Академический Документы
Профессиональный Документы
Культура Документы
A. LABORATORIUM FARMASI
No. Nama Barang Spesifika Gamba
si r
1. Autoclave
Electromechanical lock system, Dual-sensing interlock mechanism, Pulse
exhaust system, Memory Function, Process status display | Outer Dimensions
WDH (mm) : approx. 547 X 532 X 1046 | Chamber Size (Volume) : min. 300f x
710H (min. 54.2 Liter) | Effective capacity : min. 50 Liter | Power source : 220V,
50/ 60 Hz | Power consumption: min. 2.0 kW | Net Weight (Approx.) : 57 Kg |
Chamber Material : Stainless Steel (SUS304) | Sterilization temperature range :
approx. 105?C to 135?C | Maximum allowable pressure (Gauge pressure) :
approx. 0.255 Mpa | Temperature display range : approx. 5?C to 137?C |
Warming temperature range : approx. 45?C to 80?C | Sterilization timer :
approx. 1 to 250 minutes | Pressure gauge : approx. 0 to 0.4 Mpa | Selective
mode (cycle) : Agar sterilization (with Warming) : Preparation -- Heating --
Sterilization -- Exhaust (P0, P1, or P2) -- Warming - Completion; Liquid sterilization :
5. Heating Mantle Preparation -- Heating -- Sterilization -- Exhaust (P0, P1, or P2) - Completion;
Sterilization of solid/ medical equipment : Preparation -- Heating -- Sterilization --
Exhaust (Forced) - Completion | Safety devices/ warning alarm : Double sensing
interlock mechanism, Over-pressure power cut-offm, Over-temperature power
cut-off, Heater malfunction checker, Temperature sensor wire breakage
detector, Securely closed lid check function, Excess cooling check function,
Exhaust bottle ready-to-use check system, Lack-of-water prevention device,
Power failure check function, Electric leakage breaker and over current
detector | Pressure safety valve, Product are manufactured by the company
with ISO 9001/ 13485 and ISO 14001
Flexible coiled heating elements absorb shock, minimizing the risk of flasks breaking| Heating
element is attached to rigid thermal insulating cartridge to ensure maximum heat transfer and
support| Heating elements and insulation form an easy-to-replace heating cartridge| Unique
airflow through ventilation slots beneath and around the rim and heating cartridge keep the
exterior “cool-to-the-touch”| Stainless-steel screen covering the heating element is grounded
directly to the cable for added protection| Mantles are double fused for added safety|
Nonskid feet and support clamps add stability| Flask capacity: 1000mL| Case Material:
Powder-coated aluminium| Max Element Temperature: 450°C| Certifications/Compliance CE,
CSA
6. Number of stirring positions: 1 | Stirring quantity max. per stirring position (H2O) : min 10 L
Hotplate Magnetic
Stirrer | Stirring quantity max. (H2O) : 10 L | Motor rating input : 15 W | Motor rating output: 1.5
W | Speed display scale | Speed range : 100 - 1500 rpm | Heat output : 1000 W | Heating
rate (1 l H2O in H15) : 5 K/min | Heating temperature range : approx. 50 - 500°C | Heat
control LED | Heat control accuracy : ±10 K | Speed control : scale 0 – 6 | Fixed safety circuit
: 550°C | Set-up plate material: Glass ceramic | Set-up plate dimensions : approx. 180 x 180
mm | Dimensions WHD : approx. 220 x 105 x 330 mm | Weight : approx. 5 Kg | Permissible
ambient temperature
: 5 - 40°C | Permissible relative moisture : 80% | Protection class according to DIN EN 60529
: IP 21 | Voltage : 230V| Frequency : 50/60 Hz | Power input : 1005 W
7. Control COCKPIT adaptive multifunctional digital PID-microprocessor
Incubator
controller with high-definition TFT-colour display | Temperature 1 Pt100 sensor
DIN class A in 4-wire-circuit | TimerDigital backwards counter with target time
setting, adjustable from 1 minute to 99 days |temperature range in °C min.
5°C above ambient up to +80°C | Door inner glass door |Internals 1 stainless
steel grids | Scope of delivery incl. works calibration certificate for +37°C
|Housing rear zinc-plated steel | Interior easy-to-clean interior,made of
stainless steel,reinforced by deep drawn ribbing with integrated and protected
large-area heating on four sides | Volume 53 Liter | texture stainless steel
casing WHD: approx. 585x784x514mm; power: approx. 1000W; max. loading
of chamber: approx. 80Kg
13 Gravity convection technology for gentle drying & heating with low air
Universal Oven
turbulences; Perfect for working with materials that are sensitive to airflow
such as powders and foils; Interior material: stainless steel 1.4301; Rounded
interior corners; Microprocessor control; Automatic overtemperature alarm;
Stackable with optional stacking kit; Easy calibration, routine check upon
startup for optimum performance; Timer function: choice of weekly / hourly
/ realtime; Fresh air damper: electronically controlled; Access port for
independent data monitoring; RS232 Interface; Programmable ramps and
dwells; Boost function for accelerated heat-up; Dry alarm contact for
connection of alarm device; Large, easy to view vacuum fluorescent digital
display; Temperature range: approx 50-330°C; Spatial temperature
deviation at 150°C: ± 3°C; Temperature deviation over time at 150°C: ±
0.3°C; Footprint: 0.36 m2; Chamber volume: min 99 liter; Chamber
dimensions: approx. 438 x 580 x 389 mm (WxHxD); Exterior dimensions:
approx. 640 x 820 x 565 mm (WxHxD); Number of shelves: 2 pcs supplied,
max. 16 pcs; Max. shelf load: 25 kg; Power: 230V, 50Hz, 3,100 W, 13.5A.
14. c Optical Design : Double Beam with sample and reference cuvette; positions;
UV-Visible
. Czerny-Turner Monochromator; Spectral Bandwidth : 1 nm; Light Source :
Spectrophotometer Xenon flash lamp; Detector : Dual Silicon Photodiodes; Scan Ordinate Modes
: Absorbance, % Transmittance, % Reflectance, Kubelka-Munk, log (1/R),
log (Abs), Abs*Factor, Intensity; Wavelength Range : 190 –1100 nm;
Wavelength Accuracy : ±0.2 nm (541.9, 546.1 nm mercury lines) ±0.5 nm
(full range 190–1100 nm); Wavelength Repeatability : ?0.01 nm (546.1 nm
mercury line, SD of 10 measurements); Scanning Speed : <1 to 6000
nm/min; variable; Data Intervals : 10, 5, 2, 1.0, 0.5, 0.2, 0.1 nm;
Photometric Range : > 3.5 Abs; Photometric Display Range : -0.3 to 4.0 A;
Photometric Accuracy :1A: ±0.002 A; 2A: ±0.004 A; Measured at 440 nm
using neutral density filters traceable to NIST; Photometric Repeatability :
±0.0002 A; Photometric Noise 0A: ?0.00008 A; 260 nm, 1.0 nm SBW, RMS;
Photometric Drift (Stability) : <0.0005 A/hr; 500 nm, 1.0 nm SBW, 1 hour
warm-up; Stray light : KCl, 198 nm: ?0.40% T, NaI, 220 nm: ?0.027% T,
NaNO2, 340 nm: <0.025% T; Baseline flatness: ±0.0006 A; 200–800 nm,
1.0 nm SBW, smoothing, Keypad : Sealed Membrane, Electrical Supply :
100 – 240 V, 50 – 60 Hz, Selected Automatically; .....
15.
Waterbath Control microprocessor PID-temperature controller with integrated autodiagnostic system
with fault indicator| solid state switching unit| one Pt100 sensor class A in 4-wire-circuit|
integrated digital timer from 1 min. to 99,59 hours for: ON continuous operation, WAIT
(delayed on for continuous and limited timed operation), HOLD digital display (LED) of set and
actual temperature (0,1 °C resolution) and of (remaining) programme time, LEDs for indication
of programme status, Overtemperature protection (double) in case of overtemperature due to
failure, the heating is switched off at approx. 10°C above the set temperature (fixed value)
mechanical temperature limiter TB protection class 1 switching the heating off at approx. 30 °C
above max. temperature of the bath. Textured Stainless Steel Casing: LWH : approx. 578 x 436
x 296 mm, min. material 1.4301 (ASTM 304), corrosion resistant| Interior - Heating Concept: