LC-10A2/10A3/12A2

LC-15A2/20A2/20VM2
SUPPLEMENT

SERVICE MANUAL
S61V6LC-10A2/
SUPPLEMENT

LCD COLOR TELEVISION

LC-10A2, LC-10A3
LC-12A2, LC-15A2
MODELS LC-20A2, LC-20VM2
In the interests of user-safety (Required by safety regulations in some countries ) the set should be restored to its
original condition and only parts identical to those specified should be used.

OUTLINE

This Supplement covers additional information on the lamp errors of the above models. For other
information, refer to the already issued Service Manuals.

LC-10A2 series LC-10A3 series LC-12A2 series LC-15A2 series LC-20A2 series LC-20VM2 series
LC-10A2H-A LC-10A3H-A LC-12A2E LC-15A2E LC-20A2E LC-20VM2A
LC-10A2H-S LC-10A3H-S LC-12A2E(K) LC-15A2H LC-20A2H LC-20VM2E
LC-10A2M-A LC-10A3M-A LC-12A2U LC-15A2E(K) LC-20A2E(K) LC-20VM2 H
LC-10A2M-S LC-10A3M-S LC-15A2M LC-20A2M LC-20VM2E(K)
LC-10A2T(S) LC-10A3U LC-15A2U LC-20A2U LC-20VM2 M
LC-10A2U LC-15A2M X LC-20A2M X LC-20VM2 T
LC-20VM2U
LC-20VM2 X

This document has been published to be used for


SHARP CORPORATION after sales service only.
1The contents are subject to change without notice.
LC-10A2/10A3/12A2
LC-15A2/20A2/20VM2
SUPPLEMENT

The lamp error detection function


» Function
For added safety, these LCD color TV sets are equipped with the lamp error detection function that
automatically turns off the power in case of lamp or lamp circuitry trouble.
If by any chance the lamp or its circuitry malfunctions or if a lamp error is detected for any other reason, the TV
sets behave as follows.
(1) The TV sets can be switched on, but switch themselves off in about 5 seconds.
(The power LED indicator on the front panel turns from green to red.)
(2) If the above phenomenon (1) occurs 5 times in row, the TV sets cannot be switched on.
(The power LED indicator stays in red.)

» Clearing the lamp error count


Take the following procedure to clear the error count.
(1) While holding down the "INPUT SELECT" and "MENU" keys of the set at once, turn on the main power to
enter the inspection process mode. ("K" appears in magenta onscreen.)
(2) Press the "CH –" and "VOL –" keys at once to enter the adjustment process mode.
(3) Press the "MENU" or "CURSOR DN" key to move the cursor to "ERROR NO RESET" position.
(Make sure the ERROR NO RESET entry is of 5 digits.)
(The "ERROR NO RESET" item appears on page 1 of the adjustment process mode.)
(4) Press the "VOL+/–" or "CURSOR LEFT/RIGHT" key to reset the ERROR NO RESET entry to zero.
(5) Turn off the power.
(6) Turn on the power more times to check, if a lamp error is really detected for any other reason.
(7) When you have no trouble, finally turn off the power.
(8) If a lamp error is detected again, check the lamp on its circuitry malfunctions.

SHARP CORPORATION
D JAPAN P JAPAN TQ1155-S AV Systems Group
Jun. 2001 Printed in Japan Quality & Reliability Control Center
NA. KG Yaita, Tochigi 329-2193, Japan