Вы находитесь на странице: 1из 5

Burner series

Structure

All burner parts are directly installed on the


combustion body. The aluminum alloy casting shell
is equipped with a motor for running the fan and
oil pump. The stainless steel alloy combustion
head and diffusion plate can withstand high
temperatures, up to 1200 degrees Celsius. It is
adjusted so that the fuel can be fully mixed to
achieve full combustion. There is a fire-viewing
mirror in the burner, and an air-conditioning baffle
is connected to the servo motor at the suction port
of the fan. At different load parameters Automatic
control of the amount of fuel and air on the basis
of its, the removable top cover makes circuit
installation and burner maintenance more
convenient

Installation and reasonable application

The burner is suitable for hot water boiler, steam


boiler, hot air heating furnace and various process
heating. The burner can be installed on the boiler
horizontally, vertically upward or vertically
downward. The working area is operated at an
ambient temperature of more than 50 degrees
Celsius and a relative humidity of 80%. The normal
working altitude is 500 meters above sea level.
Power adjustment method

The proportional adjustment burner is equipped


with a servo motor with a conversion time of 30
seconds / 180 °. The proportional adjustment
burner makes stepless adjustment according to
the heater load. During the adjustment, the
different power sections of the burner are adjusted
according to the customer load. Air-fuel ratio.

Flame detector

All types of burners are equipped with flame


detectors. In the gas model, the flame detector
uses ion rods. In the fuel model, photoresistors and
ion rods are used.

controlling device

The control system is built into the burner, and the


control unit can automatically control each
operating stage of the burner. In the event of a
combustion failure, the control system can
automatically stop, load control has been set on
the burner before leaving the factory, and external
load control can be selected according to customer
requirements.
Burner advantages

Integrated design, easy installation


Precise electronic control for optimal combustion
Operational visualization
Flexible communication methods
Simple commissioning and service

program
Obtain relevant boiler data and application data
Boiler power and thermal efficiency or power
requirements for the burner
Boiler back pressure
Use fuel
Fuel pressure to the burner inlet
Burner load adjustment method

Technical Parameters
ZXOQM-80Q-360R ZXOQM-80Q-480R ZXOQM-80Q-600R ZXOQM-80Q-900R
Model
Be Natural gas (if Natural gas (if Natural gas (if Natural gas (if
applicable other gaseous other gaseous other gaseous other gaseous
medium media are used, media are used, media are used, media are used,
the heat output of the heat output of the heat output of the heat output of
the burner may be the burner may be the burner may be the burner may be
appropriately appropriately appropriately appropriately
increased or increased or increased or increased or
decreased decreased decreased decreased

Gas capacity 450(m³)/H 600 (m³)/H 750(m³)/H 1125(m³)/H


(m3 / H
Adjustment 90-450 (m³)/H 120- 150- 225-
range 600(m³)/H 750(m³)/H 1125(m³)/H

Heat 72-3.6 million kcal 96-4.8 million kcal 1.2--6 million kcal 1.8--9 million kcal

control Smooth ratio Smooth ratio Smooth ratio Smooth ratio


method adjustment adjustment adjustment adjustment

Ignition Electronic ignition Electronic ignition Electronic ignition Electronic ignition


method

Power (V) 380 V 380 V 380 V 380 V

Motor 9KW 9KW 15KW 22KW


Power

z weight 190KG 410KG 410KG 530 KG