Вы находитесь на странице: 1из 5

Brocade Knowledge Base - Does MAPS display logical devices in the A... https://kb.brocade.com/kb/index?page=content&id=FAQ4304&cat=DC...

Brocade.com International Welcome Back, Ishan Mahajan My Account Log Out

my home documentation downloads community knowledge base my cases my education product portfolio upgrade

Home| FAQ| Solutions| Knowledge Base Help


Home (index?page=hom e) > FAQ (i ndex?page=content&channel=FAQ) > Product (index?page=content&channel=FAQ&cat=PRODUCT ) > SAN (index?page=content&channel=FAQ&cat=SAN) >
Director/Blade (i ndex?page=content&channel=FAQ&cat=DIRECTOR) > DCX-4S (index?page=content&channel=FAQ&cat=DCX4S) > FAQ Detail

FAQ
Does MAPS display logical devices in the ALL_TARGET_PORTS/ALL_HOSTS_PORTS show outputs?
Back to Printer Rate
Subscribe
(index?page=content& category (index?page=content&
id=FAQ4304&
Friendly this (i ndex?page=subscribe_toggl e& (index?page=subscribe_toggle&
channel=FAQ& (index?page=content& (i ndex?page=content& (#rate) return=content&type=CONTENT& return=content&type=CONTENT &
cat=DCX4S) channel=FAQ& pmv=print& id=FAQ4304&pmv=print& Page id=FAQ4304&viewlocale=null) id=FAQ4304&viewlocale=nul l)
impressions=false) (#rate)
cat=DCX4S) im pressi ons=fal se)

FAQ ID: FAQ4304 Categories: DCX (index?page=content&channel=FAQ&cat=DCX)


Updated: 08/11/2014 FCOE10-24 CEE/FCoE blade (i ndex?page=content&
channel=FAQ&cat=FCOE1024_CEEFCOE_BLADE)

NOS (index?page=content&channel=FAQ&cat=NOS)
DCX-4S (index?page=content&channel=FAQ&cat=DCX4S)
FCOE10 (i ndex?page=content&channel=FAQ&cat=FCOE10)
FC10-6 (index?page=content&channel=FAQ&cat=FC106)
FOS (index?page=content&channel=FAQ&cat=FOS)

Context
When configuring MAPS logical groups performing the MAPS command logicalgroup --show
ALL_TARGET_PORTS/ALL_HOST_PORTS MAPS will only display physical devices in the output.
Example:
Only the 4 FC targets on blade 9 are registering device type and are being seen within MAPS
The devices connected to the FCoE10-24 are:
DCX8510-8
Slot1/port 4 - Windows 2012/554FLR
Slot1/port 5 - Windows 2012/CN1100E
Slot1/port 6 - Windows 2008 R2/ CN1100E
Slot1/port 7 - Windows 2008 R2/554FLR
Slot1/port 8 - P6350 FCoE
Slot1/port 9- P7450 FCoE
Slot1/port 10- P9500 FCoE
Slot1/port 11- P10000 FCoE
Slot1/port 20 - RHEL6.5/554FLR
Slot1/port 21 - RHEL6.5/CN1100E
Slot1/port 22 - VMWare5.5 U1/CN1100E
Slot1/port 22 - VMWare5.5 U1/554FLR
DCX8510-8:FID128:root> nsshow -t
{
Type Pid COS PortName NodeName TTL(sec)
N 020400; 3;20:04:00:05:1e:43:a8:00;10:00:00:05:1e:43:a8:00; na
Fabric Port Name: 20:04:00:05:1e:43:a8:00
Permanent Port Name: 20:04:00:05:1e:43:a8:00
Device type: Physical Unknown(initiator/target)

Port Index: 4
Share Area: No
Device Shared in Other AD: No
Redirect: No
Partial: No
LSAN: No
N 020401; 3;10:00:e8:39:35:c5:17:c5;20:00:e8:39:35:c5:17:c5; na
FC4s: IPFC FCP
PortSymb: [34] "Emulex PPN-10:00:E8:39:35:C5:17:C5"
NodeSymb: [61] "Emulex 554FLR-SFP+ FV4.9.416.0 DV2.76.003.001 WIN-27BQF9T52R4"
Fabric Port Name: 20:04:00:05:1e:43:a8:00
Permanent Port Name: 20:04:00:05:1e:43:a8:00
Device type: FCoE Unknown(initiator/target)
Port Index: 4
Share Area: No
Device Shared in Other AD: No
Redirect: No
Partial: No
LSAN: No
N 020600; 3;20:06:00:05:1e:43:a8:00;10:00:00:05:1e:43:a8:00; na
Fabric Port Name: 20:06:00:05:1e:43:a8:00
Permanent Port Name: 20:06:00:05:1e:43:a8:00
Device type: Physical Unknown(initiator/target)

Port Index: 6
Share Area: No
Device Shared in Other AD: No

1 of 5 9/28/2015 6:38 PM
Brocade Knowledge Base - Does MAPS display logical devices in the A... https://kb.brocade.com/kb/index?page=content&id=FAQ4304&cat=DC...

Redirect: No
Partial: No
LSAN: No
N 020601; 3;10:00:e4:11:5b:62:d5:a1;20:00:e4:11:5b:62:d5:a1; na
FC4s: IPFC FCP
PortSymb: [34] "Emulex PPN-10:00:E4:11:5B:62:D5:A1"
NodeSymb: [49] "Emulex CN1100E FV4.9.416.0 DV2.76.003.001 TACOMA7"
Fabric Port Name: 20:06:00:05:1e:43:a8:00
Permanent Port Name: 20:06:00:05:1e:43:a8:00
Device type: FCoE Unknown(initiator/target)
Port Index: 6
Share Area: No
Device Shared in Other AD: No
Redirect: No
Partial: No
LSAN: No
N 020700; 3;20:07:00:05:1e:43:a8:00;10:00:00:05:1e:43:a8:00; na
Fabric Port Name: 20:07:00:05:1e:43:a8:00
Permanent Port Name: 20:07:00:05:1e:43:a8:00
Device type: Physical Unknown(initiator/target)

Port Index: 7
Share Area: No
Device Shared in Other AD: No
Redirect: No
Partial: No
LSAN: No
N 020701; 3;10:00:3c:d9:2b:f6:78:7d;20:00:3c:d9:2b:f6:78:7d; na
FC4s: IPFC FCP
PortSymb: [34] "Emulex PPN-10:00:3C:D9:2B:F6:78:7D"
NodeSymb: [53] "Emulex 554FLR-SFP+ FV4.9.416.0 DV2.76.003.001 TACOMA7"
Fabric Port Name: 20:07:00:05:1e:43:a8:00
Permanent Port Name: 20:07:00:05:1e:43:a8:00
Device type: FCoE Unknown(initiator/target)
Port Index: 7
Share Area: No
Device Shared in Other AD: No
Redirect: No
Partial: No
LSAN: No
N 020800; 3;20:08:00:05:1e:43:a8:00;10:00:00:05:1e:43:a8:00; na
Fabric Port Name: 20:08:00:05:1e:43:a8:00
Permanent Port Name: 20:08:00:05:1e:43:a8:00
Device type: Physical Unknown(initiator/target)
Port Index: 8
Share Area: No
Device Shared in Other AD: No
Redirect: No
Partial: No
LSAN: No
N 020801; 3;21:00:d4:85:64:93:4d:1c;20:00:d4:85:64:93:4d:1c; na
FC4s: FCP
NodeSymb: [30] "HP StorageWorks MEZ75-3.2.2.9."
Fabric Port Name: 20:08:00:05:1e:43:a8:00
Permanent Port Name: 20:08:00:05:1e:43:a8:00
Device type: FCoE Initiator
Port Index: 8
Share Area: No
Device Shared in Other AD: No
Redirect: No
Partial: No
LSAN: Yes
N 020802; 3;21:05:d4:85:64:93:4d:1c;20:05:d4:85:64:93:4d:1c; na
FC4s: FCP
NodeSymb: [30] "HP StorageWorks MEZ75-3.2.2.9."
Fabric Port Name: 20:08:00:05:1e:43:a8:00
Permanent Port Name: 20:08:00:05:1e:43:a8:00
Device type: FCoE Target
Port Index: 8
Share Area: No
Device Shared in Other AD: No
Redirect: No
Partial: No
LSAN: Yes
N 020803; 3;21:04:d4:85:64:93:4d:1c;20:04:d4:85:64:93:4d:1c; na
FC4s: FCP
NodeSymb: [30] "HP StorageWorks MEZ75-3.2.2.9."
Fabric Port Name: 20:08:00:05:1e:43:a8:00
Permanent Port Name: 20:08:00:05:1e:43:a8:00
Device type: FCoE Target
Port Index: 8
Share Area: No
Device Shared in Other AD: No
Redirect: No
Partial: No
LSAN: Yes
N 020900; 3;20:09:00:05:1e:43:a8:00;10:00:00:05:1e:43:a8:00; na
Fabric Port Name: 20:09:00:05:1e:43:a8:00
Permanent Port Name: 20:09:00:05:1e:43:a8:00

2 of 5 9/28/2015 6:38 PM
Brocade Knowledge Base - Does MAPS display logical devices in the A... https://kb.brocade.com/kb/index?page=content&id=FAQ4304&cat=DC...

Device type: Physical Unknown(initiator/target)


Port Index: 9
Share Area: No
Device Shared in Other AD: No
Redirect: No
Partial: No
LSAN: No
N 020901; 3;20:21:00:02:ac:00:87:18;2f:f7:00:02:ac:00:87:18; na
FC4s: FCP
PortSymb: [25] "1634584 - 0:2:1 - QLE8242"
NodeSymb: [32] "HP_3PAR 7450 - 1634584 - fw:3130"
Fabric Port Name: 20:09:00:05:1e:43:a8:00
Permanent Port Name: 20:09:00:05:1e:43:a8:00
Device type: FCoE Unknown(initiator/target)
Port Index: 9
Share Area: No
Device Shared in Other AD: No
Redirect: No
Partial: No
LSAN: Yes
N 020a00; 3;20:0a:00:05:1e:43:a8:00;10:00:00:05:1e:43:a8:00; na
Fabric Port Name: 20:0a:00:05:1e:43:a8:00
Permanent Port Name: 20:0a:00:05:1e:43:a8:00
Device type: Physical Unknown(initiator/target)

Port Index: 10
Share Area: No
Device Shared in Other AD: No
Redirect: No
Partial: No
LSAN: No
N 020a01; 3;50:06:0e:80:06:cf:33:02;50:06:0e:80:06:cf:33:02; na
FC4s: FCP
Fabric Port Name: 20:0a:00:05:1e:43:a8:00
Permanent Port Name: 20:0a:00:05:1e:43:a8:00
Device type: FCoE Unknown(initiator/target)
Port Index: 10
Share Area: No
Device Shared in Other AD: No
Redirect: No
Partial: No
LSAN: Yes
N 020b00; 3;20:0b:00:05:1e:43:a8:00;10:00:00:05:1e:43:a8:00; na
Fabric Port Name: 20:0b:00:05:1e:43:a8:00
Permanent Port Name: 20:0b:00:05:1e:43:a8:00
Device type: Physical Unknown(initiator/target)
Port Index: 11
Share Area: No
Device Shared in Other AD: No
Redirect: No
Partial: No
LSAN: No
N 020b01; 3;21:51:00:02:ac:00:0e:41;2f:f7:00:02:ac:00:0e:41; na
FC4s: FCP
PortSymb: [25] "1403649 - 1:5:1 - QLE8242"
NodeSymb: [39] "HP_3PAR InServ V400 - 1403649 - fw:3130"
Fabric Port Name: 20:0b:00:05:1e:43:a8:00
Permanent Port Name: 20:0b:00:05:1e:43:a8:00
Device type: FCoE Unknown(initiator/target)
Port Index: 11
Share Area: No
Device Shared in Other AD: No
Redirect: No
Partial: No
LSAN: Yes
N 024900; 3;50:06:0e:80:06:cf:33:56;50:06:0e:80:06:cf:33:56; na
FC4s: FCP [HP DISK-SUBSYSTEM 7006]
Fabric Port Name: 20:49:00:05:1e:43:a8:00
Permanent Port Name: 50:06:0e:80:06:cf:33:56
Device type: Physical Target

Port Index: 73
Share Area: No
Device Shared in Other AD: No
Redirect: No
Partial: No
LSAN: Yes
N 024a00; 3;21:12:00:02:ac:00:87:18;2f:f7:00:02:ac:00:87:18; na
FC4s: FCP
PortSymb: [26] "1634584 - 1:1:2 - LPe12002"
NodeSymb: [32] "HP_3PAR 7450 - 1634584 - fw:3130"
Fabric Port Name: 20:4a:00:05:1e:43:a8:00
Permanent Port Name: 21:12:00:02:ac:00:87:18
Device type: Physical Target

Port Index: 74
Share Area: No
Device Shared in Other AD: No
Redirect: No

3 of 5 9/28/2015 6:38 PM
Brocade Knowledge Base - Does MAPS display logical devices in the A... https://kb.brocade.com/kb/index?page=content&id=FAQ4304&cat=DC...

Partial: No
LSAN: Yes
N 024b00; 3;20:21:00:02:ac:00:0e:41;2f:f7:00:02:ac:00:0e:41; na
FC4s: FCP
PortSymb: [26] "1403649 - 0:2:1 - LPe12004"
NodeSymb: [39] "HP_3PAR InServ V400 - 1403649 - fw:3130"
Fabric Port Name: 20:4b:00:05:1e:43:a8:00
Permanent Port Name: 20:21:00:02:ac:00:0e:41
Device type: Physical Target

Port Index: 75
Share Area: No
Device Shared in Other AD: No
Redirect: No
Partial: No
LSAN: Yes
N 024c00; 3;50:01:43:80:11:39:39:ee;50:01:43:80:11:39:39:e0; na
FC4s: FCP
PortSymb: [28] "HSV340 - P6350-39E0 - CR229C"
Fabric Port Name: 20:4c:00:05:1e:43:a8:00
Permanent Port Name: 50:01:43:80:11:39:39:ee
Device type: Physical Target
Port Index: 76
Share Area: No
Device Shared in Other AD: No
Redirect: No
Partial: No
LSAN: Yes
N 028400; 3;20:84:00:05:1e:43:a8:00;10:00:00:05:1e:43:a8:00; na
Fabric Port Name: 20:84:00:05:1e:43:a8:00
Permanent Port Name: 20:84:00:05:1e:43:a8:00
Device type: Physical Unknown(initiator/target)
Port Index: 132
Share Area: No
Device Shared in Other AD: No
Redirect: No
Partial: No
LSAN: No
N 028401; 3;10:00:80:c1:6e:80:c1:11;20:00:80:c1:6e:80:c1:11; na
FC4s: FCP
PortSymb: [34] "Emulex PPN-10:00:80:c1:6e:80:c1:11"
NodeSymb: [45] "Emulex 554FLR-SFP+ FV4.9.311.20 DV8.3.7.21.4p"
Fabric Port Name: 20:84:00:05:1e:43:a8:00
Permanent Port Name: 20:84:00:05:1e:43:a8:00
Device type: FCoE Unknown(initiator/target)
Port Index: 132
Share Area: No
Device Shared in Other AD: No
Redirect: No
Partial: No
LSAN: No
N 028500; 3;20:85:00:05:1e:43:a8:00;10:00:00:05:1e:43:a8:00; na
Fabric Port Name: 20:85:00:05:1e:43:a8:00
Permanent Port Name: 20:85:00:05:1e:43:a8:00
Device type: Physical Unknown(initiator/target)
Port Index: 133
Share Area: No
Device Shared in Other AD: No
Redirect: No
Partial: No
LSAN: No
N 028501; 3;10:00:e4:11:5b:62:40:31;20:00:e4:11:5b:62:40:31; na
FC4s: FCP
PortSymb: [34] "Emulex PPN-10:00:e4:11:5b:62:40:31"
NodeSymb: [41] "Emulex CN1100E FV4.9.311.20 DV8.3.7.21.4p"
Fabric Port Name: 20:85:00:05:1e:43:a8:00
Permanent Port Name: 20:85:00:05:1e:43:a8:00
Device type: FCoE Unknown(initiator/target)
Port Index: 133
Share Area: No
Device Shared in Other AD: No
Redirect: No
Partial: No
LSAN: No
N 028600; 3;20:86:00:05:1e:43:a8:00;10:00:00:05:1e:43:a8:00; na
Fabric Port Name: 20:86:00:05:1e:43:a8:00
Permanent Port Name: 20:86:00:05:1e:43:a8:00
Device type: Physical Unknown(initiator/target)
Port Index: 134
Share Area: No
Device Shared in Other AD: No
Redirect: No
Partial: No
LSAN: No
N 028601; 3;10:00:98:4b:e1:5b:77:51;20:00:98:4b:e1:5b:77:51; na
Fabric Port Name: 20:86:00:05:1e:43:a8:00
Permanent Port Name: 20:86:00:05:1e:43:a8:00
Device type: FCoE Unknown(initiator/target)
Port Index: 134

4 of 5 9/28/2015 6:38 PM
Brocade Knowledge Base - Does MAPS display logical devices in the A... https://kb.brocade.com/kb/index?page=content&id=FAQ4304&cat=DC...

Share Area: No
Device Shared in Other AD: No
Redirect: No
Partial: No

LSAN: No
The Local Name Server has 26 entries }
DCX8510-8:FID128:root> logicalgroup --show ALL_HOST_PORTS
--------------------------------------------------------------------------------------------------------------
Group Name |Predefined |Type |Member Count |Members
--------------------------------------------------------------------------------------------------------------
ALL_HOST_PORTS |Yes |Port |0 |
DCX8510-8:FID128:root> logicalgroup --show ALL_TARGET_PORTS
--------------------------------------------------------------------------------------------------------------
Group Name |Predefined |Type |Member Count |Members
--------------------------------------------------------------------------------------------------------------
ALL_TARGET_PORTS |Yes |Port |4 |9/9-12
Answer
In FOS 7.2.x and 7.3.0 releases, the MAPS logicalgroup –show command will only poll the name server for
physical devices. This means that logical devices, such as FCOE hosts/target, will not be able to be discovered in
a MAPS logicalgroup command outputs.
Internal Comments
Engineering is currently investigating enhancements to the MAPS utility to allow logical devices to be discovered
the same way physical devices are in the logicalgroup command outputs. These enhancements, if they are
possible, will be in a future release. Setting review period 1 year out and at that time this doc will most likely need
to be updated with the version that supports the logical device discovery in the logicalgroup command outputs.
Disclaimer
These documents are provided "as is" and without any warranty of any kind, expressed or implied, including, without limitation, any warranty of
non-infringement, merchantability, or fitness for a particular purpose. All warranties are expressly disclaimed. User assumes the full risk of using these
instructions. In no event shall Brocade be liable for any actual, direct, indirect, punitive, or consequential damages arising from such use, even if advised of
the possibility of such damages.

Rate this Page


Please take a moment to complete this form to help us better serve you.
Bad
Poor
Please rate this article Good
Very Good
Excellent

Your response will be used to improve our document content. Requests for assistance should be submitted
through your normal support channel as we cannot respond from this site.

RSS Feeds Contact Us Site Map Privacy Legal Investor Relations

5 of 5 9/28/2015 6:38 PM

Вам также может понравиться