Guideline for
Approval of
Electrical
E N E R G Y
Equipment
(ELECTRICITY REGULATIONS 1994)
G P / ST / N O . 1 4 / 2 0 1 7
1 G U I D E L I N E F O R A P P R OVA L O F E L E C T R I C A L E Q U I P M E N T
SIXTH EDITION [2018]
Published by :
SURUHANJAYA TENAGA (ENERGY COMMISSION)
NO. 12, Jalan Tun Hussein, Precinct 2, 62100 Putrajaya, Malaysia
Tel : (603) 8870 8500
Fax : (603) 8888 8637
Toll Free Number : 1-800-2222-78 (ST)
www.st.gov.my
ISBN : 978-967-2085-06-5
ST Publication Number : ST(P)13/11/2018
PRINTED IN MALAYSIA
G P / ST / N O . 1 4 / 2 0 1 7
22 G U I D E L I N E F O R A P P R OVA L O F E L E C T R I C A L E Q U I P M E N T
C O M M I S S I O N
E N E R G Y
G P / ST / N O . 1 4 / 2 0 1 7
3 G U I D E L I N E F O R A P P R OVA L O F E L E C T R I C A L E Q U I P M E N T
ELECTRICITY SUPPLY ACT 1990
[ACT 447]
IN exercise of the power conferred by Section 50c of the Electricity Supply Act
1990 [Act 447], the Comission issues the following guideline:
Interpretation
3. In this Guideline, unless the context otherwise requires -
Act mean the Electricity Supply Act 1990 [Act 447], Electricity Supply
(Amendment) Act 2015 [Act A1501] and its subsequent amendment,
if any.
G P / ST / N O . 1 4 / 2 0 1 7
44 G U I D E L I N E F O R A P P R OVA L O F E L E C T R I C A L E Q U I P M E N T
iii. Certificate of Approval (CoA) to import, manufacture,
display, sell or advertise regulated electrical equipment,
iv. Renewal of Certificate of Approval (CoA) to import,
manufacture, display, sell or advertise regulated electrical
equipment,
v. Certificate of Approval (CoA) for Exhibition purposes,
vi. Release Letter for CoA Exemption,
vii. Release Letter for Non-Regulated Item,
viii. Import Electrical Equipment for Personal Use;
• national deviation;
• energy efficiency; and
C O M M I S S I O N
• labelling requirements.
E N E R G Y
Notice by the Commission
6. The Commission may issue written notices from time to time in relation
to this Guideline.
G P / ST / N O . 1 4 / 2 0 1 7
5 G U I D E L I N E F O R A P P R OVA L O F E L E C T R I C A L E Q U I P M E N T
C O N T E N T S
CHAPTER Page
Preface 07
1 Introduction 09
2 Who Should be Concerned with this Booklet 11
3 Key Regulations to Note 13
4 Parties that Need to Apply for Certificate of Approval (CoA) 27
5 List of Regulated Electrical Equipment 29
5a. Requirements for Manufacturers & Importers
to Comply with Minimum Energy Performance
Standards (MEPS) 47
6 Application for Certificate of Approval for Electrical Equipment 51
6.1 New Application for CoA (Import/Manufacturer) 52
6.2 Renewal Application for CoA (Import/Manufacturer) 55
6.3 Application for CoA for Exhibition Purposes 57
7 Application for Release Letter (RL) 60
8 Regulatory Requirements Related to National Differences 62
9 Labelling or Certification Mark 69
APPENDIXES
A Application for Certificate of Registration (CoR)
to Manufacture/Import 77
B Application for New CoA 79
C Application for Renewal of CoA 82
D Application for CoA for Exhibition 85
E Application for Release Letter (RL) on Electrical Equipment 87
F Sample of Certificate of Registration
to Manufacturer/Importer as Form V1 90
G Sample of CoA for importer (new, renewal or exhibitor)
as Form V 92
H Sample of CoA for manufacturer (new or renewal) as Form W 94
I Sample of CoR as Conformity Assessment Body as Form U1 96
J Acceptable and Non-acceptable 2-pin Mains Plug 98
G P / ST / N O . 1 4 / 2 0 1 7
66 G U I D E L I N E F O R A P P R OVA L O F E L E C T R I C A L E Q U I P M E N T
PREFACE
This Information Booklet serves as a guide on the procedure of applying for the
Certificate of Approval (CoA) to manufacture, import, display, sell or advertise
any electrical equipment prescribed under sub regulation 97(1) of the Electricity
Regulations 1994 and other related regulatory requirements therein. It can be
downloaded from the website www.st.gov.my.
The Energy Commission (the Commission) expressly disclaim all liability to any
person in respect of any statement in or omission from this Information Booklet
to the extent permitted by the law and nothing contained in this Information
Booklet should be taken as constituting any amendment to the Electricity
C O M M I S S I O N
Supply Act 1990 [Act 447] or the Electricity Regulations 1994. In the event
of any conflict, Act 447 or the Regulations shall at all times take precedence.
This Information Booklet should not, therefore be regarded as or substitute
for familiarising yourself with Act 447 or the Regulations, or where necessary,
obtaining specific advice for your individual position.
E N E R G Y
The Commission reserves the right to amend and introduce new requirements
to the aforementioned procedures of obtaining a CoA.
www.st.gov.my
G P / ST / N O . 1 4 / 2 0 1 7
7 G U I D E L I N E F O R A P P R OVA L O F E L E C T R I C A L E Q U I P M E N T
C HAPTER 1
G P / ST / N O . 1 4 / 2 0 1 7
8 G U I D E L I N E F O R A P P R OVA L O F E L E C T R I C A L E Q U I P M E N T
INTRODUCTION
Why CoA is required?
The objective for the issuance of CoA under the Electricity Regulations 1994 is to
ensure that all activities to manufacture, import, display, sale or advertisement
of:
C O M M I S S I O N
meets the specified safety and efficient use of electricity requirements.
E N E R G Y
(b) complying to standards;
(c) tested by accredited laboratory;
(d) labelled with SIRIM-ST’s label.
G P / ST / N O . 1 4 / 2 0 1 7
9 G U I D E L I N E F O R A P P R OVA L O F E L E C T R I C A L E Q U I P M E N T
C HAPTER 2
10 .
G P / PSTA/ NGO .E1 4 / 2 0E1 7N E R G Y C O M M I S S I O N
10 G U I D E L I N E F O R A P P R OVA L O F E L E C T R I C A L E Q U I P M E N T
WHO SHOULD BE CONCERNED WITH
THIS BOOKLET
Consumers
In line with the safety requirements as well as to safeguard consumer’s interests
and to ensure the efficient use of electricity, consumers should only purchase:
C O M M I S S I O N
which have been approved by the Commission and affixed with a predetermined
label.
E N E R G Y
This Information Booklet is to assist manufacturers, importers, exhibitors, sellers
and advertisers in understanding and fulfilling the requirements and procedures
for obtaining the CoA and other related regulatory requirements determined by
the Energy Commission.
G P / ST / N O . 1 4 / 2 0 1 7
11 G U I D E L I N E F O R A P P R OVA L O F E L E C T R I C A L E Q U I P M E N T
C HAPTER 3
G P / ST / N O . 1 4 / 2 0 1 7
12 G U I D E L I N E F O R A P P R OVA L O F E L E C T R I C A L E Q U I P M E N T
KEY REGULATIONS TO NOTE
Reference to Electricity Regulations 1994;
C O M M I S S I O N
Recognition of foreign conformity assessment body
Regulation 97(A) (1) For the purposes of certifying any equipment under
regulation 97, the Commission shall give a recognition
to a foreign conformity assessment body, in a manner
that may be determined by the Commission.Provided
that, the foreign conformity assessment body shall
be recognised, registered or licensed by the relevant
E N E R G Y
authority in the country in which the foreign conformity
assessment body carries on its business.
G P / ST / N O . 1 4 / 2 0 1 7
13 G U I D E L I N E F O R A P P R OVA L O F E L E C T R I C A L E Q U I P M E N T
Registration of local conformity assessment body
Regulation 97 (B) (1) For the purposes of certifying any equipment under
regulation 97, a local conformity assessment body
shall apply to be registered with the Commission, in a
manner that may be determined by the Commission.
G P / ST / N O . 1 4 / 2 0 1 7
14 G U I D E L I N E F O R A P P R OVA L O F E L E C T R I C A L E Q U I P M E N T
Submission of test report or Certificate of Conformity by manufacturer
Regulation 97 (D) (1)
Any manufacturer issued with a Certificate of
Registration under regulation 97C shall submit to the
Commission-
a. a test report as to the equipment’s conformity
with the safety standards as recognised by the
Commission; or
C O M M I S S I O N
date of the report.
E N E R G Y
as the case may be, the manufacturer shall submit a
new test report or Certificate of Conformity to the
Commission in accordance with this regulation
G P / ST / N O . 1 4 / 2 0 1 7
15 G U I D E L I N E F O R A P P R OVA L O F E L E C T R I C A L E Q U I P M E N T
(2) A test report under subregulation (1) shall be issued by
a testing laboratory recognised by the Commission and
the report shall be valid for not less than one year and
not exceeding five years from the date of the report.
(3)
A Certificate of Conformity under subregulation
(1) shall be valid for not less than one year and not
exceeding three years from the date of the certificate.
G P / ST / N O . 1 4 / 2 0 1 7
16 G U I D E L I N E F O R A P P R OVA L O F E L E C T R I C A L E Q U I P M E N T
Marking or labelling of approved equipment
Regulation 98 Where an equipment has been approved for
manufacture, import, display, sale or advertisement by
the Commission, the person to whom a Certificate of
Approval has been issued under regulation 97 may be
required by the Commission to mark or
label the equipment and he shall do so in the
manner to be determined by the Commission.
C O M M I S S I O N
(2) The applicant shall deliver to the Commission samples
of the equipment in sub regulation (1) and such
other information in connection therewith, including
drawings, photographs, pamphlets and technical
literature, as the Commission may require.
(3) A sample delivered shall have attached or affixed
E N E R G Y
thereto a label bearing the following particulars:
a. the full name of the applicant;
b. the nature of the equipment;
c. the energy efficiency of the equipment; and
d. the catalogue or type number of the manufacturer,
or any other means of identifying the equipment
G P / ST / N O . 1 4 / 2 0 1 7
18 G U I D E L I N E F O R A P P R OVA L O F E L E C T R I C A L E Q U I P M E N T
Energy performance testing report
Regulation 101B (1) An energy performance testing report under sub
regulation 101A(2) shall be submitted to the
Commission, in a manner that may be determined by
the Commission.
C O M M I S S I O N
(4) A manufacturer or an importer who submits an energy
performance testing report under this regulation shall
ensure that such test report has a validity period of not
less than one year before the expiry date.
Submission for test and seizure for the purpose of efficient use of electricity
E N E R G Y
Regulation 101C (1) The Commission may, at any time, by notice in writing,
require any person who manufactures, imports, sells
or offers for sale or lease such equipment as referred
to in regulation 101A, to deliver, within such period
as may be specified in the notice, samples of the
equipment for an examination and a test.
G P / ST / N O . 1 4 / 2 0 1 7
19 G U I D E L I N E F O R A P P R OVA L O F E L E C T R I C A L E Q U I P M E N T
(3) The Commission shall not be liable for any loss or
damage caused in the delivery or seizure and removal
of equipment under sub regulation (1) or (2), as the
case may be.
G P / ST / N O . 1 4 / 2 0 1 7
20 G U I D E L I N E F O R A P P R OVA L O F E L E C T R I C A L E Q U I P M E N T
(2) Where a Certificate of Registration is cancelled by
the Commission pursuant to sub regulation (1), the
Certificate shall be returned to the Commission by the
person, to whom the Certificate was issued, within
fourteen days of the person being notified in writing of
the cancellation.
C O M M I S S I O N
cancelled under regulation 104.
E N E R G Y
may register him again.
Renewal of CoA
Regulation 106 Renewal of a Certificate of Approval issued under regulation
97 shall be made not less than 14 days before the date of expiry
of the Certificate.
G P / ST / N O . 1 4 / 2 0 1 7
21 G U I D E L I N E F O R A P P R OVA L O F E L E C T R I C A L E Q U I P M E N T
Transfer of CoA
Regulation 107 (1) No Certificate of Approval issued under regulation 97,
shall be transferred by the holder of the Certificate to
any other person except with the written permission of
the Commission.
(2)
The holder of a Certificate of Approval issued
under regulation 97, shall obtain approval from the
Commission in writing for any change of name or
address in connection with the business and the
Certificate shall be amended or replaced without
payment of any fee.
Cancellation of CoA
Regulation 108 (1) The Commission may cancel a Certificate of Approval
issued in respect of any equipment referred to in
regulation 97 if-
a. the equipment is found to be unsafe for use upon
any examination or test thereof;
b. the person to whom the Certificate was issued,
uses it for a purpose different from that for which
it was issued or in a manner calculated to mislead
or deceive the public;
c. the person has contravened or failed to comply
with any of the provisions of the Act or these
Regulations; or
d. the holder of the Certificate has obtained the
Certificate by making or causing to be made any
false or fraudulent declaration, certification or
representation, either in writing or otherwise
G P / ST / N O . 1 4 / 2 0 1 7
22 G U I D E L I N E F O R A P P R OVA L O F E L E C T R I C A L E Q U I P M E N T
Removal from and Reinstatement Approval to the Register of CoA
Regulation 109 (1) There shall be removed from the Register the name and
other particulars or any person whose Certificate of
Approval was issued under regulation 97-
a. where he has failed to renew his Certificate of
Approval by the date of expiry thereof; or
b. where his Certificate of Approval has been cancelled
under regulation 108.
C O M M I S S I O N
(3) The person referred to in sub regulation (2) who feels
aggrieved by the decision of the Commission not to
reinstate him, may apply to the Minister for
re-consideration of the matter.
E N E R G Y
in writing within twenty-one days from the date of
the decision of the Commission and shall contain the
grounds of grievance.
Market surveillance
Regulation 109A (1) The Commission may, from time to time, carry out
market surveillance to determine if any equipment
referred to in regulation 97 is safe and is affixed with a
label in accordance with regulation 98 or an efficiency
rating label, or both, as the case may be.
G P / ST / N O . 1 4 / 2 0 1 7
23 G U I D E L I N E F O R A P P R OVA L O F E L E C T R I C A L E Q U I P M E N T
(2) Whoever, intentionally or knowingly-
a. removes, withdraws or assists in the removal or
withdrawalof any equipment, which is not labelled
in accordance with regulation 98 or which does not
bear an efficiency rating label, or both, as the case
may be, from any premises in order to obstruct or
hinder the Commission, its authorised officers or
agents from exercising any of its powers; or
b. harbours, keeps, conceals, or is in the possession of
any equipment which is not labelled in accordance
with regulation 98 or which does not bear an
efficiency rating label, or both, as the case may be,
with the intention to sell or offer for sale, Commits
an offence.
G P / ST / N O . 1 4 / 2 0 1 7
24 G U I D E L I N E F O R A P P R OVA L O F E L E C T R I C A L E Q U I P M E N T
Offences and Penalty
Section 37(1), Any person who tampers with or adjusts any installation
Electricity Supply or part thereof or manufactures or imports or sells any
(Amendment) Act equipment so as to cause or to be likely to cause danger
2015 to human life or limb or injury to any equipment or other
property shall be guilty of an offence and for each such
offence shall, on conviction, be liable to a fine not exceeding
RM1,000,000 or to imprisonment for a term not exceeding
10 years or to both.
C O M M I S S I O N
year or to both.
E N E R G Y
G P / ST / N O . 1 4 / 2 0 1 7
25 G U I D E L I N E F O R A P P R OVA L O F E L E C T R I C A L E Q U I P M E N T
C HAPTER 4
G P / ST / N O . 1 4 / 2 0 1 7
26 G U I D E L I N E F O R A P P R OVA L O F E L E C T R I C A L E Q U I P M E N T
PARTIES THAT NEED TO APPLY FOR
CERTIFICATE OF APPROVAL (CoA)
Importers
Importers of electrical equipment under sub regulation 97(1) of the Electricity
Regulations 1994 are required to apply for the CoA from the Commission.
An importer shall be a Malaysian company registered with the Companies
Commission of Malaysia.
Manufacturers
Manufacturers who manufacture electrical equipment under regulation 97(1)
of the Electricity Regulations 1994 are required to apply for the CoA.
C O M M I S S I O N
Exhibitors
Exhibitors who display electrical equipment under sub regulation 97(1) of the
Electricity Regulations 1994 are also required to apply for the CoA.
E N E R G Y
CoA and to ensure that the electrical equipment to be sold or advertised are in
accordance with sub regulation 97(1), 97(2) and 98 of the Electricity Regulations
1994.
G P / ST / N O . 1 4 / 2 0 1 7
27 G U I D E L I N E F O R A P P R OVA L O F E L E C T R I C A L E Q U I P M E N T
C HAPTER 5
G P / ST / N O . 1 4 / 2 0 1 7
28 G U I D E L I N E F O R A P P R OVA L O F E L E C T R I C A L E Q U I P M E N T
LIST OF REGULATED ELECTRICAL EQUIPMENT
Note: Regulated Electrical Equipment are to be tested to the specified standards.
Equipment that are tested and certified to the same standards of later revisions are also acceptable.
C O M M I S S I O N
• has a maximum rating international standard
of 15 A;
(b) Coupler Appliance Coupler MS IEC 60320- IEC 60320-1:2007
• is for attachment to a 1:2010
flexible cord; and
• makes a detachable
connection between
the conductors of the
cord and the pins or Interconnection MS IEC 60320- IEC 60320-1:2007
contacts of any low Coupler 1:2010
E N E R G Y
voltage appliance or MS IEC 60320- IEC 60320-2-2: 1998
equipment of a type 2-2:2011 (con-
intended or generally firmed 2015)
used for household
applications
(c) Adaptor Adaptor MS 589-3:2018 BS 1363 PT.3:1995
• extends supply from a (Multiways) +A1, A2, A3
socket-outlet;
• incorporates one or Integrated Adaptor MS 1144:2017 BS 5733:2010+A1
more integral 2014
socket-outlets; and
• has insulating sleeves Travel Adaptor No corresponding IEC 60884-1:2006
on the line and MS
neutral plug pins. No corresponding IEC 60884-2-5:1995
MS
G P / ST / N O . 1 4 / 2 0 1 7
29 G U I D E L I N E F O R A P P R OVA L O F E L E C T R I C A L E Q U I P M E N T
No Category Description of Detail of Standards
Regulated Equipment Equipment
National Equivalent
Standard International
Standard
Connecting MS IEC 60998- IEC 60998-1:2002
device with 1:2005
insulation-piercing MS IEC 60998-2- IEC 60998-2-3:2002
clamping units 3:2005
G P / ST / N O . 1 4 / 2 0 1 7
30 G U I D E L I N E F O R A P P R OVA L O F E L E C T R I C A L E Q U I P M E N T
(b) Portable Portable cable reel MS 1141: 2006 IEC 61242: 2008
• A device with modification
comprising a
flexible cable or cord
attached to a reel so
constructed that the
flexible cable may be
completely wound
onto the reel, and
provided with a plug
and one or more
socket outlets.
4 FLUORESCENT (a) Lamp Holder Lamp holder for MS IEC 60400: IEC 60400: 2004
LAMPHOLDER Holds tubular tubular fluorescent 2006
/ STARTER fluorescent lamp but lamp
HOLDER does not include:
A lamp holder
which by design is
restricted to specific
appliances.
C O M M I S S I O N
(b) Starter Holder Starter holder for MS IEC 60400: IEC 60400: 2004
to hold a glow tubular fluorescent 2006
starter lamp
E N E R G Y
5 CEILING ROSE • a terminal for Ceiling Rose MS 770:1982 BS 67:1969
connection to a (confirmed 2006)
lamp holder via a
cable.
• Edison Screw Lamp Edison Screw Lamp MS IEC IEC 60238:2004
holder with Edison holder 60238:2008
screw thread E14,
E27 and E40,
designed for holding
and connecting to
the supply of lamps.
6 BAYONET • holds a bayonet cap Bayonet cap Lamp No IEC
CAP and lamp, bayonet cap holder corresponding 61184:2008+A1
MULTIWAYS adaptor MS
ADAPTOR but does not include:
• a lamp holder, Bayonet Lamp MS 769:1982 IEC 61184:2008
which by design, is Adaptor (confirmed 2013) with modification
restricted to specific with IEC
appliances 61184:2008
• a lamp holder which
is for incorporation
in an industrial
equipment
G P / ST / N O . 1 4 / 2 0 1 7
31 G U I D E L I N E F O R A P P R OVA L O F E L E C T R I C A L E Q U I P M E N T
No Category Description of Detail of Standards
Regulated Equipment Equipment
National Equivalent
Standard International
Standard
7 LAMP (a) Luminaires Fixed general MS IEC 60598- IEC 60598-1:2008
FITTING • provides illumination; purpose Luminaires 1:2012
• incorporate electric (excluding Tube/ MS IEC 60598-2- IEC 60598-2-1:1979
light sources for Bulb), 1:1997
operation from supply Batten Luminaires (confirmed 2015)
voltage up to 1000V. (excluding Tube/
Bulb),
Luminaires with
self-ballasted
fluorescent lamp
Recessed MS IEC 60598- IEC 60598-1:2008
Luminaires 1:2012
(excluding Tube/ MS IEC 60598-2- IEC 60598-2-2:1997
Bulb) 2:1998
(confirmed 2011)
(b) Glow Starter Glow-starter for MS IEC 60155: IEC 60155:2006
• is for starting preheat tubular fluorescent 1996
type fluorescent
lamps;
• is a glow-start type;
and
• has an enclosure of
insulating material
• holds a light source or
bulb.
G P / ST / N O . 1 4 / 2 0 1 7
32 G U I D E L I N E F O R A P P R OVA L O F E L E C T R I C A L E Q U I P M E N T
(d) LED Lighting Lamp control gear: MS IEC IEC 61347-1:2010
Particular require- 61347-1:2012
ments for dc or ac MS IEC IEC 61347-2-
supply electronic 61347-2- 13:2006
control gear for LED 13:2012
modules
Lamp holder MS IEC IEC 60838-1:2004
(Connectors for 60838-1:2008
LED-modules) MS IEC IEC 60838-2-2:2006
60838-2-
2:2008
Self-ballasted LED MS IEC IEC
Modules for general 62031:2011 62031:2008+A1,
Lighting services by with MS IEC A2 with
voltage > 50V 60061-1:2005 IEC 60061-1:2005
Self-ballasted MS IEC IEC 62776:2014
double capped LED 62776:2017
Lamps for general
lighting services by
voltage > 50V
C O M M I S S I O N
(to retrofit linear
fluorescent lamp)
Self-ballasted single MS IEC IEC 62560:2011
capped LED-lamps 62560:2012
for general lighting
services by voltage
> 50V
8 CAPACITOR • is used together with Capacitors for use in MS IEC IEC 61048: 1999
E N E R G Y
for a ballast in a lamp tubular fluorescent 61048: 2006
FLUORESCENT circuit. lamps and other MS IEC IEC 61049: 1991
LAMP circuits. 61049: 1999
(confirmed
2015)
9 BALLAST / (a) Ballast Magnetic Ballast for MS IEC IEC 61347-1: 2010
CONTROL • is for controlling the tabular fluorescent 61347-1:
GEAR / magnitude of current lamp 2012
DRIVER FOR flowing through the MS IEC IEC 61347-2-8:
61347-2- 2000
LAMP discharge path of a 8:2003
fluorescent lamp, MS 141:2014 IEC 60921:2006
• is of the independent with MS IEC with modification
or built-in type 60921:2013
intended for use with
luminaires (portable Electronic Ballast for MS IEC IEC 61347-1:2010
or fixed); or fluorescent lamp 61347-1:2012
• is of the integral type MS IEC IEC 61347-2-3:2000
61347-2-
such that it forms a 3:2003
non-replaceable part MS IEC IEC 60929:2006
of a fluorescent lamp/ 60929: 2008 with IEC 61000-3-2:
ballast combination; with 2009
or MS IEC
• is of the adaptor type 61000-3-2:
such that it allows 2014
the insertion of a
fluorescent lamp into
the ballast by the
user;
G P / ST / N O . 1 4 / 2 0 1 7
33 G U I D E L I N E F O R A P P R OVA L O F E L E C T R I C A L E Q U I P M E N T
No Category Description of Detail of Standards
Regulated Equipment Equipment
National Equivalent
Standard International
Standard
but does not include :
• a ballast which is
incorporated in
luminaires certified
for compliance with
the requirements for
electrical equipment
with increased
safety type protection
(Explosive) for use in
hazardous locations.
(b) Control Gear Control Gear MS IEC 61347- IEC 61347-1:2010
• General safety 1:2012
for lamp control
gear for use on dc
supply up to 250V
and or ac supply up
to 1000 V
10 CIRCUIT (a) Residual Current Residual Current MS IEC 61008-1: IEC 61008-1: 2010
BREAKER Device (RCD) Circuit Breaker 2012
including AC • isolates or initiates (RCCB) MS IEC 61008-2- IEC 61008-2-1:
CURRENT a tripping signal to 1: 2003 1990
OPERATED isolate a low- or or
EARTH voltage supply to MS IEC 61008-1: IEC 61008-1: 2010
LEAKAGE protected circuits, 2012
CIRCUIT socket-outlets or MS IEC 61008-2- IEC 61008-2-2:
BREAKER equipment in the 2: 2003 1990
and event of a current
Residual Current MS IEC 61009-1: IEC 61009-1: 2010
MINIATURE flow to earth which
Breaker with 2012
CIRCUIT exceeds a pre-
Overcurrent MS IEC 61009-2- IEC 61009-2-1:
BREAKER determined level;
Protection (RCBO) 1: 2003 1991
• has a rated residual
or or
current less than
MS IEC 61009-1: IEC 61009-1: 2010
300mA for devices
2012
intended for
MS IEC 61009-2- IEC 61009-2-2:
connection to fixed
2: 2003 1991
wiring or 10mA for
other devices; and
• has a rated load
current not
exceeding 125 A
for devices
intended for
connection to fixed
wiring or 20 A for
other devices.
G P / ST / N O . 1 4 / 2 0 1 7
34 G U I D E L I N E F O R A P P R OVA L O F E L E C T R I C A L E Q U I P M E N T
but does not include :-
• a device intended to be
used with a particular
circuit-breaker other
than a miniature over-
current circuit-breaker;
or
• a device intended to
protect an electricity
supply authority
distribution system.
(b) Fuse Miniature MS IEC 60898-1: IEC 60898-1: 2003
• is an enclosed air- Circuit Breaker 2007
break switch; (MCB) for ac
• opens a low voltage supply
circuit automatically
under pre-determined
conditions of Miniature MS IEC 60898-2: IEC 60898-2: 2003
over-current; Circuit Breaker 2007
C O M M I S S I O N
• has a nominal rating (MCB) for ac &
not exceeding 125 dc supply
A and has a current
breaking capacity of up
to 10kA. Fuse Base & MS IEC 60269- IEC 60269-1:2006
• is by the fusion of one Carrier up to 1:2011
or more of its specially 32A MS IEC 60296- IEC 60269-2:2006
designed and 2:2011
proportioned
E N E R G Y
components, opens
the circuit in which it Fuse/Fuse Link MS IEC 60269- IEC 60269-2:2006
is inserted and breaks up to 63A 2:2011
the current when this MS IEC 60269- IEC 60269-3:2010
exceeds a given value 3:2011
for a sufficient time.
The fuse comprises all Switch fuse up MS IEC 60947- IEC 60947-1:2007
the parts that form the to 63A. 1:2010
complete device. MS IEC 60947- IEC 60947-3:2008
3:2010
11 PORTABLE • is a household type; Standing Lamp MS IEC 60598-1: IEC 60598-1:2008
LUMINAIRE • provides illumination with detachable 2012
LAMP or for decorative or non-detachable MS IEC 60598-2-4: IEC 60598-2-4:
purposes, produces mains supply 2003 (confirmed 1997
light; flexible cord, 2015)
• is fitted with a
supply flexible cord, an Standing Lamp
appliance inlet socket & adaptor,
or a power supply unit
with integral pins for Table lamp with
insertion into a socket detachable or
outlet; non-detachable
• is for standing on a mains supply
table or floor, or is flexible cord,
fitted with a clamp or
similar for attachment Table Lamp &
to vertical or horizontal adaptor,
surfaces;
G P / ST / N O . 1 4 / 2 0 1 7
35 G U I D E L I N E F O R A P P R OVA L O F E L E C T R I C A L E Q U I P M E N T
No Category Description of Detail of Standards
Regulated Equipment Equipment
National Equivalent
Standard International
Standard
• is for use with tung- Portable LED Lamp
sten filament, tubular
fluorescent or other
discharge lamps; and Night Lamp MS IEC 60598- IEC 60598-1:2008
• is constructed to integral with direct 1:2012
represent a model, in plug. MS IEC 60598-2- IEC 60598-2-12:2006
person or animal and 12:2010
is likely to be treated
Hand Lamp & MS IEC 60598-1: IEC 60598-1:2008
by a child as a toy; or
adaptor, 2012
• has metal parts which
MS IEC 60598-2- IEC 60598-2-8:2007
are required to be
8:2006
earthed or double
insulated from live
parts (excluding live
parts of an all
insulated lamp
holder)
• is for inspection
purposes using
illumination;
• holds a light source or
bulb; and
• is hand held;
G P / ST / N O . 1 4 / 2 0 1 7
36 G U I D E L I N E F O R A P P R OVA L O F E L E C T R I C A L E Q U I P M E N T
Multi-purpose MS IEC 60335-1: IEC 60335-1: 2010
cooker 2015
MS IEC 60335-2- IEC 60335-2-9:2008
9:2014
MS IEC 60335-2- IEC 60335-2-13:2004
13:2006
MS IEC 60335-2- IEC 60335-2-15:2002
15:2004
Water Dispenser MS IEC 60335-1: IEC 60335-1: 2010
-Filter/Ionizer/ 2015
Hydrogen
Water Dispenser MS IEC 60335-1: IEC 60335-1: 2010
- Hot 2015
MS IEC 60335-2- IEC 60335-2-15:2002
15:2004
Water Dispenser MS IEC 60335-1: IEC 60335-1:2010
- Cold 2015
MS 1597-2-24:2005 IEC 60335-2-24:2010
C O M M I S S I O N
Water Dispenser MS IEC 60335-1: IEC 60335-1:2010
– Hot and Cold 2015
(If the hot water MS 1597-2-24:2005 IEC 60335-2-15:2002
boils) (confirmed 2013)
MS IEC 60335-2- IEC 60335-2-24:2005
15:2004
E N E R G Y
(if the hot water MS 1597-2-24:2005 IEC 60335-2-24:2002
does not boils) (confirmed 2013)
MS 1597-2-21:2015 IEC 60335-2-21:2012
with modification
G P / ST / N O . 1 4 / 2 0 1 7
37 G U I D E L I N E F O R A P P R OVA L O F E L E C T R I C A L E Q U I P M E N T
No Category Description of Detail of Standards
Regulated Equipment Equipment
National Equivalent
Standard International
Standard
14 TOASTER / • is a household Stationary type:- MS IEC 60335- IEC 60335-1:2010
OVEN (Cooking type; and Electric Oven, 1:2015
Appliance) • is for toasting bread Induction Hob, MS IEC 60335-2- IEC 60335-2-6:2008
or similar food; Induction 6:2014
• is for cooking or Cooker,
warming food by Cooking Range,
electrical energy; Grill.
• applies heat to
Portable type:- MS IEC 60335- IEC 60335-1:2010
food, liquid or other
Bread Maker, 1:2015
substances in a
Bread Toaster, MS IEC 60335-2- IEC 60335-2-9:2008
chamber by means
Portable Oven, 9:2014
of high-frequency
Induction
electromagnetic
Cooker,
radiation.
Grill,
Sandwich
Maker, Waffle
Maker,
Roaster,
Barbeque,
Pop-corn maker.
• a type, promoted
exclusively to
industry/commercial
sector.
• a type, promoted
exclusively to
industry/commercial
sector.
G P / ST / N O . 1 4 / 2 0 1 7
38 G U I D E L I N E F O R A P P R OVA L O F E L E C T R I C A L E Q U I P M E N T
17 IMMERSION • is a household type; Fixed Immersion MS IEC 60335- IEC 60335-1:2010
WATER • is for heating liquid Heater 1:2015
HEATER in which it may be MS IEC 60335-2- IEC 60335-2-
immersed; and 73:2014 73:2009
• is self contained;
and includes –
Portable MS IEC 60335- IEC 60335-1:2010
• aquarium type Immersion Heater 1:2015
immesion heaters MS IEC 60335-2- IEC 60335-2-
74:2010 74:2006
C O M M I S S I O N
than 680 L.
(b) Instantaneous Instantaneous MS IEC 60335-1: IEC 60335-1:2010
• is for heating water; Water Heater 2015
• is of the MS 1597-2- IEC 60335-2-35:2006
instantaneous type; 35:2010 with modification
and
• incorporates live parts
in contact with water.
19 WASHING • is a household type; Washing Machine MS IEC 60335- IEC 60335-1:2010
E N E R G Y
MACHINE and with dryer 1:2015
• is used for washing/ MS IEC 60335-2- IEC 60335-2-7:2006
drying clothes. 7:2007
• household type; Dish Washer and MS IEC 60335-1: IEC 60335-1: 2010
• for washing and other utensils. 2015
rising dishes. MS 1597- 2-5:2005 IEC 60335-2-5:2005
with modification
G P / ST / N O . 1 4 / 2 0 1 7
39 G U I D E L I N E F O R A P P R OVA L O F E L E C T R I C A L E Q U I P M E N T
No Category Description of Detail of Standards
Regulated Equipment Equipment
National Equivalent
Standard International
Standard
20 FAN • is a household type; Moving-louver fan, MS IEC 60335-1: IEC 60335-1:2010
• has a primary function Ceiling fan, 2015
of moving air in its Auto fan, MS 1597- IEC 60335-2-80:2008
vicinity; and Pedestal fan, 2-80:2010 with modification for
• is self contained; Table fan, ceiling fan only
Wall fan & MS 1220:2010 IEC 60879:1986 with
applies to their modification
separate regulators
and with blade.
G P / ST / N O . 1 4 / 2 0 1 7
40 G U I D E L I N E F O R A P P R OVA L O F E L E C T R I C A L E Q U I P M E N T
23 SHAVER • is a household type; Shaver, Hair MS IEC 60335-1: IEC 60335-1: 2010
and Clippers. 2015
• shaves, cuts or trims MS IEC 60335- IEC 60335-2-
human hair. 2-8:2002 (con- 8:1992+A1
firmed 2013)
24 VAPORISER • is a household type; Mosquito Matt MS IEC 60335- IEC 60335-1:2010
and Vapour, 1:2015
• Purpose as air (eg. Air Freshener, MS IEC 60335-2- IEC 60335-2-
fresheners and insect Insect repeller). 101:2014 101:2008
repellers.
25 VACUUM • is a household type; Vacuum Cleaner, MS IEC 60335-1: IEC 60335-1: 2010
CLEANER • is portable; and 2015
• removes dust, dirt or Water Suction MS IEC 60335-2- IEC 60335-2-2:2004
moisture and the like Cleaning. 2:2006
from floor coverings by
suction; or
C O M M I S S I O N
• removes garden refuse
from lawns or paths
and the like by suction.
• a type, promoted
exclusively to industry/
commercial sectors.
E N E R G Y
26 HI-FIDELITY • is a household type; Sub-woofer, MS IEC 60065: IEC 60065: 2005
SET • is for reproduction Amplifier, 2007 or
of sound, with little Cassette Player, IEC 62368-1:2014
distortion, connected Equalizer/Mixer,
to the supply mains as Hi-Fi System,
the only energy source, Karaoke,
intended for domestic PA System,
and similar general Portable Hi-Fi
indoor use with a System,
rated supply voltage Portable Radio
not exceeding 250 Cassette,
volts rms. Player/Recorder,
• An electronic device Radio,
for reproduction of Radio Alarm,
audio/video, connected Tuner/Receiver,
to the supply mains, Turn tables/
either directly or Record Players,
indirectly and intended Compact Disc
for domestic and simi- Player,
lar general indoor use Audio/Video
Recorder up to 4
channels.
G P / ST / N O . 1 4 / 2 0 1 7
41 G U I D E L I N E F O R A P P R OVA L O F E L E C T R I C A L E Q U I P M E N T
No Category Description of Detail of Standards
Regulated Equipment Equipment
National Equivalent
Standard International
Standard
27 VIDEO and • is for household use; Electronic MS IEC IEC 60065:2005
VISUAL • is for receiving and appliances such as: 60065:2007 or
DISPLAY UNIT displaying information LCD, IEC 62368-1:2014
from a transmitting LED,
station or local source Plasma,
• is for the display of CRT,
public or subscription Internal Antenna/
television broadcasts. Booster,
and similar to it.
G P / ST / N O . 1 4 / 2 0 1 7
42 G U I D E L I N E F O R A P P R OVA L O F E L E C T R I C A L E Q U I P M E N T
31 CHRISTMAS • is for decorative, Lighting Chain, MS IEC 60598-1: IEC 60598-1:2008
LIGHT • display or illumination Rope Light, 2012
purposes; and Decorative/ Festive MS IEC 60598-2- IEC 60598-2-20:2010
• consists of – Light. 20:2013
- lamps or lamp holders
interconnected by
flexible cord of
less than 2.5mm²
cross-sectional area; or
- lamps within a
flexible enclosure;
and includes – any
integral power supply
or control device.
32 DOMESTIC • is for machining, Drill/Impact Drill MS IEC 60745- IEC 60745-1:2006
POWER drilling, sawing, or (Drill bit size up to 1:2010
TOOLS surface preparation; 15 mm) MS IEC 60745-2- IEC 60745-2-1:2003
(Portable • may be entirely 1:2011 +A1
Type) supported by hand
C O M M I S S I O N
during operation;
• a tool, portable type. Grinder (up to 100 MS IEC 60745- IEC 60745-1:2006
mm) 1:2010
MS IEC 60745-2- IEC 60745-2-3:2006
but does not include -
3:2010
• promoted exclusively to Sander/Polisher MS IEC 60745- IEC 60745-1:2006
the industry/ (up to 300 W) 1:2010 I
commercial sector. MS IEC 60745-2- EC 60745-2-
4:2011 4:2002+A1
E N E R G Y
Circular Saw and MS IEC 60745- IEC 60745-1:2006
circular knife 1:2010
(Cutting Blade up MS IEC 60745-2- IEC 60745-2-5:2006
to 160 mm) 5:2010
G P / ST / N O . 1 4 / 2 0 1 7
43 G U I D E L I N E F O R A P P R OVA L O F E L E C T R I C A L E Q U I P M E N T
No Category Description of Detail of Standards
Regulated Equipment Equipment
National Equivalent
Standard International
Standard
Trimmer (up to MS IEC 60745- IEC 60745-1:2006
300 W) 1:2010
Hedge trimmer and MS IEC 60745-2- IEC 60745-2-
Grass shears (up to 15:2011 15:2006
750 W)
Router and trimmer MS IEC 60745- IEC 60745-1:2006
(up to 500 W) 1:2010
MS IEC 60745-2- IEC 60745-2-
17:2012 17:2010
High Pressure MS IEC 60335- IEC 60335-1:2010
Cleaner 1:2015
MS IEC 60335-2- IEC 60335-2-
79:2007 79:2005
• is a household type; Sewing Machine MS IEC 60335- IEC 60335-1:2010
and 1:2015
• is for stitching fabric MS IEC 60335-2- IEC 60335-2-
or other material 28:2003 28:2002
G P / ST / N O . 1 4 / 2 0 1 7
44 G U I D E L I N E F O R A P P R OVA L O F E L E C T R I C A L E Q U I P M E N T
A.C. - D.C. Adapters General electrical MS IEC 61558- IEC 61558-1: 1998
• A device to appliances 1:2005
supply ac or dc Electronic Isolating MS IEC 61558-2- IEC 61558-2-6:2009
power supply Transformer 6: 2005
from an ac or dc Switching mode MS IEC 61558- IEC 61558-1:1998
source, either by power supply 1:2005
itself or as part MS IEC 61558-2- IEC 61558-2-
of an accessory, 17:2007 17:1997
for domestic and or
similar general IEC 61558-2-
indoor use 16:2009
Electric toys MS IEC 61558- IEC 61558-1:2009
1:2005
MS IEC 61558-2- IEC 61558-2-7:
7: 2007 2007
Audio video MS IEC IEC 60065:2005
equipment 60065:2007 or
IEC 62368-1:2014
C O M M I S S I O N
IT & Office products MS IEC 60950- IEC 60950-1:2005
1:2007 or
IEC 62368-1:2014
Baby Cradle, MS IEC 60335- IEC 60335-1:2010
Breast Pump, 1:2015
Electric Heated
Pillow
34 WIRE / • is unscreened Polyvinyl chloride MS 2112-5:2009, BS EN 50525-2-
CABLE / CORD and flexible ; (PVC) Insulated A1:2017 11:2011
E N E R G Y
(non-armoured) • is designed flexible cord and or
0.5mm² to for use at low cable IEC 60227-5:2011
35mm² voltage ;
• consists of two Rubber insulated MS 2127-4:2017 BS EN 50525-2-11-
or three cord and flexible 2011
cables IEC 60245-
elastomer or 1:2003+A1:2007
PVC CSV
insulated cores
of multistrand
construction ; PVC-insulated cable MS 2112-3:2009, IEC 60227-3:1993 +
• has a cross- (non-armoured) for A1:2015 A1:1997 CSV
electric power and
sectional area of supply:
each conductor - non-sheathed
from 0.5mm²
not exceeding
35mm² PVC-insulated cable MS 2112-4:2009, IEC 60227-
(non-armoured) for A1:2015 4:1992+A1:1997
electric power and CSV
supply:
- sheathed
G P / ST / N O . 1 4 / 2 0 1 7
45 G U I D E L I N E F O R A P P R OVA L O F E L E C T R I C A L E Q U I P M E N T
C HAPTER 5A
G P / ST / N O . 1 4 / 2 0 1 7
46 G U I D E L I N E F O R A P P R OVA L O F E L E C T R I C A L E Q U I P M E N T
LIST OF REGULATED ELECTRICAL EQUIPMENT THAT ARE TO BE TESTED TO
THE SPECIFIED MINIMUM ENERGY PERFORMANCE STANDARDS (MEPS)
No Equipment Type of Equipment National International Efficiency Ratings
Standard Equivalent Standard
1 Refrigerator (a) one-door National Standard: Star Star Index Value
(b) two-door MS IEC 62552-1:2016 Rating
MS IEC 62552-2:2016
MS IEC 62552-3:2016 5 + 25 % ≤ Star index
4 + 10 % ≤ Star index
Equivalent International < + 25 %
Standard: 3 - 10 % ≤ Star index
IEC 62552-1:2015 < + 10%
IEC 62552-2:2015
IEC 62552-3:2015 2 - 25 % ≤ Star index
< - 10 %
1 - 35 % ≤ Star index
< - 25 %
Minimum Star Rating Value is 2
C O M M I S S I O N
2 Air Single split wall National Standard: Rated Cooling Capacity <4.5kW
Conditioner mounted air MS ISO 5151:2012 Star Tested CSPF
conditioner with Rating (Wh/Wh)
capacity up to Equivalent International
25,000 btu/hr Standard: 5 5≥.30
ISO 5151:2010 4 4.60 ≤CSPF<5.30
E N E R G Y
1 <3.10
G P / ST / N O . 1 4 / 2 0 1 7
47 G U I D E L I N E F O R A P P R OVA L O F E L E C T R I C A L E Q U I P M E N T
No Equipment Type of Equipment National International Efficiency Ratings
Standard Equivalent
Standard
4 Domestic (a) Wall Fan ≤16 inch MS 1220:2010 N/A a)Wall fan, Desk fan and Pedestal fan
Fan
(b) Desk Fan ≤16 inch MS 2574:2014 Star Tested CSPF
Rating (Wh/Wh)
(c) Pedestal Fan ≤16 inch 5 ≥1.20
b) Ceiling fan
Star Tested CSPF
Rating (Wh/Wh)
5 ≥3.00
4 2.74 to 2.99
3 2.66 to 2.73
2 2.58 to 2.65
1 2.50 to 2.57
Minimum Star Rating Value is 2.
5 Lighting (a) T5 and T8 Double MS IEC IEC Type Lamp Minimum
Capped Fluorescent 60081:2003 60081:2003 Rating Efficacy
Lamp (W) (lm/W)
T8 18 to 30 70
≥31 80
T5 14 75
≥15 80
G P / ST / N O . 1 4 / 2 0 1 7
48 G U I D E L I N E F O R A P P R OVA L O F E L E C T R I C A L E Q U I P M E N T
(d) Self-ballasted MS IEC IEC 62612:2013 Lamp Cap Type (As in Minimum
Light Emitting 62612:2015 MS IEC 60061-1) Efficacy
Diode (LED) (lm/W)
Lamps MS IEC IEC 60061-
60061-1:2005 1:2005 G13 75
GU10 50
E27 or B22d 60
E14 60
C O M M I S S I O N
3 10.0 ≤ EER < 17.0
2 17.0 ≤ EER < 22.5
1 ≥ 22.5
E N E R G Y
4 70.0 ≤ EER < 90.0
3 90.0 ≤ EER < 140.0
2 140.0 ≤ EER < 220.0
1 ≥ 220.0
Minimum Star Rating Value is 2
G P / ST / N O . 1 4 / 2 0 1 7
49 G U I D E L I N E F O R A P P R OVA L O F E L E C T R I C A L E Q U I P M E N T
C HAPTER 6
G P / ST / N O . 1 4 / 2 0 1 7
50 G U I D E L I N E F O R A P P R OVA L O F E L E C T R I C A L E Q U I P M E N T
APPLICATION FOR CERTIFICATE OF APPROVAL
(CoA) FOR ELECTRICAL EQUIPMENT
ELECTRICAL EQUIPMENT
In improving its delivery services, the Energy Commission (ST) has developed
an online system for application of Certificate of Approval (CoA) for the
importation and manufacture of household electrical equipment. Effective 1st
October 2010, all applications are done online via e-Permit system operated by
DagangNet Technologies Sdn. Bhd. (DagangNet).
C O M M I S S I O N
(CoA) application. ST will issue the CoA if applications are in order (test report
and all required documents submitted and fees paid to ST).
E N E R G Y
E-Permit screen
The process of CoAs application is as shown in the following flow-chart:-
G P / ST / N O . 1 4 / 2 0 1 7
51 G U I D E L I N E F O R A P P R OVA L O F E L E C T R I C A L E Q U I P M E N T
6.1 NEW Application for CoA (Import/Manufacturer)
No
Registered with Apply CoR
ST
Yes
No Correct
Information given
Yes
Process Fee
RM30.00
Yes
No
Paid
G P / ST / N O . 1 4 / 2 0 1 7
52 G U I D E L I N E F O R A P P R OVA L O F E L E C T R I C A L E Q U I P M E N T
Energy Commission (ST) evaluates based on:
• Validity of Type test report
SIRIM QAS; or
<
labs under SAMM by DSM; or
<
labs under IECEE CB Scheme; or
<
labs accredited by APLAC MRA; or
<
labs accredited by ILAC MRA; or
<
labs listed under ASEAN EE MRA.
<
Application • National Deviation
re-submitted
C O M M I S S I O N
No
Complete
Yes
CoA Fees :-
• Single phase RM 220.00
E N E R G Y
• Three phase RM 330.00
No
Paid
Yes
CoA issued
G P / ST / N O . 1 4 / 2 0 1 7
53 G U I D E L I N E F O R A P P R OVA L O F E L E C T R I C A L E Q U I P M E N T
Importer Manufacturer
Yes
Equipment SIRIM
SIRIM inform ST MEPS Products affixed with inform ST
SIRIM-ST
Label & **EE
Label
No
G P / ST / N O . 1 4 / 2 0 1 7
54 G U I D E L I N E F O R A P P R OVA L O F E L E C T R I C A L E Q U I P M E N T
6.2 RENEWAL Application for CoA (Import/Manufacturer)
Registered Applicant
No
CoR still valid Apply CoR
Yes
Online application through e-Permit.
Documents required are:-
• Proof of purchase of SIRIM Label; and/or Renewal of
• PCS CoR issued
Applicant can refer to Trader Module User
C O M M I S S I O N
Guide
E N E R G Y
Applicant
Yes Validity of MEPS
to re-submit MEPS Products type test report
No
No
Complete
Yes
RENEWAL of CoA Fees:-
• Single phase RM 110.00
• Three phase RM 220.00
No
Paid
Yes
G P / ST / N O . 1 4 / 2 0 1 7
55 G U I D E L I N E F O R A P P R OVA L O F E L E C T R I C A L E Q U I P M E N T
RENEWED COA issued
Importer Manufacturer
No
G P / ST / N O . 1 4 / 2 0 1 7
56 G U I D E L I N E F O R A P P R OVA L O F E L E C T R I C A L E Q U I P M E N T
6.3 Application for CoA for EXHIBITION purposes
No
Registered with ST Apply CoR
Yes
C O M M I S S I O N
Applicant fill-up information on items related
to exhibition such as:-
• Name of electrical equipment
• Name CoR issued
• Place and Address
• Date
• Duration
Applicant Applicant can refer to Trader Module User Guide
re-applies
E N E R G Y
Application No Correct
Rejected Information
Yes
Process Fee
RM30.00
No
Paid
Yes
G P / ST / N O . 1 4 / 2 0 1 7
57 G U I D E L I N E F O R A P P R OVA L O F E L E C T R I C A L E Q U I P M E N T
Energy Commission (ST) evaluates
based on:
• Invoice; and
• Air Way Bill (AWB); or
• Bill of Lading (BL).
Application
to be
re-submitted
No
Complete
Yes
No
Paid
Equipment approved is
intended to be displayed only. Yes
It should be:-
• NOT to be sold, installed CoA EXHIBITION
or used; issued
• Re-exported (returned to
country of origin).
E N E R G Y
G P / ST / N O . 1 4 / 2 0 1 7
59 G U I D E L I N E F O R A P P R OVA L O F E L E C T R I C A L E Q U I P M E N T
APPLICATION FOR RELEASE LETTER (RL)
No
Registered
Yes
Application No Correct
Rejected Information
Yes
Yes
Application No
Comply
Rejected
Yes
RL issued
G P / ST / N O . 1 4 / 2 0 1 7
60 G U I D E L I N E F O R A P P R OVA L O F E L E C T R I C A L E Q U I P M E N T
C O M M I S S I O N
C HAPTER 8
E N E R G Y
G P / ST / N O . 1 4 / 2 0 1 7
61 G U I D E L I N E F O R A P P R OVA L O F E L E C T R I C A L E Q U I P M E N T
REGULATORY REQUIREMENTS RELATED TO NATIONAL
DIFFERENCES
No Items Requirements
1 Nominal Voltages a) N ominal Voltage
and Frequency Effective 1st Jan 2008, nominal voltage for low voltage supply in
Malaysia is 230/400V (+10%, -6%) in accordance with MS IEC
60038. The details of voltages and variations are as below:-
Nominal Voltage Percentage of Voltage Variations
(V) Variations (%) (V)
+ - Min. Max.
Until 31/12/2007
Single 240 5 10 226 252
phase,
1Ø
Three 415 5 10 373.5 436
phase,
3Ø
Commencing on 1/1/2008
Single 230 10 6 216 253
phase,
1Ø
Three 400 10 6 376 440
phase,
3Ø
b) Nominal Frequency
Nominal frequency for low voltage supply voltage in Malaysia is
allowed to fluctuate at ± 1% from 50Hz.
2 Voltages and In line with (a) above, the electrical equipment to be used in Malaysia
Frequency Marking shall be designed to operate at the country’s nominal voltage and
for Regulated frequency as follows:
Equipment
a) Voltage
Single-phase equipment shall be rated / marked at 230V or 240V. If
the equipment is rated with multiple or a range of voltages, voltage
range of 230V (+10%,-6%) shall be included.
G P / ST / N O . 1 4 / 2 0 1 7
62 G U I D E L I N E F O R A P P R OVA L O F E L E C T R I C A L E Q U I P M E N T
3 Testing Voltage Type Test Report for Equipment
and Frequency on The test shall be conducted by the Conformity Assessment Body
Electrical (CAB) at voltage variations as in the table below:
Equipment
Single phase,1Ø – 240V ± 6% : (225.6 – 254.4) V
Three phase,3Ø – 415V ± 6% : (390.1 – 439.9) V
a) Voltage
Single-phase equipment
Testing shall be conducted based on 230V(+10%,-10%) or
240V(+6%,-6%) and other relevant voltages, whenever the equip-
ment is marked with multiple or a range of voltages.
Three-phase equipment
Testing shall be conducted based on 400V(+10%,-10%) or
C O M M I S S I O N
415V(+6%,-6%), and other relevant voltages, whenever the
equipment is marked with multiple or a range of voltages.
b) Frequency
Testing shall be conducted either at 50Hz or 60Hz, whichever is
more unfavourable.
4 Power supply cord Appliances shall be fitted with a suitable and appropriately approved
and main plug power supply cord and mains plug. Both are regulated equipment
E N E R G Y
requirements and must be approved by the regulatory body before it can be used
with the appliances.
a) The Power Supply Cord shall be certified to:-
• MS2112-5 or BS EN 50525-2-11 or IEC 60227-5
(PVC insulated - flexible cables/cords);or
• or MS 2127-4 or IEC 60245-1 & IEC 60245-4
(Rubber insulated - flexible cables/cords)
b) The mains Plug to be used in Malaysia shall be as follows:
• 13A fused plug complying with MS 589-1 or BS 1363:PT.1;
• 15A plugs complying with MS 1577;
• 2.5A, 250V, flat non-rewireable two-pole plug with cord for the
connection of class II equipment comply with MS 1578 or BS
EN 50075.
5 Class I and Class II Only Class I with symbol as in Figure 1 and Class II with symbol as
Equipment in Figure 2 are allowed to be used in Malaysia.
G P / ST / N O . 1 4 / 2 0 1 7
63 G U I D E L I N E F O R A P P R OVA L O F E L E C T R I C A L E Q U I P M E N T
No Items Requirements
Note: Value of COP for No.1,2,3 & 4 are included in the MEPS
requirements
G P / ST / N O . 1 4 / 2 0 1 7
64 G U I D E L I N E F O R A P P R OVA L O F E L E C T R I C A L E Q U I P M E N T
7 a) Component Standards for Fluorescent Lamp Fitting are MS IEC 60598-2-1 or
used for IEC 60598-2-1 (for fixed luminaries) and MS IEC 60598-2-2 or
Fluorescent Lamp IEC 60598-2-2 (for recessed luminaries). Components such as
Fitting glow starter, starter holder, lamp holder, capacitor, connecting
device, ballast and internal wiring are used as part of the fitting.
Thus, the components used for both standards mentioned shall
comply to the following standards:
Components Standards
C O M M I S S I O N
& MS IEC 61049 or IEC 61049
E N E R G Y
MS IEC 141 PT.2 or IEC 60921 with
modification
G P / ST / N O . 1 4 / 2 0 1 7
65 G U I D E L I N E F O R A P P R OVA L O F E L E C T R I C A L E Q U I P M E N T
b) Component Standards for LED Lamp Fitting are MS IEC 60598-2-1 or IEC 60598-2-1
used for LED (for fixed luminaries), MS IEC 60598-2-2 or IEC 60598-2-2 (for
Lamp Fitting recessed luminaries), MS IEC 60598-2-4 or IEC 60598-2-4 (Portable
LED Lamp), MS IEC 60598-2-12 or IEC 60598-2-12 (LED Night Lamp)
and MS IEC 60598-2-8 or IEC 60598-2-8 (LED hand lamp).
Components such has driver, module, lampholder, connecting device
and internal wiring are used as part of the fitting. Thus, the components
used for above standards mentioned shall comply to the following
standards:
Components Standards
Driver MS IEC 61347-1 and MS IEC 61347-2-13
Module / Lamp MS IEC 62031 or MS IEC 62776 or MS IEC
62560
G P / ST / N O . 1 4 / 2 0 1 7
66 G U I D E L I N E F O R A P P R OVA L O F E L E C T R I C A L E Q U I P M E N T
Electrical equipment shall be constructed to be used with power
supply cord and power plug which comply with Malaysia’s
requirements and standards.
11. Requirements for To meet the requirements of the MEPS, the performance criteria
C O M M I S S I O N
MEPS when tested using the relevant testing standards has to be met.
The testing standards and performance criteria have been set as
prescribed in Chapter 5A.
12. Requirement for To meet the requirements of the LED Photobiological Safety Class
LED Luminaires of Exempt Group according to standard MS IEC 62471 or IEC
62471.
E N E R G Y
G P / ST / N O . 1 4 / 2 0 1 7
67 G U I D E L I N E F O R A P P R OVA L O F E L E C T R I C A L E Q U I P M E N T
CHAPTER9
G P / ST / N O . 1 4 / 2 0 1 7
68 G U I D E L I N E F O R A P P R OVA L O F E L E C T R I C A L E Q U I P M E N T
LABELLING OR CERTIFICATION MARK
A. Objective and rationale
Labeling or marking of regulated electrical equipment will enable consumers
to differentiate between the approved and non-approved regulated electrical
e q u i p m e n t . I t a l s o s e r v e s a s a d e t e r re n t a n d a m e a n s t o c h e c k f o r
non-approved regulated electrical equipment in the market.
B. Labeling or Marking
All regulated electrical equipment approved by the Commission must be
labeled or marked in accordance with regulation 98 of the Electricity Regulations
1994 and shall be done in the manner which has been determined by the
Commission as below:
i) Sticker Type
There are two types of SIRIM-ST label which shall be affixed on the
C O M M I S S I O N
equipment.
E N E R G Y
New SIRIM-ST Label Old SIRIM-ST Label
(effective 01-01-2015)
Figure 3: SIRIM-ST label for Imported
b) SIRIM-ST label
Local manufacturer and importer who have entered PCS shall purchase
SIRIM-ST label and affix on each equipment. Sample of the label is as
shown below:
New SIRIM-ST Label Old SIRIM-ST Label
(effective 01-01-2015)
G P / ST / N O . 1 4 / 2 0 1 7
69
69 G U I D E L I N E F O R A P P R OVA L O F E L E C T R I C A L E Q U I P M E N T
ii) Embossed Type
a) For manufacturer or importer which participated in SIRIM-ST Label
Licensing Programmed, they may use the SIRIM Certification Mark as
shown in Figure 5 below.
SIRIM
CERTIFIED TO YY : XXXX
CERTIFICATION NO: xxxxxxxx
SIRIM-ST Label Licensing Programme
Figure 5: SIRIM Certification Mark
b) For small regulated electrical equipment such as lampholder, starter-
holder, glow starter and cable, SIRIM Certification Mark shall be
emboss in their products.
The SIRIM-ST label or SIRIM Certification Mark shall be affixed on the regulated
electrical equipment itself in a legible manner. The SIRIM-ST label shall not be
affixed on the packaging.
1 Details emboss on cable are SIRIM Cert. Mark/labs, standards, size of cable, manufacture’s company.
G P / ST / N O . 1 4 / 2 0 1 7
70 G U I D E L I N E F O R A P P R OVA L O F E L E C T R I C A L E Q U I P M E N T
Energy rating: 1 to 5-star
Appliance type
(Myriad Pro, Bold, Size 5pt)
Appliance energy rating
(Equals the number in the energy C : 6
rating) M : 89
Y : 75
K : 1
Information on the brand & model
(Myriad Pro, Bold, Size 5pt) C : 1
M : 5
Y : 91
Energy consupmtion in (kWh/year) K : 0
(Myriad Pro, Bold, Size 7pt)
C : 32
M : 22
(Myriad Pro, Regular, Size 3pt) Y : 17
K : 4
Energy savings compared to the
lowest 2-Star rated product C : 0
M : 0
(in percentage) Y : 0
(Myriad Pro, Bold, Size 3pt) K : 100
C O M M I S S I O N
(Myriad Pro, Bold/Italic, Size 3pt)
(Myriad Pro, Italic, Size 3pt)
E N E R G Y
guidelines for MEPS products are as below:-
a) Air Conditioner
• Size for air conditioners energy efficiency label is 9 cm (width) X
13.5 cm (height).
• Calculation guideline shown as below:-
CSPF Lowest 2-Star = 2.9 for rated cooling capacity 4.5W to 7.1Kw
CSPF Measured = Obtained from test report
G P / ST / N O . 1 4 / 2 0 1 7
71 G U I D E L I N E F O R A P P R OVA L O F E L E C T R I C A L E Q U I P M E N T
Label affixed
b) Domestic Fan
• Size for fan’s energy efficiency label is 4 cm (width) X 6 cm (height).
• Calculation guideline shown as below :-
c) Refrigerator
• Size for refrigerator’s energy efficiency label is 8 cm (width) X 12 cm
(height).
• Calculation guidelines shown as below:-
G P / ST / N O . 1 4 / 2 0 1 7
72 G U I D E L I N E F O R A P P R OVA L O F E L E C T R I C A L E Q U I P M E N T
Annual Energy Consumption Calculation Guideline:
A = Annual Energy Consumption (kwh)
A =E Total (Obtained From the Test Report)
Percentage Energy Saving Compared to Lowest 2-Star
Rating Compared Calculation Guideline:
C O M M I S S I O N
d) Television
• Size for television’s energy efficiency label is 7cm (width) X 11 cm (height).
• Calculation guidelines shown as below:-
E N E R G Y
Percentage Energy Saving Compared to Lowest 2-Star
Rating Compared Calculation Guideline:
Percentage of energy saving compared to the lowest
2-Stars model
0.0016 x (Screen Area, cm 2) + 8.8
= 100% - (100 x )
EEF Tested
Where EEFTested can be obtained from the test report.
Label affixed
e) Lighting
• Declared efficacy value (lumen/watt) of the lamp and testing hours
that has been conducted must be stated at packaging of the individual
product.
• For Light Emitting Diode (LED) Lamps:-
1) The Lumens maintenance test will be carried out every 1,000 hours
until the completion of 6,000 hours. An interim report will be issued
after completing the first 1,000 hours. The interim report can be used
for CoA application. The test will be continued to complete the 6,000
hours. A final full test report will then be issued to supersede the
interim report. This procedure will only apply to the products tested
according to MS 62612 (P) standard in local labs accredited by Standards
G P / ST / N O . 1 4 / 2 0 1 7
73 G U I D E L I N E F O R A P P R OVA L O F E L E C T R I C A L E Q U I P M E N T
Malaysia i.e SIRIM QAS International Sdn Bhd and QAV Technologies
Sdn Bhd. For LED lamps tested according to IEC 62612 in overseas
accredited labs, only full test reports will be accepted for COA
application.
2) Once the CoA has been issued, the applicant is required to state the
Efficacy value onto the packaging of the product together with the
number of hours the LED has been tested as per example below :-
i) After completing first 1,000 hours test ii) After completing first 6,000 hours test
3) If the product fails after the first 1,000 hours before completing the
6,000 hours, the testing body is required to inform Energy Commission
of such failure. The Energy Commission will then not approve the
application for the renewal of the CoA.
* For more details please refer to Guideline for Obtaining The Certificate
Of Approval (COA) for LED Lamps Under Minimum Energy Performance
Standards (MEPS) in Energy Commission website.
f) Washing Machine
MEPS for washing Machine will be implemented on
1st September 2018.
• Size for washing machine energy efficiency label is
8 cm (width) X 12 cm (height).
• Calculation guideline shown as below:-
E N E R G Y
G P / ST / N O . 1 4 / 2 0 1 7
75 G U I D E L I N E F O R A P P R OVA L O F E L E C T R I C A L E Q U I P M E N T
Appendix A
G P / ST / N O . 1 4 / 2 0 1 7
76 G U I D E L I N E F O R A P P R OVA L O F E L E C T R I C A L E Q U I P M E N T
APPLICATION FOR CERTIFICATE OF REGISTRATION
(CoR) TO MANUFACTURE / IMPORT
A. Application Procedure
1) Applicants who require applying for Certificate of Approval (CoA)
shall register as registered manufacturer/importer with the Energy
Commission.
2) Applicant has to ensure their registration as registered manufacturer/
importer is valid prior to apply for CoA.
3) Registration can be made through e-DIK system http://edik.st.gov.my.
The Energy Commission will issue the successful applicant with a
Certificate of Registration (CoR) to Manufacture/Import.
4) A CoR shall be valid for not less than 1 year and not exceeding 5 years
from the date of issue or renewal.
5) Renewal of CoR shall be made within one (1) month before the expiry
date and not less than 14 days before the expiry date.
C O M M I S S I O N
6) Application for Renewal of CoR received less than 14 days before the
expiry date will automatically be rejected. In this case applicant needs
to apply for a new CoR.
7) Registered manufacturer/importer will be issued with Form V1
Certificate of Registration to Manufacture/Import as in Appendix F.
B. Documents Required
Documents required for Certificate of Registration to manufacture and
E N E R G Y
import are as follows:
(i) Business Registration with Companies Commission of Malaysia
(under Business Registration Act)
• Certificate of Business Registration (Form D)
• Others Business Information
or
Company Incorporation with Companies Commission of Malaysia (under
Companies Act)
• Form 9 / Form Section 17
• Form 44 / Form Section 46(3)
• Form 49 or latest Form of Annual Return of a Company / Form
Section 14 / Form Section 68 / Form Section 58
• Form 24 / Form Section 51 / Form Section 78
(ii) Warehouse Tenancy Agreement
(iii) Business License from Local Authority (i.e. Dewan Bandaraya Kuala
Lumpur)
(iv) Photo of the premise showing the business signboard
(v) any other information/document as the Commission deems necessary
C. Annual Fee
No Fee Imposed.
G P / ST / N O . 1 4 / 2 0 1 7
77 G U I D E L I N E F O R A P P R OVA L O F E L E C T R I C A L E Q U I P M E N T
Appendix B
G P / ST / N O . 1 4 / 2 0 1 7
78 G U I D E L I N E F O R A P P R OVA L O F E L E C T R I C A L E Q U I P M E N T
APPLICATION FOR CERTIFICATE OF APPROVAL (CoA)
TO MANUFACTURE, IMPORT, DISPLAY OR ADVERTISE
ELECTRICAL EQUIPMENT.
A. Application Procedure
1) Applicant is required to apply for Certificate of Approval (CoA) through
e-Permit http://epermit.dagangnet.com.
2) Applicant shall refer to Dagang Net Technologies Sdn Bhd for details
on online registrations at toll free 1-300-133-133.
3) Applicant is required to apply for Certificate of Registration prior to
him/her applying for CoA.
4) Details for application to be a registered Manufacturer/Importer are as
in Appendix A.
5) Applicant shall complete the application by providing all information
C O M M I S S I O N
correctly and attach all required documents.
6) Information such as Name of Electrical Equipment, Brand and Model
shall not be correct or else application will be rejected.
7) Detailed steps on application procedures are available at e-Permit
website on Trader Module User Guide.
8) Technical documents required for CoA to manufacture and import are
as follows:
E N E R G Y
• Type Test Report validity period not exceed five (5) years from the
date of testing and shall not less than 12 month from the date of
CoA application;
• List of components;
• Instruction manual;
• Technical specification and catalogue; and
• Sample of the product, if requested.
9) Applicant shall pay RM30.00 as processing fee.
B. Type Test Report
(i) Type Test Reports that are recognised by the Commission shall be
produced by any of the following laboratories:-
G P / ST / N O . 1 4 / 2 0 1 7
79
79 G U I D E L I N E F O R A P P R OVA L O F E L E C T R I C A L E Q U I P M E N T
4) Laboratories (in the scope of its accreditation) which are
accredited by the accreditation body* that have signed the Asia
Pacific Laboratory Accreditation Cooperation (APLAC) MRA
– http://www.aplac.org. ; or
5) Laboratories (in the scope of its accreditation) which are
accredited by the accreditation body* that have signed the
International Laboratory Accreditation Cooperation (ILAC) MRA
– http://www.ilac.org. ; or
6) Laboratories (in the scope of its accreditation) listed as
Designated Testing Laboratory (DTL) under ASEAN Sectoral
Mutual Recognition Agreement for Electrical and Electronic
Equipment (ASEAN EEE MRA); or
(ii) For items (3), (4), (5) and (6), testing should include the national
deviation in Malaysia. The requirements of national deviation are as in
Chapter 8.
*Note: Department of Standard Malaysia (DSM) is one of the (APLAC/ILAC) MRA signatory.
The requirements and standards of Power Supply Cords and Power Plugs
are as stated in Chapter 8, No.4.
G P / ST / N O . 1 4 / 2 0 1 7
80 G U I D E L I N E F O R A P P R OVA L O F E L E C T R I C A L E Q U I P M E N T
C O M M I S S I O N
Appendix C
E N E R G Y
G P / ST / N O . 1 4 / 2 0 1 7
81 G U I D E L I N E F O R A P P R OVA L O F E L E C T R I C A L E Q U I P M E N T
RENEWAL OF CERTIFICATE OF APPROVAL (CoA) TO
MANUFACTURE, IMPORT, DISPLAY OR ADVERTISE
ELECTRICAL EQUIPMENT
Renewal of CoA shall be made not less than 14 days before its expiry date as
required under regulation 106 of Electrical Regulations 1994.
A. Application Procedure
1) Applicant (registered Manufacturer / Importer) is required to apply for
Renewal of CoA through e-Permit.
2) Applicant whose previous Certificate of Registration has expired is
required to re-apply with procedures as in Appendix A.
3) All approved CoA will be displayed at e-Permit and applicants may
renew CoA by selecting the previous Job Number or Application ID.
4 ) Applicant shall complete his/her application by providing all
information correctly and attaching all required documents.
5) Unwanted models shall be deleted/removed from e-Permit before
submitting the renewal application for CoA to Energy Commission
(ST).
6) Application will be rejected if unwanted models are NOT removed
from e-Permit. In this case applicant needs to apply for a new CoA.
7) Renewal of CoA shall be made within two (2) months before the
expiry date and not less than 14 days before the expiry date.
8) Application for Renewal of CoA received less than 14 days before the
expiry date will automatically be rejected. In this case applicant needs
to apply for a new CoA.
G P / ST / N O . 1 4 / 2 0 1 7
82 G U I D E L I N E F O R A P P R OVA L O F E L E C T R I C A L E Q U I P M E N T
C. Annual Fee for Renewal of CoA
An annual fee of RM110.00 for single phase and RM220.00 for three
phase products shall be paid upon approval of the CoA.
C O M M I S S I O N
SIRIM Certification Mark.
Electrical equipment which fails the Consignment Test need to be sent
back to the country of origin or shall be destroyed.
Electrical equipment shall be constructed with power supply cord and
power plug which comply with Malaysia’s requirements and standards.
The requirements and standards of Power Supply Cord and Power Plug
are as stated in Chapter 8, No.4.
E N E R G Y
G P / ST / N O . 1 4 / 2 0 1 7
83 G U I D E L I N E F O R A P P R OVA L O F E L E C T R I C A L E Q U I P M E N T
Appendix D
G P / ST / N O . 1 4 / 2 0 1 7
84 G U I D E L I N E F O R A P P R OVA L O F E L E C T R I C A L E Q U I P M E N T
APPLICATION FOR CERTIFICATE OF APPROVAL (CoA)
FOR EXHIBITION PURPOSES
A. Application Procedure
1) Applicant is required to apply for a CoA for Exhibition through
e-Permit http://epermit.dagangnet.com.
2) Applicant is required to apply for Certificate of Registration prior to
him/her applying for CoA.
3) Details for applications to be registered Manufacturer/Importer can
be referred in Appendix A.
4) Applicant shall complete application by providing all information
correctly and attach all required documents.
5) Information such as Name of Electrical Equipment, Brand and Model
shall be correct or else application will be rejected.
C O M M I S S I O N
6) Detailed steps on application procedures are available at e-Permit
website on Trader Module User Guide.
7) Technical documents required for CoA for Exhibition purposes are:
i) A Cover letter to specify:
Name, place, address, exhibition date and length of exhibition
or offer letter to participate in the related exhibition.
ii) The Invoice and Air Way Bill (AWB) for importation by air or Bill of
E N E R G Y
Lading (BL) for importation by sea should be made available.
8) Applicant shall pay RM30.00 as processing fee.
B. Exhibition Fee
Exhibition Fee of RM 220.00 shall be paid upon approval of the CoA.
G P / ST / N O . 1 4 / 2 0 1 7
85 G U I D E L I N E F O R A P P R OVA L O F E L E C T R I C A L E Q U I P M E N T
Appendix E
G P / ST / N O . 1 4 / 2 0 1 7
86 G U I D E L I N E F O R A P P R OVA L O F E L E C T R I C A L E Q U I P M E N T
APPLICATION FOR RELEASE LETTER (RL)
A. Application Procedure
1) The Energy Commission (ST) will issue a Release Letter to Customs as
blanket approval for exemption from Certificate of Approval (CoA) for
importation of ST’s regulated electrical equipment.
2) Release Letter is applicable for Special Purpose, Concert, Factory
Research, Quality Research, Re-Work and Re-Export, Imported Components
used for Equipment Manufactured for 100% Export or Local Market and
Transit.
3) For non-regulated equipment, applicant may request Release Letter for
Customs clearance purposes.
4) Application of Release Letter shall be apply through e-Permit at http://
epermit.dagangnet.com.
5) Applicant shall complete application by providing all information correctly
and attach required documents.
C O M M I S S I O N
6) Information such as Name of Electrical Equipment, Brand and Model
shall be correct or else application will be rejected.
B. Fee for Release Letter
There is no fee imposed for Release Letter.
C. Technical Documents Required
E N E R G Y
1. Regulated Equipment for COA Exemption
i) Specific Purpose - Oil Rig, Tanker, SIRIM Test, Electric Fence Etc.
• Cover letter to specify the purpose of import, name and address
of user as well as place of use,
• Invoice and Air Way Bill (AWB) for importation via air or Bill of
Lading (BL) for importation via sea should be made available.
• All applications are subjected to Energy Commission’s approval.
ii) Concert
• The imported equipment shall not be sold, advertised and
exhibited and must be re-exported after the concert.
• Invoice and Air Way Bill (AWB) for importation via air or Bill of
Lading (BL) for importation via sea should be made available.
• Equipment catalogue should also be made available.
iii) Factory Research
• The imported sample shall not be sold, advertised or exhibited
and the sample must be disposed after the end of the research.
• Invoice and Air Way Bill (AWB) for importation via air or Bill of
Lading (BL) for importation via sea should be made available.
• A maximum of 10 units per model is allowed for factory
research. A copy of manufacturing license should also be made
available
G P / ST / N O . 1 4 / 2 0 1 7
87 G U I D E L I N E F O R A P P R OVA L O F E L E C T R I C A L E Q U I P M E N T
iv) Quality Research
• The imported sample shall not be sold, advertised or exhibited
and the sample must be disposed after end of research.
• Invoice and Air Way Bill (AWB) for importation via air or Bill of
Lading (BL) for importation via sea should be made available.
• A maximum of 4 units per model is allowed for quality or market
research.
2. Non-Regulated equipment
• Equipment catalogue;
• Test report; and/or
• Sample if required
G P / ST / N O . 1 4 / 2 0 1 7
88 G U I D E L I N E F O R A P P R OVA L O F E L E C T R I C A L E Q U I P M E N T
C O M M I S S I O N
Appendix F
E N E R G Y
G P / ST / N O . 1 4 / 2 0 1 7
89 G U I D E L I N E F O R A P P R OVA L O F E L E C T R I C A L E Q U I P M E N T
FORM V1
(regulation 97C)
ELECTRICITY SUPPLY ACT 1990
The Energy Commission hereby certifies in pursuance of section 4(k) of the Electricity
Supply Act 1990 that
…………………………………………………………………………………………………..................
................................................................................................................................................
at ……………………………………………........................................................................... has
satisfied the requirements of the Act and the Regulations made thereunder.
this Certificate of Registration shall be valid for a period of ………... years(s) from the
date of issue stated below.
Energy Commission
G P / ST / N O . 1 4 / 2 0 1 7
90 G U I D E L I N E F O R A P P R OVA L O F E L E C T R I C A L E Q U I P M E N T
C O M M I S S I O N
Appendix G
E N E R G Y
G P / ST / N O . 1 4 / 2 0 1 7
91 G U I D E L I N E F O R A P P R OVA L O F E L E C T R I C A L E Q U I P M E N T
FORM V
(regulation 97)
ELECTRICITY SUPPLY ACT 1990
CERTIFICATE OF APPROVAL
In accordance with regulation 97 of the Electricity Regulations 1994, this Certificate is
issued to ……………............................................………………………………………...…………
(name of importer)
at……………………………………………………........................................................................
(address)
and approval is given to
1 *
import display sell advertise
the equipment, the description of which are set out below direct from
…………………………...............................................................................................................
(name and country of manufacturer)
and the equipment is in compliance with:
(a) Standard : ...........................................................
(b) Type Test Report No : ........................................
for a period of one year from the date of issue/renewal* shown hereunder subject to
the following conditions:
(state)
Date of issue/renewal*: ....…………….…....... Expiry Date : ...……………...........
Approval No :....................……………….....…. Fee RM : ……………….................
Description of Equipment
Equipment :...........................................................
Trade Name :.................…….......…………..............
Type/Model :.....................................………………..
Specification Of Equipment
Voltage ..........……………………......Volts Power ......……………....... watts
Frequency ........…………….........…......Hz Current .......……….……...... Amp
.......................……....................…….....
Energy Commission
1. Equipment approved is intended to be displayed only and not to be sold, installed or used.
* Delete whichever is not applicable.
G P / ST / N O . 1 4 / 2 0 1 7
92 G U I D E L I N E F O R A P P R OVA L O F E L E C T R I C A L E Q U I P M E N T
C O M M I S S I O N
Appendix H
E N E R G Y
G P / ST / N O . 1 4 / 2 0 1 7
93 G U I D E L I N E F O R A P P R OVA L O F E L E C T R I C A L E Q U I P M E N T
FORM W
(regulation 97)
ELECTRICITY SUPPLY ACT 1990
CERTIFICATE OF APPROVAL
In accordance with regulation 97 of the Electricity Regulations 1994, this Certificate is
issued to ……………………………………………………...……............................................……
(name of holder’s company)
at……………………………………………………........................................................................
(address)
and approval is given to-
the equipment, the description of which are set out below direct from
…………………………..............................................................................................................
(name of manufacturer)
…………………………...............................................................................................................
(address of manufacturer)
and the equipment is in compliance with:
(a) Standard : ...........................................................
(b) Type Test Report No : ........................................
for a period of one year from the date of issue/renewal* shown hereunder subject to
the following conditions:
(state)
Equipment :...........................................................
Trade Name :.................…….......…………..............
Type/Model :.....................................………………..
Specification Of Equipment
.......................……....................…….....
Energy Commission
1. Equipment approved is intended to be displayed only and not to be sold, installed or used.
* Delete whichever is not applicable.
G P / ST / N O . 1 4 / 2 0 1 7
94 G U I D E L I N E F O R A P P R OVA L O F E L E C T R I C A L E Q U I P M E N T
C O M M I S S I O N
Appendix I
E N E R G Y
G P / ST / N O . 1 4 / 2 0 1 7
95 G U I D E L I N E F O R A P P R OVA L O F E L E C T R I C A L E Q U I P M E N T
FORM U1
(regulation 97B)
ELECTRICITY SUPPLY ACT 1990
The Energy Commission hereby certifies in pursuance of section 4(l) of the Electricity
Supply Act 1990 that
…………………………………………………………………………………………………..................
.................................................................................................................................................
at .......……………………………………………..........................................................................
has satisfied the requirements of the Act and the Regulations made thereunder.
this Certificate of Registration shall be valid for a period of ………... year(s) from the
date of issue stated below.
Energy Commission
* Not less than one year and not more than three years.”;
G P / ST / N O . 1 4 / 2 0 1 7
96 G U I D E L I N E F O R A P P R OVA L O F E L E C T R I C A L E Q U I P M E N T
C O M M I S S I O N
Appendix J
E N E R G Y
G P / ST / N O . 1 4 / 2 0 1 7
97 G U I D E L I N E F O R A P P R OVA L O F E L E C T R I C A L E Q U I P M E N T
ACCEPTABLE AND NON-ACCEPTABLE 2-PIN MAINS PLUG
OTHER
RATINGS : None
OUTLINE :
Version ll :
19.0
0.5
19.0
10mm
TYPICAL PLUG
ACCEPTABLE
G P / ST / N O . 1 4 / 2 0 1 7
98 G U I D E L I N E F O R A P P R OVA L O F E L E C T R I C A L E Q U I P M E N T
SOURCE : CEE 7: 1963 Standard Sheet XVlI
IEC 83: 1975 Standard C5
NOTES : Intended to be fitted to class ll (double insulated)
appliances 2.5 A, 250 V
Two pole - no earth contact
OTHER
RATINGS : None
OUTLINE :
19.0
C O M M I S S I O N
19.0
E N E R G Y
19.0
TYPICAL PLUG
UNACCEPTABLE
G P / ST / N O . 1 4 / 2 0 1 7
99 G U I D E L I N E F O R A P P R OVA L O F E L E C T R I C A L E Q U I P M E N T
This page has been intentionally left blank
G P / ST / N O . 1 4 / 2 0 1 7
100 G U I D E L I N E F O R A P P R OVA L O F E L E C T R I C A L E Q U I P M E N T