Вы находитесь на странице: 1из 31

Patient Monitor

Service Manual

Shenzhen Biocare Electronics Co.,Ltd


Content

Content
Chapter 1 Introduction ............................................................................................................................... 1

Chapter 2 Interface ..................................................................................................................................... 2

2.1 System Structure Diagram ................................................................................................................... 2


2.2 Socket Interface .................................................................................................................................... 2
2.3 FY0805 Board Interface ....................................................................................................................... 3
2.4 Keyboard Interface ............................................................................................................................... 4
2.5 Power Board Interface.......................................................................................................................... 4

Chapter 3 Disassembly Guide .................................................................................................................... 5

3.1 System Overview ................................................................................................................................. 5


3.2 Front Case ............................................................................................................................................ 6
3.3 Rear Case ............................................................................................................................................. 6
3.4 Disassembly Procedure ...................................................................................................................... 7
3.5 Cable Specification .............................................................................................................................. 8
3.6 BOM List ........................................................................................................................................... 13

Chapter 4 Troubleshooting ....................................................................................................................... 15

4.1 Troubleshooting ................................................................................................................................. 15


4.2 Alarm Information.............................................................................................................................. 16

Chapter 5 Test .......................................................................................................................................... 21

5.1 Test Equipment .................................................................................................................................. 21


5.2 Connection and Inspiration ................................................................................................................ 21
5.3 Function Test ...................................................................................................................................... 21
5.4 ECG Test .......................................................................................................................................... 21
5.5 Respiration Test ................................................................................................................................. 22
5.6 Temperature Test................................................................................................................................ 22
5.7 NIBP Test ........................................................................................................................................... 23
5.8 SpO2 Test ........................................................................................................................................... 23
5.9 Recorder Test ..................................................................................................................................... 24
5.10 Net Test ............................................................................................................................................ 24

Chapter 6 Maintenance and Cleaning ...................................................................................................... 25

6.1 System Checks ................................................................................................................................... 25


6.2 General Cleaning ................................................................................................................................ 25
6.3 Cleaning Agents ................................................................................................................................. 26
6.4 Sterilization ................................................................................................................................ 26

Patient Monitor Service Manual --I--


Chapter 1 Introduction

Chapter 1 Introduction
This monitor is suitable for the adult, the pediatric and the neonate, may monitor

the life parameters, such as the electrocardiograph (ECG), the noninvasive blood

pressure (NIBP), the oxygen saturation (SpO₂), the respiration rate (Resp), the body

temperature (Temp) and so on,, can in the same screen demonstrate maximum 8

waveforms and all information of the parameters monitored.

The purpose and function of the patient monitor is to monitor: ECG; heartrate;

noninvasive blood pressure (systolic, diastolic, and mean arterialpressures);

functional arterial oxygen saturation; respiration rate and temperature for adult and

pediatric patients in all hospital areas and hospital-type facilities. It can be used

during hospital transport and in mobile, land-based environments, such as

ambulances.

Below shows the functions of this monitor:


1) The electrocardiograph (ECG), including: the heart rate, 6 channels ECG
waveforms;

2) The oxygen saturation (SpO₂), including: the oxygen saturation , pulse rate,

pulse wave;
3) The noninvasive blood pressure (NIBP), including: Systolic pressure,
diastolic pressure, mean pressure;
4) The body temperature (Temp): 2 channels body temperature data;
5) The respiration (Resp): Breathing rate, breath waveform.

Patient Monitor Service Manual --1--


Chapter 2 Interface

Chapter 2 Interface
2.1 System Structure Diagram

2.2 Socket Interface

sensor socket

The following shows sensor socket:


T1: temperature channel 1 sensor socket;
T2: temperature channel 2 sensor socket;
SpO2: Oxygen saturation sensor socket;
NIBP: non-invasive blood pressure cuff socket;
ECG: ECG cable socket;

--2-- Patient Monitor Service Manual


Chapter 2 Interface

2.3 FY0805 Board Interface

socket Function
J1 Power

J5 Net

J6 TFT inverter

J8 TFT LCD
J11 Recorder

J17 Keyboard

J20 Speaker

PUMP PUMP & Valve


VALVE

ECG ECG
SPO2 SPO2

TEMP Temperature

Patient Monitor Service Manual --3--


Chapter 2 Interface

2.4 Keyboard Interface

socket Function

J1 To main board

J2 Encoder

J4 Alarm led

2.5 Power Board Interface

--4-- Patient Monitor Service Manual


Chapter 3 Disassembly Guide

Chapter 3 Disassembly Guide

3.1 System Overview

Patient Monitor Service Manual --5--


Chapter 3 Disassembly Guide

3.2 Front Case

3.3 Rear Case

--6-- Patient Monitor Service Manual


Chapter 3 Disassembly Guide

3.4 Disassembly Procedure

„ Disassembly Closed Case

1) Use a screwdriver to remove the two screws fastening the rear case to the
front case.
2) Open the front case.
3) Disconnect the keyboard cable, power switch cable, power led cable, TFT
cable and inverter cable from FY0501 board and keyboard, remove front
case.

„ Disassembly Front Case

1) Disconnect the keyboard cable, power switch cable and power led cable from
keyboard. Use a screwdriver remove keyboard.
2) Remove the TFT plate.
3) Remove the inverter board.
4) Remove the alarm led board.

„ Disassembly Rear Case

1) Use a screwdriver to remove the battery.


2) Disconnect the keyboard cable, inverter cable, speaker cable, net cable,
power cable, TFT cable and FY0501-FY0801 cable from FY0501 board, use
a screwdriver to remove FY0501 board.
3) Remove the cover plate.
4) Remove pump and valves tube.
5) Remove FY0801 board;
6) Remove power board;
7) Remove rear case plate;
8) Remove socket plate;
9) Remove fan, speaker and net board;

Patient Monitor Service Manual --7--


Chapter 3 Disassembly Guide

3.5 Cable Specification

„ AC Power Cable

„ AC Ground Cable

„ DC Output Cable

„ Fan Cable

--8-- Patient Monitor Service Manual


Chapter 3 Disassembly Guide

„ Power Switch

„ Battery Cable

„ LED Cable(LED1/LED2)

„ TFT Inverter Cable

Patient Monitor Service Manual --9--


Chapter 3 Disassembly Guide

„ TFP Cable

„ Keyboard Cable

„ Net Cable

--10-- Patient Monitor Service Manual


Chapter 3 Disassembly Guide

„ Alarm Led Cable

„ Encoder Cable

„ Pump Valve Cable

Patient Monitor Service Manual --11--


Chapter 3 Disassembly Guide

„ ECG Cable

„ SpO2 Cable

„ Temperature Cable

--12-- Patient Monitor Service Manual


Chapter 3 Disassembly Guide

3.6 BOM List

Material Code Material Name Specs. Qty.


ZJ00139 Front Case 1
ZJ00071 Rear Case 1
ZJ00032 TFT LCD 800*600 12.1’ LCD 1
ZJ00027 Encoder 79D12-05-M-03 1
ZJ00167 Recorder UC50-IC 1
P060903 FY0805 Board FY0801VA 1
ZJ00112 Inverter FLY-IV080102 1
ZJ00140 Keyboard KEY-ADECON 1
ZJ00198 Net board NET ADECON 1
ZJ00248 Alarm LED board ADECON 1
ZJ00107 Pump RPM27C-12E 1
ZJ00106 Valve KSV05B6-12V 2
ZJ00036 Gas tube Ф2.5-Ф6 1
ZJ00111 6-way gas outlet 6-CHA 1
ZJ00030 Battery 4.5AH Battety/12V 1
ZJ00116 Fan 5010-12V 1
ZJ00144 Speaker Q6.5 1
ZJ00058 Power Board FA71 1
ZJ00003 Power In Socket AS-01 1
ZJ00174 Fuse 1.6 A 2
ZJ00152 Fuse socket MF528 2
ZJ00150 Ground Pole 1
ZJ00119 TFT plate TF-01 1
ZJ00159 Rear Case Plate1 TF-02 1
ZJ00158 Rear Case Plate2 TF-03 1
ZJ00211 Power In Plate TF-04 1
ZJ00077 Battery Plate TF-05 1
ZJ00216 Battery Cover Plate TF-06 1
ZJ00118 Temperature Plate TF-07 1
ZJ00078 Sensor Plate TF-08 1
ZJ00157 Recorder Plate TY-01 1
ZJ00100 Inverter Cable 40CM(4P-5P-1.25MM) 1

Patient Monitor Service Manual --13--


Chapter 3 Disassembly Guide

ZJ00128 Keyboard Cable 20PIN-20PIN-2.0MM 1


ZJ00224 VGA Cable 20CM(6P-6P-2.0MM) 1
ZJ00059 TFT Cable 30PIN-30PIN 1
ZJ00098 ECG Cable 34CM(6P-2.5MM) 1
ZJ00099 SpO2 Cable 16CM(6P-2.0MM) 1
ZJ00246 Temp Cable 4P-2.0 400MM 1
ZJ00101 Alarm LED Cable 48CM(3P-3P-2.0MM) 1
ZJ00163 Fan Cable 2P-2.54 1
ZJ00163 Speaker Cable 2P-2.54 1
ZJ00163 Pump Cable 2P--2.0 1
ZJ00123 Valve Cable 4P--2.0 1
ZJ00171 Encoder Cable 6P-2.54 1

ZJ00165 Recorder Cable 6P-2.54 1

ZJ00053 ECG socket 6PIN 1


ZJ00007 Temp Socket 6.35-3 2
ZJ00074 SpO2 Socket 7 PIN 1
ZJ00168 NIBP Socket 1
ZJ00245 VGA socket DB9PIN 1

--14-- Patient Monitor Service Manual


Chapter 4 Troubleshooting

Chapter 4 Troubleshooting

4.1 Troubleshooting

Problem Recommended Action

No Power up With external power supply connected, push power switch, check
the green POWER LED on the front panel, if it is not lit, replace
power cable and power board.

LCD screen is totally Ensure that the backlight cable is connected to the FY0501
black or white. board. Ensure that the LCD connector is properly connected to
the FY0501 board and LCD. If problem persists, replace
backlight board or FY0501 board.

LCD screen is Ensure that the LCD connector is properly connected to the
illuminated, but no data FY0501 board and LCD. If problem persists, replace FY0501
is visible. board.

“COMM. STOP ERR” Ensure that the FY0501-FY0801 cable is properly connected to
the FY0501 board and FY00801 board. If problem persists,
replace FY0801 board.

Key or encoder do not Replace keyboard cable or keyboard. If problem persists, replace
work FY0501 board.

No sound Replace speaker cable or speaker. If problem persists, replace


FY0501 board.

Recorder do not work Ensure that recorder’s power led is on. Ensure the recorder cable
is properly connected to FY0501 board. If problem persists,
replace recorder or FY0501 board.

ECG no signal Check ECG cable,If problem persists, replace FY0801 board.

NIBP can’t inflate Ensure there is pump inflation sound when NIBP start, if no
pressure up sound, replace pump cable or pump. If pump is ok, check if there
is leakage in valve, replace valve cable or valve when there is
leakage, If problem persists, replace recorder or FY0801 board.

SPO2 no signal Ensure SPO2 cable is ok, If problem persists after changing
SpO2 cable, replace FY0801 board.

Respiration no signal Check ECG cable,If problem persists, replace recorder or


FY0801 board.

Temperature no signal Check temperature cable and temperature cable type setting,If
problem persists, replace recorder or FY0801 board.

Patient Monitor Service Manual --15--


Chapter 4 Troubleshooting

IBP no signal Ensure IBP cable is ok,If problem persists, replace FY0801
board.

CO2 no wavefrom Ensure CO2 cable is ok,If problem persists, replace CO2
module.

“CO2 COMM STOP” Ensure that the FY0501-CO2 cable is properly connected to the
FY0501 board and CO2 module. If problem persists, replace
CO2 module.

4.2 Alarm Information

The alarm Trigger condition Recommended Action

information

** ECG LEAD OFF RL or more than 2 ECG leads check the ECG lead
falls off connection

** ECG LEAD RA RA lead fall off check the ECG lead


OFF connection

** ECG LEAD LA LA lead fall off check the ECG lead


OFF connection

** ECG LEAD LL LL lead fall off check the ECG lead


OFF connection

** ECG LEAD V OFF V lead fall off check the ECG lead
connection

** MODULE INIT Module self-checking mistake Restart the machine, if


ERR error still existed,
contact the factory
service

***MODULE COMM The module and the main engine Restart the machine, if
STOP communication have the problem error still existed,
contact the factory
service

** MODULE COMM The module and the main engine Restart the machine, if
ERR communication have the problem error still existed,
contact the factory

--16-- Patient Monitor Service Manual


Chapter 4 Troubleshooting

service

** PARA ALARM The parameter of the alarm limit contact the factory
LMT ERR is modified by the accident service

** RANGE EXEED The parameter observed value has contact the factory
exceed the measurement scope service
which the system can carry on

** SpO ₂ SENSOR SpO₂ sensor does not connected Check SpO ₂ sensor
OFF connection

** SpO ₂ FINGER The finger fall off from SpO ₂ Check SpO ₂ sensor
OFF sensor connect with the finger

SEARCHING SpO₂ sensor connect bad or the Check SpO ₂ sensor


PULSE... patient move the arm connection situation and
patient's current
condition

** Temp1 SENSOR The body temperature channel 1 Check temperature


OFF sensor do not connect sensor connection

** Temp2 SENSOR The body temperature channel 2 Check temperature


OFF sensor do not connect sensor connection

** WATCHDOG ERR Main engine watch-dog Restart the machine, if


self-checking defeat wrong still existed,
contact the factory
service

** SYSTEM TIME The system clock has not set Change the system time
LOST as the current time, if
error still existed, related
the factory to carry on
the service

** 12V HIGH The 12V voltage examination Restart the machine, if


exceeds the normal voltage scope error still existed,
contact the factory
service

Patient Monitor Service Manual --17--


Chapter 4 Troubleshooting

** 12V LOW The 12V voltage examination is Restart the machine, if


lower than the normal voltage error still existed,
scope contact the factory
service

** 3.3V HIGH The 3.3V voltage examination Restart the machine, if


exceeds the normal voltage scope error still existed,
contact the factory
service

** 3.3V LOW The 3.3V voltage examination is Restart the machine, if


lower than the normal voltage error still existed,
scope contact the factory
service

**BAT HIGH The battery voltage examination Restart the machine, if


exceeds the normal voltage scope error still existed,
contact the factory
service

**BAT LOW The battery capacity is Meets the alternating


insufficient current to carry on the
charge immediately to
the battery

* NIBP LOOSE CUFF Reconnects the blood


The cuff has not connected
pressure cuff

* NIBP AIR LEAK check the pipe


connection situation or
The cuff has not connected good replace cuff, if the
or the air course leaks air breakdown still existed,
please contact the
factory service

* NIBP DEFLATE check the tube


When blood pressure
ERR connection or replace
measurement deflates has the
cuff, if the error still
problem
existed, please contact

--18-- Patient Monitor Service Manual


Chapter 4 Troubleshooting

the factory service

* NIBP WEAK Examined the patient


SIGNAL type set whether
When blood pressure
correctly, check the tube
measurement the pulse signal too
connection or replace
weak, is unable to calculate the
cuff, if the error still
blood pressure
existed, please contact
the factory service

* NIBP OUT OF When blood pressure check he tube connection


RANGE measurement the blood pressure or replace cuff, if the
or the pulse signal exceeds the error still existed, please
normal range, is unable to carry contact the factory
on the measurement service

* NIBP MOVEMENT Patient arm move Check the patient


situation or replace cuff,
if the error still existed,
please contact the
factory service

** NIBP OVER The pressure value exceeds the check the pipe
PRESSURE measurement scope connection situation or
replace cuff, if the error
still existed, please
contact the factory
service

* NIBP SATURATE When blood pressure Check the patient


measurement the pulse signal situation or replace cuff,
exceeds the normal range, is if the error still existed,
unable to carry on the please contact the
measurement factory service

* NIBP PNEUMATIC The cuff has not connected good check the pipe
FAIL or the air course leaks air connection situation or
replace cuff, if the error
still existed, please

Patient Monitor Service Manual --19--


Chapter 4 Troubleshooting

contact the factory


service

** NIBP SYSTEM Blood pressure system self-check Restart the machine, if


ERR defeat the error still existed,
please contact the
factory service

** NIBP TIME OUT Blood pressure measurement Restart the machine, if


overtime the error still existed,
please contact the
factory service

** NIBP CUFF TYPE Patient type for adult when has Check the patient type or
WRONG used the neonate cuff replace cuff, if the error
still existed, please
contact the factory
service

** NIBP MEASURE This blood pressure measurement Check the patient


FAIL has not been able to calculate the situation or replace cuff,
blood pressure if the error still existed,
please contact the
factory service

** NIBP RESET ERR When blood pressure Restart the machine, if


measurement exceptionally reset the error still existed,
please contact the
factory service

**RECORDER OUT There is no paper in recorder or Put paper in recorder and


OF PAPER the recorder door is open close the recorder door

--20-- Patient Monitor Service Manual


Chapter 5 Test

Chapter 5 Test

5.1 Test Equipment

FLUKE MPS450 or MEDISIM 300B ECG simulator

FLUKE BP Pump 2L or CuffLink NIBP simulator

FLUKE Index2 or SmartSat SpO2 simulator

Pressure calibrator or mercury manometer

Resistor box

Ruler

Network cable

Central monitor station

5.2 Connection and Inspiration

Connect the simulator, power cable and sensor cable to the patient monitor; turn on the
power. Patient monitor shall display startup picture and then enters monitor screen.

5.3 Function Test

„ Display Test
After patient monitor enter monitor screen, the characters and waves should display clearly
without dithers and blurs.

„ Key Test
Press every key on the keypad, the patient monitor shall execute the corresponding
function as instructed in the operation manual. The encoder shall execute the corresponding as
well.

„ Sound Test
There should be key sound when rotate encoder; there should be alarm sound when
triggers alarm.

5.4 ECG Test

„ ECG Calibrate
Set ECG channel 1 and channel 2’s gain to: ×1 and open ECG calibrate switch, ECG
wave should be a 1mV, 1Hz square wave, check the wave amplitude should be 10mm±0.5mm.

Patient Monitor Service Manual --21--


Chapter 5 Test

„ ECG Gain
Set ECG channel 1’s gain to: ×1, ECG channel 1 lead to II and set ECG simulator to input
a 1mV 1Hz square wave, ECG1 wave should be a 1mV, 1Hz square wave, check the wave
amplitude should be 10mm±0.5mm.

Set ECG channel 2’s gain to: ×1, ECG channel 2 lead to II and set ECG simulator to input
a 1mV 1Hz square wave, ECG2 wave should be a 1mV, 1Hz square wave, check the wave
amplitude should be 10mm±0.5mm.

„ ECG Lead
Set ECG simulator to input normal ECG wave, Select all ECG lead and gain, ECG wave
should be correct according to simulator.

„ Lead Off
Disconnect ECG lead from ECG simulator, there should be correct ECG lead off alarm.

„ Heart Rate
Set ECG simulator heart rate to be 30, 80, 300, the patient monitor’s heart rate should be
30, 80 and 300 respectively and error is below 1%.

„ Pace
Set “PACE” switch on and set simulator to input PACE signal, there should be PACE mark
on ECG wave.

5.5 Respiration Test

Set the base impedance to 1K and resistance respectively to 0.5Ω and 3Ω, RESP Rate
respectively to 30 and 120, the system shall measure the RESP Rate to be 29~31 and 118~
122.

5.6 Temperature Test

Set temperature sensor type to “10K” and resistor box to 30832Ω、19872Ω、8054Ω、6532


Ω、5330Ω,the temperature should be 1℃、10℃、30℃、35℃、40℃ respectively,error below
±0.1℃。

--22-- Patient Monitor Service Manual


Chapter 5 Test

5.7 NIBP Test

1) Set NIBP simulator to adult mode and pressure to 255/195/215 mmHg, set patient
monitor to adult mode and start NIBP test, when measurement finish, systolic, mean,
diastolic pressure should be 255±8mmHg,215±8mmHg 、195±8mmHg.

2) Set NIBP simulator to neonate mode and pressure to 120/80/90 mmHg, set patient
monitor to pediatric mode and start NIBP test, when measurement finish, systolic,
mean, diastolic pressure should be 120±8mmHg,90±8mmHg 、80±8mmHg.

3) Set NIBP simulator to neonate mode and pressure to 120/80/90 mmHg, set patient
monitor to neonate mode and start NIBP test, when measurement finish, systolic,
mean, diastolic pressure should be 40±8mmHg,20±8mmHg 、10±8mmHg.

„ NIBP Leakage Test


When the cuff is connected may use “Leakage Test” function to start air course charge
process, thus to discover whether the air way’s airtight condition is good or not. If the test
passes, the system will not make any prompt; If do not passed, then in the noninvasive blood
pressure parameter area will have the corresponding wrong prompt.

„ NIBP calibrations
Using a pressure gauge (or mercury sphygmomanometer) to carry on the calibration,
choose “NIBP Calibration” in the “Service” menu to start calibration.

Connect the pressure gauge, the cuff through a 3-way tube to the blood pressure trachea
jack on the monitor, setting the monitor as “calibration” mode, then charge the cuff using a air
pump, first make the pressure to 250 mmHg, then slowly deflates, when the monitor display 200,
150 and 50 mmHg, the difference between the standard pressure gauge value and the monitor
pressure value should in 3 mmHg. If the value exceeds 3 mmHg, please contact our company’s
attendant.

5.8 SpO2 Test

Put finger to SpO2 sensor and connect SpO2 sensor to the patient monitor, SpO2 value
should be above 95%.

Connect SpO2 sensor to SpO2 simulator and set simulator to 70%、75%、80%、85%、


90%、95%、100%,SpO2 value on patient monitor should be 70%、75%、80%、85%、90%、
95%、100% respectively,error below 2%.

Patient Monitor Service Manual --23--


Chapter 5 Test

5.9 Recorder Test

Press “RECORD” key, the recorder should output ECG waveform accordant to display.
Take out recorder paper, there should be “RECORDER OUT OF PAPER” alarm on patient
monitor.

5.10 Net Test

Connect patient monitor and central monitor station with network cable and start up patient

monitor and central monitor station, the net icon on patient monitor should be “ ”, there
should be waveform and parameter displayed on the central monitor station.

--24-- Patient Monitor Service Manual


Chapter 6 Maintenance and Clearing

Chapter 6 Maintenance and Cleaning

6.1 System Checks

„ Checks before using the monitor


1) Check if there is any mechanical damage;

2) Check if all the outer cables, inserted modules and accessories are in good
condition;

3) Check if all the monitoring functions of the monitor can work normally so as to make
sure that the monitor is in good condition.

If you find any damage on the monitor, stop using the monitor on patient, and contact the
biomedical engineer of the hospital or Customer Service Department immediately.

„ Routine check
The overall check of the monitor including the functional safety check, must be performed
by qualified personnel once every 6 to 12 month or each time after fix up. All checks that need to
open the monitor enclosure must be performed by qualified service personnel.

6.2 General Cleaning

The Patient Monitor must be kept dust-free.

It is recommended that you should clean the outside surface of the monitor enclosure and
the display screen regularly. Only use non-caustic detergents such as soap and water to clean
the monitor enclosure.

1) Avoid using ammonia-based or acetone-based cleaners such as acetone.

2) Most cleaning agents must be diluted before use. Dilute the cleaning agent as per
the manufacturer's direction.

3) Do not use the grinding material, such as steel wool etc.

4) Do not let the cleaning agent enter the monitor. Do not immerse any part of the
system into liquid.

5) Do not leave the cleaning agents at any part of the equipment.

Patient Monitor Service Manual --25--


Chapter 6 Maintenance and Cleaning

6.3 Cleaning Agents

The following solutions can be used as detergent:

1) Diluted Ammonia Water

2) Diluted Sodium Hyoichlo (Bleaching agent)

3) Diluted Formaldehyde 35% -- 37%

4) Hydrogen Peroxide 3%

5) Alcohol

6) Isopropanol

6.4 Sterilization

To avoid extended damage to the equipment, sterilization is only recommended when


stipulated as necessary in the Hospital Maintenance Schedule. Sterilization facilities must be
cleaned first.

Recommended sterilization materials: Ethylate, and Acetaldehyde.

--26-- Patient Monitor Service Manual


Shenzhen Biocare Electronics CO.,Ltd.

2nd.Floor.Baili Park,No.636 Baotian 1st Road Tiegang,Baoan,Shenzhen.china.

Tel:86-755-27960641 Fax:86-755-27960443

Website:http://www.biocare.com.cn