Quick User Guide sensor is connected or Power Supply Specification Construction, Installation, and Wiring
4 Channel Scanner-8204 not. Specification
MEASUREMENT 1 mA RATED VOLTAGE 85-260 VAC-50/60Hz CURRENT(RTD) 100-300 VDC or 18-36 MATERIAL ABS resin and INPUT IMPEDANCE >1 MΩ for TC/RTD/Linear VDC Polycarbonate input POWER Max. <10 VA CONSTRUCTION Only the front panel is NMRR > 40 dB (50/60 Hz) CONSUMPTION dust-proof CMRR > 120 dB (50/60 Hz) DATA BACKUP Non-volatile memory CASE COLOR Black ALLOWABLE Maximum 15 Ω/wire WEIGHT < 0.4 kg WIRING (Conductor resistance Isolations (Withstanding Voltage) DIMENSIONS 48 (W) x 96 (H) x 130 RESISTANCE FOR between three wires (depth from panel face) RTD should be equal). Between primary terminals* and secondary mm terminals**: 1500VAC for 1 minute INSTALLATION Panel-mounting type. Retransmission Output (Optional) Between secondary terminals: 500V AC for 1 With Top and Bottom 8204 Universal Scanner minute mounting hardware (1 NUMBER OF OUTPUTS 1 * Primary terminals indicate power terminals and each) Input Input Range Range OUTPUT SIGNALS 0-20mA, 4-20mA, 0-5V, relay output terminals PANEL CUTOUT 46 x 92 mm Type Type 1-5V or 0-10V DC ** Secondary terminals indicate analog input signals, FRONT BEZEL 48 x 96 mm - 200 t o 0 to 75 Digital Contact output terminals, communication E LOAD RESISTANCE ≤500 ohms for current 1000 C mV terminals and Ethernet N/W terminal o/p MOUNTING DETAILS - 200 t o 0 to 100 J ≥3K ohms for voltage 1200 C mV Insulation Resistance: 20MΩ or more at 500 V DC o/p - 200 t o 0.4 to 2 K 1370 C V OUTPUT ACCURACY ±0.25% of span Signal Isolation Specifications - 200 t o T 0 to 2 V 400 C Relay Contact Outputs Signals Signal Isolation 450 t o 0 to 20 - 1999 B PV Input Terminals Not isolated input 1800 C mA to NUMBER OF OUTPUTS 4 terminals and from the 4 to 20 9999 OUTPUT SIGNAL Two terminals (NC/NO R 0 t o 17 50 C internal circuit. But mA and C) (NC/NO is isolated from other S 0 t o 17 50 C 0 to 5 V selectable by jumper input/output terminals. - 200 t o setting) Retransmission Not isolated from N 1 to 5 V Output terminals current or voltage 1300 °C RELAY CONTACT 250 VAC / 30 VDC @ 2A 0 to 10 V RATING outputs but Isolated -199.9 to from other input/output RTD(PT100) -10 to 20 850.0C terminals and internal mV Communication Specification circuit. Table 1.1 RS-485 Isolated from other COMMUNICATION Half SPECIFICATIONS Communication input/output terminals TYPE duplex/Asynchronous and internal circuit ACCURACY +0.1% of instrument COMMUNICATION MODBUS RTU. All Relay contacts Isolated between TC: range +1 digit for temp. PROTOCOL parameters are Control output contact output ≥0ºC OR + 0.25% of Configurable through Terminals terminals and from instrument range + 1 MODBUS Protocol. other Input/output digit for temp. <0ºC OR MAXIMUM NO. OF 32 terminals and internal +0.25% of instrument UNITS circuit. range + 1 digit(B,R,S COMMUN. ERROR CRC Check Power Terminals Isolated from other RTD/LINEAR: TYPE TC) DETECTION input/output terminals + 0.1% of instrument and internal circuit range + 1 digit Display Specification RESOLUTION ADC: 17 bits PV DISPLAY 4-digits, 7-segment, Environmental Specification TC(E,J,K,T,N)/RTD: 0.1C TC(B,R,S): 1C Red LEDs , 0.56” character height AMBIENT LINEAR: 1 Count 0 to 55°C CHANNEL NO. 1-digits, 7-segment, TEMPERATURE APPLICABLE DIN (ITS-90) for STANDARD Thermocouple and RTD DISPLAY Green LEDs, 0.56’’ 30% to 95% RH (Non- HUMIDITY INPUT TYPE Refer table 1.1 character height Condensing) SAMPLING PERIOD TC & Linear Input: 100 STATUS INDICATING 4-Red LEDs for Relay For Data < 100ppm LEDs status, 1-Red LED for TEMPERATURE PER INPUT ms For Retransmission < Manual mode status, 2- COEFFICIENT RTD: 200 ms 150ppm BURNOUT For TC, RTD, linear input Red LEDs for INSTRUMENT WARM- >30 mins after power DETECTION signal It detects whether Communication UP TIME on Doc.Ref. No. m82/QG/101 Issue No.:00 Page 1 of 2 FRONT PANEL DESCRIPTION BACK PLATE CONNECTION DETAIL CONTROL OUTPUT (ON/OFF CONTROL)
ON/OFF Controller is the simplest form of
Name of Function temperature control device. The output from the Part device is either on or off, with no middle state. An on-off controller will switch the output only when the temperature crosses the set point. For heating It is used to enter in the sub menu control, the output is on when the temperature is (various levels) and save the below the set point, and off above set point. Since parameters to non-volatile memory the temperature crosses the set point to change the output stage, the process temperature will be cycling continually, going from below set point to above, and It is used to come out from any sub back below. menu (various levels) to the run In cases where this cycling occurs rapidly, and to mode. It is used for come out of the prevent contactors and valves from getting damaged, manual mode to auto mode too an on-off differential, or “hysteresis,” is added to the controller operations. This hysteresis assures, if temperature exceed set point by a certain amount before then only output will turn off or on again. On- It is used to increment the parameter Off hysteresis prevents the output from “chattering” for selection. or making fast, continual switches if the cycling above and below the set point occurs very rapidly.
Relay type High (H-ON):
It is used to Shift the digit to set the For High type of set value, once process value parameter or decrement the reaches up to set point + Hysteresis value, parameter relay will be ON after few seconds (as per relay delay) and it will be ON until process value goes down to Set point. Displays Process Value. Display Parameter Name When You Set Relay type Low (L-ON): PV Parameter. Displays Error Message For Low type of set value, once process value When An Error Occurs. reaches down to set point - Hysteresis value relay will be ON after nearly few seconds (as per relay RELAY OUTPUTS delay) and it will be ON until process value goes up toward Set point. Following function can be set for Relay outputs Displays Channel Number in run NOTE: mode. Also it will display relay number Relay Function: Relay function can be selected as 8204 has both Control Logic (ON-OFF) & Alarm Logic. (01 – 04) in set mode ALARM or TRIP. If Control Logic (ON-OFF) is required, rloP in lvl2 CH No. (i.e.R.1,R.2,R.3,R.4). It will also must be selected as Co.Whenever Control display Group no(GP 1,GP 2/GP 1,GP If relay is selected as ALARM, when abnormal Output(ON-OFF) logic is selected , all relays are 2,GP 3,GP 4) in set mode condition occur Relay will ON, once normal mapped as shown in chapter no.6. As well as, relay condition after abnormal condition occur Relay will latch is off and relay group is assigned as relay per OFF. group 1. In this logic, user cannot change relay If relay is selected as TRIP, when abnormal mapping, relay latch and relay group and user cannot condition occur Relay will ON, once normal acknowledge relays. When Respective Relay LED Lits (In condition after abnormal condition occur Relay will RL1, RL2, Red) OR When Channel is ON. Relay will be off through Acknowledge. RL3, RL4 OPEN(Channel no. is corresponding to Relay no.) Relay Delay: A time delay can be provided for the actual output.
Relay Open Sensor: Open sensor up scale or down
If LED is on, it indicates Manual mode A/M scale can be selected for each relay output. and if LED is off Auto Mode. For operation manual please visit www.masibus.com Relay Mapping: Refer Menu layout LEVEL - 2 Specifications are subject to change without notice due to continuous improvements. Masibus Automation And Instrumentation Pvt. Ltd. When Communication on, two LEDs Relay Types: Various relay operations are shown in B-30, GIDC Electronics Estate, Sector-25, Gandhinagar- Rx/Tx the reference figure. (High, Low, Very High- High, 382044, Gujarat, India. (In Red) blink. Low-Very Low, High- Low) Tel:+91 79 23287275-79 Fax: +91 79 23287281 For relay types selection Refer Menu layout LEVEL-2 Web:www.masibus.com Email:support@masibus.com