Вы находитесь на странице: 1из 3

KEMPEROL® V 210

Waterproofing
Shelf Life
Can be stored unopened in a cool, dry, frost-free place.
Use by: see label on pack.
KEMPEROL® CP Catalyst Powder ist separat zu
lagern.

Usage guide
Depending on the condition of the substrate : 2,8 - 3,6
kg/m²

Usage guide
Depending on the condition of the substrate: 2,8 - 3,6
kg/m² giving a coating thickness of approx. 2.0 mm.
(see technical information TI 03 - layer thicknesses ac-
cording to guidelines).

Properties
Form Comp. A liquid
Comp. B liquid
Comp. C powder
Uses
Standard colour Grey
• Used in conjunction with KEMPEROL® Fleece for Special colours On request
waterproofing details, joints and general water- Workability time* approx. 15 min
proofing of structures
As a waterproofing system for flat roofs, plant hold- Rainproof after* approx. 30 min

ers, buildings, etc. Can be walked on after* approx. 6 h
• For application under green roofs Cured after* approx. 3 d
• For new construction and remedial projects
Further coating after* approx. 6 h
• Can be applied to virtually any substrate
• Not suitable for indoor application * Values obtained at a temperature of 23 °C - 50% rel. humidity. These values vary
depending on the weather conditions, such as wind, humidity and temperature.
** valid for joint areas. For installation on the entire surface after 2 d.
Features
CE-Marking
• Proven since 1970
• Cold applied Component to 2 ETA 03/0025
• Water vapour permeable
Water vapour diffusion factor μ ~ 10960
• Bridges cracks
• Root resistant according to FLL-testing Resistance to wind loads >= 50 kPa
• Third-party monitoring External fire performance BROOF(t1) **
• Can be walked on for maintenance
• 3-part Reaction to fire E ***
• Based on: Polyester resin Statement to dangerous substances does not con-
tain any
Pack sizes
Working life W3
KEMPEROL® V 210 Waterproofing
Climatic zones M and S
component A 23,4 / 9,4 kg,
Imposed loads P1 to P4
component B 25 / 10 kg
Roof slope S1 to S4
KEMPEROL® CP Catalyst Powder
component C 1,6 / 0,6 kg Lowest surface temperature TL4
Highest surface temperature TH4 During application the surface temperature must be 3
K above the dew point. If the dew point is not reached,
** Classification in accordance with EN 13501-5
2006: DIN 4102-7 - resistance to spreading fire and radiant heat.
the surface to be primed can form a moisture film and
*** Classification in accordance with EN 13501-1. cause separation (DIN 4108 - 5 Tab.1).
2006: DIN 4102-1. Classification is done in class B2.
At ambient temperatures below +10 °C, add KEMPER-
Technical data OL® UP-A Cold Activator, at temperatures exceeding
25 °C add KEMPEROL® UP-I Inhibitor to KEMPEROLV
European technical ap- ETA 03/0025
210 Waterproofing component B.
proval:
Levels of categories of use according to ETAG 005 re- Mixing
garding: KEMPEROL® CP Catalyst Powder component C to be
mixed thoroughly into KEMPEROLV 210 Waterproof-
Properties Test method ing component A: Dissolving time: at +20 °C approx.
Elongation >44 % DIN EN ISO 527 20 min KEMPEROLV 210 Waterproofing component
B must be stirred thoroughly and mixed with a mixing
Tensile strength >8 N/mm2 DIN EN ISO 527
ratio of 1:1 with component A + C until you achieve a
Water vapour diffu- 10960
streak-free mixture.
sion resistance val-
ue (µ) Application
Resistance to stat- High resistance EOTA TR-007
ic indentation (class: P4)
Apply approximately 2/3 of the KEMPEROLV 210 Wa-
terproofing oil in the KEMPEROL® Fleece and embed
Resistance to dy- High resistance EOTA TR-006
namic indentation (class: P4)
with a perlon roller. Remove air bubbles and overlap
fleece sections by 5 cm. Apply the remaining 1/3 of the
Resistance to wa- No leak (1m water EOTA TR-003
ter pressure column, 24h)
KEMPEROLV 210 Waterproofing ensuring complete
saturation of the fleece.
Resistance to de- >2,0 N/mm2 (with EOTA TR-004
lamination primer) To prevent premature contamination of KEMPER-
Crack-bridging ca- up to 1,5mm EOTA TR-013 / OLV 210 Waterproofing , scatter KEMPEROL® TP Tal-
pability (-30°C) / up to EOTA TR-008 cum Powder on the seal at the earliest after 12 hours,
2mm (-10°C) spread and sweep up with a fine broom.
Hardness (Shore 70 DIN 53505 Joints on door and window elements etc. with a height
A) of < 15 cm (as a water-bearing level from the upper
Resistance to root root resistant (acc. EN13948 edge) should have at least 5 cm of overlap. Connec-
penetration to FLL test) tions to the surface sealant should be made with at
Accelerated aging Passed - no signifi- EOTA TR-011 least a 10 cm of overlap.
by heat cant changes
The thickness of the membrane needs to meet mini-
UV aging in the Passed - no signifi- EOTA TR-010
presence of mois- cant changes mum requirements defined in the European Technical
ture Approval ETA. National regulations must be followed.
Accelerated aging Passed (180d, EOTA TR-012 Alkaline protection
by hot water 60°C)
The waterproofing provides limited alkaline resistance.
Fire class class E EN 13501-1 Therefore, if a sustained load is expected, apply KEM-
Resistance to fly- Passed (class Broof EN 13501-5 PERTEC® EP Primer, KEMPERTEC® EP5 Primer or
ing sparks (t1)) KEMPERTEC® AC Primer to the waterproofing and
VOC content 3.8 % ISO 11890-2 scatter KEMPERTEC® NQ 0712 Natural Quartz (refer
to Technical Information TI 15 - Alkalinity).

Laying Job interruptions and further coating:


Interruptions of more than 12 hours: Clean the work-
Preparing the substrate
ing area intensively with KEMPERTEC® MEK Cleaning
The substrate must be dry (in concrete, the residual Agent.
moisture in the upper 2 cm must be < 5 %), sound and
PPE
free from any material that would hinder adhesion.
Personal protective equipment should be worn. Clean
Before application of KEMPEROLV 210 Waterproof-
the tools immediately after use with KEMPERTEC®
ing prime using KEMPERTEC® Primer according to the
MEK Cleaning Agent. Clean hands and apply KEMPER
priming recommendations.
SYSTEM skin care cream.
Only apply when the substrate and ambient tempera-
tures are > +5 °C.
Note
Please consider the following technical information:
• TI 03 - layer thicknesses according to guidelines
• TI 15 - alkalinity
• TI 21 - substrate preparation
• TI 23 - solvent-based products

Important notice
The applicable "rules of application" in its current ver-
sion as well as the "standard rules of technology" and
the state of the art for the respective task apply during
waterproofing production. For chemical resistance, see
the Chemical Resistance List A-Z.
The material safety data sheets, identification of the
units, hazard warnings and safety recommendations
on the packs must be observed during transportation,
storage and application. The BG-Chemie technical data
sheets must be observed during application.

Two-component, polyurethane, epoxy and methyl


methacrylate resins react under heat generation. Af-
ter mixing the components, must not remain longer in
the mixing pot than the stated working time. Non-obser-
vance of this time can result in heat and smoke devel-
opment which, in extreme cases, can cause a fire.

Disposal
Komp. A+B flüssig EAK 08 04 09
Komp. A+B ausgehärtet EAK 08 04 10
Katalysatorpulver fest EAK 16 05 08

General information
Changes to the colour caused by weather conditions
or UV rays do not influence the technical parameters.
The times given above are reduced with higher and
increased with lower ambient and substrate tempera-
tures.
KEMPER SYSTEM products must not be mixed with
other manufacturers´ products.
Our technical data sheets / technical information and application in-
structions reflect the current level of knowledge in our company and
the experience with our products. In each case, the new edition su-
persedes the previous technical information and renders it invalid.
It is therefore necessary that you always have to hand the current
code of practise. The latest version can be retrieved from the KEM-
PER SYSTEM Login section. When using our products, a detailed,
object-related and qualified inspection is required in each individual
case in order to determine whether the product and /or application
technology in question meets the specific requirements and purpos-
es. We are liable only for our products being free from faults, and this
only if our relevant product has been used and applied according to
the instructions in our technical data sheets. Correct application of
our products therefore falls entirely within the scope of liability and re-
sponsibility of the user (contractor). Our products are sold exclusively
on the bases of our conditions of sale and delivery.

Issued: Vellmar, 2016-04-11

KEMPER SYSTEM (INDIA) PVT. LTD. Indo-German Technology Park, S.


No. 297, 298, 299, At Post Village - Urawade Tal. Mulshi, Dist. Pune 412 108
Tel.: +91-020-6674 0649 / 50 / 51 / 53 Fax : +91-020-6674 0652 E-mail: info@kemperindia.com
Web: www.kemperindia.com DIN EN ISO 9001:2000 und DIN EN ISO 14001

Вам также может понравиться