Quick User Guide sensor is connected or Power Supply Specification Construction, Installation, and Wiring

4 Channel Scanner-8204 not. Specification


MEASUREMENT 1 mA RATED VOLTAGE 85-260 VAC-50/60Hz
CURRENT(RTD) 100-300 VDC or 18-36 MATERIAL ABS resin and
INPUT IMPEDANCE >1 MΩ for TC/RTD/Linear VDC Polycarbonate
input POWER Max. <10 VA CONSTRUCTION Only the front panel is
NMRR > 40 dB (50/60 Hz) CONSUMPTION dust-proof
CMRR > 120 dB (50/60 Hz) DATA BACKUP Non-volatile memory CASE COLOR Black
ALLOWABLE Maximum 15 Ω/wire WEIGHT < 0.4 kg
WIRING (Conductor resistance Isolations (Withstanding Voltage) DIMENSIONS 48 (W) x 96 (H) x 130
RESISTANCE FOR between three wires (depth from panel face)
RTD should be equal).  Between primary terminals* and secondary mm
terminals**: 1500VAC for 1 minute INSTALLATION Panel-mounting type.
Retransmission Output (Optional)  Between secondary terminals: 500V AC for 1 With Top and Bottom
8204 Universal Scanner minute mounting hardware (1
NUMBER OF OUTPUTS 1 * Primary terminals indicate power terminals and each)
Input Input
Range Range OUTPUT SIGNALS 0-20mA, 4-20mA, 0-5V, relay output terminals PANEL CUTOUT 46 x 92 mm
Type Type
1-5V or 0-10V DC ** Secondary terminals indicate analog input signals, FRONT BEZEL 48 x 96 mm
- 200 t o 0 to 75 Digital Contact output terminals, communication
E LOAD RESISTANCE ≤500 ohms for current
1000 C mV terminals and Ethernet N/W terminal
o/p MOUNTING DETAILS
- 200 t o 0 to 100
J ≥3K ohms for voltage
1200 C mV Insulation Resistance: 20MΩ or more at 500 V DC
o/p
- 200 t o 0.4 to 2
K
1370 C V OUTPUT ACCURACY ±0.25% of span Signal Isolation Specifications
- 200 t o
T 0 to 2 V
400 C Relay Contact Outputs Signals Signal Isolation
450 t o 0 to 20 - 1999
B PV Input Terminals Not isolated input
1800 C mA to NUMBER OF OUTPUTS 4 terminals and from the
4 to 20 9999 OUTPUT SIGNAL Two terminals (NC/NO
R 0 t o 17 50 C internal circuit. But
mA and C) (NC/NO is isolated from other
S 0 t o 17 50 C 0 to 5 V selectable by jumper input/output terminals.
- 200 t o setting) Retransmission Not isolated from
N 1 to 5 V Output terminals current or voltage
1300 °C RELAY CONTACT 250 VAC / 30 VDC @ 2A
0 to 10 V RATING outputs but Isolated
-199.9 to from other input/output
RTD(PT100) -10 to 20
850.0C terminals and internal
mV Communication Specification circuit.
Table 1.1
RS-485 Isolated from other
COMMUNICATION Half
SPECIFICATIONS Communication input/output terminals
TYPE duplex/Asynchronous
and internal circuit
ACCURACY +0.1% of instrument COMMUNICATION MODBUS RTU. All
Relay contacts Isolated between
TC: range +1 digit for temp. PROTOCOL parameters are
Control output contact output
≥0ºC OR + 0.25% of Configurable through
Terminals terminals and from
instrument range + 1 MODBUS Protocol.
other Input/output
digit for temp. <0ºC OR MAXIMUM NO. OF 32 terminals and internal
+0.25% of instrument UNITS circuit.
range + 1 digit(B,R,S COMMUN. ERROR CRC Check
Power Terminals Isolated from other
RTD/LINEAR: TYPE TC) DETECTION
input/output terminals
+ 0.1% of instrument and internal circuit
range + 1 digit Display Specification
RESOLUTION ADC: 17 bits
PV DISPLAY 4-digits, 7-segment, Environmental Specification
TC(E,J,K,T,N)/RTD: 0.1C
TC(B,R,S): 1C Red LEDs , 0.56”
character height AMBIENT
LINEAR: 1 Count 0 to 55°C
CHANNEL NO. 1-digits, 7-segment, TEMPERATURE
APPLICABLE DIN (ITS-90) for
STANDARD Thermocouple and RTD DISPLAY Green LEDs, 0.56’’ 30% to 95% RH (Non-
HUMIDITY
INPUT TYPE Refer table 1.1 character height Condensing)
SAMPLING PERIOD TC & Linear Input: 100 STATUS INDICATING 4-Red LEDs for Relay  For Data < 100ppm
LEDs status, 1-Red LED for TEMPERATURE
PER INPUT ms  For Retransmission <
Manual mode status, 2- COEFFICIENT
RTD: 200 ms 150ppm
BURNOUT For TC, RTD, linear input Red LEDs for INSTRUMENT WARM- >30 mins after power
DETECTION signal It detects whether Communication UP TIME on
Doc.Ref. No. m82/QG/101 Issue No.:00 Page 1 of 2
FRONT PANEL DESCRIPTION BACK PLATE CONNECTION DETAIL CONTROL OUTPUT (ON/OFF CONTROL)

ON/OFF Controller is the simplest form of


Name of
Function temperature control device. The output from the
Part
device is either on or off, with no middle state. An
on-off controller will switch the output only when the
temperature crosses the set point. For heating
It is used to enter in the sub menu
control, the output is on when the temperature is
(various levels) and save the
below the set point, and off above set point. Since
parameters to non-volatile memory
the temperature crosses the set point to change the
output stage, the process temperature will be cycling
continually, going from below set point to above, and
It is used to come out from any sub back below.
menu (various levels) to the run In cases where this cycling occurs rapidly, and to
mode. It is used for come out of the prevent contactors and valves from getting damaged,
manual mode to auto mode too an on-off differential, or “hysteresis,” is added to the
controller operations. This hysteresis assures, if
temperature exceed set point by a certain amount
before then only output will turn off or on again. On-
It is used to increment the parameter Off hysteresis prevents the output from “chattering”
for selection. or making fast, continual switches if the cycling
above and below the set point occurs very rapidly.

Relay type High (H-ON):


It is used to Shift the digit to set the
For High type of set value, once process value
parameter or decrement the
reaches up to set point + Hysteresis value,
parameter
relay will be ON after few seconds (as per relay
delay) and it will be ON until process value goes
down to Set point.
Displays Process Value. Display
Parameter Name When You Set Relay type Low (L-ON):
PV Parameter. Displays Error Message For Low type of set value, once process value
When An Error Occurs. reaches down to set point - Hysteresis value relay
will be ON after nearly few seconds (as per relay
RELAY OUTPUTS delay) and it will be ON until process value goes up
toward Set point.
Following function can be set for Relay outputs
Displays Channel Number in run NOTE:
mode. Also it will display relay number Relay Function: Relay function can be selected as 8204 has both Control Logic (ON-OFF) & Alarm Logic.
(01 – 04) in set mode ALARM or TRIP. If Control Logic (ON-OFF) is required, rloP in lvl2
CH No.
(i.e.R.1,R.2,R.3,R.4). It will also must be selected as Co.Whenever Control
display Group no(GP 1,GP 2/GP 1,GP  If relay is selected as ALARM, when abnormal Output(ON-OFF) logic is selected , all relays are
2,GP 3,GP 4) in set mode condition occur Relay will ON, once normal mapped as shown in chapter no.6. As well as, relay
condition after abnormal condition occur Relay will latch is off and relay group is assigned as relay per
OFF. group 1. In this logic, user cannot change relay
 If relay is selected as TRIP, when abnormal mapping, relay latch and relay group and user cannot
condition occur Relay will ON, once normal acknowledge relays.
When Respective Relay LED Lits (In
condition after abnormal condition occur Relay will
RL1, RL2, Red) OR When Channel is
ON. Relay will be off through Acknowledge.
RL3, RL4 OPEN(Channel no. is corresponding to
Relay no.)
Relay Delay: A time delay can be provided for the
actual output.

Relay Open Sensor: Open sensor up scale or down


If LED is on, it indicates Manual mode
A/M scale can be selected for each relay output.
and if LED is off Auto Mode. For operation manual please visit www.masibus.com
Relay Mapping: Refer Menu layout LEVEL - 2 Specifications are subject to change without notice due to
continuous improvements.
Masibus Automation And Instrumentation Pvt. Ltd.
When Communication on, two LEDs Relay Types: Various relay operations are shown in B-30, GIDC Electronics Estate, Sector-25, Gandhinagar-
Rx/Tx the reference figure. (High, Low, Very High- High, 382044, Gujarat, India.
(In Red) blink.
Low-Very Low, High- Low) Tel:+91 79 23287275-79 Fax: +91 79 23287281
For relay types selection Refer Menu layout LEVEL-2 Web:www.masibus.com Email:support@masibus.com

Doc.Ref. No. m82/QG/101 Issue No.:00 Page 2 of 2