Вы находитесь на странице: 1из 3

Cracks and a pothole The surface of pavement A huge vertical gap has

have occurred on has been recessed widely occurred behind


pavement. and deeply, and the under abutment due to the
As it obstructs traffic, it surface of slab has been settlement of backfill.
needs early remedial heavily damaged. It has occurred due to the
measure. As the damage of collapse of backfill by
It is necessary to confirm pavement often shows the earthquake. The traffic
the condition of slab. If damage of slab, it is must be stopped
slab has no serious important to check the immediately.
damage, only replace condition of slab under
pavement is enough. pavement damage.
If pavement is replaced
without remedial measure
for slab, it will be damaged
soon.
Remedial measure : Remedial measure: Remedial measure:
Replacement of Replacement of pavement Replacement of
pavement after remedial measure for pavement after remedial
slab measure for backfill
Cracks have occurred Side block of a bearing A large shearing
on the surface of a has been corroded and deformation has occurred
neoprene bearing and has fractured. on a neoprene bearing and
the bearing has Side block has lost the cracks are found.
deformed due to function of preventing It is a type of bearing that is
horizontal load. uplift and transverse composed with interior steel
If cracks occur only on movement. plates and laminated
the surface of cover Remedial measure is rubbers. It is estimated that
rubber and necessary in early stage. plates and Rubber are
deformation is less than separated and the bearing
the ability of shearing has lost its function.
deformation, remedial Remedial measure is
measure is not necessary in early stage.
necessary in early
stage.
If bearing itself has
been damaged, it is
necessary to replace
bearing.
Remedial measure : Remedial measure: Remedial measure:
Replacement of Replacement of bearing Replacement of bearing
bearing with with temporary jacking with temporary jacking up
temporary jacking up up support support
support
Regional peeling (float) Rust depth is "small" and Rust depth is "big".
has occurred, but rust is the thickness reduction is Expansion due to corrosion and the
not confirmed. not confirmed. reduction of plate thickness are
It should be evaluated as Rust is regional and its confirmed.
“(2) Damage of Paint”. area is "small". Heavy corrosion area is limited to the
joint of drainage equipment and is
Its damage rank as “(1) It should be evaluated as
evaluated to “small”.
Corrosion” is “a”. “(2) Damage of Paint” It is necessary to apply remedial
also. It is “c (regional measure early.
peeling)”.
Remedial measure: It is Remedial measure: It is Remedial measure: Replacement
necessary to repair the necessary to repair the of drainage equipment and re-
paint according to paint according to paint
systematic plan. systematic plan.