1a
ASCE 7-10 Load Combination Equation Permutations Sample Data and Results: ASCE 7-10
a
Note that the load factor for L in LRFD equations (3), (4), and (5) is permitted d Note that the load factor for H is 0.6 when it resists the primary
to equal 0.5 for occupancies in which the unit live load is less than or equal to load (i.e. has opposite sign) and is permanent. If H resists the
100 psf, except for garages or areas occupied as places of public assembly. primary load and is not permanent then use a load factor of 0.
Otherwise the load factor for L equals 1.0. The load factor for H is 1.0 when it contributes to the primary
load (i.e. has the same sign)
b
Note that the load factor for H is 0.9 when it resists the primary load (i.e. has e
The coefficient on E is 0 in equations 5 and 6b whenever Fa is
opposite sign) and is permanent. If H resists the primary load and is not permanent
then use a a load factor of 0. The load factor for H is 1.6 when it contributes to the included. The coefficient on Fa is 0.75 when the structure is in a
primary load (i.e. has the same sign) noncoastal-A zone and Fa is non-zero. Otherwise the coefficient
on Fa is 1.5.
c
The coefficient on W is 0.5 and 1.0 on F a when the structure is in a noncoastal-A zone
with Fa being non-zero. Otherwise the coefficient on W is 1.0 and 2.0 on F a.
aximum heights