Вы находитесь на странице: 1из 1

Stevenson Construction Information & Materials List;

Note; all steel fixings to be stainless *All construction to comply with NZS 3604:2011 and the NZ Building
90 Code, Specific engineering may apply.
steel if exposed, or fully clad West *All products must have BRANZ approved appraisels, all products and
400 190 4,700 2,400 4,030 190 8,550
enclosed, structural steel to be materials to be installed strictly as per manufacturers specifications and
painted to engineers specifcations 400 190 4,470 5,850 900 190 retaining wall instructions.
window heights 2000mm high
*Timber use to comply with NZS 3602;2003
2,400 90 1,230 1,800 1,000 190 windows unless noted *All lintel and beam sizes to be sized from SG 8 Grade timber unless
otherwise noted, minimum H1.2 treated, Pryda fixings.
G07*
South
950w G/F Stair 15 risers @183,steps 280w *Kitchen layout is indicative only, kitchen manufacturer to supply actual
600 x 1,800 design.

A54
*Smoke detectors fit to comply with A51/F7.

A2
250
*Builder to follow Architectural designer & engineers specifications &
boundary

190
2000h/height drawings.
*All subcontractors to liase with principle contractor in regards to their

190
A1 A1 product & service requirements.

345
A13 190 A13
190

190
190
11
1

10

12

13

14

15
A13 stair A13 *All dimensions to be site checked before construction begins, do not

1,050 950
15 x 184 = 2,755
A A scale off these drawings, if in doubt ask.
Entry store under

2,400 x 2,000
345 2,000
*Drawings are site specific and may be copied for the use of this project

90
2.09x3.9w
2,090

Rumpus room only.


710 c/down

G04
2,690

810 * Do not start any works or order materials until Building Consent is
810
4.28x4.03w approved.
LBW 90x45studs @400crs

4,280
90
Materials List;

4,280
90

* House foundations, 20 series masonry block to perimeter


bench/storage DR wm
190

* G/floor concrete floor 100mm thick 25 Mpa.


510

* General framing; G/floor internal wall framing 2420mm high, all H1.2
190

640

Laundry 90x45 studs SG8 @ max 400crs, 90x45 nogs @ 800crs & 140x45 top

A54
A2
plates.
All Ceilings 2420mm 1st floor 1st/floor wall framing 2720mm high, all H1.2 90x45 studs SG8 @ max
Bulkhead above 760

90
above 400crs, 90x45 nogs @ 800crs & 140x45 top plates.
9,340

9,340
(see joist plan)
101 m2 4/610 2nd/floor wall framing 2420mm high, all H1.2 90x45 studs SG8 @ max

600
90
cpd

Insulated garage door


1FFL=10.065M 600crs, 90x45 nogs @ 800crs & 140x45 top plates, high studs at gable
2.1x4.8w g/door
ends @ 90x45 @300crs

90
900 shower * Claddings;
D001*
6,780

Garage
4,800

1, H3.2 12mm Plywood Sheet with timber H3.2 60x25mm grooved battens
6,270
6,080

glass door & wall @ 400crs vertically, all on 20mm notched cavity battens, with Thermakraft
GFFL=7.30M Bedroom Watergate Plus building underlay on main framing.
900v 2, Espan 340 colorsteel vertical sheeting on 20mm cavity system

4,590
6.08x6.0w 4.59x2.74w
3, Cedar 180mm vertical shiplap cladding on 20mm cavity system

3,900
All ground floor is insulated Bath 4, Honed 200 series masonry blocks in slected locations, basement floor
Ceiling height 2420mm 910c/s room * All joinery aluminium with double glazing (timber jambs) (single glazing
in garage) see schedule min insulation rating to NZBC H1 R value = R
3.9x1.20w 0.26.
* Insulation, floor insulation to comply with NZBC H1,all floors
640

zone 2 TCC= R1.3 min, Concrete Floor = R1.3


* Wall insulation to comply with NZBC H1,all external walls, (garage is
2000h/height 2000h/height insulated also) zone 2 TCC= R2.0 min, use insulation batts R2.2 (90mm
190
190

190
190

190
190
2400h/height 2400h/height thick), strap & line basement, Ceilings, zone 2 TCC = R2.9 min use
opening only insulation batts R3.2.
G00 G01 future services duct G/F roof eve 100mm, ends at masonry wall * Wall linings 10mm gibboard standard, all bathrooms
2,000 x 1,100 1,000 x 2,000 use 10mm aqualine gibboard, all gib level 4 paint finish.
190 1,600 2,000 2,400 90 G03 G02 * Ceilings are 13mm standard gibboard in all areas, (except
400 x 2,400 400 x 1,000 bathroom/ensuite ceilings use 13mm aqualine Gibboard)
East Wet area ensuite bathroom uses 9mm villaboard interior linings
Note; All internal wet area details are to 100 100 Use gib 35mm rondo battens@ 600crs, square stop scotia, except garage
comply with NZBC E3, 90 1,000 190 & cupboards use 40mm bevelled architraves.

North
All windows, joinery and glazing is to be * Exterior ground floor entry doors to be flush level entry, Vantage
1,500 190 6,000
manufactured to comply with NZBC H1
90 2,740 90 1,200 190 residential flush doors.
2011, & to comply with NZ standards, NZS 90 100 100 * On ground deck 1st floor, use Ex100x40 H3.2 pine decking.
1,500 190 6,000 & AS/NZS 2208;1996 also90 170 2,400 170
4223.3.2016 1,000 190 windows
1,500 190 6,081
including NZS3504 1979 & NZ 4211 4,038 190 retaining wall Roof structure;
1,500 190 includes double glazing &10,120
installation, also 190 * Trusses, H1.2 @ 900crs to manufacturers design & installation
NZBC F2/AS1 safety glass areas such as requirements, (to be site measured)
12,000 * Purlins, 70x45mm SG8 Purlins @ 900crs fixed @ trusses @ 900crs, use
any glazing lower than 2000mm height in a
bathroom, All shower/bathroom fixture 2.4Kn fixings to roof, use 1/10g self drilling screw 80mm long.
Note; all external walls to be strap & lined with 30mm polystrene insulation & 10mm plasterboard over on inside face * Soffits, eves varying widths, all lined with 4.5mm hardisoffit, nail fix with
glass to be 6mm thick safety glass min.
40mm nails.
WET AREAS If wet areas are tiled, then waterproofing is * Fascia, Timber ex200x20 h3.2 painted
to be installed over 9mm JH Villaboard on * Spouting, Colorsteel 1/4 round spouting
Note; All internal wet area details are to
walls over concrete floor or on a timber * Downpipes, 80mm diameter round PVC painted
comply with NZBC E3,
floor framing use 20mm H3 structural * Roof underlay, use Thermakraft Covertek 407 reinforced roofing
All windows, joinery and glazing is to be
House Size; manufactured to comply with NZBC H1 plywood flooring, min fall to waste is 1;50, underlay, laid horizontally across roof.
min start step 10mm down then add fall to * Roofs, colorsteel Espan 340 profile.
G Floor area (over frame) = 101m2 2011, & to comply with NZ standards, NZS
4223.3.2016 & AS/NZS 2208;1996 also waste.
1st Floor area (over frame) = 108m2 Minimum waterproofing to all faces within
including NZS3504 1979 & NZ 4211
2nd Floor area (over frame) = 44m2 includes double glazing & installation, also 1500mm of shower head all areas up to
Total floor areas = 253m2 NZBC F2/AS1 safety glass areas such as minimum 1800mm high (however not less Job Title
= 284m2 any glazing lower than 2000mm height in a than 300mm above shower rose) are to be Murray Weatherly Drawing Title
Site size net
Site net coverage based on floor areas
bathroom, All shower/bathroom fixture waterproofed, no matter where tiles are
placed, use Branz approved waterproofing
New Home Architectural Design
glass to be 6mm thick safety glass min.
% 132/284 = 47% membrane system, use Ardex primer &
If wet areas are tiled, then waterproofing is Ardex WPM 002 under tile waterproof
For Ground floor plan
to be installed over 9mm JH Villaboard on
Note; All subcontractors & the builder to read & follow the waterproofing details
walls over concrete floor or on a timber
membrane system. Non slip tiles must go
on floors in wet areas are to comply with
Council = Tauranga City,
Stevenson BUILDING CONSENT Drawing Number Scale @ A3
for the masonry walls attached with these plans, read and follow the Sika
floor framing use 20mm H3 structural NZBC D table 2, 0.1 to 0.4u (co efficent of At
Wind zone = High
Murray W A 06
plywood flooring, min fall to waste is 1;50, friction)
specifications in the Sika manual attached to the architectural specifications Earthquake zone = 1 189A Valley Rd, Drawn 1:100
min start step 10mm down then add fall to
Architectural drawings to be read in conjunction with the engineering plans
waste.
Minimum waterproofing to all faces within
Durability zone= D Mount Maungaui Print Date 1/02/2017 ALL DIMENSIONS TO BE VERIFIED ON SITE
1500mm of shower head all areas up to
minimum 1800mm high (however not less
than 300mm above shower rose) are to be
waterproofed, no matter where tiles are
placed, use Branz approved waterproofing

Вам также может понравиться