Вы находитесь на странице: 1из 2

MAX Wireless Relay

www.max.us.com

The MAX wireless relay is designed to wirelessly transmit and receive a


signal from the gate operator to control desired functions remotely.
The 2 individual relays function independently from each other allowing
2 different applications to be used and they can vary greatly. Almost any
device with a dry contact input (switch ON or OFF) can be used. A few
examples are:
• Opening Device
• Gate Tamper monitoring and controlling
• Monitor the gate Open and Closed positions
• Turn on safety devices when the gate opens
• Operate with an existing alarm system
The 900 MHz signal is long range (up to a mile away) and robust,
making the signal almost immune to any interference.

relay description

900MHz Robust Signal


Up to 1 Mile apart using Line-of-Sight
Signal QUALITY: INPUT 2 activates RELAY 2
4 - Excellent
RANGE TEST: 3-4 - Good INPUT 2 activates RELAY 2
Channels MUST match 2-3 - Poor Mounting Hole
on both units.
Must remain OFF during
normal operation.
1 1
CHANNEL: OFF ON OFF ON
ONLY use channels 0 (0-6) (0-6)
CHANNEL RANGE TEST Signal QUALITY CHANNEL RANGE TEST Signal QUALITY
thru 6.
Channels MUST match
on both units.
RELAY 1-NC RELAY 2-NC RELAY 1-NC RELAY 2-NC

RELAY 1-C RELAYS RELAY 2-C RELAY 1-C RELAYS RELAY 2-C

RELAY 1-NO RELAY 2-NO RELAY 1-NO RELAY 2-NO

GND GND GND GND


INPUTS INPUTS
INPUT 1 INPUT 2 INPUT 1 INPUT 2

POWER RS-485 Ground POWER RS-485 Ground


12-16 VAC/DC + - GND 12-16 VAC/DC + - GND

Wire Input Wire Input: DO NOT drill holes in box


Ground Wire
GROUND Connection:
All inputs are lightning protected
12 VDC Power when box is properly grounded.
INPUT 1 activates RELAY 1 12 VDC Power:
Power separately using supplied transformer.
INPUT 1 activates RELAY 1 Polarity does not matter.
DO NOT power from Matrix 1.

Maximum Controls LLC. • 949.699.0220 • 10530 Lawson River Ave, Fountain Valley, CA 92708
MAX Wireless Relay
www.max.us.com

Opening Devices
wireless opening options
Emergency
Dry Contact (N.O.)
Gate Operator Matrix 1 See other side for more information
MATRIX 1

INPUT 1 (N.O.)
BATTERY PRIMARY
BACK-UP MODE
LEAVE
CLOSED
GATE
MAGLOCK
about setup and testing wireless relays.
OPEN OPEN DELAY MAG
Keypad
MADE in USA LEAVE OPEN
OPEN 1 TIME LEFT RIGHT OFF 1.5Sec 2Sec LOCK
COM
NC
AUTOMATIC OPEN/CLOSE CONTROLS
ANTI Tamper NO
TAILGATE EXIT CENTER SAFETY GATE COM

GND
TAMPER
EXIT ON OFF GND
Tamper IN

CENTER
Opening device will activate Relay 1.
PHOTOCELL
Card Reader
SAFETY UL EDGE 1
MIN MAX
OFF
ENTRAP EDGE 2
CLOSE TIMER
ID PLUG
PARTIAL MOTOR MOTION ERROR
OPEN
ID
PLUG UL ALARM 12V
ALARM RET
POSITION
RECORDER
OPEN STOP CLOSE RESET
GND Key Switch
MAX REVERSE SENSITIVITY
12VDC
GND OBD PORT
BLACK BOX
GATE SPEED MOTOR OVERLOAD
GATE OPEN
RELAY 2: Available for another use.
MIN NO LIMIT SWITCH /
24VDC STATUS COM
GND
MAX
CLAMP SLIPPING
RELAY
CLOSE 1-NC

LIMIT
SWITCH BATTERYRELAY 1-C
ON-LINE IN USE
GATE DISABLE
KEYPAD / RDR

RELAY 1-NO
PHOTOCELL
RADIO GND

MOTOR
RADIO SIG.

MAX OPEN
FIRE DEPT

ON-LINE POWER
STRIKE

PRIMARY SEC
GND
CLOSE

Telephone
OPEN
STOP
GND

GATE GATE
COM
GND

GND

GND

GND

GND
24V
GND

GND
(+)

(+)
(-)

(-)

INPUT 1
Entry
GND 12 VDC Power
12 VDC Power
STRIKE (N.O.) DO NOT power from Matrix 1.
Separate power for
Opening device if needed.

wireless gate tamper


The GATE TAMPER can be used for various functions such as turning a warning light, siren or camera on when the gate is tampered with (Vandalized
Gate). The gate operator defines a “Vandalized Gate” as UNAUTHORIZED movement of the gate. This can occur if the chain is dropped and gate is
manually moved from the closed position or the gate is forced open from the closed position without authorization.

Gate Operator Matrix 1


MATRIX 1 BATTERY
BACK-UP MODE
PRIMARY
GATE
Security Devices
LEAVE MAGLOCK
CLOSED
MADE in USA LEAVE OPEN OPEN OPEN DELAY MAG
LEFT RIGHT

Dry Contact (N.O.)


OPEN 1 TIME OFF 1.5Sec 2Sec LOCK
COM
NC
Existing
AUTOMATIC OPEN/CLOSE CONTROLS Building
ANTI
TAILGATE EXIT CENTER SAFETY GATE
Tamper NO
COM Tampering with gate will activate Relay 1. Alarm
EXIT ON OFF
TAMPER GND
Tamper IN
System
Relay 1 (N.O.)

CENTER
PHOTOCELL

SAFETY UL EDGE 1
MIN MAX
OFF
ENTRAP EDGE 2
CLOSE TIMER
ID PLUG
Com

PARTIAL MOTOR MOTION ERROR


OPEN
Tamper (N.O.)

ID
PLUG UL ALARM 12V
ALARM RET RELAY 2: Available for another use.
POSITION
RECORDER
OPEN STOP CLOSE RESET
GND Siren
MAX
RELAY 1-NC
REVERSE SENSITIVITY
12VDC
GND OBD PORT GATE SPEED MOTOR OVERLOAD
Com

BLACK BOX GATE OPEN


24VDC
MIN NO LIMIT SWITCH /
CLAMP SLIPPING STATUS COM RELAY 1-C
MAX
GND CLOSE
RELAY 1-NO
LIMIT BATTERY
SWITCH
ON-LINE IN USE GND
GATE DISABLE
KEYPAD / RDR

PHOTOCELL
RADIO GND

MOTOR
RADIO SIG.

MAX OPEN
FIRE DEPT

ON-LINE POWER
INPUT 1
STRIKE

PRIMARY SEC
Warning
CLOSE
OPEN
STOP
GND

GATE GATE
COM
GND

GND

GND

GND

GND
24V
GND

GND
(+)

(+)
(-)

(-)

Light

12 VDC Power
12 VDC Power
Additional Motion Sensor DO NOT power from Matrix 1.
Separate power for
Tamper NO security device if needed.
GATE COM Security
TAMPER Camera
GND Motion Sensor
Tamper IN
See other side for more information
If a motion sensor is added to the Tamper IN input, when about setup and testing wireless relays.
the motion sensor gets triggered, security device that is
wired to Tamper NO - RELAY 1 will activate (see above).

Maximum Controls LLC. • 949.699.0220 • 10530 Lawson River Ave, Fountain Valley, CA 92708 Rev 2