV modules. modules. Since India is in the
¾¾ Accessibility: The roof must be northern hemisphere, the roof surface
REQUIREMENTS: accessible to carry out installation facing south or south-east direction
ROOFTOP SOLAR and maintenance of the panels. It is preferred for maximum power
A rooftop SPV installation consists of PV should facilitate lifting and staking generation. Frame-mounted SPV
panels assembled in arrays, mounting of the solar system components onto panels facing south or south-east
frames to fix the panels on the roof, the roof and personnel to access the direction may be provided wherever
wiring, inverters, and other components work area to install and maintain roof slopes face other than south or
depending on the type of installation. the system. A walkway between south-east direction.

December 2017–April 2018 | Akshay Urja | 33


RE FEATURE

¾¾ Solar orientation and shading: It is EVALUATION OF AN additional loads due to wind acting on
preferred to have shade-free roof EXISTING ROOF FOR SPV the supporting structure of the SPV panel.
area for maximum utilization of SPV INSTALLATION In situ inspection and non-destructive
system. Roof area may get shaded due As mentioned earlier, any well- testing may also be needed in certain
to the presence of adjoining buildings maintained roof having a residual life cases to ensure structural adequacy.
or trees or any other obstruction, of at least 15 years can be considered The structural health analysis report
which may lead to lower power output for SPV installation. A structural should clearly indicate whether the roof
of the SPV system. Although shading evaluation should be carried out to is adequately strong to sustain additional
changes during the year, observing assess the strength of the roof and the loads throughout its balance life or any
the roof at different times during a roof-supporting structure to sustain structural modifications required to
day gives a fairly good idea of the additional loads (30–50 kg/m2) of the ensure the desired life. If roof space is
approximate number of sunlight SPV system. If required, necessary being leased out to a third party to install
hours and the effective roof area that repairs/replacements and strengthening solar systems, the owner should appoint
can be used for power generation. A measures should be adopted in order to an architect or a structural engineer and
sun path trajectory analysis for the achieve the required minimum strength a legal advisor who would confirm the
entire year may also be performed to and life of the roof. feasibility of considering the roof for solar
check shadow envelope. Generally, in India sloped roofs are installation from structural and statutory
¾¾ Residual life of the roof: The design life designed for live loads as per IS-875. aspects, respectively.
of an SPV system is estimated to be When part of the roof area is occupied
25 years. Any existing roof having a by SPV modules, the roof area may not SLOPING METAL ROOF
residual life of at least 15 years should experience the design live load. Since These roofs should also be inspected
be considered for SPV installation the load due to the SPV system is less to see any distress such as excessive
for reaping maximum benefit as the than the design live load, it is safe to deformations, open seams, and presence
payback period of SPV installation is assume the additional weight of SPV of water ponding due to sagging of roof
generally between 5 and 7 years. panels as part of the live load on the sheets. The roof and roof-supporting
¾¾ Aesthetics: One needs to check roof and no additional load is required structure should be inspected to check for
whether SPV modules would affect to be considered due to SPV modules. any sag and other abnormalities. A sag
the overall aesthetics of the building. However, the load-carrying capacity or depression may indicate a structural
From the road level, solar modules of roof panels should be assessed for deformation that may require further
will be more visible on a sloped roof concentrated loads due to the SPV panel investigation and rehabilitation.
than on a flat roof. One may adopt mounting frames. When evaluating the health of an
a suitable design to camouflage SPV Rooftop solar mountings should existing roof for PV installation, factors
panels on sloping roofs without resist wind pressure acting below the such as the load-carrying capacity of the
compromising the overall aesthetics of panels during cyclones. This is a critical primary and secondary members, the
the building. design consideration if the site is located type of roofing system (standing seam,
in a cyclone-prone area. The type of corrugated, or trapezoidal sheet) and
¾¾ Maintenance: Rooftop solar systems slope, the service life of the roof and the
require regular maintenance after mountings to be selected for supporting
panels must be discussed with the SPV consumed life, and wind and seismic
installation. The maintenance plan loads should be considered.
typically involves regular cleaning system supplier.
If the roof is required to be One of the primary considerations
of the solar panels, checking and is whether to install a penetrating type
tightening of connections, servicing strengthened, then the project viability
and payback period for solar installation or mechanically fastened system on the
electrical accessories in the system, existing roof. It is preferred to have a
including the inverter, and regularly should be calculated considering the
cost of strengthening the roof and the non-penetrating system. In the case of
monitoring the output of the system. standing seam roofs, the installation
The cost of maintenance will be roof-supporting structure. In the case of
extensive rehabilitation cost and longer of SPV panels would be very fast by
less in the initial period after the adopting a non-penetrating system.
installation and will increase with the payback period (more than 7 years), the
SPV installation may not be commercially With standing seam metal roofs, special
age of the system due to reduction clamps are fitted over the seam to install
in panel efficiency. The approximate viable. However, the decision to install
SPV systems on existing roofs should be the panel, thereby avoiding penetration
maintenance cost is 2% per annum of the roofing material and eliminating
of the capital cost of the system taken after proper commercial diligence.
Based on the available drawings and any possibility of leakages. Also, with
installation. the non-penetrating system, the leakage
documents, the structural health of a roof
should be determined considering the warranty of roofing manufacturers or

December 2017–April 2018 | Akshay Urja | 34


MAXIMIZING SOLAR POWER GENERATION RE FEATURE

Some of the typical installations on sloped


metal roofs are shown in Figure 1.

FLAT CONCRETE ROOF


Generally, a flat or even low-slope
concrete terrace roof will normally have
the strength to bear the additional weight
of the panels and supporting structures.
In the case of flat concrete roofs, the
primary concern is the performance
warranty of water proofing provided
over the roof. The type of water
proofing provided over the roof and
its slope needs to be examined and
recommendation should be obtained
from the waterproofing vendor on the
modifications of the existing water-
proofing system that are required to be
carried out.
pre-engineered building (PEB) vendors are still valid, check if installation of a For fixing the mounting structure of
is not compromised. rooftop solar system could nullify the the SPV module on an existing roof,
For existing low-slope roofs, it is performance warranty of the existing the water-proofing treatment only in
recommended to use non-penetrating roof. A written confirmation should be the designated area might have to be
systems to avoid leakage issues during obtained from the PEB vendor in this dismantled and redone with a similar
monsoon. If penetration is inevitable, regard before making any decisions. or better water-proofing system. A
then all the required precautions should Prior to SPV installation, all the well-designed framework of fixing
be taken while fixing the SPV panels to damaged areas should be repaired arrangement of PV modules (with or
prevent water leakage. appropriately, sheeting replaced, without water-proofing modification)
In the case of non-penetrating systems, structural member strengthened, and is preferred.
the strength of the existing roofing open seams sealed to maintain the It is often seen that utility equipment
material should be assessed by the sheet structural integrity of the roof. such as air-handling units, cooling towers,
manufacturer and clear recommendation
on whether the existing roofing material
is strong enough to withstand panel
loads should be provided. The roof
sheeting supported over purlins with
centre-to-centre distance of up to 1.5 m
is considered reasonably safe to support
SPV panels. However, a “no-objection”
certificate or a “recommendation” from
either the sheet manufacturer or the
roofing contractor needs to be obtained.
Existing sloped roofs with metal sheets, (a) (b)
tiles, or similar materials should be
examined to find whether the primary
rafters or trusses can support additional
weight as per their residual strength
available. This exercise is very important
from the point of view that many steel
buildings nowadays are PEBs, which
are designed to the given loads without
considering any margins in the loads. If
the roofing installation and performance (c) (d)
warranties offered by PEB vendors »» Figure 1 (a) Typical panel clamping detail; (b) Typical panel installation on steep slope; (c) Panels
mounted on frames; (d) Panels mounted on low sloped roof

December 2017–April 2018 | Akshay Urja | 35


RE FEATURE

(b)
(a) (c)
Figure 2 (a) Panels mounted on frames fixed directly on the roof; (b) Panel frames mounted on concrete pedestals; (c) Panels mounted on frames to get a
shade-free area for SPV
water heaters, hot water tanks, and pumps Solar cell efficiencies vary from 6% CONCLUSION
are mounted on the roof. In such cases, a for amorphous silicon-based solar The Indian government has declared its
proper study of the available area for SPV cells to 44.0% with multiple-junction solar expansion plans of targeting 100 GW
installation and yield of the SPV system production cells and 44.4% with multiple of solar capacity, including 40 GW from
should be carried out. If the required dies assembled into a hybrid package. rooftop solar, by 2022. India has witnessed
area is not adequate to meet the captive Solar cell efficiencies for commercially an exponential growth in the last 5 years.
requirement, it may not be viable to available multi-crystalline cells are around The solar-generation capacity grew from
install an SPV system. 12–16%.  2650 MW to 12,289 MW during 2014–17.
Some of the typical installations on flat The desired payback period for SPV The country added 3.01 GW of solar
roofs are shown in Figure 2. installation over an existing roof should capacity in 2015/16 and 5.525 GW in
be between 5 and 7 years considering 2016/17, the highest of any year.
CAPITAL COST AND the efficiency of panels, maintenance A rooftop SPV system connected to
PAYBACK PERIOD cost, various losses in the system, and the grid distribution system and feeding
The average shade-free roof area required cost of roof strengthening, if applicable. the power in substations or load centres
for a typical 10 kWp SPV power plant The financial viability or feasibility of the eliminates transmission and distribution
is approximately 1000 ft2 considering project is determined through the net losses. Also with grid-connected systems,
15% panel efficiency. Table 1 gives a fair present value method. the cost of batteries for storing power
idea about the area required and desired is eliminated. These are the strong
power for different panel efficiencies. TRENDS AND reasons for promoting grid-interactive
DEVELOPMENTS IN rooftop SPV systems for captive power
Table 1: Roof area required for different SPV SYSTEM AND generation.
power outputs APPLICATIONS Although SPV systems are being
Desired 1 kW 2 kW 5 kW 10 kW In the last 5 to 7 years, the solar industry installed on the roofs of newer
power has undergone a sea change in the constructions, a large potential is
Panel Roof area required in square quality of SPV systems and the type of available for generating solar power using
efficiency feet applications to meet the challenging unutilized roof spaces. It is now attractive
12% 125 250 625 1250 demands of sustenance. Some of the latest and economical to install SPV systems
13% 115 230 550 1150 developments in SPV panels include over existing roofs considering the on-
frameless solar panels, clear (glass) solar grid system promoted by DISCOMS.
14% 107 214 536 1071
panels, double-sided solar panels, and so While roof is a convenient and suitable
15% 100 200 500 1000
on. The newer constructions in residential place for installing solar panels, a right
16% 94 188 469 938 approach is necessary for ensuring that
and industrial sectors have already
The estimated cost of an on-grid 1 kWp commenced installing these SPV systems the serviceability performance of the roof
rooftop SPV plant would be `0.9–1.1 lakh on the roofs. and the warranty offered by contractors
(without considering any subsidy and In addition to rooftop or ground- for water tightness remain unaffected.
incentive). Similarly, a 1 kWp off-grid mounted solar plants, different solar Roof spaces can also be leased out
system with minimum battery back-up applications such as floating solar plants, (roof leasing) for generating solar power
should require `1.2–1.7 lakh (without solar installations over water canals, either for captive requirement or for
considering any subsidy and incentive) solar trees, and solar roadways are being transmitting back to the grid.
approximately. The above costs would experimented or piloted, which could
further reduce if subsidies and incentives transform the solar industry. Mr Satish N Diwakar, Senior General Manager—
Civil (Discipline Head), Tata Consulting
are considered. Engineers Limited.