Ultrasound Ultraprobe 10,000 Instructions

Ultraprobe 201 Indentification and Operation


Rev. 1.0 3/2012 SAFETY: Wrist Strap to be worn at ALL TIMES TQC Work Verify
5 min UE Systems Training

Identification of Parts of Ultraprobe 201 "Grease The "Grease Caddy" can be attached to a Grease
1 Caddy." 2 Gun or Worn in a Holster w/Belt Clip.

10 LED that equal 3 dB Each. ON/OFF Bottons w/ To Calculate Decibel, count Number of LEDs '5'
3 5min auto off. 8 Position Sensitivity Selector with 4 multiply by 3 (=15). Add to Sensitivity Setting' 50'
'0' being highest sensitivity. (3 X 5 = 15 + 50 = 65 dB).

Page 1 of 3 *Lubricate Slowly and Cautiously*


Ultrasound Ultraprobe 10,000 Instructions
Ultraprobe 201 Indentification and Operation
Rev. 1.0 3/2012 SAFETY: Wrist Strap to be worn at ALL TIMES TQC Work Verify
5 min UE Systems Training

Possible Location of Magnet on Bearing Housing, Possible Location of Magnet on Bearing Housing,
5 side of Housing. Never on Fan Shrouds or Covers. 6 top of Housing. Never on Fan Shrouds or Covers.

Possible Location of Magnet; Tip of Grease Gun, While Lubing, Make Sure that the Display of the
7 when Bearing Housing Cannot be Reached. 8 'Grease Caddy can be Viewed, to note Decibel
Change of the bearing.

Page 2 of 3 *Lubricate Slowly and Cautiously*


Ultrasound Ultraprobe 10,000 Instructions
Ultraprobe 201 Indentification and Operation
Rev. 1.0 3/2012 SAFETY: Wrist Strap to be worn at ALL TIMES TQC Work Verify
5 min UE Systems Training

While operating the 'Grease Caddy,' Headphones ADD lube until DECIBEL DROPS to Baseline or
9 should be worn to be able to hear the Change of 10 unitl Decibel Drops and Levels & will not decrease
sound of the bearing. anymore.

The Number One Cause of Bearing Failure is Decibel of 201 Ultraprobe may not match Decibel of
11 OVERLUBRICATION. Be Cautious and Lube 12 Other Ultraprobes. You are only looking for
Slowly. Change in Decibel.

Page 3 of 3 *Lubricate Slowly and Cautiously*