weight feeder discharge unit or 282+0.5 x 88+0.5
Coriolis mass flow meter prefeeder.
The control loop ensures that the 288
actual feed rate is matched to the
selected setpoint. Actual feed rate is
acquired with the use of
쮿 Belt speed and belt load
(weighfeeders)
쮿 Loss in weight of material in
hopper per unit time (loss-in-
weight feeders)
max. 10
쮿 Direct mass flow measurement
16
using the Coriolis force (mass flow
meters). 224.5
In addition to the comprehensive
basic equipment, the following
weighing functions are available:
쮿 Weighfeeders
- shift of feeding for point of
discharge Wall Housing
- Automatic belt run monitoring
- Belt influence compensation Selected in
(BIC) accordance
with power and
쮿 Loss-in-Weight Feeders type of frequency
- Adaptive fuzzy disturbance auto converter
elimination system
- Time- or weight-dependent fill
control
- Adaptive control adjustment to
material characteristics
쮿 Coriolis Mass Flow Meters
- Manual and automatic zero
setting
- Prefeeder control
INTECONT® PLUS, FIP 403 - Technical Data Options - Technical Data
Display Clear text fluorescent display, Control cubicles and Control cubicles and device
2 lines with 20 digits each, device frames frames for accommodation of
6 mm character height maximum 2 INTECONT® PLUS
Power supply 24 VDC +30% / -20%
Consumption 20 VA 600 mm x 600 mm x 2000 mm
800 mm x 400 mm x 2000 mm
Ambient conditions Operating temperature
- 40° to + 45°C Wall housing with power Wall housing protected to IP 54
Humidity Class F (DIN 40040) unit and power supply (Nema 4) for power units up to
EMC (OIML, IEC 801, EN 45501) for INTECONT PLUS 3 kW with 230 V / 400 V power
Spark protection (EN 55011, accommodation supply
VDE 871-B) conforms to 500 mm x 300 mm x 600 mm
CE regulations 800 mm x 300 mm x 1000 mm
All parts finish mounted and wired.
Protection Front-of-panel mounting housing Circuit diagrams included in documentation.
Front protected to IP 65
Power supply, 120 V 120 V / 24 V, 1 A (for plug socket)
Inputs Speed (RPM) input
(NAMUR level 0.04 - 2500 Hz) Power supply, 230 V 230 V / 24 V, 1 A (for plug socket)
Load cell input (Rmin 80 Ω) Local control box with ON/OFF switch (IP65) for
Analog input changeover device feeder drive to support
(galvanically non-isolated for and system cable maintenance work.
external setpoint 0...20mA) Complete with changeover
Belt circuit pulse device (control loop) for
(NAMUR level) connection of control unit and
3 digital inputs system cable
(galvanically isolated, safety Analog display 0 -100%, front-of-panel mounted
separated; 24 V, 5 mA release 4 - 20 mA, 96 mm x 24 mm
and taring contacts)
Pulse counter, 6-digit, non-resettable
Outputs Pulse output non-resettable 52 mm x 28 mm
(Totalizing counter 24V/0,1A,
max. 10Hz) Pulse counter, 6-digit, resettable in manual
2 analog outputs resettable 52 mm x 28 mm
(feed rate/load 0/4...20 mA) Event printer 9-dot matrix printer with serial
8 digital outputs interface RS 232 (V 24) and
(Galvanically isolated, safety system cable
separated; 230 V, 8 A ohm./ S5 interface module FSP 0010 - program module for
1 A induct.; limit values, ready, via 3964(R) Siemens S5 (110U / 115U / 135U)
prefeeder, drive, deviation) for serial interfacing
Interfaces Printer RS 232 Data are made available in data module.
3964(R) interface module User prerequisite: CP524 or equivalent
(RS422) S5 interface module FSP 0011 - program module for
MODBUS interface module via MODBUS Siemens S5 (115U / 135U)
(RS422 or RS485) for serial interfacing
Data are made available in data module.
User prerequisite: CP524 or equivalent
BV-D 2062GB5 - 10.0702D - We reserve the right to discontinue or change specifications or designs at any time without notice or obligation.