Вы находитесь на странице: 1из 4

■ 8 GEPON SFP open slots with

DDMI support
Broadband Passive Optical Networks
■ 1000BASE-PX20 SFP for 20 km Enriching Access Network Services
distance support
■ 2 Gigabit combo + 2 GbE SFP
uplink ports compliant with
Benefits
IEEE 802.3/u/ab
Broadband passive optical network
■ Up to 4 trunking ports for
ZyXEL’s OLT-1308S-22 GEPON system (Optical Line Terminal with 4-port GbE Switch) is located in
uplinks
the operator’s central office, while different types of Optical Network Units (ONU) are located at
■ Support up to 64 ONUs per PON customer premises for FTTB/FTTH connections. The OLT-1308S-22 is connected by a single fiber to
interface an optical power splitter that supplies the optical signal to as many as 512 sets of ONUs (each OLT
■ Support FEC PON port supports up to 64 ONU sets). The OLT-1308S-22 is a mini chassis with a Layer 2 GEPON

■ Support AES or Triple Churning switch featuring 8 GEPON ports (including 3 PON modules), 4 Gigabit uplink ports (2 copper and 2
Encryption combo ports) and one 10/100 Mbps Ethernet port for out-of-band management. For CPE
compatibility, ZyXEL provides several models for different network architecture needs.
■ Support 4 LLIDs per ONU
■ 16K MAC addresses table High bandwidth
■ Management through console, As demand for broadband services such as high-definition TV (HDTV), media-on-demand (MoD),
Telnet, SNMP or Web Voice over IP (VoIP) and online gaming increases continuously, GEPON technology emerges to
management provide astounding 1.25 Gbps bandwidth for both upstream and downstream, giving a 30 Mbps
■ FTP for firmware upgrades bi-directional bandwidth to up to 32 subscribers each. It is a cost-effective access technology with
a reliable and scalable carrier-grade Ethernet infrastructure that really addresses Triply Play service
■ Configuration saving and
needs.
retrieving
■ Overheat detection Cost-effective operations beyond initial fiber deployment
■ LED indicators for link status Construction of the fiber access network is the most labor-intensive task in FTTX projects and thus
■ AC/DC power input for the most expensive. However, PON architecture requires less cost since it requires less fiber. PON
redundancy networks use splitters to allow minimal fiber deployment in local loops. In addition, it requires no
power between CO and network’s termination that lead to lower maintenance costs.
■ PON port redundancy
■ Hot swappable fan module and 20 km long distance coverage
PON modules
On a PON network, subscribers must be within 20 km from the CO, depending on the total number
of splits (distance decreases as splits increase). The OLT-1308S-22 supports a maximum distance of
up to 20 km, and users can choose the different distances ONU type for 20 km deployment to
adapt to the existing network structure.

High scalability and flexibility for easy installation and maintenance


Since ONU can be added to or removed from the network architecture easily and economically,
its great flexibility is perfect for the deployment of different network architectures. FTTH deploys
ONU in residences, while FTTN/FTTC is the combination of fiber and existing copper infrastructure.

OLT-1308S-22 In addition, administrators can upgrade firmware, test loopbacks and detect failures remotely.

8-port GEPON
Optical Line Terminal
with 4-port GbE Switch
OLT-1308S-22
8-port GEPON
Optical Line Terminal
with 4-port GbE Switch

Specifications
System Specifications Network Administration Security Physical Specifications
• User name/password required for • Item dimensions (WxDxH):
Standard Compliance
web/Telnet/local console administrators 440 x 312 x 44 mm (17.32” x 12.28” x 1.73”)
• IEEE 802.3ah
• Two-level security by specific SNMP read/write • Item weight: 4,500 g (9.94 lb.)
• IEEE 802.3ab
community • Packing dimensions (WxDxH):
• IEEE 802.3 Ethernet
• SSH provides network security by encryption 574 x 460 x 161 mm (22.59” x 18.11” x 6.34”)
• IEEE 802.3u Fast Ethernet
administration traffic • Packing weight: 6,000 g (13.26 lb.)
• IEEE 802.3z Gigabit Ethernet
• IEEE 802.3x flow control Network Management
• Web-based management
Environmental Specifications
• IEEE 802.3ad LACP aggregation
• Telnet CLI • Operating temperature: 0ºC to 45ºC
• IEEE 802.1d spanning tree protocol
• IEEE 802.1w rapid spanning tree protocol • SNMP v1, v2c & v3 (32ºF to 113ºF)

• IEEE 802.1Q VLAN tagging • RS-232 local console • Storage temperature: -40ºC to 70ºC

• IEEE 802.1p QoS • Out-of-band management (-40ºF to 158ºF)

• IEEE 802.1X port authentication • NetAtlas PON, EPON manager • Operating humidity: 10% to 90%

• IEEE 802.11 MIB (Non-condensing)


Remote ONU Management through
• Storage humidity: Less than 95% RH
MAC and Packet Buffer OAM Channel
(Non-condensing)
• 16K MAC entries • Firmware upgrade
• Configuration/provisioning
Traffic Management and QoS Certifications
• Status/alarm report
• IEEE 802.1p QoS with 8 priority queues per port • CE-EMC Class A
• Loop-back tests
• IEEE 802.1Q tag-based VLAN • FCC Part15 Class A
• 2K static VLAN, up to 4K dynamic VLAN • CSA-International
Hardware Specifications
• VLAN trunking
• 2 embedded GEPON ports
• Supports to GVRP, automatic VLAN member Product Accessories
• 3 open slots for GEPON modules, each module
registration • OFC-1300: Fan module
supports 2 PON ports
• IGMP v1 & v2 • OLC-1302-22: OLT PON module, each module
• 8 GEPON SFP open slots with DDMI support
User Security and Authentication • 1000BASE-PX20 SFP for distance up to 20 km supports two PON ports

• MAC filtering per port, secure access to • OPA-1300-DC: DC power module to support
• Wavelength: 1.31 um for upstream and 1.49 um
each port -48 V DC
for downstream
• Specific MAC forwarding per port: only specified • 4 GbE uplinks with 2-port RJ-45 1000BASE-T and
MAC addresses can access the network 2 combo ports
(per lock) • One 10/100BASE-T for out-band management
• Limits to the number of MAC address per port • 1 DB9 RS-232 for craft interface
• 802.1X port-based security that prevent • 1 alarm input port
unauthorized client access to the network • Power input:
• Private VLAN provides security and isolation ■
AC: 100 V ~ 240 V
between ports on a switch that prevent users to ■
DC: -48 V
snoop on each others’ traffic • Power consumption:
• VLAN stacking provides CVLAN and SVLAN to ■
AC: 90 Watt max
help separate different user traffic for security ■
DC: 80 Watt max
concern and also enable the flexible VLAN usage • Transceiver:
for users ■
Average output power: 5 dBm

Receiver sensitivity: -30 dBm
Compatible CPE

Specifications
System Specifications Physical Specifications
Wall-Mountable • Item dimensions (WxDxH):

ONU-6100B-22/21, ONU-6040B-22/21:
• 1 GEPON interface with SC type connector
188 x 120 x 30 mm (7.40” x 4.72“ x 1.18”)
(IEEE 802.3ah)

ONU-6040BF-22:
• LAN interface:
ONU-6100B-22/21 181 x 123 x 36 mm (7.13” x 4.84” x 1.42”)

ONU-6100B-22/21: 1 auto MDI/MDI-X
ONU-6040B-22/21
10/100/1000 Mbps port • Item weight:

ONU-6040B-22/21: 4 auto MDI/MDI-X

ONU-6100B-22/21: 300 g (0.66 lb.)

10/100 Mbps ports



ONU-6040B-22/21: 310 g (0.69 lb.)

ONU-6040BF-22: 4 auto MDI/MDI-X

ONU-6040BF-22: 400 g (0.88 lb.)

10/100 Mbps ports • Packing dimensions (WxDxH):

• Wavelength: 1310 nm for upstream & 1490 nm



ONU-6100B-22/21, ONU-6040B-22/21:
ONU-6040BF-22 280 x 150 x 100 mm (11.02” x 5.91” x 3.94”)
for downstram
• Wavelength: 1550 nm for RF overlay

ONU-6040BF-22:

ONU-6100B-22/21 (ONU-6040BF-22) 280 x 232 x 67 mm (11.02” x 9.13” x 2.64”)

ONU-6040B-22/21 • Transceiver (with DDMI support): • Packing weight:

ONU-6040BF-22 ■
Average output power: 2 dBm

ONU-6100B-22/21: 468 g (1.03 lb.)

GEPON Optical Network Unit ■


Receiver sensitivity: -27 dBm

ONU-6040B-22/21: 466 g (1.03 lb.)

• Power: 12 VDC @1.5 A



ONU-6040BF-22: 1,000 g (2.20 lb.)

• RF overlay (ONU-6040BF-22)
• Fiber tray supported (ONU-6040BF-22) Environmental Specifications
• Operating temperature: 0ºC to 45ºC
Network Management
(32ºF to 113ºF)
• Supports OAM or data loop back test
• Storage temperature: -25ºC to 70ºC
• Supports remote control from OAM channel
(-13ºF to 158ºF)
• Loop back tests
• Operating humidity: Less than 95% RH
• Remote firmware upgrade
(Non-condensing)
Support
• Storage humidity: Less than 95% RH
• IEEE 802.3ah (Non-condensing)
• IEEE 802.3/u/ab
• IEEE 802.1X port authentication Certification
• IEEE 802.1Q VLAN
EMC
• IEEE 802.1q VLAN, tag-based and port-based
• FCC Part 15 Class B
• IEEE 802.1p QoS
• CE-EMC Class B
• IGMP snooping
• Broadcast control Safety
• Multicast drop/flooding • CSA-International (ONU-6100B-22/21,

Security Function ONU-6040B-22/21)

• IEEE 802.1X: AES algorithm with 128-bit


encryption key
• Triple Churing Encryption