Вы находитесь на странице: 1из 5

S.No.

Topic to be CO PO ICT Proposed Date of Signature


covered Covered Used Lecture/Week Lecture
(Yes/No) Taken
1. Introduction CO-1 PO-1,2,3,5,6,812 (Unit-1)I
To Subject &
Overview
2. Primary and CO-1 PO-1,2,3,5,6,812 (Unit-1)I
backup
protection
3. Faults, CO-1 PO-1,2,3,5,6,812 (Unit-1)I
overloads and
switching over
currents
4. Functional CO-1 PO-1,2,3,5,6,812 (Unit-1)I
characteristics
of a relay,
zone of
protection
5. Current CO-1 PO-1,2,3,5,6,812 (Unit-1)I
transformer
construction,
measurement
& protective
CTs
6. Type of CO-1 PO-1,2,3,5,6,812 (Unit-1)I I
potential
transformers.
7. Steady state CO-1 PO-1,2,3,5,6,812 (Unit-1)I I
ratio and phase
angle errors in
CTs and PTs
8. Transient CO-1 PO-1,2,3,5,6,812 (Unit-1)I I
errors in CT
and CVT/
Assignment 1
9. HRC fuse and CO-2 PO-1,2,5,12 (Unit-2)I I
thermal relay
10. Overcurrent CO-2 PO-1,2,5,12 (Unit-2)I I
relays–
instantaneous,
definite time,
inverse time
S.No. Topic to be CO PO ICT Proposed Date of Signature
covered Covered Used Lecture/Week Lecture
(Yes/No) Taken
11. Induction disc CO-2 PO-1,2,5,12 (Unit-2)I I I
type relay.
12. Directional CO-2 PO-1,2,5,12 (Unit-2)I I I
overcurrent
relay, 30, 60
and 90
connections
13. Earth fault CO-2 PO-1,2,5,12 (Unit-2)I I I
relay
14. Brief CO-2 PO-1,2,5,12 (Unit-2)I I I
description of
overcurrent
protective
schemes for a
feeder
15. Parallel CO-2 PO-1,2,5,12 (Unit-2)I I I
feeders and
ring mains
16. MCQ’s and CO-2 PO-1,2,5,12 (Unit-2)I V
numerical
discussion/
Assignment 2
17. Introduction CO-3 PO- (Unit-3)I V
to generator 1,2,3,4,5,7,8,12
protection
schemes
18. Stator CO-3 PO- (Unit-3)I V
protection– 1,2,3,4,5,7,8,12
differential,
percentage
differential
protection
19. Protection CO-3 PO- (Unit-3)I V
against stator 1,2,3,4,5,7,8,12
inter-turn
faults
20. stator CO-3 PO- (Unit-3)I V
overheating 1,2,3,4,5,7,8,12
protection
S.No. Topic to be CO PO ICT Proposed Date of Signature
covered Covered Used Lecture/Week Lecture
(Yes/No) Taken
21. Rotor CO-3 PO-1,2,3,4,5,7,8,12 (Unit-3) V
protection-
against
excitation
failure
22. Rotor CO-3 PO-1,2,3,4,5,7,8,12 (Unit-3) V
protection-
against prime
mover failure
23. Field earth CO-3 PO-1,2,3,4,5,7,8,12 (Unit-3) V
fault and
unbalanced
stator currents
24. Numerical CO-3 PO-1,2,3,4,5,7,8,12 (Unit-3) V
discussion/
Assignment-3
25. Introduction CO-4 PO- (Unit-4) V
to transformer 1,2,3,4,5,6,7,8,11,12
and bus bar
protection
26. Percentage CO-4 PO- (Unit-4)VI
differential 1,2,3,4,5,6,7,8,11,12
protection
27. magnetizing CO-4 PO- (Unit-4)VI
inrush current 1,2,3,4,5,6,7,8,11,12
28. percentage CO-4 PO- (Unit-4)VI
differential 1,2,3,4,5,6,7,8,11,12
relay with
harmonic
restraint
29. Buchholz CO-4 PO- (Unit-4)VI
relay 1,2,3,4,5,6,7,8,11,12
30. Differential CO-4 PO- (Unit-4)VI
protection of 1,2,3,4,5,6,7,8,11,12
generator
transfer unit.
31. Bus bar CO-4 PO- (Unit-4)VII
Differential 1,2,3,4,5,6,7,8,11,12
protection
S.No. Topic to be CO PO ICT Proposed Date of Signature
covered Covered Used Lecture/Week Lecture
(Yes/No) Taken
32. High CO-4 PO- (Unit-4)VII
impedance 1,2,3,4,5,6,7,8,11,12
relay scheme,
frame leakage
protection/
Assignment 4
33. Introduction CO-5 PO- (Unit-5)VII
to distance 1,2,3,4,5,6,7,8,9,10,12
protection.
Construction,
operating
principle and
characteristics
34. Effect of arc CO-5 PO- (Unit-5)VII
resistance. 1,2,3,4,5,6,7,8,9,10,12
Induction cup
type
reactance and
mho relays,
Three stepped
distance
protection of
transmission
line
35. Comparison CO-5 PO- (Unit-5)VII
between 1,2,3,4,5,6,7,8,9,10,12
impedance,
reactance and
mho relays.
36. Introduction CO-5 PO- (Unit-5)VIII
to various 1,2,3,4,5,6,7,8,9,10,12
faults and
abnormal
operating
conditions
S.No Topic to be CO PO ICT Proposed Date of Signatu
. covered Covered Used Lecture/Week Lectur re
(Yes/No) e
Taken
37. unbalance CO-5 PO- (Unit-5)VIII
supply 1,2,3,4,5,6,7,8,9,
voltage and 10,12
single
phasing.
Introduction
to protection
of induction
motors
38. Working of CO-5 PO- (Unit-5)VIII
overcurrent, 1,2,3,4,5,6,7,8,9,
percentage 10,12
differential
39. Idea of earth CO-5 PO- (Unit-5)VIII
fault and 1,2,3,4,5,6,7,8,9,
negative 10,12
sequence
voltage relays
40. Numerical CO-5 PO- (Unit-5)VIII
discussion/ 1,2,3,4,5,6,7,8,9,
Assignment- 10,12
5

Вам также может понравиться