TA BLE OF CONTENTS
1 PREFA CE .................................................................................................................. 5
2 COMPA TIBILITY ..................................................................................................... 5
3 CONV E NT IO NS ........................................................................................................ 5
4 PRE- CO NFIGURA TIO N STEPS ................................................................................ 6
4.1 CONNECT TO THE 7360FX OLT & 7356REM MDU ISAM VIA CRAFT T ERMINAL ...........................6
7 OLT SERV ICE PROV ISIO NING - INITIA L CO NFIGURA TIO N.............................. 15
7.1 CREATE UPSTREAM BANDWIDTH PROFILES (DBA) ............................................................................. 15
9 SERV ICE PROV ISIO NING – SA MPLE SERV ICE CO NFI GURA TIO N ..................... 24
9.1 CREATE SFP ONT INFRASTRUCTURE................................................................................................... 24
1 Preface
All rights reserved. Passing on and copying of this document, use and
This document describes the process of configuring a 7356REM ISAM for use in PT
Telkom network for the Vectoring Field Trial.
2 Compatibility
This document supports the configuration of the 7356REM ISAM with the following
release:
ISAM R5.0 or higher
3 Conventions
The following conventions are used throughout this document:
from Alcatel-Lucent.
4 Pre-configuration steps
4.1 Connect to the 7360FX OLT & 7356REM MDU ISA M via Craft Termina l
Connect the PC’s Serial port to the craft port of the 7356REM ISAM (LCMI). The craft
port is located on the NRNT-A card.
Pin-out of RJ45 connector:
DTR Data-Terminal-Ready 3 I
EG Signal Ground 4 Ref
RXD Receive-Data 5 O
TXD Transmit-Data 6 I
CTS Clear-To-Send 7 O
RTS Request-To-Send 8 I
Open HyperTerminal (or equivalent) and setup the serial connection with following
parameters:
Choose ‘C’ to enter the TL1. The factory username and password are:
Username = isadmin
Password = i$@mad-
Note: The system will reset and come up with an empty database. Follow step 4.1 to
re-connect to the system.
Configure 1 uplink to connect to the network, port 1 on NT in 1GE mode for connection
to Metro-E.
isadmin># configure port nt-a:xfp:1 ethernet speed 1000
isadmin># configure port nt-a:xfp:1 ethernet autonegotiate
limited
isadmin># configure port nt-a:xfp:1 no shutdown
Note: The bold part needs to be replaced by the actual value found on the node
information sheet
Note: The bold part needs to be replaced by the actual value found on the node
information sheet
Note: System is now reachable from EMS and the network.
Note: The bold part needs to be replaced by the actual value found on the node
information sheet
Note: The total length of the prompt string needs to be less or equal than 28
characters. This means the system ID can only be 18 characters.
Note: After setting this slot numbering the operator needs to logout and login again to
activate the new setting
timeout 0
All rights reserved. Passing on and copying of this document, use and
Note: The bold part needs to be replaced by the actual value found on the node
information sheet
Note: The bold part needs to be replaced by the actual value found on the node
information sheet
Note: The NTP server IP points to the AMS Server
snooping mrouter-port
All rights reserved. Passing on and copying of this document, use and
Note: The bold part needs to be replaced by the actual value found on the node
information sheet.
VoD VLAN:
Multicast VLAN:
from Alcatel-Lucent.
Note: The bold part needs to be replaced by the actual value found on the node
information sheet.
11 Document History
- END OF DOCUMEN T -